Hygiena SystemSURE Plus SS3 ATP Luminometer
The Hygiena SystemSURE Plus SS3 is a portable ATP luminometer used to verify cleaning effectiveness on surfaces and in water samples. It provides results in approximately 15 seconds when used with compatible Hygiena ATP test devices, helping sanitation and QA/QC teams identify areas requiring additional cleaning.
Designed for routine hygiene monitoring, SystemSURE Plus features programmable pass, caution and fail limits, storage for 2,000 results, a backlit display and support for Hygiena SureTrend desktop software.
It is a practical choice for Canadian food processors, breweries, beverage manufacturers, dairy plants, sanitation contractors and other facilities that need consistent ATP cleaning verification without the added features of a touchscreen or cloud-based instrument.
Ideal Applications
- Food processing sanitation and pre-operational cleaning checks
- Brewery, winery and beverage production equipment
- Dairy processing and cleaning-in-place (CIP) rinse-water monitoring
- Food-contact surfaces, conveyors, fillers, mixers and production tables
- Commercial kitchens and foodservice sanitation
- Industrial production and QA/QC cleaning verification
- Healthcare and institutional environmental cleaning programs
- Facilities maintaining HACCP, GMP and sanitation verification procedures
Why Choose Hygiena SystemSURE Plus?
- Results in 15 seconds: Quickly check cleaned surfaces or appropriate water samples before the next production step.
- Objective ATP measurements: Displays results in Relative Light Units (RLU), reducing reliance on visual inspection alone.
- Pass, caution and fail limits: Create limits suited to your facility's sampling locations and cleaning procedures.
- 2,000-result memory: Store testing results for review and download.
- Programmable testing: Supports up to 100 test plans, 200 user IDs and approximately 5,000 programmed test locations.
- Portable design: Compact handheld instrument powered by two AA batteries.
- Simple operation: Backlit LCD, keypad controls and quick-test mode.
- Photodiode sensor: Solid-state light detection technology designed for dependable routine measurements.
- Calibration self-check: Automatically checks instrument calibration during startup.
- Data management: Supports Hygiena SureTrend desktop software for reviewing results and identifying sanitation trends.
How Does ATP Hygiene Testing Work?
ATP, or adenosine triphosphate, is found in living cells and biological material. After a surface or water sample is collected, the test device produces a light-generating reaction related to the ATP present.
The SystemSURE Plus luminometer measures this light and reports the result in RLU.
- Collect a sample: Use a compatible Hygiena UltraSnap surface swab or AquaSnap water testing device.
- Activate the test: Follow the instructions supplied with the selected Hygiena test device.
- Measure: Insert the activated device into the luminometer and begin the measurement.
- Review the result: The instrument displays an RLU reading in approximately 15 seconds.
- Take action: Compare the result with your facility's established limits. Reclean and retest locations when required.
SystemSURE Plus can help teams move from subjective visual inspection to a more consistent and documented cleaning verification process.
Compatible Hygiena ATP Swabs and Water Tests
SystemSURE Plus requires compatible Hygiena test devices. The instrument and consumable tests are separate components of the testing system.
| Product | What It Tests | Best Use |
|---|---|---|
| UltraSnap US2020 | Surface ATP | Equipment, food-contact surfaces, tools and production areas |
| AquaSnap Total AQ-100X | Total ATP in water | CIP rinse water, process water and liquid cleaning verification |
| AquaSnap Free AQ-100FX | Free dissolved ATP in water | Water testing where the free ATP fraction is required |
Each of these test products is available in 100-test packages. The correct format depends on whether your facility needs surface testing, water testing or both.
For water monitoring, AquaSnap Total measures free and microbial ATP together. AquaSnap Free measures ATP dissolved in the sample. The two formats can be used together when an estimate of the microbial ATP portion is needed.
Explore our ATP Testing and Sanitation Verification collection for compatible consumables and other monitoring equipment.
SystemSURE Plus vs. EnSURE Touch
Hygiena offers both SystemSURE Plus and EnSURE Touch for ATP cleaning verification. Both are capable of rapid ATP testing, but they are designed for different levels of data management and operational requirements.
| Feature | SystemSURE Plus | EnSURE Touch |
|---|---|---|
| ATP Measurement | 15 seconds | 10 seconds |
| Display | Backlit LCD and keypad | 5-inch touchscreen |
| Power | Two AA batteries | Rechargeable battery |
| Data Management | SureTrend desktop software | SureTrend Cloud integration |
| Connectivity | Serial connection with appropriate computer adapter | Wi-Fi and USB |
| Best Fit | Routine ATP verification using a conventional handheld instrument | More extensive monitoring with touchscreen operation and cloud reporting |
Which Hygiena Luminometer Should You Choose?
Choose SystemSURE Plus if your facility primarily needs routine surface or water ATP testing, straightforward controls and conventional result storage.
Consider EnSURE Touch if your facility needs a touchscreen interface, Wi-Fi connectivity, centralized cloud reporting or a broader Hygiena testing program.
For new facilities, we recommend considering expected test volume, reporting requirements, computer compatibility and ongoing swab costs before selecting an instrument.
View the Hygiena EnSURE Touch ATP Luminometer for comparison.
Technical Specifications
| Manufacturer | Hygiena |
| Model | SystemSURE Plus |
| Manufacturer Part Number | SS3 |
| Measurement Technology | ATP bioluminescence, photodiode sensor |
| Measurement Range | 0 to 9,999 RLU |
| Resolution | 1 RLU |
| Measurement Time | 15 seconds |
| Detection Sensitivity | Down to 1 femtomole ATP, per manufacturer brochure |
| Result Memory | 2,000 results |
| Test Plans | 100 programmable plans |
| Programmed Locations | Approximately 5,000 |
| User IDs | 200 |
| Display | Backlit LCD |
| Communication Interface | EIA-232 compatible serial interface |
| Software | Hygiena SureTrend desktop software, subject to computer compatibility |
| Power | Two AA batteries |
| Dimensions | 72 x 191 x 32 mm (W x H x D), operator manual |
| Weight | Approximately 260 g, including batteries |
| Operating Temperature | 5°C to 40°C |
| Operating Humidity | 20% to 85% RH, non-condensing |
Data Management and Calibration Verification
SystemSURE Plus can store test results in the instrument and supports transferring data to Hygiena SureTrend desktop software for reviewing and documenting sanitation performance.
The instrument uses a serial interface. Computer connection may require the appropriate cable, USB adapter and drivers. Facilities using newer Windows computers or managed corporate IT systems should confirm software compatibility before ordering.
SystemSURE Plus performs an internal calibration self-check during startup. The optional Hygiena PCD4000 Calibration Control Kit provides an additional method of verifying instrument performance.
Hygiena also offers the CK25 ATP Positive Control Kit for checking ATP test device performance.
Planning Your ATP Testing Program
Before purchasing a luminometer, it helps to identify how your facility will use it. A few practical considerations can make ongoing testing easier and prevent unnecessary consumable purchases.
- Surface or water testing: Determine whether your team needs UltraSnap, AquaSnap Total, AquaSnap Free or a combination.
- Testing frequency: Estimate the number of samples taken daily or weekly to plan your consumable requirements.
- Testing locations: Identify equipment, contact surfaces, rinse-water points and other areas requiring monitoring.
- Documentation: Confirm whether simple stored readings are sufficient or if your team requires centralized reports.
- Calibration verification: Review your internal quality procedures to determine whether additional verification accessories are needed.
- Consumable storage: Review Hygiena's storage and shelf-life instructions for each selected test device.
For repeat testing programs, Cambridge can help estimate ongoing UltraSnap or AquaSnap requirements and discuss purchasing options for Canadian facilities.
Why Buy from Cambridge Environmental?
Cambridge Environmental Products Inc. is a Canadian-owned laboratory equipment and scientific supply distributor serving Canadian customers since 1993.
We work with food and beverage processors, breweries, dairy facilities, industrial QA/QC teams, research laboratories and sanitation professionals across Canada.
Our role is not simply to supply an instrument. We want to help you choose a system that fits your facility, understand the ongoing test requirements and avoid compatibility or purchasing surprises.
If you are introducing ATP testing or replacing an existing system, our team can help you compare SystemSURE Plus, EnSURE Touch and the compatible Hygiena test devices.
Frequently Asked Questions
What is Hygiena SystemSURE Plus used for?
SystemSURE Plus is a handheld ATP luminometer used to verify cleaning effectiveness on surfaces and in compatible water samples. It supports routine hygiene monitoring and sanitation verification programs.
How quickly does SystemSURE Plus provide results?
The instrument provides ATP readings in approximately 15 seconds after a prepared Hygiena test device is inserted and the measurement is started.
What is the difference between SystemSURE Plus and EnSURE Touch?
SystemSURE Plus uses a conventional LCD and keypad and supports desktop data transfer. EnSURE Touch offers a touchscreen, rechargeable battery, Wi-Fi connectivity and SureTrend Cloud integration. Both support ATP hygiene monitoring, but EnSURE Touch offers more extensive data management options.
Which Hygiena ATP swabs work with SystemSURE Plus?
SystemSURE Plus is compatible with Hygiena UltraSnap surface ATP tests and AquaSnap Total and AquaSnap Free water ATP tests. Compatibility with other Hygiena test devices should be confirmed for the specific application.
Are ATP swabs included with SystemSURE Plus?
Do not assume that UltraSnap or AquaSnap consumables are included with the instrument. They are normally ordered separately unless the quoted package specifically includes them.
Can SystemSURE Plus be used for brewery and dairy sanitation?
Yes. Breweries, dairy plants and beverage manufacturers can use SystemSURE Plus with appropriate Hygiena test devices to check cleaned equipment, production surfaces and selected water or rinse-water samples.
Does ATP testing detect bacteria or pathogens?
ATP testing detects an indicator of biological residue and cleaning effectiveness. It does not directly count bacteria or identify specific pathogens. Required microbiological testing must be performed separately.
Does SystemSURE Plus require calibration?
The instrument performs an internal calibration self-check at startup. Hygiena offers the optional PCD4000 Calibration Control Kit for additional verification. Follow the manufacturer's guidance and your facility's quality procedures.
Can I download SystemSURE Plus results to a computer?
Yes. The system supports result transfer to compatible SureTrend desktop software. Computer connection and software compatibility should be confirmed, particularly for newer operating systems.
Can Cambridge help us establish an ATP testing program?
Yes. Cambridge Environmental can help Canadian facilities compare instrument options, select compatible swabs and estimate ongoing testing requirements based on the number of locations and expected testing frequency.
Manufacturer Documents and Product Video
- Hygiena SystemSURE Plus Operator Manual (PDF)
- Hygiena SystemSURE Plus Product Brochure (PDF)
- Hygiena Manufacturer Product Information
Need Help Choosing SystemSURE Plus or EnSURE Touch?
Not sure which Hygiena ATP monitoring system is right for your facility? Cambridge Environmental Products can help Canadian buyers compare SystemSURE Plus, EnSURE Touch, UltraSnap and AquaSnap for food production, breweries, dairy, sanitation and QA/QC workflows.
Contact us before ordering if you need help confirming compatible test devices, software requirements, instrument features or ongoing swab quantities. We can help you choose a practical setup for your testing program.
Contact Cambridge for Hygiena ATP Support