{"product_id":"f-10300-process-centrifuge","title":"F-10300 Process Centrifuge","description":"\u003cp style=\"text-align: center;\" data-end=\"207\" data-start=\"185\"\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eF-10300 Process Centrifuge\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-end=\"529\" data-start=\"209\"\u003e\u003cstrong data-end=\"245\" data-start=\"209\"\u003eRaven F-10300 Process Centrifuge\u003c\/strong\u003e is a proven, industrial-grade solution for quickly determining percent solids in liquid samples. Trusted by process engineers since 1983, the F-10300 delivers reliable, repeatable results in as little as\u003cstrong\u003e \u003c\/strong\u003e15 minutes, helping operators make informed, proactive process adjustments.\u003c\/p\u003e\n\u003cp data-end=\"908\" data-start=\"531\"\u003eDesigned specifically for applications such as wastewater treatment, industrial pre-treatment, food and beverage processing, mining, fluid reclamation, and machining fluids, the F-10300 features a 3000 RPM horizontal swing-out rotor that creates a clean, straight-line interface between compacted solids and supernatant; essential for accurate solids volume measurement.\u003c\/p\u003e\n\u003cp data-end=\"1328\" data-start=\"910\"\u003eOperation is simple: load the samples, set the timer, and start. The digital countdown timer with audible end-of-cycle alert ensures consistent spin times, while dedicated controls (including a one-touch 15-minute wastewater spin) streamline routine testing. Built with a stainless steel structure and precision aluminum components, the F-10300 operates smoothly and quietly in demanding industrial environments.\u003c\/p\u003e\n\u003cp data-end=\"1525\" data-start=\"1330\"\u003eThe centrifuge comes with six reusable polycarbonate centrifuge tubes with high-visibility graduations from 0.20% to 100%, allowing direct solids percentage readings without calculations.\u003c\/p\u003e\n\u003cp data-end=\"1525\" data-start=\"1330\"\u003e\u003cbr\u003e\u003cstrong data-start=\"256\" data-end=\"307\"\u003eRaven B-10101-19 Polycarbonate Centrifuge Tubes\u003c\/strong\u003e are durable, reusable tubes designed for precise solids measurement in industrial samples. Featuring a conical bottom and a clearly marked graduated scale from 0.2% to 100%, these tubes make it easy to quantify even very small amounts of compacted solids.\u003c\/p\u003e\n\u003cp data-start=\"571\" data-end=\"862\"\u003eSpecifically designed to fit directly in the trunnion rings of Raven’s F-10300 Process Centrifuge, the tubes hang securely in place during high-speed spins. Constructed from high-strength polycarbonate, they are built to withstand repeated use in demanding industrial environments.\u003c\/p\u003e\n\u003cblockquote data-start=\"864\" data-end=\"957\"\u003e\n\u003cp data-start=\"866\" data-end=\"957\"\u003e\u003cstrong data-start=\"866\" data-end=\"880\"\u003eImportant:\u003c\/strong\u003e These tubes \u003cstrong data-start=\"893\" data-end=\"954\"\u003ecannot be used with flammables, solvents, or cooking oils\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cp data-start=\"959\" data-end=\"1056\"\u003eSold in packs of \u003cstrong data-start=\"976\" data-end=\"988\"\u003e12 tubes\u003c\/strong\u003e, making them ideal for routine testing or keeping spares on hand.\u003c\/p\u003e\n\u003chr data-end=\"1651\" data-start=\"1648\"\u003e\n\u003cp data-end=\"1679\" data-start=\"1653\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"2785\" data-start=\"1681\"\u003e\n\u003cli data-end=\"1769\" data-start=\"1681\"\u003e\n\u003cp data-end=\"1769\" data-start=\"1683\"\u003e\u003cstrong data-end=\"1707\" data-start=\"1683\"\u003eFast solids analysis\u003c\/strong\u003e – Determine percent solids by volume in just \u003cstrong data-end=\"1767\" data-start=\"1753\"\u003e15 minutes\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1883\" data-start=\"1770\"\u003e\n\u003cp data-end=\"1883\" data-start=\"1772\"\u003e\u003cstrong data-end=\"1811\" data-start=\"1772\"\u003e3000 RPM horizontal swing-out rotor\u003c\/strong\u003e – Ensures a straight solids-to-liquid interface for accurate readings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1967\" data-start=\"1884\"\u003e\n\u003cp data-end=\"1967\" data-start=\"1886\"\u003e\u003cstrong data-end=\"1907\" data-start=\"1886\"\u003eSix-tube capacity\u003c\/strong\u003e – Efficient batch sampling for routine process monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2099\" data-start=\"1968\"\u003e\n\u003cp data-end=\"2099\" data-start=\"1970\"\u003e\u003cstrong data-end=\"1999\" data-start=\"1970\"\u003eIndustrial-focused design\u003c\/strong\u003e – Ideal for wastewater, industrial pre-treatment, food \u0026amp; beverage, mining, and fluids reclamation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2197\" data-start=\"2100\"\u003e\n\u003cp data-end=\"2197\" data-start=\"2102\"\u003e\u003cstrong data-end=\"2127\" data-start=\"2102\"\u003eDigital control panel\u003c\/strong\u003e – LCD display with countdown timer and audible cycle-complete alert\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2311\" data-start=\"2198\"\u003e\n\u003cp data-end=\"2311\" data-start=\"2200\"\u003e\u003cstrong data-end=\"2233\" data-start=\"2200\"\u003eWastewater-optimized controls\u003c\/strong\u003e – Dedicated 15-minute speed key plus one-minute increment\/decrement buttons\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2435\" data-start=\"2312\"\u003e\n\u003cp data-end=\"2435\" data-start=\"2314\"\u003e\u003cstrong data-end=\"2351\" data-start=\"2314\"\u003eReusable graduated tubes included\u003c\/strong\u003e – Six polycarbonate tubes with conical bottoms, clearly marked from 0.20% to 100%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2520\" data-start=\"2436\"\u003e\n\u003cp data-end=\"2520\" data-start=\"2438\"\u003e\u003cstrong data-end=\"2465\" data-start=\"2438\"\u003eSmooth, quiet operation\u003c\/strong\u003e – Precision-balanced rotor and enclosed motor design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2600\" data-start=\"2521\"\u003e\n\u003cp data-end=\"2600\" data-start=\"2523\"\u003e\u003cstrong data-end=\"2547\" data-start=\"2523\"\u003eDurable construction\u003c\/strong\u003e – Stainless steel housing with aluminum components\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2683\" data-start=\"2601\"\u003e\n\u003cp data-end=\"2683\" data-start=\"2603\"\u003e\u003cstrong data-end=\"2617\" data-start=\"2603\"\u003eTEFC motor\u003c\/strong\u003e – Totally enclosed, fan-cooled motor for industrial reliability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2763\" data-start=\"2684\"\u003e\n\u003cp data-end=\"2763\" data-start=\"2686\"\u003e\u003cstrong data-end=\"2707\" data-start=\"2686\"\u003eCompact footprint\u003c\/strong\u003e – Bench-friendly size without sacrificing performance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2785\" data-start=\"2764\"\u003e\n\u003cp data-end=\"2785\" data-start=\"2766\"\u003e\u003cstrong data-end=\"2785\" data-start=\"2766\"\u003e1-year warranty\u003c\/strong\u003e\u003cstrong data-end=\"2785\" data-start=\"2766\"\u003e\u003c\/strong\u003e\u003cstrong data-end=\"2785\" data-start=\"2766\"\u003e\u003c\/strong\u003e\u003cstrong data-end=\"2785\" data-start=\"2766\"\u003e\u003c\/strong\u003e\u003cstrong data-end=\"2785\" data-start=\"2766\"\u003e\u003c\/strong\u003e\u003cstrong data-end=\"2785\" data-start=\"2766\"\u003e\u003c\/strong\u003e\u003cstrong data-end=\"2785\" data-start=\"2766\"\u003e\u003c\/strong\u003e\u003cstrong data-end=\"2785\" data-start=\"2766\"\u003e\u003c\/strong\u003e\u003cstrong data-end=\"2785\" data-start=\"2766\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2785\" data-start=\"2766\"\u003e \u003c\/p\u003e\n\u003cp data-end=\"2785\" data-start=\"2766\"\u003e\u003cstrong data-end=\"2785\" data-start=\"2766\"\u003e\u003c\/strong\u003e\u003cstrong\u003eDocumentation\u003c\/strong\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/Focus_Centrifuge_F-10300.pdf?v=1769454318\"\u003eBrochure\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/Waste_Water_Application_F-10300.pdf?v=1769454326\"\u003eWaste Water Application\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/TBbLi_QAefw?si=Z7gXVgz0FshCuKg7\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp data-end=\"205\" data-start=\"164\"\u003eFAQ — Raven F-10300 Process Centrifuge\u003c\/p\u003e\n\u003cp data-end=\"254\" data-start=\"207\"\u003e1) What is the F-10300 designed to measure?\u003c\/p\u003e\n\u003cp data-end=\"540\" data-start=\"255\"\u003eThe F-10300 is designed for \u003cstrong data-end=\"319\" data-start=\"283\"\u003erapid percent solids (by volume)\u003c\/strong\u003e testing in liquid samples using the graduated Raven polycarbonate tubes, typically as a \u003cstrong data-end=\"427\" data-start=\"408\"\u003eprocess-control\u003c\/strong\u003e tool for wastewater, industrial pretreatment, and other industrial fluids. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"589\" data-start=\"542\"\u003e2) Is this the same as MLSS (mg\/L) testing?\u003c\/p\u003e\n\u003cp data-end=\"949\" data-start=\"590\"\u003eNot exactly. The centrifuge tube provides a \u003cstrong data-end=\"669\" data-start=\"634\"\u003ecompacted solids volume reading\u003c\/strong\u003e (a “percent solids by volume” style result). MLSS is typically reported as \u003cstrong data-end=\"753\" data-start=\"745\"\u003emg\/L\u003c\/strong\u003e using a gravimetric lab method. Operators often use the centrifuge for fast trending, then \u003cstrong data-end=\"858\" data-start=\"845\"\u003ecorrelate\u003c\/strong\u003e it to lab MLSS values if they need mg\/L equivalents. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"1010\" data-start=\"951\"\u003e3) Can I convert the centrifuge reading to MLSS (mg\/L)?\u003c\/p\u003e\n\u003cp data-end=\"1319\" data-start=\"1011\"\u003eYes—\u003cstrong data-end=\"1059\" data-start=\"1015\"\u003eif you build a site-specific correlation\u003c\/strong\u003e. A common approach is to run the centrifuge test and send the same samples for lab MLSS (or run the Standard Methods gravimetric test), then graph results to create a conversion curve for your plant and sludge conditions. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"1349\" data-start=\"1321\"\u003e4) How fast is the test?\u003c\/p\u003e\n\u003cp data-end=\"1624\" data-start=\"1350\"\u003eThe unit is built around fast decision-making: typical wastewater spins are \u003cstrong data-end=\"1454\" data-start=\"1426\"\u003eas little as ~15 minutes\u003c\/strong\u003e, and the control panel includes a \u003cstrong data-end=\"1527\" data-start=\"1489\"\u003ededicated 15-minute wastewater key\u003c\/strong\u003e plus 1-minute increment\/decrement buttons for consistency. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"1668\" data-start=\"1626\"\u003e5) How many samples can I run at once?\u003c\/p\u003e\n\u003cp data-end=\"1805\" data-start=\"1669\"\u003eThe rotor is a \u003cstrong data-end=\"1728\" data-start=\"1684\"\u003esix-position horizontal swing-out design\u003c\/strong\u003e, allowing up to \u003cstrong data-end=\"1766\" data-start=\"1745\"\u003esix tubes per run\u003c\/strong\u003e. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"1861\" data-start=\"1807\"\u003e6) Why does the horizontal swing-out rotor matter?\u003c\/p\u003e\n\u003cp data-end=\"2090\" data-start=\"1862\"\u003eA horizontal swing-out rotor produces a \u003cstrong data-end=\"1936\" data-start=\"1902\"\u003eclean, straight-line interface\u003c\/strong\u003e between compacted solids and the supernatant—this is the whole point for readable percent-solids-by-volume results. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"2153\" data-start=\"2092\"\u003e7) What tubes does it use, and what is the reading range?\u003c\/p\u003e\n\u003cp data-end=\"2392\" data-start=\"2154\"\u003eIt uses Raven’s reusable \u003cstrong data-end=\"2210\" data-start=\"2179\"\u003epolycarbonate conical tubes\u003c\/strong\u003e with high-visibility graduations from \u003cstrong data-end=\"2266\" data-start=\"2249\"\u003e0.20% to 100%\u003c\/strong\u003e, enabling direct readings without calculations. The tube volume is listed as \u003cstrong data-end=\"2353\" data-start=\"2344\"\u003e11 mL\u003c\/strong\u003e. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"2437\" data-start=\"2394\"\u003e8) What’s included with the centrifuge?\u003c\/p\u003e\n\u003cp data-end=\"2590\" data-start=\"2438\"\u003eThe centrifuge is supplied with \u003cstrong data-end=\"2523\" data-start=\"2470\"\u003esix reusable Raven polycarbonate centrifuge tubes\u003c\/strong\u003e for percent-solids readings. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"2637\" data-start=\"2592\"\u003e9) Are extra\/replacement tubes available?\u003c\/p\u003e\n\u003cp data-end=\"2752\" data-start=\"2638\"\u003eYes—replacement tubes are available as \u003cstrong data-end=\"2697\" data-start=\"2677\"\u003eRaven B-10101-19\u003c\/strong\u003e (sold in packs). \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"2820\" data-start=\"2754\"\u003e10) Are there sample limitations (chemicals I should not use)?\u003c\/p\u003e\n\u003cp data-end=\"3039\" data-start=\"2821\"\u003eYes. The Raven polycarbonate tubes are \u003cstrong data-end=\"2909\" data-start=\"2860\"\u003enot for flammables, solvents, or cooking oils\u003c\/strong\u003e. If your sample stream includes incompatible chemicals, you should use an alternate method. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"3096\" data-start=\"3041\"\u003e11) What are the key performance specs (speed\/RCF)?\u003c\/p\u003e\n\u003cp data-end=\"3209\" data-start=\"3097\"\u003eThe F-10300 is a \u003cstrong data-end=\"3132\" data-start=\"3114\"\u003efixed 3000 RPM\u003c\/strong\u003e unit and is listed at \u003cstrong data-end=\"3168\" data-start=\"3155\"\u003e1792g RCF\u003c\/strong\u003e. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"3246\" data-start=\"3211\"\u003e12) What power does it require?\u003c\/p\u003e\n\u003cp data-end=\"3521\" data-start=\"3247\"\u003eThe motor is listed as \u003cstrong data-end=\"3305\" data-start=\"3270\"\u003e110V (other voltages available)\u003c\/strong\u003e and uses a \u003cstrong data-end=\"3332\" data-start=\"3317\"\u003e1\/8 HP TEFC\u003c\/strong\u003e (totally enclosed fan-cooled) motor designed for industrial environments. If you need a non-standard voltage (e.g., 230V), confirm at time of order. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"3573\" data-start=\"3523\"\u003e13) How big is it, and how much does it weigh?\u003c\/p\u003e\n\u003cp data-end=\"3786\" data-start=\"3574\"\u003ePublished dimensions are approximately \u003cstrong data-end=\"3639\" data-start=\"3613\"\u003e16 in (41 cm) diameter\u003c\/strong\u003e by \u003cstrong data-end=\"3667\" data-start=\"3643\"\u003e13 in (33 cm) height\u003c\/strong\u003e. Net weight is listed around \u003cstrong data-end=\"3713\" data-start=\"3697\"\u003e20 lb (9 kg)\u003c\/strong\u003e (ship weight ~25 lb \/ 11.34 kg). \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"3824\" data-start=\"3788\"\u003e14) What warranty comes with it?\u003c\/p\u003e\n\u003cp data-end=\"3914\" data-start=\"3825\"\u003eThe F-10300 is listed with a \u003cstrong data-end=\"3873\" data-start=\"3854\"\u003e1-year warranty\u003c\/strong\u003e. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"3989\" data-start=\"3916\"\u003e15) If I need “official” MLSS numbers, what’s the correct lab method?\u003c\/p\u003e\n\u003cp data-end=\"4358\" data-start=\"3990\"\u003eIf you need defensible MLSS\/TSS numbers (mg\/L), operators commonly point to \u003cstrong data-end=\"4106\" data-start=\"4066\"\u003eStandard Methods (e.g., 2540 series)\u003c\/strong\u003e using glass fiber filters plus a controlled drying oven (commonly cited \u003cstrong data-end=\"4192\" data-start=\"4179\"\u003e103–105°C\u003c\/strong\u003e) and an analytical balance. The centrifuge is widely used as the fast day-of process tool, with lab methods as the reference.\u003c\/p\u003e","brand":"RavenEP","offers":[{"title":"F-10300 ~ ea","offer_id":47684887773443,"sku":"F-10300","price":2447.78,"currency_code":"CAD","in_stock":true},{"title":"B-10101-19 ~ pk\/12","offer_id":47684887806211,"sku":"B-10101-19","price":196.57,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/ProcessCentrifugeSide.png?v=1769453702","url":"https:\/\/cambridgeenviro.com\/products\/f-10300-process-centrifuge","provider":"Cambridge Environmental Products, Inc.","version":"1.0","type":"link"}