Shopping Cart

Single Point Load Cells 600g (1.2 lb)

SKU: LC-4101-G600~ea

SKU: LC-4101-G600~ea

Usually Ships in 7 to 10 business days

Get a Quote

Description

Features
Parallelogram-type construction
Temperature compensation maintains both zero and span from -10 °C to +40 °C/+14 °F to +104 °F
Deadweight up to 80% of capacity. Load weight and deadweight up to 180% of capacity
Moisture proof
Compact and lightweight
Can be used for capacities as light as 600 g
Specifications
Rated capacities........................ 600 gf, 1.5 kgf, 3 kgf, 0 kgf,15 kgf
Rated output ..............................1 mV/V+15/-0%
Maximum deadweight ................80% of rated capacity
Maximum safe overload ............300% of rated capacity
Combined error .........................±0.015% of rated output
Creep .........................................±0.05% of rated output/hour
Zero balance ..............................20±5% of rated output
Compensated
temperature range..................... -10 °C to +40 °C/+14 °F to +104 °F
Recommended
excitation voltage ........................12 V
Maximum
excitation voltage .........................1 5 V
Input terminal resistance............ Approximately 400 Ω
Output terminal resistance .........350 ± 5 Ω
Insulation resistance ..................Greater than 5000 MΩ at DC50 V
Temperature effect
Zero ...........................................0.004% of rated output/°C
Span ..........................................0.0014% of rated output/ Type.
Platform size ..............................300 × 300 mm/11.8 × 11.8 inches
Cable length ..............................1.5 m / 59 inches

Download(s) Available: AND Load Cell Literature