Brandtech PD-Tip™ II Syringe Tips
Brandtech PD-Tip™ II Syringe Tips
- Secure payments
BRAND PD-Tip™ II Precision Dispenser Tips offer efficient, step-by-step dispensing and enhance the proven features of the classic BRAND PD-Tip™ syringe tips.
Patented size coding means automatic tip volume detection by the HandyStep® touch and HandyStep® electronic. They also fit repeating pipettes from other manufacturers that use standard sized syringe tips. PD-Tip™ II tips are manufactured from virgin polypropylene and high-density polyethylene. Available in non-sterile and BIO-CERT® sterile. BIO-CERT® PD-Tip™ II Precision Dispenser Tips are sterile and certified free of DNA, RNase, endotoxins, and ATP to meet the most stringent sample integrity requirements.
Product Features:
- Available in volumes from 0.1mL to 50mL
- Compatible with most repeater pipettes including the BRAND HandyStep® touch, HandyStep® electronic, and HandyStep® S, Rainin® AutoRep™ E, AutoRep™ S and AutoRep™ M, Gilson® Repetman®, FisherBrand repeating pipette, black-handled Eppendorf® Repeater® 4780, and all other repeating pipettes using standard tips
- High Quality Materials: manufactured entirely from high-quality polyethylene and polypropylene (Piston of 0.1mL tip is liquid crystal polymer-LCP)
- Supplied with a batch Certificate of Performance to document accuracy and precision testing, and help simplify ISO/GLP compliance
PD-Tip™ II Precision Dispenser Tips
Capacity
|
Pack of
|
Non-sterile
Cat. No. |
BIO-CERT® sterile
Cat. No. |
---|---|---|---|
0.1mL
|
100
|
705700
|
705730
|
0.5mL
|
100
|
705702
|
705732
|
1mL
|
100
|
705704
|
705734
|
1.25mL
|
100
|
705706
|
705736
|
2.5mL
|
100
|
705708
|
705738
|
5mL
|
100
|
705710
|
705740
|
10mL
|
100
|
705712
|
705742
|
12.5mL
|
100
|
705714
|
705744
|
25mL
|
50* + 1 adapter
|
705716
|
705746*
|
50mL
|
25 + 1 adapter
|
705718
|
705748
|
Assorted pack (0.5, 1, 1.25, 2.5, 5, 10, and 12.5mL)
|
20/size
|
705720
|
-
|
Adapter for 25mL and 50mL tips, PP, autoclavable
|
|
702398
(Pack of 10) |
702399
(Pack of 5) |
*BIO-CERT®: pack of 25 + 1 adapter
Additional Literature:
BrandTech PD Tip II Syringe Tips Data Sheet
Reference Tables for use with HandyStep®:
HandyStep® S Volume Table with PD-Tip™ II Precision Dispenser Tips
Settings
|
1
|
1.5
|
2
|
2.5
|
3
|
3.5
|
4
|
4.5
|
5
|
---|---|---|---|---|---|---|---|---|---|
Steps
|
49
|
32
|
24
|
19
|
15
|
13
|
11
|
10
|
9
|
PD-Tip™
size |
Volume, µL
|
||||||||
0.1mL
|
2
|
3
|
4
|
5
|
6
|
7
|
8
|
9
|
10
|
0.5mL
|
10
|
15
|
20
|
25
|
30
|
35
|
40
|
45
|
50
|
1.0mL
|
20
|
30
|
40
|
50
|
60
|
70
|
80
|
90
|
100
|
1.25mL
|
25
|
37.5
|
50
|
62.5
|
75
|
87.5
|
100
|
112.5
|
125
|
2.5mL
|
50
|
75
|
100
|
125
|
150
|
175
|
200
|
225
|
250
|
5.0mL
|
100
|
150
|
200
|
250
|
300
|
350
|
400
|
450
|
500
|
10.0mL
|
200
|
300
|
400
|
500
|
600
|
700
|
800
|
900
|
1000
|
12.5mL
|
250
|
375
|
500
|
625
|
750
|
875
|
1000
|
1125
|
1250
|
25.0mL
|
500
|
750
|
1000
|
1250
|
1500
|
1750
|
2000
|
2250
|
2500
|
50.0mL
|
1000
|
1500
|
2000
|
2500
|
3000
|
3500
|
4000
|
4500
|
5000
|
HandyStep® S Accuracy and Precision with PD-Tip™ II Precision Dispenser Tips
PD-Tip™
size |
Volume Range
|
Stroke setting ≡ % of nominal
volume (A* ≤ ± %) |
Stroke setting ≡ % of nominal
volume (CV* ≤ %) |
||||
---|---|---|---|---|---|---|---|
1 ≡ 2%
|
3 ≡ 6%
|
5 ≡ 10%
|
1 ≡ 2%
|
3 ≡ 6%
|
5 ≡ 10%
|
||
0.1mL
|
2µL-10µL
|
4.0
|
2.4
|
1.6
|
6.0
|
3.0
|
2.0
|
0.5mL
|
10µL-50µL
|
2.5
|
1.5
|
1.0
|
2.5
|
1.5
|
1.0
|
1.0mL
|
20µL-100µL
|
2.5
|
1.5
|
1.0
|
2.0
|
1.2
|
0.8
|
1.25mL
|
25µL-125µL
|
2.5
|
1.4
|
0.9
|
2.0
|
1.1
|
0.7
|
2.5mL
|
50µL-250µL
|
1.8
|
1.1
|
0.7
|
1.5
|
0.9
|
0.6
|
5.0mL
|
100µL-500µL
|
1.8
|
1.1
|
0.7
|
1.5
|
0.9
|
0.7
|
10.0mL
|
200µL-1000µL
|
1.8
|
1.1
|
0.7
|
2.0
|
1.2
|
0.8
|
12.5mL
|
250µL-1250µL
|
1.8
|
1.1
|
0.8
|
3.2
|
2.0
|
1.4
|
25.0mL
|
500µL-2500µL
|
1.5
|
0.9
|
0.6
|
3.04
|
1.5
|
1.0
|
50.0mL
|
1000µL-5000µL
|
1.5
|
0.8
|
0.5
|
5.0
|
1.8
|
1.2
|
HandyStep® touch/touch S Accuracy and Precision with PD-Tip™ II Precision Dispenser Tips
PD-Tip™
size |
Volume
Range |
Increment
|
Nominal volume (A* ≤ ± %)
|
Nominal volume (CV* ≤ %)
|
||||||
---|---|---|---|---|---|---|---|---|---|---|
100%
|
50%
|
10%
|
1%
|
100%
|
50%
|
10%
|
1%
|
|||
0.1mL
|
1µL-100µL
|
0.1µL
|
1
|
1
|
1.6
|
8
|
0.5
|
1
|
2
|
12
|
0.5mL
|
5µL-500µL
|
0.5µL
|
0.9
|
0.9
|
1
|
5
|
0.3
|
0.6
|
1
|
5
|
1.0mL
|
10µL-1.0mL
|
1µL
|
0.6
|
0.9
|
1
|
5
|
0.3
|
0.5
|
0.8
|
4
|
1.25mL
|
12.5µL-1.25mL
|
1.25µL
|
0.6
|
0.6
|
0.9
|
5
|
0.2
|
0.5
|
0.7
|
4
|
2.5mL
|
25µL-2.5mL
|
2.5µL
|
0.5
|
0.6
|
0.7
|
3.5
|
0.15
|
0.3
|
0.6
|
3
|
5.0mL
|
50µL-5.0mL
|
5µL
|
0.5
|
0.5
|
0.7
|
3.5
|
0.15
|
0.4
|
0.7
|
3
|
10.0mL
|
100µL-10mL
|
10µL
|
0.4
|
0.5
|
0.7
|
3.5
|
0.15
|
0.5
|
0.8
|
4
|
12.5mL
|
125µL-12.5mL
|
12.5µL
|
0.5
|
0.5
|
0.8
|
3.5
|
0.15
|
0.6
|
1.4
|
6.5
|
25.0mL
|
250µL-25mL
|
25µL
|
0.5
|
0.5
|
0.6
|
3
|
0.15
|
0.3
|
1.0
|
6
|
50.0mL
|
500µL-50mL
|
50µL
|
0.5
|
0.5
|
0.5
|
3
|
0.15
|
0.4
|
1.2
|
9
|
A*=Accuracy, CV*=Coefficient of Variation
*Error limits refer to the nominal and partial volumes relative to the PD-Tip™ II obtained with instrument and distilled water at equilibrium with ambient temperature at 20° C and with smooth operation. The error limits defined in ISO 8655 are not exceeded.
The nominal volume is the maximum volume which is printed on the PD-Tip™ II