{"product_id":"products-ohaus-mb32-90g-x-0-001g-moisture-analyzer","title":"OHAUS MB32 Moisture Analyzer – 90 g x 0.001 g","description":"\u003ch2\u003eOHAUS MB32 Moisture Analyzer – 90 g x 0.001 g\u003c\/h2\u003e\n\n\u003cp\u003e\n  The \u003cstrong\u003eOHAUS MB32 Moisture Analyzer\u003c\/strong\u003e is designed for fast, routine moisture-content testing in laboratories and QA\/QC environments that need a practical alternative to lengthy oven-drying procedures.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  Combining a \u003cstrong\u003e90 g precision balance with 0.001 g readability\u003c\/strong\u003e and an integrated \u003cstrong\u003ecarbon-fibre infrared heating system\u003c\/strong\u003e, the MB32 continuously measures sample weight as moisture is driven off. At the end of the drying cycle, results can be displayed as \u003cstrong\u003e% moisture, % solids, % regain, weight, time, and temperature\u003c\/strong\u003e.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  With a \u003cstrong\u003e40°C to 180°C heating range\u003c\/strong\u003e, two drying profiles, automatic and timed shutoff options, two stored methods, and RS232\/USB communication, the MB32 is a strong fit for Canadian laboratories performing routine moisture testing without requiring the expanded method management and data-storage features of the MB62 or MB92.\n\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n  \u003ch3 style=\"margin-top:0; font-size:18px; line-height:1.35;\"\u003eBest Fit for Routine Moisture Testing\u003c\/h3\u003e\n  \u003cul style=\"margin-bottom:0;\"\u003e\n    \u003cli\u003eFood and beverage QA\/QC\u003c\/li\u003e\n    \u003cli\u003eAgricultural and feed-related sample testing\u003c\/li\u003e\n    \u003cli\u003eIngredient and raw-material moisture checks\u003c\/li\u003e\n    \u003cli\u003eChemical and industrial quality control\u003c\/li\u003e\n    \u003cli\u003eResearch and product-development laboratories\u003c\/li\u003e\n    \u003cli\u003eEnvironmental and materials testing\u003c\/li\u003e\n    \u003cli\u003eRoutine production-floor moisture verification\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eWhy Choose the OHAUS MB32?\u003c\/h2\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n    \u003cstrong\u003e0.001 g \/ 0.01% readability:\u003c\/strong\u003e\n    Provides substantially more useful moisture-analysis resolution than a basic 0.01 g moisture balance.\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003e90 g maximum capacity:\u003c\/strong\u003e\n    Provides flexibility for routine analytical samples while maintaining 1 mg weighing readability.\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eCarbon-fibre heating technology:\u003c\/strong\u003e\n    OHAUS uses a responsive carbon-fibre infrared heating system designed to reach operating temperature quickly and support shorter analysis times.\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003e40°C to 180°C temperature range:\u003c\/strong\u003e\n    Temperature can be set in 1°C increments to develop drying conditions appropriate for different sample types.\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eStandard and Fast drying profiles:\u003c\/strong\u003e\n    Gives users two heating approaches without adding unnecessary method complexity for routine applications.\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eAutomatic shutoff:\u003c\/strong\u003e\n    Three automatic shutoff settings can end the test once the rate of weight loss reaches the selected stability condition.\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eTimed and manual operation:\u003c\/strong\u003e\n    Tests can also run for a defined time from 1 to 480 minutes or be stopped manually.\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eTwo-method library:\u003c\/strong\u003e\n    Store two commonly used drying methods so routine samples do not need to be programmed from scratch every time.\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eSimple 4-inch LCD interface:\u003c\/strong\u003e\n    A second display line, navigation knob, progress information, and on-screen instructions make the MB32 practical for recurring operator use.\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eRS232 and USB device connectivity:\u003c\/strong\u003e\n    Allows compatible connection to printers or computer-based documentation workflows.\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eDesigned for routine lab and production use:\u003c\/strong\u003e\n    PBT housing, die-cast aluminium base, metal pan support, and metal pan handler provide a robust working platform.\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eCanadian electrical compliance:\u003c\/strong\u003e\n    OHAUS lists CAN\/CSA C22.2 61010-1 and CAN\/CSA C22.2 61010-2-010 compliance and a CSA compliance mark for the MB32.\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow Does the MB32 Measure Moisture?\u003c\/h2\u003e\n\n\u003cp\u003e\n  The MB32 uses a \u003cstrong\u003ethermogravimetric moisture-analysis method\u003c\/strong\u003e. First, the instrument records the initial weight of the sample. The integrated carbon-fibre heater then heats the sample while the precision balance continuously measures the reduction in mass as volatile moisture is removed.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  The instrument uses the change between the initial and final sample weights to calculate the moisture result. Depending on the selected result mode, the MB32 can report \u003cstrong\u003emoisture content, dry content \/ solids, moisture regain, or sample weight\u003c\/strong\u003e.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  This allows many routine moisture checks to be completed considerably faster than conventional drying-oven workflows while combining the heating and weighing steps in one instrument.\n\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#fff8e5;\"\u003e\n  \u003ch3 style=\"margin-top:0; font-size:18px; line-height:1.35;\"\u003eImportant Method Development Note\u003c\/h3\u003e\n\n  \u003cp style=\"margin-bottom:0;\"\u003e\n    A moisture analyzer does not automatically reproduce the result of every reference oven method. Temperature, sample size, sample preparation, sample distribution, drying profile, and shutoff criterion should be developed and validated against your laboratory's reference method or acceptance criteria where required.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n  \u003ctbody\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eHow the MB32 Helps\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eFood \u0026amp; Beverage QA\/QC\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eProvides rapid moisture or solids testing for suitable ingredients, intermediate products, and finished-product samples after a method has been established.\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eAgriculture \u0026amp; Feed\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eUseful for routine moisture screening of suitable grains, feed ingredients, powders, and agricultural materials when the appropriate preparation and drying method has been validated.\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eChemical \u0026amp; Industrial QA\/QC\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSupports incoming-material, formulation, process, and finished-product moisture checks for compatible samples.\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eResearch \u0026amp; Product Development\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eProvides adjustable temperature and drying parameters for developing repeatable moisture-analysis procedures.\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eProduction Quality Control\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eCan provide faster feedback than conventional oven drying for compatible in-process or finished-product moisture checks.\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eEnvironmental \u0026amp; Materials Labs\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eUseful for compatible samples where moisture, dry-solids, or mass-loss determination is part of a laboratory-developed procedure.\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eOHAUS MB32 Specifications\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n  \u003ctbody\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eOHAUS MB32\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eOHAUS Item Number – 110 V\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e30971928\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eMaximum Capacity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e90 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eWeight Readability\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e0.001 g \/ 1 mg\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eMoisture Readability\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e0.01%\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eRepeatability\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e0.15% with 3 g sample; 0.02% with 10 g sample\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eRecommended Moisture Content\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e0.5% to 100%\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eMoisture Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e0.01% to 100%; 0.01% to 1000% in regain mode\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eMinimum Start Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e0.5 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eHeating Element\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eCarbon-fibre infrared heater\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e40°C to 180°C in 1°C increments\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eDrying Profiles\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eStandard, Fast\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eMethod Library\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e2 methods\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eStored Results\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e1 result\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eSwitch-Off Criteria\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e3 automatic settings, timed 1–480 min., manual\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e4 in. LCD with second-line display\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eDisplayed Results\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMC%, DC%, RG%, time, temperature, weight and method number\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eRS232 and USB device\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eWeight Adjustment\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eExternal 50 g mass\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eTemperature Adjustment\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e100°C and 160°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003ePan Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e90 mm \/ 3.5 in.\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e210 x 138 x 352 mm \/ 8.3 x 5.4 x 13.9 in.\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e4.3 kg \/ 9.5 lb\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e10°C to 40°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003ePower – Canadian \/ North American Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e120 VAC, 50\/60 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eStandard vs Fast Drying\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eStandard Drying\u003c\/h3\u003e\n\u003cp\u003e\n  Standard mode is the general-purpose heating profile and is a good starting point for many routine samples where controlled, consistent heating is preferred.\n\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eFast Drying\u003c\/h3\u003e\n\u003cp\u003e\n  Fast mode is intended to bring suitable samples toward the target drying conditions more aggressively to reduce analysis time. It should be used only where the sample can tolerate the heating behaviour without burning, decomposing, forming a surface crust, or producing a biased result.\n\u003c\/p\u003e\n\n\u003ch2\u003eSample Preparation Matters\u003c\/h2\u003e\n\n\u003cp\u003e\n  Moisture-analysis repeatability depends heavily on sample preparation. Whenever possible, use a representative sample and distribute it in a \u003cstrong\u003ethin, even layer across the sample pan\u003c\/strong\u003e. Large piles or uneven distribution can slow moisture release and leave portions of the sample incompletely dried.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  OHAUS specifically notes that glass-fibre pads can be useful with \u003cstrong\u003eliquids, pastes, fat-containing materials, melting samples, skin-forming products, and some temperature-sensitive samples\u003c\/strong\u003e. The pad increases the effective sample area and can improve drying behaviour.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  Samples containing high levels of sugar may require moderate temperatures and thin sample layers to reduce surface caramelization.\n\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n  \u003ch3 style=\"margin-top:0; font-size:18px; line-height:1.35;\"\u003eBetter Moisture Results Start with Better Sample Preparation\u003c\/h3\u003e\n\n  \u003cp style=\"margin-bottom:0;\"\u003e\n    If you are replacing an oven method, start by matching the sample preparation, sample mass, drying temperature, and endpoint criteria as closely as practical. Then compare multiple samples against your established reference method before adopting the MB32 result for routine release or process-control decisions.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eWhat Is Included with the OHAUS MB32?\u003c\/h2\u003e\n\n\u003cul\u003e\n  \u003cli\u003eOHAUS MB32 Moisture Analyzer\u003c\/li\u003e\n  \u003cli\u003e1 box of aluminium sample pans\u003c\/li\u003e\n  \u003cli\u003ePan holder\u003c\/li\u003e\n  \u003cli\u003e5 glass-fibre pads\u003c\/li\u003e\n  \u003cli\u003eTray pan\u003c\/li\u003e\n  \u003cli\u003ePower cable\u003c\/li\u003e\n  \u003cli\u003ePan handle\u003c\/li\u003e\n  \u003cli\u003eQuick-start guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eMB32 vs MB62 vs MB92\u003c\/h2\u003e\n\n\u003cp\u003e\n  All three next-generation OHAUS MB models provide 90 g capacity, 0.001 g weight readability and carbon-fibre heating, but they are designed for different levels of method complexity and data management.\n\u003c\/p\u003e\n\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px; min-width:800px;\"\u003e\n  \u003ctbody\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eMB32\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eMB62\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eMB92\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\u003cstrong\u003eBest Fit\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eRoutine moisture testing\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMultiple products and more flexible methods\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eHigher-performance testing and stronger data management\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\u003cstrong\u003eCapacity \/ Readability\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e90 g \/ 0.001 g\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e90 g \/ 0.001 g\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e90 g \/ 0.001 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e40–180°C\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e40–200°C\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e40–200°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\u003cstrong\u003eDrying Profiles\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e2 – Standard, Fast\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e4 – Standard, Fast, Ramp, Step\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e4 – Standard, Fast, Ramp, Step\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\u003cstrong\u003eStored Methods\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e2\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e20\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e20\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\u003cstrong\u003eStored Results\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e1\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e100\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e200\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e4 in. LCD + knob\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e5 in. LCD + knob\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e4.3 in. colour touchscreen\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003cp\u003e\n  \u003cstrong\u003eChoose the MB32\u003c\/strong\u003e when you have a small number of routine methods and do not need extensive onboard result storage.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  \u003cstrong\u003eConsider the \u003ca href=\"\/products\/ohaus-mb62-90g-x-0-001g-moisture-analyzer\"\u003eOHAUS MB62\u003c\/a\u003e\u003c\/strong\u003e when you need more drying profiles, up to 20 stored methods, sample ID management, and substantially greater result storage.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  \u003cstrong\u003eConsider the \u003ca href=\"\/products\/ohaus-mb92-90g-x-0-001g-moisture-analyzer\"\u003eOHAUS MB92\u003c\/a\u003e\u003c\/strong\u003e when you need a touchscreen interface, more advanced data-management features, additional connectivity, and a higher-performance moisture-analysis platform.\n\u003c\/p\u003e\n\n\u003ch2\u003eOHAUS MB32 Accessories \u0026amp; Consumables\u003c\/h2\u003e\n\n\u003cp\u003e\n  Routine moisture analysis requires sample pans and may benefit from glass-fibre pads, reusable pans, calibration equipment, or printing accessories depending on the application.\n\u003c\/p\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n  \u003ctbody\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eOHAUS Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eAccessory\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\u003cstrong\u003e30954234\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003ePan Handler – MB32 \/ MB62 \/ MB92\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\u003cstrong\u003e30954235\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eIn-Use Cover – MB32 \/ MB62\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\u003cstrong\u003e11113857\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eTemperature Calibration Kit\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\u003cstrong\u003e80850086 \/ 30585411\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eAluminium sample pans – quantity depends on current OHAUS package \/ part number\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\u003cstrong\u003e80850087\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eGlass Fibre Pads\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\u003cstrong\u003e80252477\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSample Cage\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\u003cstrong\u003e80252478\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eReusable Pan Set – 7 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\u003cstrong\u003e80252479\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eReusable Pan Set – 14 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\u003cstrong\u003e30064203\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSF40A Impact Printer – North American configuration\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\n  \u003ca href=\"\/products\/ohaus-mb-series-accessories\"\u003e\u003cstrong\u003eShop OHAUS MB Series Moisture Analyzer Accessories\u003c\/strong\u003e\u003c\/a\u003e\n\u003c\/p\u003e\n\n\u003ch2\u003eCompliance\u003c\/h2\u003e\n\n\u003cp\u003e\n  OHAUS lists the MB32 to applicable IEC\/EN and North American laboratory-equipment safety standards, including \u003cstrong\u003eCAN\/CSA C22.2 61010-1\u003c\/strong\u003e and \u003cstrong\u003eCAN\/CSA C22.2 61010-2-010\u003c\/strong\u003e. The current OHAUS datasheet lists \u003cstrong\u003eCSA, CE, RCM, and WEEE\u003c\/strong\u003e compliance marks.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  The management system governing manufacture of the product is listed by OHAUS as ISO 9001:2015 certified. This is a manufacturing quality-system certification and should not be interpreted as an ISO accreditation of individual moisture results.\n\u003c\/p\u003e\n\n\u003ch2\u003eCommon Questions About the OHAUS MB32\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhat does the OHAUS MB32 measure?\u003c\/h3\u003e\n\u003cp\u003e\n  The MB32 uses thermogravimetric analysis to determine moisture content by weighing a sample before and during controlled heating. It can display moisture percentage, solids percentage, regain percentage, weight, time, and temperature.\n\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhat is the capacity and readability of the MB32?\u003c\/h3\u003e\n\u003cp\u003e\n  The MB32 has a maximum weighing capacity of 90 g, weight readability of 0.001 g, and moisture-content readability of 0.01%.\n\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhat temperature range does the MB32 provide?\u003c\/h3\u003e\n\u003cp\u003e\n  The heating temperature can be set from 40°C to 180°C in 1°C increments.\n\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHow many methods can the MB32 store?\u003c\/h3\u003e\n\u003cp\u003e\n  The MB32 stores up to two drying methods. If you routinely test many different products, the MB62 or MB92 may be a better choice because each stores up to 20 methods.\n\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eCan the MB32 replace a drying oven?\u003c\/h3\u003e\n\u003cp\u003e\n  A moisture analyzer can provide much faster moisture results for suitable samples, but the method should be developed and compared against your laboratory's reference procedure before it is used as a replacement for an established oven method.\n\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eCan the MB32 test food samples?\u003c\/h3\u003e\n\u003cp\u003e\n  Yes. Moisture analyzers are widely used in food and beverage QA\/QC. The correct sample size, preparation, temperature, drying profile, and endpoint should be established for the specific food product being tested.\n\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eCan the MB32 measure solids instead of moisture?\u003c\/h3\u003e\n\u003cp\u003e\n  Yes. In addition to moisture content, the MB32 can report dry-content \/ solids percentage and moisture regain.\n\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eDoes the MB32 connect to a computer or printer?\u003c\/h3\u003e\n\u003cp\u003e\n  Yes. The MB32 provides RS232 and USB device communication for compatible printing and data-transfer workflows.\n\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhat calibration or adjustment does the MB32 support?\u003c\/h3\u003e\n\u003cp\u003e\n  The MB32 supports external weight adjustment using a 50 g mass and temperature adjustment at 100°C and 160°C. OHAUS also offers the 11113857 MB Series Temperature Calibration Kit.\n\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhere can I buy the OHAUS MB32 in Canada?\u003c\/h3\u003e\n\u003cp\u003e\n  Cambridge Environmental Products supplies the OHAUS MB32 Moisture Analyzer in Canada with CAD pricing, accessories, consumables, and support for Canadian laboratories, food and beverage processors, agricultural users, industrial QA\/QC, research, and production facilities.\n\u003c\/p\u003e\n\n\u003ch2\u003eAvailable Literature\u003c\/h2\u003e\n\n\u003cp\u003e\n  \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/US__Datasheet_MB32_EN__80776942.pdf?v=1729617925\" target=\"_blank\" rel=\"noopener\"\u003e\n    OHAUS MB32 Data Sheet\n  \u003c\/a\u003e\u003cbr\u003e\n\n  \u003ca href=\"https:\/\/indd.adobe.com\/view\/dfa23918-f8e5-485b-9eac-036aab66f7ae\" target=\"_blank\" rel=\"noopener\"\u003e\n    OHAUS MB32 \/ MB62 \/ MB92 Interactive Guide\n  \u003c\/a\u003e\n\u003c\/p\u003e\n\n\u003ch2\u003eCanadian Purchasing Support\u003c\/h2\u003e\n\n\u003cp\u003e\n  Cambridge Environmental Products supplies OHAUS moisture analyzers, sample pans, glass-fibre pads, calibration accessories, and related laboratory equipment across Canada.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  If you are replacing an oven method or selecting a moisture analyzer for a new application, tell us the \u003cstrong\u003esample type, expected moisture range, typical sample weight, current drying temperature and method, and number of different products you test\u003c\/strong\u003e. We can help determine whether the MB32, MB62, MB92, or another moisture analyzer is the better fit.\n\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:22px; margin-top:32px; border-radius:8px; background:#f8f8f8;\"\u003e\n  \u003ch2 style=\"margin-top:0;\"\u003eNeed Help Choosing a Moisture Analyzer?\u003c\/h2\u003e\n\n  \u003cp\u003e\n    The MB32 is an excellent fit when you need repeatable routine moisture testing without paying for extensive method storage and advanced data-management features you may never use.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    \u003cstrong\u003eSend Cambridge your sample and current moisture-testing procedure and we can help compare the MB32 with the MB62, MB92, A\u0026amp;D, Adam, or other moisture-analyzer options.\u003c\/strong\u003e\n  \u003c\/p\u003e\n\n  \u003cp style=\"margin-bottom:0;\"\u003e\n    \u003ca href=\"\/pages\/contact\" style=\"display:inline-block; padding:12px 18px; background:#1f4e79; color:#ffffff; text-decoration:none; border-radius:5px; font-weight:bold;\"\u003e\n      Contact Cambridge for Moisture Analyzer Support\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\u003c\/div\u003e","brand":"Ohaus","offers":[{"title":"Default Title","offer_id":46059039260931,"sku":"MB32","price":4349.36,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/MB32.png?v=1729614797","url":"https:\/\/cambridgeenviro.com\/products\/products-ohaus-mb32-90g-x-0-001g-moisture-analyzer","provider":"Cambridge Environmental Products, Inc.","version":"1.0","type":"link"}