{"product_id":"ohaus-stcon7-low-conductivity-probe-canada","title":"Ohaus STCON7 Conductivity Probe","description":"\u003ch2\u003eOHAUS STCON7 Low Conductivity Probe\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eOHAUS STCON7 Conductivity Probe\u003c\/strong\u003e is a low-conductivity electrode designed for measuring samples such as \u003cstrong\u003epure water, distilled water, deionized water, and other low-conductivity laboratory solutions\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eUnlike general-purpose conductivity probes intended for higher conductivity samples, the STCON7 is built for the low µS\/cm range, with a measurement range of \u003cstrong\u003e0.02 to 200 µS\/cm\u003c\/strong\u003e. It uses a \u003cstrong\u003e2-pole potentiometric measuring method\u003c\/strong\u003e and includes automatic temperature compensation through its built-in temperature sensor.\u003c\/p\u003e\n\u003cdiv style=\"border: 1px solid #d9d9d9; padding: 18px; margin: 24px 0; border-radius: 8px; background: #f8f8f8;\"\u003e\n\u003ch3 style=\"margin-top: 0; font-size: 18px; line-height: 1.35;\"\u003eDesigned for Low Conductivity Water Testing\u003c\/h3\u003e\n\u003cul style=\"margin-bottom: 0;\"\u003e\n\u003cli\u003ePure water conductivity testing\u003c\/li\u003e\n\u003cli\u003eDistilled water and deionized water checks\u003c\/li\u003e\n\u003cli\u003eLaboratory water quality verification\u003c\/li\u003e\n\u003cli\u003eLow-conductivity process water testing\u003c\/li\u003e\n\u003cli\u003eResearch, quality control, environmental, education, and general laboratory use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eWhy Choose the OHAUS STCON7?\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow conductivity measurement range:\u003c\/strong\u003e Designed for 0.02 to 200 µS\/cm conductivity measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePure water application fit:\u003c\/strong\u003e Well suited for pure water, distilled water, and other low-conductivity sample types.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-pole potentiometric design:\u003c\/strong\u003e Built for conductivity measurement in the low µS\/cm range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic temperature compensation:\u003c\/strong\u003e Built-in temperature sensor supports temperature-compensated conductivity measurements when used with compatible OHAUS meters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMini-DIN connection:\u003c\/strong\u003e Designed for connection to compatible OHAUS Starter conductivity meters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e316L stainless steel measuring cell:\u003c\/strong\u003e Measuring cell chamber uses 316L stainless steel construction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact probe design:\u003c\/strong\u003e 95 mm shaft length and 12 mm shaft diameter for routine laboratory use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCanadian purchasing support:\u003c\/strong\u003e Supplied by Cambridge Environmental Products with CAD pricing and support for Canadian laboratories and facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOHAUS STCON7 Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 12px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eLow conductivity probe \/ conductivity electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eOHAUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eSTCON7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eOHAUS Item Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e30080693\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eMeasurement Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e2-pole potentiometric conductivity measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e0.02 to 200 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e0.02 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e0 to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eTemperature Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eAutomatic temperature compensation with built-in temperature sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eMini-DIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e1.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eShaft Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e95 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eShaft Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eShaft Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eABS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eCell Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e316L stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eCommon Applications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003ePure water, distilled water, deionized water, low-conductivity water, laboratory water quality checks, research, QC, and environmental testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eCompatible Meter Notes\u003c\/h2\u003e\n\u003cp\u003eThe STCON7 uses a Mini-DIN connection and is intended for use with compatible OHAUS Starter conductivity meters. OHAUS documentation identifies the STCON7 for use with the \u003cstrong\u003eStarter 300C\u003c\/strong\u003e and \u003cstrong\u003eStarter 3100C\u003c\/strong\u003e meters.\u003c\/p\u003e\n\u003cp\u003eBefore ordering, confirm that your meter accepts the STCON7 Mini-DIN conductivity electrode connection and supports the required low-conductivity measurement range for your application.\u003c\/p\u003e\n\u003ch2\u003eCare and Use Notes\u003c\/h2\u003e\n\u003cp\u003eFor best results, rinse the probe with distilled water between measurements to reduce carry-over from one solution to another. When measuring, make sure the solution is above the cell chamber and that the cell chamber is free of bubbles.\u003c\/p\u003e\n\u003cp\u003eAllow sufficient time for the probe to stabilize when measuring samples at different temperatures. If solids build up inside the cell chamber, carefully clean the chamber using a cotton swab soaked in detergent solution, then rinse the probe with distilled water.\u003c\/p\u003e\n\u003cp\u003eDo not expose the probe shaft to organic solvents during cleaning or measurement. Do not use the probe outside the recommended temperature range. Follow the OHAUS meter manual and your internal laboratory procedure for calibration and measurement.\u003c\/p\u003e\n\u003cdiv style=\"border: 1px solid #d9d9d9; padding: 18px; margin: 24px 0; border-radius: 8px; background: #fff8e5;\"\u003e\n\u003ch3 style=\"margin-top: 0; font-size: 18px; line-height: 1.35;\"\u003eLow Conductivity Probe Selection Note\u003c\/h3\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003eThe STCON7 is intended for low-conductivity measurements from 0.02 to 200 µS\/cm. If your samples are higher conductivity solutions, salt solutions, wastewater, process water, or general-purpose conductivity samples, another OHAUS conductivity probe may be a better fit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eCanadian Purchasing Support\u003c\/h2\u003e\n\u003cp\u003eCambridge Environmental Products supplies the OHAUS STCON7 Conductivity Probe in Canada with CAD pricing, Canadian purchasing support, and access to related OHAUS conductivity meters, electrodes, buffers, conductivity standards, and laboratory water testing supplies.\u003c\/p\u003e\n\u003ch2\u003eCommon Questions About the OHAUS STCON7 Conductivity Probe\u003c\/h2\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eWhat is the OHAUS STCON7 used for?\u003c\/h3\u003e\n\u003cp\u003eThe OHAUS STCON7 is used for low-conductivity measurement in samples such as pure water, distilled water, deionized water, and other low-conductivity laboratory solutions.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eWhat is the measurement range of the STCON7?\u003c\/h3\u003e\n\u003cp\u003eThe STCON7 measurement range is 0.02 to 200 µS\/cm.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eIs the STCON7 suitable for pure water testing?\u003c\/h3\u003e\n\u003cp\u003eYes. The STCON7 is specifically designed for low-conductivity measurements, including pure water and distilled water testing.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eDoes the STCON7 include temperature compensation?\u003c\/h3\u003e\n\u003cp\u003eYes. The STCON7 includes a built-in temperature sensor for automatic temperature compensation when used with a compatible OHAUS conductivity meter.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eWhat meters are compatible with the STCON7?\u003c\/h3\u003e\n\u003cp\u003eOHAUS documentation identifies the STCON7 for use with the Starter 300C and Starter 3100C conductivity meters. Confirm meter compatibility before ordering if you are using another OHAUS model.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eCan I use the STCON7 for general high-conductivity samples?\u003c\/h3\u003e\n\u003cp\u003eThe STCON7 is intended for low-conductivity measurements from 0.02 to 200 µS\/cm. For higher-conductivity samples, another OHAUS conductivity probe may be more appropriate.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eHow should I clean the STCON7?\u003c\/h3\u003e\n\u003cp\u003eRinse the probe with distilled water between and after measurements. If solids build up in the measuring cell chamber, clean carefully with a cotton swab soaked in detergent solution, then rinse with distilled water. Do not expose the shaft to organic solvents.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eWhere can I buy the OHAUS STCON7 in Canada?\u003c\/h3\u003e\n\u003cp\u003eCambridge Environmental Products supplies the OHAUS STCON7 Conductivity Probe in Canada with CAD pricing and Canadian purchasing support for laboratories, water testing facilities, schools, research teams, and QC labs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration-line: underline;\"\u003e\u003cbr\u003eAvailable Literature:\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e \u003ca rel=\"noopener\" href=\"https:\/\/dmx.ohaus.com\/WorkArea\/showcontent.aspx?id=4294967519\" target=\"_blank\"\u003eOHAUS Starter Series Electrodes Data Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca rel=\"noopener\" href=\"https:\/\/dmx.ohaus.com\/WorkArea\/showcontent.aspx?id=34016\" target=\"_blank\"\u003eOHAUS STCON7 Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv style=\"border: 1px solid #d9d9d9; padding: 22px; margin-top: 32px; border-radius: 8px; background: #f8f8f8;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eNeed Help Choosing an OHAUS Conductivity Probe?\u003c\/h2\u003e\n\u003cp\u003eNot sure if the STCON7 is the right conductivity probe for your water testing workflow? Cambridge Environmental Products can help Canadian buyers compare OHAUS conductivity probes, compatible meters, conductivity standards, and related water analysis supplies.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContact us before ordering if you need help confirming meter compatibility, measurement range, or the correct probe for your sample type.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003ca style=\"display: inline-block; padding: 12px 18px; background: #1f4e79; color: #ffffff; text-decoration: none; border-radius: 5px; font-weight: bold;\" href=\"\/pages\/contact\"\u003e Contact Cambridge for OHAUS Conductivity Support \u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Ohaus","offers":[{"title":"Default Title","offer_id":238462140442,"sku":"STCON7","price":957.02,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale)","offer_id":238462205978,"sku":"STCON7","price":778.06,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/STCON7_DMX-ID_4294967702_WebShop.jpg?v=1631199378","url":"https:\/\/cambridgeenviro.com\/products\/ohaus-stcon7-low-conductivity-probe-canada","provider":"Cambridge Environmental Products, Inc.","version":"1.0","type":"link"}