The OHAUS PR523N is a 520 g precision balance with 0.001 g displayed readability designed for routine laboratory weighing and approved legal-for-trade applications in Canada. It combines a compact glass draftshield, RS-232 connectivity and OHAUS InCal internal calibration with Class II type approval.

For Canadian legal-for-trade applications, the distinction between display readability and approved weighing resolution is important: the PR523N displays to 0.001 g, while its verification scale interval is 0.01 g.

Ideal Applications

  • Canadian businesses requiring an approved precision balance for commercial transactions
  • Cannabis production and retail weighing applications where an approved balance is required
  • Pharmacy and formulation weighing
  • Laboratory and industrial quality-control weighing
  • Small-component and ingredient weighing
  • Routine weighing where 520 g capacity and milligram-level display resolution are useful

OHAUS PR523N at a Glance

Model PR523N
OHAUS Part Number 30452494
Maximum Capacity 520 g
Displayed Readability 0.001 g
Verification Scale Interval 0.01 g
Metrological Class Class II
Calibration OHAUS InCal internal calibration system*
Legal for Trade Type approved for applicable Canadian trade applications; final verification and sealing requirements apply
Important for Canadian legal-for-trade use: The PR523N can display weight to 0.001 g, but its approved verification interval is 0.01 g. OHAUS documentation also specifies that internal calibration must be disabled when the balance is used for trade in Canada. The balance must be correctly configured, verified and sealed for legal-for-trade service. Contact Cambridge before ordering if the balance will be used for commercial transactions.

Why Choose the PR523N?

520 g Capacity with 0.001 g Display Readability

The PR523N provides a useful combination of relatively high capacity and milligram-level displayed resolution. It is well suited to samples and components that need considerably more capacity than a small analytical balance while still requiring fine weight indication.

Designed for Approved Weighing Applications

The PR523N belongs to OHAUS's type-approved PR Series. It is a Class II instrument intended for applications where an approved weighing device may be required.

For trade use, buyers should select a balance according to its verification interval, not simply the smallest digit shown on the display. On the PR523N, the verification interval is 0.01 g.

OHAUS InCal

The PR523N incorporates OHAUS InCal internal calibration for normal balance calibration and adjustment. This can simplify routine laboratory operation where the balance is not being operated under Canadian legal-for-trade restrictions.

Canadian legal-for-trade operation is different. OHAUS specifies that internal calibration must be disabled when the PR523N is configured for trade use in Canada.

Glass Draftshield

The enclosed weighing area helps reduce the influence of drafts and air movement when weighing at 0.001 g readability. This becomes increasingly important as sample weights decrease.

RS-232 Data Connection

A standard RS-232 interface allows the balance to communicate with compatible printers, computers and data systems. Optional interface solutions may be available where USB or Ethernet connectivity is required.

Technical Specifications

Specification PR523N
Maximum capacity 520 g
Readability 0.001 g
Verification interval (e) 0.01 g
Class II
Repeatability, standard deviation 0.001 g
Linearity ±0.002 g
Typical stabilization time 2 seconds
Typical USP minimum weight 2 g
Optimized minimum weight 0.82 g*
Pan diameter 120 mm / 4.7 in
Draftshield Included
Display Backlit LCD
Communications RS-232
Calibration system OHAUS InCal
Balance dimensions 201 × 317 × 303 mm (W × D × H)
Net weight 4.5 kg / 10 lb
Power AC power adapter

*Minimum-weight values published by OHAUS are performance references under specified conditions and should not be treated as a substitute for a laboratory's own minimum-weight assessment or regulatory requirements.


Documents & Canadian Approval

  • OHAUS PR Series Data Sheet: Product specifications, capacities, readability and verification intervals.
  • OHAUS PR Series Instruction Manual: Setup, operation, calibration, approved mode and maintenance information.
  • Measurement Canada Approval: AM-6101

Weighing Functions

  • Basic weighing
  • Parts counting
  • Percent weighing

Some functions may not be permitted for commercial transactions when the balance is operating in approved mode. The balance should be configured according to the applicable Canadian weights-and-measures requirements.

PR523N vs. PR523N/E

Cambridge offers two closely related 520 g PR models. The main difference is the calibration system.

Model PR523N PR523N/E
Capacity 520 g 520 g
Displayed readability 0.001 g 0.001 g
Verification interval 0.01 g 0.01 g
Calibration InCal internal system External calibration
OHAUS part number 30452494 30455606

If internal calibration is not required, see the OHAUS PR523N/E 520 g × 0.001 g Legal-for-Trade Precision Balance.

Choosing the PR523N for Legal-for-Trade Use in Canada

A Measurement Canada-approved model is only one part of putting a weighing device into legal-for-trade service. The instrument must also be correctly configured, verified and sealed in accordance with applicable requirements.

If you are purchasing the PR523N for commercial transactions, tell Cambridge how the balance will be used and where it will ultimately be installed. We can help confirm the appropriate model and discuss the verification requirements before you order.

Calibration note: Do not assume that the PR523N's InCal function can continue to be used normally once the balance is configured and sealed for Canadian legal-for-trade service. OHAUS documentation specifies that internal calibration is to be disabled for trade use in Canada.

Frequently Asked Questions

Is the OHAUS PR523N legal for trade in Canada?

It is a type-approved OHAUS PR Series balance intended for legal-for-trade applications in Canada. The individual balance must still be correctly configured, verified and sealed before being placed into applicable commercial service.

Does the PR523N weigh to 0.001 g when used for trade?

The balance can display to 0.001 g, but its verification scale interval for approved applications is 0.01 g. Buyers should use the 0.01 g verification interval when assessing suitability for a legal-for-trade application.

Does the PR523N have internal calibration?

Yes. The PR523N is the InCal version of the 520 g PR balance. However, OHAUS specifies that internal calibration must be disabled when the balance is used for trade in Canada.

Can I calibrate the PR523N myself after it has been verified and sealed?

Not in the same way as a normal non-approved laboratory balance. Approved mode restricts access to legally controlled calibration and configuration functions. If the balance is being used for trade, contact Cambridge or your authorized service provider before making calibration or configuration changes that could affect its verification or seal.

What is the difference between PR523N and PR523N/E?

Both have 520 g capacity and 0.001 g displayed readability. The PR523N incorporates OHAUS InCal, while the PR523N/E is the externally calibrated version.

Does the PR523N include a draftshield?

Yes. The 0.001 g PR523N uses a glass draftshield around the weighing pan to help reduce the effects of air movement during precision weighing.

Can the PR523N connect to a printer or computer?

Yes. The balance includes an RS-232 communication interface. Optional interface equipment may be available for other communication requirements.

Is the PR523N suitable for very small samples?

That depends on the required uncertainty and application. OHAUS publishes a typical USP minimum weight of 2 g and an optimized minimum-weight reference of 0.82 g for this model. Laboratories with regulated minimum-weight requirements should establish suitability using their own procedures and calibration data.

Canadian Sales and Support

Cambridge Environmental Products supplies weighing equipment to Canadian laboratories, universities, manufacturers and regulated facilities. If the PR523N will be used for a commercial transaction, tell us before ordering so we can help confirm whether this model and its 0.01 g verification interval are suitable for your application.

Need Help Choosing the Correct Approved Balance?

Tell us what you are weighing, the typical sample weight, required resolution and whether the weight will determine a selling price. Cambridge can help you compare the PR523N with other approved OHAUS and A&D balances before you order.

Contact Cambridge

The OHAUS PR523N is a 520 g precision balance with 0.001 g displayed readability designed for routine laboratory weighing and approved legal-for-trade applications in Canada. It combines a compact glass draftshield, RS-232 connectivity and OHAUS InCal internal calibration with Class II type approval.

For Canadian legal-for-trade applications, the distinction between display readability and approved weighing resolution is important: the PR523N displays to 0.001 g, while its verification scale interval is 0.01 g.

Ideal Applications

  • Canadian businesses requiring an approved precision balance for commercial transactions
  • Cannabis production and retail weighing applications where an approved balance is required
  • Pharmacy and formulation weighing
  • Laboratory and industrial quality-control weighing
  • Small-component and ingredient weighing
  • Routine weighing where 520 g capacity and milligram-level display resolution are useful

OHAUS PR523N at a Glance

Model PR523N
OHAUS Part Number 30452494
Maximum Capacity 520 g
Displayed Readability 0.001 g
Verification Scale Interval 0.01 g
Metrological Class Class II
Calibration OHAUS InCal internal calibration system*
Legal for Trade Type approved for applicable Canadian trade applications; final verification and sealing requirements apply
Important for Canadian legal-for-trade use: The PR523N can display weight to 0.001 g, but its approved verification interval is 0.01 g. OHAUS documentation also specifies that internal calibration must be disabled when the balance is used for trade in Canada. The balance must be correctly configured, verified and sealed for legal-for-trade service. Contact Cambridge before ordering if the balance will be used for commercial transactions.

Why Choose the PR523N?

520 g Capacity with 0.001 g Display Readability

The PR523N provides a useful combination of relatively high capacity and milligram-level displayed resolution. It is well suited to samples and components that need considerably more capacity than a small analytical balance while still requiring fine weight indication.

Designed for Approved Weighing Applications

The PR523N belongs to OHAUS's type-approved PR Series. It is a Class II instrument intended for applications where an approved weighing device may be required.

For trade use, buyers should select a balance according to its verification interval, not simply the smallest digit shown on the display. On the PR523N, the verification interval is 0.01 g.

OHAUS InCal

The PR523N incorporates OHAUS InCal internal calibration for normal balance calibration and adjustment. This can simplify routine laboratory operation where the balance is not being operated under Canadian legal-for-trade restrictions.

Canadian legal-for-trade operation is different. OHAUS specifies that internal calibration must be disabled when the PR523N is configured for trade use in Canada.

Glass Draftshield

The enclosed weighing area helps reduce the influence of drafts and air movement when weighing at 0.001 g readability. This becomes increasingly important as sample weights decrease.

RS-232 Data Connection

A standard RS-232 interface allows the balance to communicate with compatible printers, computers and data systems. Optional interface solutions may be available where USB or Ethernet connectivity is required.

Technical Specifications

Specification PR523N
Maximum capacity 520 g
Readability 0.001 g
Verification interval (e) 0.01 g
Class II
Repeatability, standard deviation 0.001 g
Linearity ±0.002 g
Typical stabilization time 2 seconds
Typical USP minimum weight 2 g
Optimized minimum weight 0.82 g*
Pan diameter 120 mm / 4.7 in
Draftshield Included
Display Backlit LCD
Communications RS-232
Calibration system OHAUS InCal
Balance dimensions 201 × 317 × 303 mm (W × D × H)
Net weight 4.5 kg / 10 lb
Power AC power adapter

*Minimum-weight values published by OHAUS are performance references under specified conditions and should not be treated as a substitute for a laboratory's own minimum-weight assessment or regulatory requirements.


Documents & Canadian Approval

  • OHAUS PR Series Data Sheet: Product specifications, capacities, readability and verification intervals.
  • OHAUS PR Series Instruction Manual: Setup, operation, calibration, approved mode and maintenance information.
  • Measurement Canada Approval: AM-6101

Weighing Functions

  • Basic weighing
  • Parts counting
  • Percent weighing

Some functions may not be permitted for commercial transactions when the balance is operating in approved mode. The balance should be configured according to the applicable Canadian weights-and-measures requirements.

PR523N vs. PR523N/E

Cambridge offers two closely related 520 g PR models. The main difference is the calibration system.

Model PR523N PR523N/E
Capacity 520 g 520 g
Displayed readability 0.001 g 0.001 g
Verification interval 0.01 g 0.01 g
Calibration InCal internal system External calibration
OHAUS part number 30452494 30455606

If internal calibration is not required, see the OHAUS PR523N/E 520 g × 0.001 g Legal-for-Trade Precision Balance.

Choosing the PR523N for Legal-for-Trade Use in Canada

A Measurement Canada-approved model is only one part of putting a weighing device into legal-for-trade service. The instrument must also be correctly configured, verified and sealed in accordance with applicable requirements.

If you are purchasing the PR523N for commercial transactions, tell Cambridge how the balance will be used and where it will ultimately be installed. We can help confirm the appropriate model and discuss the verification requirements before you order.

Calibration note: Do not assume that the PR523N's InCal function can continue to be used normally once the balance is configured and sealed for Canadian legal-for-trade service. OHAUS documentation specifies that internal calibration is to be disabled for trade use in Canada.

Frequently Asked Questions

Is the OHAUS PR523N legal for trade in Canada?

It is a type-approved OHAUS PR Series balance intended for legal-for-trade applications in Canada. The individual balance must still be correctly configured, verified and sealed before being placed into applicable commercial service.

Does the PR523N weigh to 0.001 g when used for trade?

The balance can display to 0.001 g, but its verification scale interval for approved applications is 0.01 g. Buyers should use the 0.01 g verification interval when assessing suitability for a legal-for-trade application.

Does the PR523N have internal calibration?

Yes. The PR523N is the InCal version of the 520 g PR balance. However, OHAUS specifies that internal calibration must be disabled when the balance is used for trade in Canada.

Can I calibrate the PR523N myself after it has been verified and sealed?

Not in the same way as a normal non-approved laboratory balance. Approved mode restricts access to legally controlled calibration and configuration functions. If the balance is being used for trade, contact Cambridge or your authorized service provider before making calibration or configuration changes that could affect its verification or seal.

What is the difference between PR523N and PR523N/E?

Both have 520 g capacity and 0.001 g displayed readability. The PR523N incorporates OHAUS InCal, while the PR523N/E is the externally calibrated version.

Does the PR523N include a draftshield?

Yes. The 0.001 g PR523N uses a glass draftshield around the weighing pan to help reduce the effects of air movement during precision weighing.

Can the PR523N connect to a printer or computer?

Yes. The balance includes an RS-232 communication interface. Optional interface equipment may be available for other communication requirements.

Is the PR523N suitable for very small samples?

That depends on the required uncertainty and application. OHAUS publishes a typical USP minimum weight of 2 g and an optimized minimum-weight reference of 0.82 g for this model. Laboratories with regulated minimum-weight requirements should establish suitability using their own procedures and calibration data.

Canadian Sales and Support

Cambridge Environmental Products supplies weighing equipment to Canadian laboratories, universities, manufacturers and regulated facilities. If the PR523N will be used for a commercial transaction, tell us before ordering so we can help confirm whether this model and its 0.01 g verification interval are suitable for your application.

Need Help Choosing the Correct Approved Balance?

Tell us what you are weighing, the typical sample weight, required resolution and whether the weight will determine a selling price. Cambridge can help you compare the PR523N with other approved OHAUS and A&D balances before you order.

Contact Cambridge
Recently viewed