{"product_id":"hygiena-supersnap-high-sensitivity-atp-test","title":"Hygiena SuperSnap® High Sensitivity Surface ATP Test – 100 Tests","description":"\u003ch2\u003eHygiena SuperSnap® High Sensitivity Surface ATP Test – 100 Tests\u003c\/h2\u003e\n\n\u003cp\u003eHygiena SuperSnap is Hygiena's most sensitive surface ATP test. It's a single-use swab with a built-in liquid-stable reagent that detects very low levels of ATP, the energy molecule found in food residue, microorganisms and other organic matter. Swab the surface, snap and squeeze to activate, then read the result in a Hygiena luminometer in about 10 to 15 seconds. You can confirm a surface is clean before production starts, instead of waiting for lab results.\u003c\/p\u003e\n\n\u003cp\u003eSuperSnap is designed for sites with the strictest hygiene standards, such as high-risk food and beverage production, where a standard ATP swab may not pick up low-level residue. It's sold in boxes of 100 tests and works with all Hygiena luminometers, including the EnSURE Touch, EnSURE and SystemSURE Plus. Hygiena SuperSnap is available in Canada from Cambridge Environmental Products with CAD pricing and Canadian purchasing support.\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003ch3 style=\"font-size:18px; line-height:1.35; margin-top:0;\"\u003eIdeal For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFood and beverage processing\u003c\/strong\u003e: verifying cleaning of food-contact surfaces before start-up\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-risk and ready-to-eat production areas\u003c\/strong\u003e that need very low pass thresholds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSanitation SOP verification\u003c\/strong\u003e and pre-operational inspections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHACCP and preventive control programs\u003c\/strong\u003e that use ATP as a cleaning verification tool\u003c\/li\u003e\n\u003cli\u003eSites already using \u003cstrong\u003eHygiena luminometers\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eWhy Choose SuperSnap?\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHygiena's most sensitive surface ATP test\u003c\/h3\u003e\n\u003cp\u003eHygiena states SuperSnap is 4 times more sensitive than its UltraSnap surface test. Higher sensitivity means the test can pick up smaller amounts of residue, so you can set tighter pass limits on critical surfaces.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eResistant to sanitizer effects\u003c\/h3\u003e\n\u003cp\u003eLeftover sanitizer can suppress the ATP reaction and give falsely low readings. Hygiena states the SuperSnap reagent is 5 times more resistant to acid-based sanitizers and 10 times more resistant to alkali-based sanitizers.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eResults in seconds\u003c\/h3\u003e\n\u003cp\u003eResults take about 10 seconds on the EnSURE Touch and 15 seconds on the EnSURE or SystemSURE Plus. Staff can re-clean and re-test a surface on the spot instead of waiting for lab results.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eAll-in-one device\u003c\/h3\u003e\n\u003cp\u003eThe swab, reagent and cuvette are in one self-contained device, so there's no pipetting or separate reagent to handle. Hygiena's patented swab design is built for high sample collection and recovery, and the plastic is 100% recyclable.\u003c\/p\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003col style=\"margin:0;\"\u003e\n\u003cli\u003eLet the device warm to room temperature (21–25 °C) before use.\u003c\/li\u003e\n\u003cli\u003eTwist and pull the swab out of the tube.\u003c\/li\u003e\n\u003cli\u003eSwab a 10 × 10 cm area in a crisscross pattern, rotating the swab and pressing firmly enough to flex the shaft.\u003c\/li\u003e\n\u003cli\u003eReturn the swab to the tube.\u003c\/li\u003e\n\u003cli\u003eBend the bulb back and forth to break the Snap-Valve, then squeeze the bulb twice to release the liquid.\u003c\/li\u003e\n\u003cli\u003eShake for 5 to 10 seconds to soak the swab tip.\u003c\/li\u003e\n\u003cli\u003eInsert the device into the luminometer and start the reading \u003cstrong\u003ewithin 30 seconds\u003c\/strong\u003e of activating it.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003eSteps are from the Hygiena SuperSnap instructions for use. Set pass, caution and fail limits (RLU) for each test point in your luminometer software, based on your own sanitation program.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eCommon Applications\u003c\/h2\u003e\n\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eApplication\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eHow SuperSnap Helps\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003ePre-operational inspection\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eConfirms food-contact surfaces are clean before production starts.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eHigh-risk and RTE areas\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eHigher sensitivity supports tighter pass limits on critical surfaces.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSanitation verification\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eReagent resists acid and alkali sanitizer residues that can suppress results.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eTrend monitoring\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eResults can be logged and trended with Hygiena luminometer software.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSuperSnap® High Sensitivity Surface ATP Test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eItem number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eASY0222 (Hygiena reference SUS3000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003ePack\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e100 tests per box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eTest type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSurface ATP (cleaning verification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e4× more sensitive than UltraSnap (per Hygiena)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eSanitizer resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e5× more resistant to acid-based and 10× more resistant to alkali-based sanitizers (per Hygiena)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eRead time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eAbout 10 s (EnSURE Touch); 15 s (EnSURE, SystemSURE Plus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eCompatible instruments\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eAll Hygiena luminometers, including EnSURE Touch, EnSURE and SystemSURE Plus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eStorage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e2–8 °C (36–46 °F); up to 4 weeks at 20–25 °C before use; keep out of direct sunlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eShelf life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eUse by the expiry date on the label\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eUse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSingle use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eHygiena\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cem\u003eSpecifications are from the Hygiena SuperSnap product sheet, instructions for use and Hygiena product listing.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eSelection \u0026amp; Handling Notes\u003c\/h2\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#fff8e5;\"\u003e\n\u003cul style=\"margin:0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerate on receipt.\u003c\/strong\u003e Store at 2–8 °C. Devices can be kept at room temperature for up to 4 weeks before use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRead within 30 seconds\u003c\/strong\u003e of activating the device, or results may not be accurate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDon't swab visibly dirty surfaces.\u003c\/strong\u003e Heavy soil overloads the swab and inhibits the reaction. Clean first, then verify.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDon't touch the swab tip\u003c\/strong\u003e or the inside of the device. ATP from skin will raise the reading.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequires a luminometer.\u003c\/strong\u003e SuperSnap must be read in a Hygiena luminometer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle use only.\u003c\/strong\u003e See the Safety Data Sheet for handling and disposal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eProduct Documents\u003c\/h2\u003e\n\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hygiena.com\/documents\/62376\/supersnap-product-sheet-en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHygiena SuperSnap Product Sheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hygiena.com\/documents\/64071\/supersnap-instructions-en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHygiena SuperSnap Instructions for Use (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed the Safety Data Sheet or a certificate of analysis for a specific lot? \u003ca href=\"\/fr\/pages\/contact\"\u003eContact Cambridge\u003c\/a\u003e and we'll request it from Hygiena.\u003c\/p\u003e\n\n\u003ch2\u003eCanadian Purchasing Support\u003c\/h2\u003e\n\u003cp\u003eCambridge Environmental Products is a Canadian-owned laboratory supply distributor based in Ontario and has served Canadian labs since 1993. We supply Hygiena ATP tests with CAD pricing and shipping across Canada. We work with food and beverage processors, QA\/QC teams, sanitation managers, and research laboratories, and can help with quotes and standing orders. Browse our \u003ca href=\"\/fr\/collections\/lab-supplies\"\u003elab supplies\u003c\/a\u003e collection for more.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhat does SuperSnap measure?\u003c\/h3\u003e\n\u003cp\u003eIt measures ATP (adenosine triphosphate), which is found in food residue, microorganisms and other organic matter. The luminometer reports the result in relative light units (RLU). A higher reading means more residue on the surface.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHow is SuperSnap different from UltraSnap?\u003c\/h3\u003e\n\u003cp\u003eSuperSnap is Hygiena's high sensitivity surface test. Hygiena states it's 4 times more sensitive than UltraSnap and more resistant to sanitizer effects. It suits sites that need tighter pass limits.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhich luminometers does it work with?\u003c\/h3\u003e\n\u003cp\u003eAll Hygiena luminometers, including the EnSURE Touch, EnSURE and SystemSURE Plus. It isn't designed for other brands' luminometers.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHow should I store it?\u003c\/h3\u003e\n\u003cp\u003eRefrigerate at 2–8 °C. Devices can be kept at room temperature (20–25 °C) for up to 4 weeks before use. Let them reach room temperature before testing.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eDoes SuperSnap detect bacteria?\u003c\/h3\u003e\n\u003cp\u003eIt detects ATP from all organic sources, including bacteria, but it isn't a bacteria count. Use it to verify cleaning, and use microbiological testing to confirm specific organisms.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHow many tests are in a box?\u003c\/h3\u003e\n\u003cp\u003e100 single-use tests.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eIs SuperSnap available in Canada?\u003c\/h3\u003e\n\u003cp\u003eYes. Cambridge Environmental Products supplies Hygiena SuperSnap across Canada with CAD pricing.\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003ch3 style=\"font-size:18px; line-height:1.35; margin-top:0;\"\u003eNeed Help Setting Up ATP Testing?\u003c\/h3\u003e\n\u003cp\u003eTell us:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe luminometer you use\u003c\/li\u003e\n\u003cli\u003eThe surfaces and areas you test\u003c\/li\u003e\n\u003cli\u003eYour current pass\/fail limits\u003c\/li\u003e\n\u003cli\u003eHow many tests you use per month\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe'll help you choose the right Hygiena test and set up standing orders.\u003c\/p\u003e\n\u003ca href=\"\/fr\/pages\/contact\" style=\"display:inline-block; padding:12px 18px; background:#1f4e79; color:#ffffff; text-decoration:none; border-radius:5px; font-weight:bold;\"\u003e\nContact Cambridge for Product Support\n\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Hygiena","offers":[{"title":"Default Title","offer_id":50047687852291,"sku":"SUS3000","price":521.39,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/SuperSnap.webp?v=1793196481","url":"https:\/\/cambridgeenviro.com\/fr\/products\/hygiena-supersnap-high-sensitivity-atp-test","provider":"Cambridge Environmental Products, Inc.","version":"1.0","type":"link"}