{"product_id":"burkle-zone-samplers-multi-uno-all-layer","title":"Burkle Zone Samplers – Multi, Uno \u0026 All-Layer Bulk Solids Samplers","description":"\u003ch2\u003eBürkle Zone Samplers – Multi, Uno \u0026amp; All-Layer Samplers for Bulk Solids, 316L Stainless Steel, 55–150 cm\u003c\/h2\u003e\n\u003cp\u003eBürkle zone samplers are sampling lances for taking samples of powders, granules and other bulk solids at depth, from sacks, drums, tubs, big bags and silos. Push the closed lance into the material, turn the handle to open it, and material flows in at the exact depths you've chosen. Then close it and withdraw it with the sample held inside. Choosing the right zone sampler lets you check whether a material is uniform from top to bottom, take a sample from one specific depth, or collect a single sample through all layers.\u003c\/p\u003e\n\u003cp\u003eFour types are available, each in 55, 85 and 150 cm lengths. \u003cstrong\u003eMulti Samplers\u003c\/strong\u003e (316L\/PTFE or all-316L) have separate chambers that keep a sample from each depth apart. The \u003cstrong\u003eUno Sampler\u003c\/strong\u003e takes one sample from one depth. The \u003cstrong\u003eAll-Layer Sampler\u003c\/strong\u003e collects material from every layer into one sample. Bürkle states the samplers are suitable for foodstuffs and autoclavable up to 121 °C. They're available in Canada from Cambridge Environmental Products with CAD pricing and Canadian purchasing support.\u003c\/p\u003e\n\u003cdiv style=\"border: 1px solid #d9d9d9; padding: 18px; margin: 24px 0; border-radius: 8px; background: #f8f8f8;\"\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35; margin-top: 0;\"\u003eIdeal For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFood and ingredient QA\/QC\u003c\/strong\u003e: sampling flour, sugar, starch, spices and powders from sacks and big bags\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePharmaceutical and chemical production\u003c\/strong\u003e: incoming raw material sampling and checking mixes for uniformity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgriculture and feed\u003c\/strong\u003e: sampling grain, seeds, pellets and feed in bags, bins and silos\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlastics and industrial QA\/QC\u003c\/strong\u003e: granules and pellets in drums, octabins and big bags\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eResearch laboratories, universities and colleges\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eWhy Choose Bürkle Zone Samplers?\u003c\/h2\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eSample exactly where you need to\u003c\/h3\u003e\n\u003cp\u003eBulk materials often separate in transport and storage, so the top of a bag may not match the bottom. Zone samplers take material from defined depths, so you can check uniformity layer by layer or build a sample that represents the whole container.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eThree sampling methods\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMulti Sampler:\u003c\/strong\u003e 3 or 5 separate chambers collect samples from several depths in one insertion and keep them apart for individual analysis. \u003cstrong\u003eUno Sampler:\u003c\/strong\u003e one closed chamber at the tip takes a targeted sample from a single depth. \u003cstrong\u003eAll-Layer Sampler:\u003c\/strong\u003e no chambers. Its 3 or 5 openings collect material from every layer into one sample.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eMinimal gap, removable tip\u003c\/h3\u003e\n\u003cp\u003eBürkle designs the lances with the smallest possible gap between the inner and outer tube, which reduces the risk of contamination and helps sampling accuracy. The tip is removable for thorough cleaning between samples.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eColour coding\u003c\/h3\u003e\n\u003cp\u003eThe Multi and Uno Samplers have colour-coded caps, so when several samplers are in use you can assign each one to a material and avoid mix-ups.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eFood-suitable and autoclavable\u003c\/h3\u003e\n\u003cp\u003eBürkle states its zone samplers are suitable for use with foodstuffs, produced to DIN standards, and autoclavable up to 121 °C for 20 minutes.\u003c\/p\u003e\n\u003ch2\u003eAvailable Models\u003c\/h2\u003e\n\u003cp\u003eChoose the \u003cstrong\u003eType\u003c\/strong\u003e, then the \u003cstrong\u003eLength\u003c\/strong\u003e. All lances are 25 mm in diameter.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 12px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #f2f2f2;\"\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 10px; text-align: left;\"\u003eCode\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 10px; text-align: left;\"\u003eType\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 10px; text-align: left;\"\u003eLength\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 10px; text-align: left;\"\u003eInsertion Depth\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 10px; text-align: left;\"\u003eSample Chambers \/ Volume\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e5316-0055\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eMulti Sampler – 316L\/PTFE\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e55 cm\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e430 mm\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e3 chambers × 14 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e5316-0085\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eMulti Sampler – 316L\/PTFE\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e85 cm\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e710 mm\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e3 chambers × 17 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e5316-0150\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eMulti Sampler – 316L\/PTFE\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e150 cm\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e1,355 mm\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e5 chambers × 17 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e5316-3055\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eMulti Sampler – 316L\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e55 cm\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e430 mm\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e3 chambers × 14 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e5316-3085\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eMulti Sampler – 316L\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e85 cm\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e710 mm\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e3 chambers × 17 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e5316-3150\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eMulti Sampler – 316L\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e150 cm\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e1,355 mm\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e5 chambers × 17 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e5316-1055\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eUno Sampler – 316L\/PTFE\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e55 cm\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e430 mm\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e1 chamber × 17 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e5316-1085\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eUno Sampler – 316L\/PTFE\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e85 cm\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e710 mm\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e1 chamber × 17 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e5316-1150\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eUno Sampler – 316L\/PTFE\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e150 cm\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e1,355 mm\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e1 chamber × 17 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e5316-2055\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eAll-Layer Sampler – 316L\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e55 cm\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e430 mm\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e3 openings, 70 mL total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e5316-2085\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eAll-Layer Sampler – 316L\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e85 cm\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e710 mm\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e3 openings, 130 mL total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e5316-2150\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eAll-Layer Sampler – 316L\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e150 cm\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e1,355 mm\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e5 openings, 260 mL total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are from Bürkle and Bürkle distributor listings (Avantor, Fisher Scientific, Thomas Scientific).\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eWhich Type and Length Should I Choose?\u003c\/h2\u003e\n\u003cdiv style=\"border: 1px solid #d9d9d9; padding: 18px; margin: 24px 0; border-radius: 8px; background: #f8f8f8;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti Sampler:\u003c\/strong\u003e to check whether a material is uniform, or to analyze several depths separately in one go.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e316L\/PTFE vs all-316L Multi Sampler:\u003c\/strong\u003e the 316L\/PTFE version has PTFE sample chambers, so it's lighter and more economical. The all-stainless version is very robust, even with abrasive particles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUno Sampler:\u003c\/strong\u003e when you need one targeted sample from a specific depth, such as the bottom of a bag.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-Layer Sampler:\u003c\/strong\u003e when you want one sample through the full depth of the container, for example for an average composition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e55 cm:\u003c\/strong\u003e sacks and bags. \u003cstrong\u003e85 cm:\u003c\/strong\u003e drums, barrels and tubs. \u003cstrong\u003e150 cm:\u003c\/strong\u003e big bags, silos and tanks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003cdiv style=\"border: 1px solid #d9d9d9; padding: 18px; margin: 24px 0; border-radius: 8px; background: #f8f8f8;\"\u003e\n\u003col style=\"margin: 0;\"\u003e\n\u003cli\u003eTurn the handle to close the sampler.\u003c\/li\u003e\n\u003cli\u003eInsert the closed lance into the bulk material to the required depth.\u003c\/li\u003e\n\u003cli\u003eTurn the handle to open the chambers or openings. Material flows in.\u003c\/li\u003e\n\u003cli\u003eTurn the handle to close the sampler again, then withdraw it.\u003c\/li\u003e\n\u003cli\u003eOpen the sampler over a clean surface, sample paper or tray, and empty the sample. Keep each chamber's sample separate when using a Multi Sampler.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003eSteps are summarized from Bürkle's instructions. Bürkle also offers accessories such as sealing sleeves, sample paper, cleaning brushes and emptying devices. Contact Cambridge for options.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eCommon Applications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 12px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #f2f2f2;\"\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 10px; text-align: left;\"\u003eApplication\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 10px; text-align: left;\"\u003eHow It Helps\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eIncoming raw material inspection\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eSamples sacks, drums and big bags at depth, not just at the surface.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eBlend uniformity checks\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eThe Multi Sampler keeps each depth separate, so differences between layers show up.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eRepresentative composite samples\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eThe All-Layer Sampler collects through the full depth in one insertion.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eTargeted sampling\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eThe Uno Sampler takes a sample from one chosen depth, such as the bottom of a container.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 12px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; width: 40%;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eBürkle GmbH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; width: 40%;\"\u003e\u003cstrong\u003eTypes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eMulti Sampler (316L\/PTFE or 316L), Uno Sampler (316L\/PTFE), All-Layer Sampler (316L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; width: 40%;\"\u003e\u003cstrong\u003eMaterials\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eStainless steel 1.4404 (AISI 316L); PTFE sample chambers on 316L\/PTFE models; Bürkle also lists NBR among further materials\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; width: 40%;\"\u003e\u003cstrong\u003eLance diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; width: 40%;\"\u003e\u003cstrong\u003eLengths \/ insertion depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e55 cm \/ 430 mm; 85 cm \/ 710 mm; 150 cm \/ 1,355 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; width: 40%;\"\u003e\u003cstrong\u003eTip\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003ePointed, removable for cleaning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; width: 40%;\"\u003e\u003cstrong\u003eColour coding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eMulti and Uno Samplers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; width: 40%;\"\u003e\u003cstrong\u003eSterilization\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eAutoclavable up to 121 °C for 20 min (per Bürkle)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; width: 40%;\"\u003e\u003cstrong\u003eFood contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eSuitable for use with foodstuffs (per Bürkle)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; width: 40%;\"\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eProduced according to DIN standards (per Bürkle)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; width: 40%;\"\u003e\u003cstrong\u003eSold as\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eEach\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications are from Bürkle product information and distributor listings.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eSelection \u0026amp; Handling Notes\u003c\/h2\u003e\n\u003cdiv style=\"border: 1px solid #d9d9d9; padding: 18px; margin: 24px 0; border-radius: 8px; background: #fff8e5;\"\u003e\n\u003cul style=\"margin: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eClose before inserting.\u003c\/strong\u003e Always close the sampler before inserting and withdrawing it, so material only enters at the target depth.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParticle size:\u003c\/strong\u003e the 25 mm lances suit fine powders through to granules. For very coarse material or larger quantities, ask Cambridge about Bürkle's larger-diameter samplers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrevent cross-contamination.\u003c\/strong\u003e Remove the tip and clean thoroughly between materials. Autoclave at up to 121 °C for 20 minutes where required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck chemical resistance\u003c\/strong\u003e of 316L, PTFE and NBR against the material you're sampling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDon't use the lance as a lever\u003c\/strong\u003e or force it through compacted material. The tube can bend.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous materials:\u003c\/strong\u003e follow the material's Safety Data Sheet and wear suitable protective equipment, including dust protection for fine powders.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eProduct Documents\u003ca href=\"https:\/\/buerkle.de\/en\/multi-stage-sampler-multi-sampler-316l-1-4404-ptfe_p465\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.buerkle.de\/en\/chemical-resistance\" rel=\"noopener\" target=\"_blank\"\u003eBürkle Chemical Resistance List\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed operating instructions, a material certificate or accessory information? \u003ca href=\"\/pages\/contact\"\u003eContact Cambridge\u003c\/a\u003e and we'll request it from Bürkle.\u003c\/p\u003e\n\u003ch2\u003eCanadian Purchasing Support\u003c\/h2\u003e\n\u003cp\u003eCambridge Environmental Products is a Canadian-owned laboratory supply distributor based in Ontario and has served Canadian labs since 1993. We supply Bürkle sampling equipment with CAD pricing and shipping across Canada. We work with food and ingredient manufacturers, pharmaceutical and chemical producers, agriculture and feed labs, plastics and industrial QA\/QC, and universities and colleges, and can help with quotes and choosing the right sampler. Browse our \u003ca href=\"\/collections\/lab-supplies\"\u003elab supplies\u003c\/a\u003e collection for more.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdetails style=\"border-bottom: 1px solid #ddd; padding: 13px 0;\"\u003e\n\u003csummary style=\"cursor: pointer; font-weight: 600;\"\u003eWhat is a zone sampler?\u003c\/summary\u003e\n\u003cp\u003eA sampling lance for bulk solids. It's inserted closed, opened at depth to collect material, then closed and withdrawn with the sample inside.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border-bottom: 1px solid #ddd; padding: 13px 0;\"\u003e\n\u003csummary style=\"cursor: pointer; font-weight: 600;\"\u003eWhat's the difference between the Multi, Uno and All-Layer Samplers?\u003c\/summary\u003e\n\u003cp\u003eThe Multi Sampler has 3 or 5 separate chambers for samples from several depths, kept apart. The Uno Sampler has one chamber for one depth. The All-Layer Sampler has no chambers and collects one sample through all layers.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border-bottom: 1px solid #ddd; padding: 13px 0;\"\u003e\n\u003csummary style=\"cursor: pointer; font-weight: 600;\"\u003eShould I choose 316L\/PTFE or all-316L?\u003c\/summary\u003e\n\u003cp\u003e316L\/PTFE is lighter and more economical, thanks to its PTFE sample chambers. All-316L is the most robust option, including for abrasive materials.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border-bottom: 1px solid #ddd; padding: 13px 0;\"\u003e\n\u003csummary style=\"cursor: pointer; font-weight: 600;\"\u003eWhich length do I need?\u003c\/summary\u003e\n\u003cp\u003e55 cm for sacks, 85 cm for drums, barrels and tubs, and 150 cm for big bags, silos and tanks.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border-bottom: 1px solid #ddd; padding: 13px 0;\"\u003e\n\u003csummary style=\"cursor: pointer; font-weight: 600;\"\u003eCan zone samplers be autoclaved?\u003c\/summary\u003e\n\u003cp\u003eYes. Bürkle states they're autoclavable up to 121 °C for 20 minutes.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border-bottom: 1px solid #ddd; padding: 13px 0;\"\u003e\n\u003csummary style=\"cursor: pointer; font-weight: 600;\"\u003eAre they suitable for food?\u003c\/summary\u003e\n\u003cp\u003eBürkle states its zone samplers are suitable for use with foodstuffs.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border-bottom: 1px solid #ddd; padding: 13px 0;\"\u003e\n\u003csummary style=\"cursor: pointer; font-weight: 600;\"\u003eWhat materials can they sample?\u003c\/summary\u003e\n\u003cp\u003eBulk solids from fine powders to granules and grains. For very coarse material, ask about Bürkle's larger samplers.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border-bottom: 1px solid #ddd; padding: 13px 0;\"\u003e\n\u003csummary style=\"cursor: pointer; font-weight: 600;\"\u003eAre Bürkle zone samplers available in Canada?\u003c\/summary\u003e\n\u003cp\u003eYes. Cambridge Environmental Products supplies Bürkle zone samplers across Canada with CAD pricing.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdiv style=\"border: 1px solid #d9d9d9; padding: 18px; margin: 24px 0; border-radius: 8px; background: #f8f8f8;\"\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35; margin-top: 0;\"\u003eNeed Help Choosing a Zone Sampler?\u003c\/h3\u003e\n\u003cp\u003eTell us:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe material you sample (powder, granules, grain) and its particle size\u003c\/li\u003e\n\u003cli\u003eThe container (sack, drum, big bag, silo) and its depth\u003c\/li\u003e\n\u003cli\u003eWhether you need separate samples per depth, one depth, or one composite sample\u003c\/li\u003e\n\u003cli\u003eWhether the sampler must be autoclaved or used with food\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe'll recommend the right type and length.\u003c\/p\u003e\n\u003ca href=\"\/pages\/contact\" style=\"display: inline-block; padding: 12px 18px; background: #1f4e79; color: #ffffff; text-decoration: none; border-radius: 5px; font-weight: bold;\"\u003e Contact Cambridge for Product Support \u003c\/a\u003e\n\u003c\/div\u003e","brand":"Burkle","offers":[{"title":"Multi Sampler – 316L\/PTFE \/ 55 cm","offer_id":50316045385987,"sku":"5316-0055","price":1402.34,"currency_code":"CAD","in_stock":true},{"title":"Multi Sampler – 316L\/PTFE \/ 85 cm","offer_id":50316045418755,"sku":"5316-0085","price":1582.57,"currency_code":"CAD","in_stock":true},{"title":"Multi Sampler – 316L\/PTFE \/ 150 cm","offer_id":50316045451523,"sku":"5316-0150","price":2318.12,"currency_code":"CAD","in_stock":true},{"title":"Multi Sampler – 316L \/ 55 cm","offer_id":50316045484291,"sku":"5316-3055","price":2100.98,"currency_code":"CAD","in_stock":true},{"title":"Multi Sampler – 316L \/ 85 cm","offer_id":50316045517059,"sku":"5316-3085","price":2260.57,"currency_code":"CAD","in_stock":true},{"title":"Multi Sampler – 316L \/ 150 cm","offer_id":50316045549827,"sku":"5316-3150","price":2883.13,"currency_code":"CAD","in_stock":true},{"title":"Uno Sampler – 316L\/PTFE \/ 55 cm","offer_id":50316045582595,"sku":"5316-1055","price":1431.25,"currency_code":"CAD","in_stock":true},{"title":"Uno Sampler – 316L\/PTFE \/ 85 cm","offer_id":50316045615363,"sku":"5316-1085","price":1613.2,"currency_code":"CAD","in_stock":true},{"title":"Uno Sampler – 316L\/PTFE \/ 150 cm","offer_id":50316045648131,"sku":"5316-1150","price":2370.16,"currency_code":"CAD","in_stock":true},{"title":"All-Layer Sampler – 316L \/ 55 cm","offer_id":50316045680899,"sku":"5316-2055","price":1919.77,"currency_code":"CAD","in_stock":true},{"title":"All-Layer Sampler – 316L \/ 85 cm","offer_id":50316045713667,"sku":"5316-2085","price":2222.06,"currency_code":"CAD","in_stock":true},{"title":"All-Layer Sampler – 316L \/ 150 cm","offer_id":50316045746435,"sku":"5316-2150","price":2694.02,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/5316-xxxx_Multi-Sammler_V4A_mit_farbcodierung_freigestellt.png?v=1794933816","url":"https:\/\/cambridgeenviro.com\/products\/burkle-zone-samplers-multi-uno-all-layer","provider":"Cambridge Environmental Products, Inc.","version":"1.0","type":"link"}