{"product_id":"accuris-quantification-kit","title":"Accuris Quantification Kits for dsDNA, ssDNA \u0026 RNA","description":"\u003ch2\u003eAccuris Quantification Kits for dsDNA, ssDNA \u0026amp; RNA\u003c\/h2\u003e\n\n\u003cp\u003e\n  \u003cstrong\u003eAccuris Quantification Kits\u003c\/strong\u003e provide fluorescence-based measurement of \u003cstrong\u003edouble-stranded DNA (dsDNA), single-stranded DNA (ssDNA), and RNA\u003c\/strong\u003e for molecular biology laboratories that need greater sensitivity and target selectivity than conventional UV-absorbance measurements can provide.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  The family includes \u003cstrong\u003eHigh Sensitivity, Broad Range, and convenient 1X dsDNA assays\u003c\/strong\u003e, plus dedicated ssDNA and RNA formulations. Kits are available in 100- and 500-assay formats to support routine research through higher-volume molecular biology workflows.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  Accuris kits are designed for use with compatible fluorometers including \u003cstrong\u003eAccuris Smart-Q™, Smart-Q™ Mini, SmartDrop™ XF, Invitrogen Qubit® fluorometers, and suitable fluorescence microplate readers\u003c\/strong\u003e.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  Each assay uses fluorescent dye chemistry that increases in signal when associated with the target nucleic acid. This allows low-concentration DNA or RNA samples to be quantified more selectively than by measuring total UV absorbance alone.\n\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n  \u003ch3 style=\"margin-top:0; font-size:18px; line-height:1.35;\"\u003eChoose Your Accuris Quantification Kit\u003c\/h3\u003e\n\n  \u003cul style=\"margin-bottom:0;\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eVery low dsDNA concentrations:\u003c\/strong\u003e High Sensitivity dsDNA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHigher or widely varying dsDNA concentrations:\u003c\/strong\u003e Broad Range dsDNA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eReduce reagent-preparation steps:\u003c\/strong\u003e 1X High Sensitivity or 1X Broad Range dsDNA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSingle-stranded DNA or oligonucleotides:\u003c\/strong\u003e ssDNA Quantification Kit\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eLow-concentration RNA:\u003c\/strong\u003e RNA High Sensitivity\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHigher-concentration RNA:\u003c\/strong\u003e RNA Broad Range\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSmart-Q 100 \/ compatible fluorometer measurements:\u003c\/strong\u003e F1001-T 0.5 mL fluorescence detection tubes\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eAccuris Quantification Kit Comparison\u003c\/h2\u003e\n\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px; min-width:900px;\"\u003e\n  \u003ctbody\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eAssay\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eTarget\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eInitial Sample Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eFormats\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eBest Fit\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\u003cstrong\u003edsDNA High Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003edsDNA\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e0.005–120 ng\/µL\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eStandard or 1X\u003cbr\u003e100 \/ 500 assays\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eLow-concentration DNA samples\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\u003cstrong\u003edsDNA Broad Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003edsDNA\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e0.1–1,000 ng\/µL\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eStandard or 1X\u003cbr\u003e100 \/ 500 assays\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eRoutine DNA quantification across a wider concentration range\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\u003cstrong\u003essDNA\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003essDNA \/ oligonucleotides\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e0.05–200 ng\/µL\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e100 \/ 500 assays\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSingle-stranded DNA and oligo quantification\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\u003cstrong\u003eRNA High Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eRNA\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e0.1–100 ng\/µL\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e100 \/ 500 assays\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eLow-concentration RNA samples\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\u003cstrong\u003eRNA Broad Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eRNA\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e1–1,000 ng\/µL\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e100 \/ 500 assays\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eRoutine RNA samples with higher concentrations\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eHigh Sensitivity vs. Broad Range: Which Kit Do I Need?\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eChoose High Sensitivity for Low-Concentration Samples\u003c\/h3\u003e\n\n\u003cp\u003e\n  The \u003cstrong\u003eHigh Sensitivity dsDNA kit\u003c\/strong\u003e is intended for samples containing approximately \u003cstrong\u003e0.005–120 ng\/µL dsDNA\u003c\/strong\u003e.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  This makes it useful when sample concentration is low or when conserving a limited DNA sample is important.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  The \u003cstrong\u003eRNA High Sensitivity kit\u003c\/strong\u003e performs a similar role for RNA samples between approximately \u003cstrong\u003e0.1 and 100 ng\/µL\u003c\/strong\u003e.\n\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eChoose Broad Range for Higher Concentrations\u003c\/h3\u003e\n\n\u003cp\u003e\n  The \u003cstrong\u003eBroad Range dsDNA kit\u003c\/strong\u003e covers approximately \u003cstrong\u003e0.1–1,000 ng\/µL\u003c\/strong\u003e, making it useful for routine DNA samples where concentrations may vary substantially.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  For RNA, the \u003cstrong\u003eBroad Range RNA kit\u003c\/strong\u003e covers approximately \u003cstrong\u003e1–1,000 ng\/µL\u003c\/strong\u003e.\n\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n  \u003ch3 style=\"margin-top:0; font-size:18px; line-height:1.35;\"\u003eNot Sure Which Range Your Sample Falls Into?\u003c\/h3\u003e\n\n  \u003cp style=\"margin-bottom:0;\"\u003e\n    If expected concentrations may fall near the limits of two assay ranges, consider your extraction method, expected yield, sample dilution and downstream workflow before choosing. Cambridge can help compare the High Sensitivity and Broad Range options for your application.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eStandard vs. 1X dsDNA Quantification Kits\u003c\/h2\u003e\n\n\u003cp\u003e\n  Accuris offers both conventional and \u003cstrong\u003e1X pre-mixed versions\u003c\/strong\u003e of its High Sensitivity and Broad Range dsDNA assays.\n\u003c\/p\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n  \u003ctbody\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eFormat\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eWhat It Means\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eWhy Choose It?\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eFluorescent reagent and buffer are supplied for preparation of the working solution.\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eTraditional assay preparation and flexibility.\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\u003cstrong\u003e1X\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003ePre-mixed fluorescent working solution.\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eFewer pipetting and preparation steps and improved workflow consistency.\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\n  The 1X format is particularly useful in laboratories running frequent assays or where simplifying reagent preparation can reduce operator-to-operator variation.\n\u003c\/p\u003e\n\n\u003ch2\u003edsDNA High Sensitivity Quantification Kits\u003c\/h2\u003e\n\n\u003cp\u003e\n  Accuris High Sensitivity dsDNA kits are designed for accurate quantification of low-concentration double-stranded DNA samples from approximately \u003cstrong\u003e0.005 to 120 ng\/µL\u003c\/strong\u003e.\n\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eF1000-HS-100:\u003c\/strong\u003e High Sensitivity dsDNA Kit – 100 assays\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eF1000-HS-500:\u003c\/strong\u003e High Sensitivity dsDNA Kit – 500 assays\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eF1000-HS1-100:\u003c\/strong\u003e 1X High Sensitivity dsDNA Kit – 100 assays\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eF1000-HS1-500:\u003c\/strong\u003e 1X High Sensitivity dsDNA Kit – 500 assays\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\n  Accuris' standard High Sensitivity dsDNA protocol accepts approximately \u003cstrong\u003e1–20 µL of sample\u003c\/strong\u003e, with the sample and working solution brought to the specified final assay volume.\n\u003c\/p\u003e\n\n\u003ch2\u003edsDNA Broad Range Quantification Kits\u003c\/h2\u003e\n\n\u003cp\u003e\n  Broad Range kits are designed for laboratories measuring DNA samples over a wider and generally higher concentration range.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  Accuris currently specifies an initial sample range of approximately \u003cstrong\u003e0.1–1,000 ng\/µL\u003c\/strong\u003e for the current F1000 Broad Range family.\n\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eF1000-BR-100:\u003c\/strong\u003e Broad Range dsDNA Kit – 100 assays\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eF1000-BR-500:\u003c\/strong\u003e Broad Range dsDNA Kit – 500 assays\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eF1000-BR1-100:\u003c\/strong\u003e 1X Broad Range dsDNA Kit – 100 assays\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eF1000-BR1-500:\u003c\/strong\u003e 1X Broad Range dsDNA Kit – 500 assays\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003essDNA Quantification Kits\u003c\/h2\u003e\n\n\u003cp\u003e\n  The Accuris \u003cstrong\u003essDNA Quantification Kit\u003c\/strong\u003e is designed for measurement of single-stranded DNA and oligonucleotides between approximately \u003cstrong\u003e0.05 and 200 ng\/µL\u003c\/strong\u003e.\n\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eF1000-SD-100:\u003c\/strong\u003e ssDNA Quantification Kit – 100 assays\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eF1000-SD-500:\u003c\/strong\u003e ssDNA Quantification Kit – 500 assays\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#fff8e5;\"\u003e\n  \u003ch3 style=\"margin-top:0; font-size:18px; line-height:1.35;\"\u003eImportant ssDNA Selectivity Note\u003c\/h3\u003e\n\n  \u003cp style=\"margin-bottom:0;\"\u003e\n    Accuris states that the ssDNA assay is suitable for ssDNA and oligonucleotide measurement but is \u003cstrong\u003enot selective for ssDNA over dsDNA or RNA\u003c\/strong\u003e. If your sample contains meaningful amounts of multiple nucleic-acid types, consider whether that cross-response is acceptable for your method.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eRNA High Sensitivity Quantification Kits\u003c\/h2\u003e\n\n\u003cp\u003e\n  The \u003cstrong\u003eRNA High Sensitivity\u003c\/strong\u003e assay is designed for RNA concentrations from approximately \u003cstrong\u003e0.1 to 100 ng\/µL\u003c\/strong\u003e.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  Accuris describes this assay as highly selective for RNA over both double-stranded and single-stranded DNA.\n\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eF1000-RHS-100:\u003c\/strong\u003e RNA High Sensitivity Kit – 100 assays\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eF1000-RHS-500:\u003c\/strong\u003e RNA High Sensitivity Kit – 500 assays\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eRNA Broad Range Quantification Kits\u003c\/h2\u003e\n\n\u003cp\u003e\n  The \u003cstrong\u003eRNA Broad Range\u003c\/strong\u003e assay is designed for RNA samples between approximately \u003cstrong\u003e1 and 1,000 ng\/µL\u003c\/strong\u003e.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  This formulation is intended for higher-concentration RNA samples and is described by Accuris as highly specific for RNA over ssDNA and dsDNA.\n\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eF1000-RBR-100:\u003c\/strong\u003e RNA Broad Range Kit – 100 assays\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eF1000-RBR-500:\u003c\/strong\u003e RNA Broad Range Kit – 500 assays\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhy Fluorescence Instead of UV Absorbance?\u003c\/h2\u003e\n\n\u003cp\u003e\n  UV spectrophotometers estimate nucleic-acid concentration by measuring absorbance, typically around 260 nm. This approach is convenient but may also respond to other UV-absorbing material in the sample.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  Fluorescence-based assays use dyes designed to respond preferentially to a target molecule. This can provide \u003cstrong\u003egreater sensitivity and target selectivity\u003c\/strong\u003e, particularly when working with low-concentration samples or samples containing other substances that may interfere with absorbance measurements.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  Accuris states that its quantification assays are minimally affected by common contaminants such as proteins, salts or solvents, although the exact selectivity depends on the assay formulation.\n\u003c\/p\u003e\n\n\u003ch2\u003eHow Accuris Fluorescent Quantification Works\u003c\/h2\u003e\n\n\u003cp\u003e\n  Each assay combines the sample with a fluorescent reagent formulated for the target nucleic acid. Standards supplied with the kit are used to establish the calibration relationship required by the fluorometer.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  Accuris specifies compatible detection using approximately \u003cstrong\u003e460 ± 20 nm blue excitation\u003c\/strong\u003e and \u003cstrong\u003e525–570 nm green fluorescence emission\u003c\/strong\u003e.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  Once the appropriate standards and unknown samples have been prepared, a compatible fluorometer measures fluorescence intensity and calculates the nucleic-acid concentration from the calibration curve.\n\u003c\/p\u003e\n\n\u003ch2\u003eWhat's Included in an Accuris Quantification Kit?\u003c\/h2\u003e\n\n\u003cp\u003e\n  Kit contents vary somewhat by assay formulation, but Accuris quantification kits generally include the materials needed to prepare and calibrate the fluorescent assay, including:\n\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003eFluorescent assay reagent\u003c\/li\u003e\n  \u003cli\u003eAssay buffer or pre-mixed working solution, depending on kit format\u003c\/li\u003e\n  \u003cli\u003eReady-to-use nucleic-acid standards\u003c\/li\u003e\n  \u003cli\u003eAssay protocol \/ instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\n  Fluorescence detection tubes are available separately.\n\u003c\/p\u003e\n\n\u003ch2\u003eF1001-T – 0.5 mL Fluorescence Detection Tubes\u003c\/h2\u003e\n\n\u003cp\u003e\n  \u003cstrong\u003eF1001-T\u003c\/strong\u003e is a pack of \u003cstrong\u003e250 optically suitable 0.5 mL fluorescence detection tubes\u003c\/strong\u003e for compatible Accuris fluorometer workflows.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  The tubes are listed by Accuris for use with the Smart-Q 100 platform and related compatible assays.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  Because F1001-T is a consumable rather than a quantification reagent kit, Cambridge should clearly identify it as a \u003cstrong\u003edetection-tube accessory\u003c\/strong\u003e in the variant selector.\n\u003c\/p\u003e\n\n\u003ch2\u003eCompatible Fluorometers\u003c\/h2\u003e\n\n\u003cp\u003e\n  Accuris Quantification Kits are designed for use with fluorescence instruments that provide the required excitation and emission wavelengths.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  Accuris specifically identifies compatibility with:\n\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n    \u003ca href=\"\/products\/accuris-smart-q-mini-fluorometer-canada\"\u003e\n      \u003cstrong\u003eAccuris Smart-Q™ Mini Fluorometer\u003c\/strong\u003e\n    \u003c\/a\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eAccuris Smart-Q™ fluorometers\u003c\/strong\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eAccuris SmartDrop™ XF\u003c\/strong\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eInvitrogen Qubit® fluorometers\u003c\/strong\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eCompatible fluorescence microplate readers\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\n  Always confirm that the instrument provides the excitation\/emission requirements and tube or plate format needed by the selected assay.\n\u003c\/p\u003e\n\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\n\u003cp\u003e\n  Fluorescence-based nucleic-acid quantification is commonly used before downstream molecular biology procedures where accurate input concentration is important.\n\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003eNext-generation sequencing library preparation\u003c\/li\u003e\n  \u003cli\u003ePCR and qPCR workflows\u003c\/li\u003e\n  \u003cli\u003eDNA and RNA extraction QC\u003c\/li\u003e\n  \u003cli\u003eCloning and molecular biology workflows\u003c\/li\u003e\n  \u003cli\u003eOligonucleotide and ssDNA quantification\u003c\/li\u003e\n  \u003cli\u003eRNA workflow preparation\u003c\/li\u003e\n  \u003cli\u003eAcademic and research laboratories\u003c\/li\u003e\n  \u003cli\u003eBiotechnology and life-science laboratories\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhich Accuris Quantification Kit Should I Choose?\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n  \u003ctbody\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eIf You Need To...\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f8f8f8;\"\u003e\u003cstrong\u003eChoose\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMeasure very low concentrations of dsDNA\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eF1000-HS High Sensitivity dsDNA\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMeasure dsDNA over a broad concentration range\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eF1000-BR Broad Range dsDNA\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eReduce reagent-preparation steps\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eF1000-HS1 or F1000-BR1 1X formulation\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMeasure ssDNA or oligonucleotides\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eF1000-SD ssDNA Kit\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMeasure low-concentration RNA\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eF1000-RHS RNA High Sensitivity\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMeasure higher-concentration RNA\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eF1000-RBR RNA Broad Range\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eReplace Smart-Q 100 assay tubes\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eF1001-T 0.5 mL Detection Tubes\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhat is the difference between High Sensitivity and Broad Range DNA kits?\u003c\/h3\u003e\n\n\u003cp\u003e\n  The High Sensitivity dsDNA kit is optimized for low DNA concentrations from approximately 0.005–120 ng\/µL. The Broad Range kit covers approximately 0.1–1,000 ng\/µL and is better suited to samples expected to contain higher or more variable concentrations of dsDNA.\n\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhat is the difference between the standard and 1X kits?\u003c\/h3\u003e\n\n\u003cp\u003e\n  Standard kits require preparation of the fluorescent working solution from the supplied reagent and buffer. The 1X versions provide a pre-mixed working solution, reducing preparation and pipetting steps.\n\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eAre Accuris Quantification Kits compatible with Qubit fluorometers?\u003c\/h3\u003e\n\n\u003cp\u003e\n  Yes. Accuris identifies its quantification kits as compatible with Invitrogen Qubit® fluorometers as well as Accuris Smart-Q instruments, SmartDrop XF and suitable fluorescence microplate readers.\n\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eCan I use these kits with the Accuris Smart-Q Mini?\u003c\/h3\u003e\n\n\u003cp\u003e\n  Yes. Accuris lists its quantification kits as compatible with the Smart-Q Mini fluorometer, which is designed for fluorescence-based measurement of nucleic acids and related assays.\n\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhich Accuris kit should I use for low-concentration DNA?\u003c\/h3\u003e\n\n\u003cp\u003e\n  The F1000-HS High Sensitivity dsDNA family is designed for initial dsDNA concentrations from approximately 0.005–120 ng\/µL.\n\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhich kit should I use for RNA?\u003c\/h3\u003e\n\n\u003cp\u003e\n  Choose RNA High Sensitivity for approximately 0.1–100 ng\/µL RNA and RNA Broad Range for approximately 1–1,000 ng\/µL.\n\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eCan the ssDNA kit distinguish ssDNA from dsDNA and RNA?\u003c\/h3\u003e\n\n\u003cp\u003e\n  No. Accuris states that the ssDNA kit can quantify ssDNA and oligonucleotides but is not selective for ssDNA over dsDNA or RNA. Consider the composition of the sample before interpreting the result as specifically ssDNA.\n\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhy use fluorescent DNA quantification instead of a NanoDrop-style absorbance measurement?\u003c\/h3\u003e\n\n\u003cp\u003e\n  Fluorescent assays use target-responsive dyes and can provide greater sensitivity and selectivity at low nucleic-acid concentrations. UV absorbance measures total absorbance and may be more influenced by other UV-absorbing substances in the sample.\n\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHow much sample is required?\u003c\/h3\u003e\n\n\u003cp\u003e\n  Sample requirements vary by assay protocol. For example, Accuris' standard dsDNA protocols accommodate approximately 1–20 µL of sample. Follow the instructions supplied with the selected kit for the exact workflow.\n\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eDo the kits include calibration standards?\u003c\/h3\u003e\n\n\u003cp\u003e\n  Yes. Accuris quantification kits include ready-to-use standards for establishing the fluorescence calibration required to quantify unknown samples.\n\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eAre fluorescence detection tubes included?\u003c\/h3\u003e\n\n\u003cp\u003e\n  Detection tubes are available separately. F1001-T contains 250 compatible 0.5 mL fluorescence detection tubes.\n\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eAre 100- and 500-assay kits available?\u003c\/h3\u003e\n\n\u003cp\u003e\n  Yes. Accuris offers the dsDNA, ssDNA and RNA quantification kit families in both 100- and 500-assay formats.\n\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhere can I buy Accuris DNA and RNA quantification kits in Canada?\u003c\/h3\u003e\n\n\u003cp\u003e\n  Cambridge Environmental Products supplies Accuris fluorescence quantification kits and compatible fluorometry equipment in Canada with CAD pricing and support for Canadian research, academic, biotechnology and molecular biology laboratories.\n\u003c\/p\u003e\n\n\u003ch2\u003eCanadian Purchasing Support\u003c\/h2\u003e\n\n\u003cp\u003e\n  Cambridge Environmental Products supplies Accuris molecular biology equipment, fluorometers, nucleic-acid quantification kits and laboratory consumables across Canada.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  If you are unsure which assay range is appropriate, send us the \u003cstrong\u003etarget molecule, expected concentration range, fluorometer model, approximate number of samples per month and downstream application\u003c\/strong\u003e. We can help identify the most suitable Accuris kit and package size.\n\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:22px; margin-top:32px; border-radius:8px; background:#f8f8f8;\"\u003e\n  \u003ch2 style=\"margin-top:0;\"\u003eNeed Help Choosing a DNA or RNA Quantification Kit?\u003c\/h2\u003e\n\n  \u003cp\u003e\n    Selecting the correct assay depends primarily on the target molecule, expected concentration range, sample volume and fluorometer being used.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    \u003cstrong\u003eSend Cambridge your application and expected sample concentration and we can help compare the Accuris High Sensitivity, Broad Range, ssDNA and RNA quantification options.\u003c\/strong\u003e\n  \u003c\/p\u003e\n\n  \u003cp style=\"margin-bottom:0;\"\u003e\n    \u003ca href=\"\/pages\/contact\" style=\"display:inline-block; padding:12px 18px; background:#1f4e79; color:#ffffff; text-decoration:none; border-radius:5px; font-weight:bold;\"\u003e\n      Contact Cambridge for Quantification Kit Support\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\u003c\/div\u003e","brand":"Accuris Instruments","offers":[{"title":"Kit Size \/ F1000-HS-100","offer_id":48473095405827,"sku":"F1000-HS-100","price":200.39,"currency_code":"CAD","in_stock":false},{"title":"Kit Size \/ F1000-HS-500","offer_id":48473095438595,"sku":"F1000-HS-500","price":487.74,"currency_code":"CAD","in_stock":false},{"title":"Kit Size \/ F1000-HS1-100","offer_id":48473137479939,"sku":"F1000-HS1-100","price":205.17,"currency_code":"CAD","in_stock":false},{"title":"Kit Size \/ F1000-HS1-500","offer_id":48473137512707,"sku":"F1000-HS1-500","price":512.76,"currency_code":"CAD","in_stock":false},{"title":"Kit Size \/ F1000-BR-100","offer_id":48473137545475,"sku":"F1000-BR-100","price":171.9,"currency_code":"CAD","in_stock":false},{"title":"Kit Size \/ F1000-BR-500","offer_id":48473137578243,"sku":"F1000-BR-500","price":411.66,"currency_code":"CAD","in_stock":false},{"title":"Kit Size \/ F1000-BR1-100","offer_id":48473137611011,"sku":"F1000-BR1-100","price":176.19,"currency_code":"CAD","in_stock":false},{"title":"Kit Size \/ F1000-BR1-500","offer_id":48473137643779,"sku":"F1000-BR1-500","price":432.51,"currency_code":"CAD","in_stock":false},{"title":"Kit Size \/ F1000-SD-100","offer_id":48473137676547,"sku":"F1000-SD-100","price":172.21,"currency_code":"CAD","in_stock":false},{"title":"Kit Size \/ F1000-SD-500","offer_id":48473137709315,"sku":"F1000-SD-500","price":411.66,"currency_code":"CAD","in_stock":false},{"title":"Kit Size \/ F1000-RHS-100","offer_id":48473137742083,"sku":"F1000-RHS-100","price":172.21,"currency_code":"CAD","in_stock":false},{"title":"Kit Size \/ F1000-RHS-500","offer_id":48473137774851,"sku":"F1000-RHS-500","price":411.66,"currency_code":"CAD","in_stock":false},{"title":"Kit Size \/ F1000-RBR-100","offer_id":48473137807619,"sku":"F1000-RBR-100","price":172.21,"currency_code":"CAD","in_stock":false},{"title":"Kit Size \/ F1000-RBR-500","offer_id":48473137840387,"sku":"F1000-RBR-500","price":411.66,"currency_code":"CAD","in_stock":false},{"title":"Kit Size \/ F1001-T","offer_id":48473137873155,"sku":"F1001-T","price":107.6,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/F1000-Standard-Kits.png?v=1782401044","url":"https:\/\/cambridgeenviro.com\/products\/accuris-quantification-kit","provider":"Cambridge Environmental Products, Inc.","version":"1.0","type":"link"}