{"product_id":"settleometer-kit-sv30-ssv-canada","title":"Settleometer Kit for SV30 (SSV) Settling Test – Wastewater","description":"\u003cp style=\"text-align: center;\" data-end=\"207\" data-start=\"185\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eSettleometer Kit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"2714\" data-start=\"2651\"\u003e\u003cstrong data-end=\"2714\" data-start=\"2651\"\u003eSettleometer Kit (SV30 \/ SSV) for Activated Sludge – Canada\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-end=\"3121\" data-start=\"2716\"\u003eThe Settleometer Kit is a fast, operator-friendly tool for measuring \u003cstrong data-end=\"2814\" data-start=\"2785\"\u003eSV30 settling performance\u003c\/strong\u003e and \u003cstrong data-end=\"2850\" data-start=\"2819\"\u003eSettled Sludge Volume (SSV)\u003c\/strong\u003e in activated sludge systems. It helps wastewater operators quickly see how solids separate from liquid over time—supporting better day-to-day control of \u003cstrong data-end=\"3028\" data-start=\"3004\"\u003esecondary clarifiers\u003c\/strong\u003e, solids inventory, and overall biological performance. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"3457\" data-start=\"3123\"\u003e\u003cstrong data-end=\"3156\" data-start=\"3123\"\u003eDual-scale readings (SSV + %)\u003c\/strong\u003e\u003cbr data-end=\"3159\" data-start=\"3156\"\u003eLarge, easy-to-read markings show \u003cstrong data-end=\"3215\" data-start=\"3193\"\u003eSSV from 0–1000 mL\u003c\/strong\u003e and \u003cstrong data-end=\"3245\" data-start=\"3220\"\u003e0–100% settled volume\u003c\/strong\u003e, making it simple to record SV30 results consistently across shifts. A \u003cstrong data-end=\"3332\" data-start=\"3317\"\u003esnap-on lid\u003c\/strong\u003e reduces splashing during transport from the aeration basin to the lab or control room. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"3483\" data-start=\"3459\"\u003e\u003cstrong data-end=\"3483\" data-start=\"3459\"\u003eWhy operators use it\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"3760\" data-start=\"3484\"\u003e\n\u003cli data-end=\"3570\" data-start=\"3484\"\u003e\n\u003cp data-end=\"3570\" data-start=\"3486\"\u003eSpot \u003cstrong data-end=\"3527\" data-start=\"3491\"\u003erapid vs normal vs slow settling\u003c\/strong\u003e before it becomes a clarifier loss event\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3653\" data-start=\"3571\"\u003e\n\u003cp data-end=\"3653\" data-start=\"3573\"\u003eSupport process decisions (RAS\/WAS adjustments, settleability troubleshooting)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3760\" data-start=\"3654\"\u003e\n\u003cp data-end=\"3760\" data-start=\"3656\"\u003eCompare settling behaviour over time or between basins (including dilution comparisons where applicable)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"3804\" data-start=\"3762\"\u003e\u003cstrong data-end=\"3804\" data-start=\"3762\"\u003eHow to run an SV30 settle test (quick)\u003c\/strong\u003e\u003c\/p\u003e\n\u003col data-end=\"3932\" data-start=\"3805\"\u003e\n\u003cli data-end=\"3848\" data-start=\"3805\"\u003e\n\u003cp data-end=\"3848\" data-start=\"3808\"\u003eFill to 1000 mL with well-mixed sample\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3888\" data-start=\"3849\"\u003e\n\u003cp data-end=\"3888\" data-start=\"3852\"\u003eStart timer; let settle 30 minutes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3932\" data-start=\"3889\"\u003e\n\u003cp data-end=\"3932\" data-start=\"3892\"\u003eRecord SV30 as \u003cstrong data-end=\"3919\" data-start=\"3907\"\u003eSSV (mL)\u003c\/strong\u003e and\/or \u003cstrong data-end=\"3932\" data-start=\"3927\"\u003e%\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp data-end=\"4110\" data-start=\"3934\"\u003e \u003c\/p\u003e\n\u003cp data-end=\"1474\" data-start=\"1448\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"2093\" data-start=\"1476\"\u003e\n\u003cli data-end=\"1555\" data-start=\"1476\"\u003e\n\u003cp data-end=\"1555\" data-start=\"1478\"\u003eClearly measures \u003cstrong data-end=\"1526\" data-start=\"1495\"\u003esettled sludge volume (SSV)\u003c\/strong\u003e and percent settled volume\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1635\" data-start=\"1556\"\u003e\n\u003cp data-end=\"1635\" data-start=\"1558\"\u003e\u003cstrong data-end=\"1581\" data-start=\"1558\"\u003eDual-scale markings\u003c\/strong\u003e from 0–100% and 0–1000 SSV for quick interpretation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1714\" data-start=\"1636\"\u003e\n\u003cp data-end=\"1714\" data-start=\"1638\"\u003eHelps evaluate \u003cstrong data-end=\"1688\" data-start=\"1653\"\u003esludge settling characteristics\u003c\/strong\u003e in secondary clarifiers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1805\" data-start=\"1715\"\u003e\n\u003cp data-end=\"1805\" data-start=\"1717\"\u003eSupports \u003cstrong data-end=\"1755\" data-start=\"1726\"\u003eprocess control decisions\u003c\/strong\u003e, including return sludge flow rate calculations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1875\" data-start=\"1806\"\u003e\n\u003cp data-end=\"1875\" data-start=\"1808\"\u003eUseful for identifying \u003cstrong data-end=\"1873\" data-start=\"1831\"\u003erapid, normal, or slow settling sludge\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1962\" data-start=\"1876\"\u003e\n\u003cp data-end=\"1962\" data-start=\"1878\"\u003eEnables \u003cstrong data-end=\"1912\" data-start=\"1886\"\u003emulti-dilution testing\u003c\/strong\u003e to distinguish density vs. concentration issues\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2024\" data-start=\"1963\"\u003e\n\u003cp data-end=\"2024\" data-start=\"1965\"\u003e\u003cstrong data-end=\"1980\" data-start=\"1965\"\u003eSnap-on lid\u003c\/strong\u003e reduces splashing during sample transport\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2093\" data-start=\"2025\"\u003e\n\u003cp data-end=\"2093\" data-start=\"2027\"\u003eSimple, durable design suitable for routine wastewater plant use\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp data-end=\"4281\" data-start=\"4274\"\u003e\u003cstrong data-end=\"4281\" data-start=\"4274\"\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003col data-end=\"5557\" data-start=\"4282\"\u003e\n\u003cli data-end=\"4480\" data-start=\"4282\"\u003e\n\u003cp data-end=\"4480\" data-start=\"4285\"\u003e\u003cstrong data-end=\"4308\" data-start=\"4285\"\u003eWhat is SV30 \/ SSV?\u003c\/strong\u003e\u003cbr data-end=\"4311\" data-start=\"4308\"\u003eSV30 is the settled sludge volume after 30 minutes. SSV is the settled volume reading (commonly recorded in mL at 30 minutes). \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"4696\" data-start=\"4481\"\u003e\n\u003cp data-end=\"4696\" data-start=\"4484\"\u003e\u003cstrong data-end=\"4539\" data-start=\"4484\"\u003eWhy does the Settleometer show both % and SSV (mL)?\u003c\/strong\u003e\u003cbr data-end=\"4542\" data-start=\"4539\"\u003eThe dual scale lets you record results in either format for easier trending and communication across operators. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"4890\" data-start=\"4697\"\u003e\n\u003cp data-end=\"4890\" data-start=\"4700\"\u003e\u003cstrong data-end=\"4727\" data-start=\"4700\"\u003eWhere do I sample from?\u003c\/strong\u003e\u003cbr data-end=\"4730\" data-start=\"4727\"\u003eMost plants use a well-mixed sample from the \u003cstrong data-end=\"4809\" data-start=\"4778\"\u003eaeration basin mixed liquor\u003c\/strong\u003e (or wherever your SV30 SOP specifies). \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"5097\" data-start=\"4891\"\u003e\n\u003cp data-end=\"5097\" data-start=\"4894\"\u003e\u003cstrong data-end=\"4930\" data-start=\"4894\"\u003eDo I only read it at 30 minutes?\u003c\/strong\u003e\u003cbr data-end=\"4933\" data-start=\"4930\"\u003eSV30 is standard, but many operators also take 5-minute readings early on to see settling behaviour (a settling curve). \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"5318\" data-start=\"5098\"\u003e\n\u003cp data-end=\"5318\" data-start=\"5101\"\u003e\u003cstrong data-end=\"5148\" data-start=\"5101\"\u003eIs this the Raven C-10102 Settleometer kit?\u003c\/strong\u003e\u003cbr data-end=\"5151\" data-start=\"5148\"\u003eYour SKU shows \u003cstrong data-end=\"5180\" data-start=\"5169\"\u003eC-10102\u003c\/strong\u003e—call out the manufacturer\/brand explicitly on the page if it’s Raven to capture brand searches. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"5557\" data-start=\"5319\"\u003e\n\u003cp data-end=\"5557\" data-start=\"5322\"\u003e\u003cstrong data-end=\"5366\" data-start=\"5322\"\u003eCan this help diagnose clarifier issues?\u003c\/strong\u003e\u003cbr data-end=\"5369\" data-start=\"5366\"\u003eYes—settling behaviour trends are commonly used to flag developing settleability and solids separation problems before they show up as carryover. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp data-end=\"2093\" data-start=\"2027\"\u003e\u003cbr\u003e\u003cstrong data-end=\"2785\" data-start=\"2766\"\u003e\u003c\/strong\u003e\u003cstrong data-end=\"3957\" data-start=\"3934\"\u003eShips within Canada\u003c\/strong\u003e\u003cbr data-end=\"3960\" data-start=\"3957\"\u003eSold and supported by Cambridge Environmental Products (Ontario). Add this to your activated sludge bench tools for consistent settleability tracking.\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"RavenEP","offers":[{"title":"Default","offer_id":47687599456515,"sku":"C-10102","price":123.3,"currency_code":"CAD","in_stock":true},{"title":"Default (Wholesale)","offer_id":47687599489283,"sku":"C-10102","price":112.09,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/Settleometer.jpg?v=1769541234","url":"https:\/\/cambridgeenviro.com\/products\/settleometer-kit-sv30-ssv-canada","provider":"Cambridge Environmental Products, Inc.","version":"1.0","type":"link"}