Bürkle Automatic Titrating Burette, 5 to 50 mL
The Bürkle Automatic Titrating Burette is a complete titration set: a borosilicate glass 3.3 burette mounted on a reagent bottle, with Bürkle's original dosing armature. Squeeze the bottle to fill the burette, and it zeroes itself automatically. Then dispense with the press button and finish the titration drop by drop with the micro-screw and fine discharge jet. There's no separate stand, clamp or funnel to set up, and no manual zeroing.
The burettes follow the Dr. Schilling pattern with a Schellbach stripe for easy meniscus reading, with blue graduations to Class B tolerances (DIN EN ISO 385). They come in 5, 10, 15, 25 and 50 mL, and in 15, 25 and 50 mL there's also a version with a plastic shatter-protection sheath. They're used in environmental and water treatment labs, electroplating, food and beverage QA/QC, field analysis, and teaching labs. Bürkle titrating burettes are available in Canada from Cambridge Environmental Products with CAD pricing and Canadian purchasing support.
Ideal For
- Water and wastewater treatment plants: routine titrations such as alkalinity, hardness and chloride
- Electroplating and metal finishing: bath analysis at the line
- Food and beverage QA/QC: acidity and other routine titrations
- Field and mobile analysis where a self-contained set is easier than a burette stand
- Teaching labs, universities and colleges, especially the shatter-protected version
Why Choose a Bürkle Automatic Titrating Burette?
Automatic filling and zeroing
Press the bottle to fill the burette from the reservoir. Excess liquid drains back automatically, so the burette sets to zero every time. That saves time and removes a common source of reading error between titrations.
Precise dosing control
The Bürkle dosing armature lets you dispense quickly with the press button, then titrate drop by drop with the micro-screw. The precise discharge jet produces very fine drops for a sharp end point.
Easy-to-read Schellbach stripe
The Schellbach stripe narrows at the meniscus, making the reading point easy to see. Blue graduations to Class B (DIN EN ISO 385) are printed on borosilicate glass 3.3, which resists chemicals and heat.
Optional shatter protection
The shatter-protected version has a plastic sheath over the glass burette. Bürkle states this makes breakage much less likely, and if the glass does break, the sheath holds back dangerous splinters. It's a good choice for teaching labs, field work and busy benches.
Left- or right-handed use
The armature can be operated with either hand, and the sturdy bottle base keeps the set stable on the bench.
Available Models
Choose the Version, standard or with shatter protection, then the Volume. The shatter-protected version comes in 15, 25 and 50 mL.
| Code | Version | Burette Volume | Division | Tolerance | Overall Height |
|---|---|---|---|---|---|
| 9695-1005 | Standard | 5 mL | 0.05 mL | ± 0.03 mL | 610 mm |
| 9695-1010 | Standard | 10 mL | 0.05 mL | ± 0.045 mL | 560 mm |
| 9695-1015 | Standard | 15 mL | 0.1 mL | ± 0.045 mL | 520 mm |
| 9695-1025 | Standard | 25 mL | 0.1 mL | ± 0.075 mL | 650 mm |
| 9695-1050 | Standard | 50 mL | 0.1 mL | ± 0.075 mL | 920 mm |
| 9695-3015 | Shatter protection | 15 mL | 0.1 mL | ± 0.045 mL | 520 mm |
| 9695-3025 | Shatter protection | 25 mL | 0.1 mL | ± 0.075 mL | 650 mm |
| 9695-3050 | Shatter protection | 50 mL | 0.1 mL | ± 0.075 mL | 920 mm |
Division, tolerance and height are from Bürkle and Bürkle distributor specifications. Published tolerance values vary between sources, so contact Cambridge if you need the figure for a specific model confirmed against the Bürkle certificate.
Which Model Should I Choose?
- 5 or 10 mL: small titrant volumes and low concentrations, where fine 0.05 mL divisions matter.
- 15 or 25 mL: most routine titrations. 25 mL is the common general-purpose size.
- 50 mL: titrations that use larger titrant volumes, so you don't need to refill mid-titration.
- Shatter protection: teaching labs, field use, or anywhere a broken burette would be a hazard.
How to Use
- Fill the reservoir bottle with titrant and fit the burette assembly.
- Squeeze the bottle to fill the burette above the zero mark. The excess drains back, and the burette zeroes automatically.
- Press the button to dispense titrant into the sample.
- Near the end point, use the micro-screw to add titrant drop by drop.
- Read the volume used at the bottom of the meniscus, using the Schellbach stripe.
Always follow the Bürkle operating instructions and your own titration method.
Common Applications
| Application | How It Helps |
|---|---|
| Water and wastewater | Fast, repeatable routine titrations at the plant lab. |
| Electroplating | Bath checks at the line without setting up a burette stand. |
| Food and beverage | Acidity and other routine QC titrations. |
| Field analysis | A self-contained set that is quick to set up and use. |
| Teaching | Simple operation, with an optional shatter-protected version. |
Technical Specifications
| Manufacturer | Bürkle GmbH |
| Burette | Borosilicate glass 3.3, Dr. Schilling pattern, Schellbach stripe |
| Graduation | Blue, Class B (DIN EN ISO 385), adjusted to deliver (Ex) |
| Volumes | 5, 10, 15, 25, 50 mL (shatter-protected: 15, 25, 50 mL) |
| Dosing | Bürkle dosing armature with press button and micro-screw |
| Zeroing | Automatic |
| Reservoir | Bottle included. Bürkle lists 500 mL for the smaller burettes, and distributors list 1000 mL for the 25 and 50 mL |
| Shatter protection (9695-30xx) | Plastic sheathing over the glass burette |
| Wetted materials | Borosilicate glass, PE, PP and an elastomer hose (Bürkle lists natural rubber, NBR or silicone depending on the version) |
| Operation | Left- or right-handed |
| Sold as | Each |
Specifications are from Bürkle product information and distributor listings.
Selection & Handling Notes
- Check chemical resistance. The titrant contacts glass, PE, PP and an elastomer hose. Bürkle advises checking its chemical resistance list before use, especially with strong solvents, oxidizers or concentrated acids.
- Class B, not Class A. These burettes are graduated to Class B tolerances. Where your method requires Class A, use a Class A burette.
- Light-sensitive titrants: the reservoir is clear. Protect light-sensitive reagents from direct light.
- Keep the jet clean. Rinse the burette and jet after use to stop titrant crystallizing and affecting the fine dosing.
- Glass breakage: handle standard glass burettes with care. Choose the shatter-protected version where breakage is a concern.
Canadian Purchasing Support
Cambridge Environmental Products is a Canadian-owned laboratory supply distributor based in Ontario and has served Canadian labs since 1993. We supply Bürkle laboratory products with CAD pricing and shipping across Canada. We work with environmental and water treatment labs, industrial QA/QC labs, food and beverage producers, and universities and colleges, and can help with quotes and choosing the right model. Browse our lab supplies collection for more.
Frequently Asked Questions
How does an automatic titrating burette work?
Squeeze the reservoir bottle to fill the burette. The excess drains back so the burette zeroes itself automatically. Then dispense with the press button and fine-tune with the micro-screw.
What is a Schellbach stripe?
It's a narrow blue stripe on a white background behind the graduations. The meniscus makes it look pinched to a point, so the reading is easier to see and more repeatable.
What accuracy class are these burettes?
Class B, according to DIN EN ISO 385, adjusted to deliver (Ex).
What does shatter protection mean?
The glass burette has a plastic sheath that makes it much harder to break. If it does break, the sheath holds back dangerous splinters.
Is the reservoir bottle included?
Yes. Each burette is supplied as a complete set with the reservoir bottle and Bürkle dosing armature.
Which sizes have shatter protection?
15, 25 and 50 mL (codes 9695-3015, 9695-3025 and 9695-3050).
Are Bürkle titrating burettes available in Canada?
Yes. Cambridge Environmental Products supplies Bürkle titrating burettes across Canada with CAD pricing.
Need Help Choosing a Titrating Burette?
Tell us:
- The titrations you run and the titrant you use
- The titrant volume you usually need
- Whether you need shatter protection
- How many burettes you need
We'll recommend the right model.
Contact Cambridge for Product Support