{"product_id":"hygiena-microsnap-eb-enterobacteriaceae-test","title":"Hygiena MicroSnap™ EB – Rapid Enterobacteriaceae Test, Step 1 \u0026 Step 2","description":"\u003ch2\u003eHygiena MicroSnap™ EB – Rapid Enterobacteriaceae Test, Step 1 \u0026amp; Step 2\u003c\/h2\u003e\n\n\u003cp\u003eHygiena MicroSnap EB is a rapid test that detects and counts Enterobacteriaceae (EB) in food, liquids and on surfaces. EB are a widely used hygiene indicator group in food production. The test gives a CFU count in 6 or 7 hours, or a presence\/absence result after 8 hours, so you have results within the same shift. It uses a Step 1 enrichment device and a Step 2 detection device, read on the Hygiena EnSURE Touch.\u003c\/p\u003e\n\n\u003cp\u003eStep 1 and Step 2 devices are each sold in boxes of 100. Hygiena MicroSnap EB is available in Canada from Cambridge Environmental Products with CAD pricing and Canadian purchasing support.\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003ch3 style=\"font-size:18px; line-height:1.35; margin-top:0;\"\u003eIdeal For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFood processing\u003c\/strong\u003e: Enterobacteriaceae as a hygiene and process indicator\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental monitoring\u003c\/strong\u003e: EB on food-contact and non-food-contact surfaces\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDairy, infant formula, meat and ready-to-eat\u003c\/strong\u003e producers monitoring EB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSame-day decisions\u003c\/strong\u003e on product release or re-cleaning\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eWhy Choose MicroSnap EB?\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eSame-shift results\u003c\/h3\u003e\n\u003cp\u003eCounts are ready after 6 or 7 hours of enrichment, or presence\/absence after 8 hours, plus a 10-second read. Product can be held or released, or a surface re-cleaned, the same day instead of waiting 1 to 3 days for plate counts.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eCounts read automatically\u003c\/h3\u003e\n\u003cp\u003eThe Hygiena EnSURE Touch reads the detection device and converts the light signal to CFU, so there are no colonies to count by hand. Results are stored and can be trended in SureTrend.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eOne system for surfaces, liquids and solids\u003c\/h3\u003e\n\u003cp\u003eSwab a 10 × 10 cm surface directly with the enrichment device, or add 1 mL of a liquid or 10% food homogenate. Serial dilutions extend the counting range for heavily contaminated samples.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eCount or presence\/absence\u003c\/h3\u003e\n\u003cp\u003eRun 6 or 7 hours for a count, or 8 hours or more for a presence\/absence result. The EnSURE Touch reports 0 as absence, 1 as caution and 2 or more as presence.\u003c\/p\u003e\n\n\u003ch2\u003eHow MicroSnap Works: Two Steps\u003c\/h2\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003cp style=\"margin-top:0;\"\u003e\u003cstrong\u003eEach test uses one Step 1 device and one Step 2 device.\u003c\/strong\u003e Both are sold separately in boxes of 100, so for 100 tests, order one box of each.\u003c\/p\u003e\n\u003cul style=\"margin-bottom:0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 1 – Enrichment:\u003c\/strong\u003e a pre-moistened swab device with growth medium. Collect the sample, activate and incubate at 37 °C for 6 or 7 hours (count) or 8–24 hours (presence\/absence).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 2 – Detection:\u003c\/strong\u003e transfer 0.1 mL (2 drops) of the enriched sample into the detection device, activate and read on the EnSURE Touch.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eAvailable Devices\u003c\/h2\u003e\n\n\u003cp\u003eChoose the \u003cstrong\u003eDevice\u003c\/strong\u003e in the selector.\u003c\/p\u003e\n\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eCode\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eDevice\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eStep\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003ePack\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMS1-EB\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMicroSnap EB Enrichment Device\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eStep 1 – Enrichment\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMS2-EB\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMicroSnap EB Detection Device\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eStep 2 – Detection\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003col style=\"margin:0;\"\u003e\n\u003cli\u003eLet devices reach room temperature (20–25 °C) before use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample:\u003c\/strong\u003e swab a 10 × 10 cm (4 × 4 in) area in a crisscross pattern, or add 1 mL of liquid or 10% w\/v food homogenate to the enrichment device.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnrich:\u003c\/strong\u003e break the Snap-Valve, squeeze to release the medium, shake gently and incubate at 37 °C for 6 or 7 hours (count) or 8–24 hours (presence\/absence).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetect:\u003c\/strong\u003e transfer 0.1 mL (2 drops) of enriched sample to the detection device, break the Snap-Valve and squeeze to release the reagent, mix gently and read straight away.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRead:\u003c\/strong\u003e insert the detection device into the EnSURE Touch. Results display in CFU in about 10 seconds.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003eSteps are summarized from the Hygiena MicroSnap EB instructions for use. Follow the full instructions for timing, dilutions and controls.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eCounting Range\u003c\/h2\u003e\n\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eSample\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eApproximate Range\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSurface\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eFrom 10 CFU\/swab\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eLiquid (1 mL)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eFrom 10 CFU\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSolid (10% w\/v suspension)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eFrom 100 CFU\/g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003ePresence\/absence (8 h)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e0 = absence, 1 = caution, ≥2 = presence\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003cp\u003e\u003cem\u003eUpper limits depend on enrichment time (6 or 7 hours). See the Hygiena instructions for the full ranges, and dilute samples that exceed them.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eWhat You Need\u003c\/h2\u003e\n\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eItem\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMicroSnap Step 1 and Step 2 devices\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eFrom this page, one of each per test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eHygiena EnSURE Touch luminometer\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eRequired to read results (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eDry block incubator\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSet to 37 °C (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eFor food samples\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSample bags, homogenizer, sterile diluent and 1 mL pipette (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eTest\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eEnterobacteriaceae (EB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eCodes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMS1-EB (Step 1), MS2-EB (Step 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003ePack\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e100 devices per box, each step\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eEnrichment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e37 ± 0.5 °C; 6 or 7 h (count), 8–24 h (presence\/absence)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eDetection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eRead on EnSURE Touch in about 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eTime to result\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e6–8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eSamples\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSurfaces, liquids, solid food homogenates\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eStorage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e2–8 °C, protected from prolonged light\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eHygiena\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cem\u003eSpecifications are from the Hygiena MicroSnap EB instructions for use and product sheet.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eSelection \u0026amp; Handling Notes\u003c\/h2\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#fff8e5;\"\u003e\n\u003cul style=\"margin:0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder both steps.\u003c\/strong\u003e Step 1 and Step 2 devices are sold separately and both are needed for each test.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerate on receipt.\u003c\/strong\u003e Store devices at 2–8 °C, out of prolonged light, and use by the expiry date.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm samples and devices first.\u003c\/strong\u003e Cold samples under-detect. Bring samples and devices to 20–25 °C before testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKeep timing tight.\u003c\/strong\u003e Incubation time and temperature affect counts, so use a calibrated dry block incubator.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNot a Salmonella test.\u003c\/strong\u003e Hygiena notes EB counts can't substitute for Salmonella testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSome matrices need broth vials.\u003c\/strong\u003e Thick, dark or opaque samples can give low counts, and leafy greens can give high counts. Hygiena recommends its Enhanced EB Broth for difficult samples.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispose safely.\u003c\/strong\u003e Used devices may be biohazardous. Autoclave, or soak unsealed devices in 20% bleach for 1 hour, before disposal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFor food and environmental testing only.\u003c\/strong\u003e Not for diagnostic use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eProduct Documents\u003c\/h2\u003e\n\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hygiena.com\/documents\/63421\/microsnap-eb-enrichment--detection-device-instructions-en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHygiena MicroSnap EB Instructions for Use (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/hygiena.com\/documents\/62556\/microsnap-eb-product-sheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHygiena MicroSnap EB Product Sheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed the Safety Data Sheet or a certificate of analysis for a specific lot? \u003ca href=\"\/fr\/pages\/contact\"\u003eContact Cambridge\u003c\/a\u003e and we'll request it from Hygiena.\u003c\/p\u003e\n\n\u003ch2\u003eCanadian Purchasing Support\u003c\/h2\u003e\n\u003cp\u003eCambridge Environmental Products is a Canadian-owned laboratory supply distributor based in Ontario and has served Canadian labs since 1993. We supply Hygiena MicroSnap tests with CAD pricing and shipping across Canada. We work with food and beverage processors, QA\/QC labs, contract testing labs and research laboratories, and can help with quotes and standing orders. Browse our \u003ca href=\"\/fr\/collections\/lab-supplies\"\u003elab supplies\u003c\/a\u003e collection for more.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhat does MicroSnap EB detect?\u003c\/h3\u003e\n\u003cp\u003eEnterobacteriaceae, a family of bacteria used as a hygiene and process indicator in food production.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHow long does it take?\u003c\/h3\u003e\n\u003cp\u003e6 or 7 hours for a count, or 8 hours or more for presence\/absence, plus about 10 seconds to read.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eCan it replace Salmonella testing?\u003c\/h3\u003e\n\u003cp\u003eNo. Hygiena notes Enterobacteriaceae counts can't substitute for Salmonella testing.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eDo I need to buy both Step 1 and Step 2?\u003c\/h3\u003e\n\u003cp\u003eYes. Each test uses one enrichment device (Step 1) and one detection device (Step 2). They're sold separately in boxes of 100.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhat equipment do I need?\u003c\/h3\u003e\n\u003cp\u003eA Hygiena EnSURE Touch luminometer and a dry block incubator. Food samples also need sample bags, a homogenizer, diluent and a 1 mL pipette.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHow should I store MicroSnap devices?\u003c\/h3\u003e\n\u003cp\u003eRefrigerate at 2–8 °C, keep them out of prolonged light, and let them reach room temperature before use.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eAre MicroSnap tests available in Canada?\u003c\/h3\u003e\n\u003cp\u003eYes. Cambridge Environmental Products supplies Hygiena MicroSnap tests across Canada with CAD pricing.\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003ch3 style=\"font-size:18px; line-height:1.35; margin-top:0;\"\u003eNeed Help Setting Up MicroSnap Testing?\u003c\/h3\u003e\n\u003cp\u003eTell us:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWhat you test (surfaces, liquids, solid foods)\u003c\/li\u003e\n\u003cli\u003eWhich organisms your program monitors\u003c\/li\u003e\n\u003cli\u003eWhether you have an EnSURE Touch and dry block incubator\u003c\/li\u003e\n\u003cli\u003eHow many tests you run per week\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe'll help you choose the right MicroSnap tests and set up standing orders.\u003c\/p\u003e\n\u003ca href=\"\/fr\/pages\/contact\" style=\"display:inline-block; padding:12px 18px; background:#1f4e79; color:#ffffff; text-decoration:none; border-radius:5px; font-weight:bold;\"\u003e\nContact Cambridge for Product Support\n\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Hygiena","offers":[{"title":"Step 1","offer_id":50053069996291,"sku":"MS1-EB","price":283.39,"currency_code":"CAD","in_stock":true},{"title":"Step 2","offer_id":50053070029059,"sku":"MS2-EB","price":456.76,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/asy0361_microsnapebdetectionswab_1.png?v=1793212167","url":"https:\/\/cambridgeenviro.com\/fr\/products\/hygiena-microsnap-eb-enterobacteriaceae-test","provider":"Cambridge Environmental Products, Inc.","version":"1.0","type":"link"}