A&D AX-43 Moisture Analyzer Temperature Calibrator

SKU: AX-43
A&D AX-43 Moisture Analyzer Temperature Calibrator

A&D AX-43 Moisture Analyzer Temperature Calibrator

SKU: AX-43
Regular price $960.67 CAD
/
  • Secure payments
Shipping calculated at checkout.

A&D AX-43 Moisture Analyzer Temperature Calibrator

The A&D AX-43 Temperature Calibrator is designed for checking and adjusting the drying temperature of A&D MS-70 and MX-50 moisture analyzers. It uses a digital thermometer and a sensor pan to measure the temperature inside the analyzer during the calibration procedure.

For Canadian food QA/QC laboratories, research facilities and industrial testing labs, the AX-43 helps support consistent moisture testing and documented instrument maintenance.

Key Features

  • Designed for A&D MS-70 and MX-50: Manufacturer-listed temperature calibration accessory.
  • Two-point calibration: Used with the moisture analyzer's built-in calibration procedure at 100°C and 160°C.
  • Direct temperature measurement: K-type thermocouple sensor measures temperature at the sample pan position.
  • Digital thermometer: Provides the measured temperature for entry into the moisture analyzer.
  • Supports laboratory quality control: Useful when checking and documenting drying temperature performance.

Ideal Applications

Food and beverage quality control, pharmaceutical and chemical laboratories, university research, industrial moisture analysis and laboratories maintaining documented moisture analyzer calibration procedures.

Compatibility: AX-43 is specified for A&D MS-70 and MX-50 moisture analyzers. Do not assume compatibility with MF-50, ML-50 or newer A&D moisture analyzer models. Contact Cambridge to confirm your exact instrument before ordering.

Product Details

How Does Temperature Calibration Work?

The sensor pan is placed inside the compatible moisture analyzer, replacing the normal sample pan. The analyzer runs its temperature calibration procedure at 100°C and 160°C.

The operator reads the measured temperature from the AX-43 thermometer and enters that value into the moisture analyzer.

Each calibration point takes approximately 15 minutes. The analyzer provides an audible signal when the measurement stage is complete.

Follow the instructions for your exact moisture analyzer model. The AX-43 does not automatically adjust the instrument without operator input.

Technical Specifications
Manufacturer A&D Weighing
Product SKU AX-43
Application Moisture analyzer drying temperature calibration
Compatible Models MS-70 and MX-50
Calibration Points 100°C and 160°C
Temperature Sensor K-type thermocouple
Sensor Measurement Range 0°C to 200°C, per referenced MX-43 documentation
Thermometer Resolution 0.1°C or 1°C, per referenced MX-43 documentation
Power 9 V battery, per referenced MX-43 documentation

The linked instruction manual uses the older MX-43 designation. Confirm the current AX-43 kit revision, supplied components and accompanying documentation before ordering.

Temperature Calibration vs. Moisture Accuracy Checks

These procedures check different parts of the moisture analysis process.

  • Temperature calibration: The AX-43 measures the drying temperature and supports adjustment of the moisture analyzer's heating system.
  • Weight calibration: Uses an appropriate calibration mass to check or adjust the weighing system.
  • Moisture performance checks: Use a reference material, such as sodium tartrate dihydrate, to check moisture measurement performance.

A reference sample does not replace temperature calibration. Laboratories should choose the procedures appropriate to their quality requirements.

Compatible A&D Moisture Analyzers

The AX-43 is intended for the following A&D instruments:

Browse Cambridge's Moisture Analyzer Accessories for sample pans, glass fibre sheets and other available A&D accessories.

Frequently Asked Questions

What is the A&D AX-43 used for?

The AX-43 measures the drying temperature inside compatible A&D moisture analyzers and supports their temperature calibration procedure.

Which moisture analyzers are compatible?

A&D identifies the MS-70 and MX-50 as compatible models. Confirm compatibility before purchasing for any other instrument.

What temperatures are used for calibration?

The MS-70 and MX-50 temperature calibration procedure uses 100°C and 160°C measurement points.

How long does temperature calibration take?

Each measurement stage takes approximately 15 minutes. Allow additional time for setup, stabilization and completion of the manufacturer's procedure.

Does the AX-43 calibrate the weighing system?

No. It is used for drying temperature calibration. Weight calibration requires an appropriate calibration mass and the moisture analyzer's weighing calibration procedure.

Can I use sodium tartrate instead?

Sodium tartrate dihydrate can be used for a moisture performance check. It does not directly calibrate the drying temperature sensor.

Does the AX-43 include a calibration certificate?

Certificate requirements should be confirmed before purchasing. Contact Cambridge if your laboratory requires traceability documentation or a specific certificate for its quality management procedures.

Can Cambridge supply this calibrator in Canada?

Cambridge Environmental supplies A&D laboratory weighing equipment and accessories to Canadian customers. Contact us to confirm current AX-43 pricing, availability and documentation requirements.

Manufacturer Documentation

A&D Temperature Calibrator Instruction Manual (PDF)

A&D Moisture Analyzers and Accessories

Need Help with A&D Moisture Analyzer Calibration?

Not sure whether the AX-43 is compatible with your moisture analyzer? Cambridge Environmental can help Canadian laboratories confirm the correct accessory, manufacturer documentation and available calibration options.

Contact us with your moisture analyzer model and any calibration or documentation requirements before ordering.

Contact Cambridge for A&D Support
Recently viewed