{"product_id":"burkle-stopcock-angled","title":"Burkle StopCock Angled Liquid Dispensing Tap","description":"\u003ch2\u003eBurkle StopCock Angled Liquid Dispensing Tap\u003c\/h2\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eBurkle StopCock angled\u003c\/strong\u003e is a polypropylene liquid dispensing tap designed for controlled dispensing from canisters, barrels, and other compatible containers with a \u003cstrong\u003eG 3\/4\" connection\u003c\/strong\u003e. Its angled, rotatable spout directs liquid toward the receiving container while the reduced nozzle helps dispense into narrow bottle openings.\u003c\/p\u003e\n\n\u003cp\u003eThe 0525-1000 StopCock uses a \u003cstrong\u003e3\/4\" internal-thread cap nut\u003c\/strong\u003e for connection to compatible containers and features a rotatable discharge spout designed to reduce residual dripping. The tapered outlet has a \u003cstrong\u003e6 mm outside diameter\u003c\/strong\u003e, making it useful when liquid needs to be directed into smaller openings.\u003c\/p\u003e\n\n\u003cp\u003eBurkle specifies media-contacting parts made from \u003cstrong\u003ePP, PE and PTFE\u003c\/strong\u003e. The StopCock is designed for laboratory, production, chemical logistics, food-related, and other compatible liquid-handling applications where convenient container dispensing is required.\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #D9D9D9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eIdeal For \/ Built For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDispensing liquids from laboratory canisters and barrels\u003c\/li\u003e\n\u003cli\u003eLiquid transfer in laboratories and research facilities\u003c\/li\u003e\n\u003cli\u003eFood and beverage production and compatible liquid-handling applications\u003c\/li\u003e\n\u003cli\u003eChemical logistics and container dispensing\u003c\/li\u003e\n\u003cli\u003eFilling bottles and containers with narrow openings\u003c\/li\u003e\n\u003cli\u003eApplications where the outlet needs to be rotated into a convenient dispensing position\u003c\/li\u003e\n\u003cli\u003eCompatible Burkle canisters and containers with G 3\/4\" connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eWhy Choose the Burkle StopCock Angled?\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eAngled, Rotatable Spout\u003c\/h3\u003e\n\n\u003cp\u003eThe angled outlet can be positioned to direct liquid where it is needed. Burkle specifically describes the rotatable spout as helping prevent unwanted dripping after dispensing, which can make liquid transfer cleaner and more controlled.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eReduced 6 mm Outlet\u003c\/h3\u003e\n\n\u003cp\u003eThe outlet has a \u003cstrong\u003e6 mm outside diameter\u003c\/strong\u003e and a reduced nozzle design. This is particularly useful when dispensing into bottles or other receiving containers with small openings, where a larger outlet could make positioning more difficult.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eG 3\/4\" Container Connection\u003c\/h3\u003e\n\n\u003cp\u003eThe StopCock connects to compatible containers using a \u003cstrong\u003eG 3\/4\" internal-thread cap nut\u003c\/strong\u003e. Burkle states that its StopCock discharge cocks fit containers with G 3\/4\" connection threads, while thread adapters can be used for connection to a wider range of compatible containers.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003ePP, PE and PTFE Media-Contacting Materials\u003c\/h3\u003e\n\n\u003cp\u003eBurkle specifies PP, PE and PTFE for the media-contacting components. Material compatibility should still be checked against the specific liquid being dispensed before use.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eConvenient Manual Dispensing\u003c\/h3\u003e\n\n\u003cp\u003eThe StopCock provides a simple way to dispense liquid directly from a storage container without transferring the entire container or using a separate dispensing vessel. This can be useful where containers are repeatedly accessed during laboratory or production workflows.\u003c\/p\u003e\n\n\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eStopCock angled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\u003cstrong\u003eBurkle part number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e0525-1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eAngled liquid dispensing tap \/ discharge cock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\u003cstrong\u003eInlet connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eG 3\/4\" internal thread, cap nut\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\u003cstrong\u003eOutlet type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eAngled discharge with spout\/nozzle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\u003cstrong\u003eSpout outside diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\u003cstrong\u003eNominal diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\u003cstrong\u003eMedia-contacting materials\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003ePP, PE and PTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\u003cstrong\u003eColour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e121 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e29 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e95 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\u003cstrong\u003ePackaging unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eBurkle's North American catalogue specifies that the StopCock design is pressure-resistant up to \u003cstrong\u003e2 bar at 20 °C\u003c\/strong\u003e under the manufacturer's stated test configuration, without the discharge bracket and grommet. This pressure specification should not be interpreted as a universal pressure rating for every installation or application.\u003c\/p\u003e\n\n\u003ch2\u003eCommon Applications\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eApplication\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eHow the StopCock Helps\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eLaboratory liquid dispensing\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eAllows liquids to be dispensed directly from compatible storage containers without transferring the entire container.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eFilling narrow-mouth bottles\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eThe reduced 6 mm spout helps direct liquid into smaller openings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eChemical logistics\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eProvides a convenient dispensing point for compatible liquids stored in containers and barrels.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eFood and beverage production\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eProvides manual liquid dispensing from compatible containers in production and handling workflows.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eResearch and production facilities\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eProvides repeatable access to liquids stored in compatible containers without requiring a separate dispensing assembly.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCompatible Accessories\u003c\/h2\u003e\n\n\u003cp\u003eBurkle offers several accessories for the StopCock system. These can extend the outlet configuration or allow liquid to be directed through tubing.\u003c\/p\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eAccessory\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eBurkle Part Number\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eHose nozzle, 4 mm\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e0525-1304\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eConnects compatible tubing to the StopCock.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eHose nozzle, 6 mm\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e0525-1306\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eConnects compatible tubing to the StopCock.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eHose nozzle, 8 mm\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e0525-1308\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eConnects compatible tubing to the StopCock.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eHose nozzle, 10 mm\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e0525-1310\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eConnects compatible tubing to the StopCock.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eHose nozzle, 12 mm\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e0525-1312\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eConnects compatible tubing to the StopCock.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eHose nozzle, 16 mm\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e0525-1316\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eConnects compatible tubing to the StopCock.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eDischarge angle\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e0525-1400\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eAngled adapter for directing the StopCock outlet.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCompatible Containers and Connections\u003c\/h2\u003e\n\n\u003cp\u003eThe StopCock is designed around a \u003cstrong\u003eG 3\/4\" container connection\u003c\/strong\u003e. Burkle states that its StopCock discharge cocks fit containers with G 3\/4\" connection threads, while thread adapters can extend compatibility to additional containers.\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #D9D9D9; padding:18px; margin:24px 0; border-radius:8px; background:#fff8e5;\"\u003e\n\u003cp\u003e\u003cstrong\u003eCheck the container connection before ordering.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe 0525-1000 uses a \u003cstrong\u003eG 3\/4\" internal-thread cap nut\u003c\/strong\u003e. Confirm that your container or adapter provides the appropriate mating G 3\/4\" connection.\u003c\/p\u003e\n\n\u003cp\u003eDo not select the product based only on the apparent physical size of the fitting. G-thread connections are standardized pipe-thread designations, and the connection type must match the mating component.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eUse \/ Handling Notes\u003c\/h2\u003e\n\n\u003cp\u003e\u003cstrong\u003eNot suitable for crystallizing substances.\u003c\/strong\u003e Burkle specifically identifies this limitation for the StopCock range.\u003c\/p\u003e\n\n\u003cp\u003eVerify chemical compatibility between the liquid and the media-contacting PP, PE and PTFE materials before use. Burkle provides a chemical-resistance resource for evaluating compatibility with specific substances.\u003c\/p\u003e\n\n\u003cp\u003eFor pressurized systems, remain within the manufacturer's specified operating conditions. Burkle's catalogue states a pressure resistance of up to 2 bar at 20 °C under the stated configuration; this should not be treated as a general pressure rating for every installation.\u003c\/p\u003e\n\n\u003ch2\u003eCanadian Purchasing Support\u003c\/h2\u003e\n\n\u003cp\u003eCambridge Environmental Products supplies laboratory equipment and fluid-handling products to Canadian laboratories, universities and colleges, food and beverage manufacturers, breweries, wastewater and environmental laboratories, research facilities, and industrial QA\/QC operations.\u003c\/p\u003e\n\n\u003cp\u003eThe Burkle StopCock angled is available in Canada with \u003cstrong\u003eCAD pricing and Canadian purchasing support\u003c\/strong\u003e. If you are unsure whether your canister, barrel, or container has the correct connection, provide Cambridge with the container model or a photo of the connection and we can help identify the appropriate fitting.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhat is the Burkle StopCock angled used for?\u003c\/h3\u003e\n\n\u003cp\u003eThe Burkle StopCock angled is a liquid dispensing tap designed to dispense liquids from compatible canisters, barrels, and other containers. Its angled outlet helps direct liquid into the receiving container.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhat is the Burkle part number?\u003c\/h3\u003e\n\n\u003cp\u003eThe Burkle part number for the StopCock angled is \u003cstrong\u003e0525-1000\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhat thread size does the StopCock angled use?\u003c\/h3\u003e\n\n\u003cp\u003eThe inlet connection uses a \u003cstrong\u003eG 3\/4\" internal-thread cap nut\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhat is the diameter of the dispensing spout?\u003c\/h3\u003e\n\n\u003cp\u003eThe Burkle specification lists an outside spout diameter of \u003cstrong\u003e6 mm\u003c\/strong\u003e. The nominal diameter is specified as 5 mm.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eCan the outlet be rotated?\u003c\/h3\u003e\n\n\u003cp\u003eYes. The StopCock angled has a rotatable spout that allows the discharge direction to be positioned as needed. Burkle states that the rotatable spout angle also helps prevent dripping.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhat materials contact the liquid?\u003c\/h3\u003e\n\n\u003cp\u003eBurkle specifies PP, PE and PTFE for the media-contacting parts.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eCan it be used with narrow-mouth bottles?\u003c\/h3\u003e\n\n\u003cp\u003eYes. Burkle specifically describes the reduced spout as suitable for bottles with narrow openings. The tapered outlet is designed to direct liquid through smaller openings.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eCan the StopCock connect to other container sizes?\u003c\/h3\u003e\n\n\u003cp\u003eThe StopCock is designed around a G 3\/4\" connection. Burkle states that thread adapters can be used to connect StopCock discharge cocks to a wider range of compatible containers.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eIs the StopCock suitable for chemicals?\u003c\/h3\u003e\n\n\u003cp\u003eThe media-contacting materials are PP, PE and PTFE, but suitability depends on the specific chemical. Check chemical compatibility before use rather than assuming the valve is compatible with every chemical.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eIs the StopCock suitable for crystallizing substances?\u003c\/h3\u003e\n\n\u003cp\u003eNo. Burkle specifically states that the StopCock is \u003cstrong\u003enot suitable for crystallizing substances\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eIs the Burkle StopCock available in Canada?\u003c\/h3\u003e\n\n\u003cp\u003eCambridge Environmental Products supplies Burkle products to Canadian customers. Contact us for current CAD pricing, availability, and Canadian purchasing support.\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #D9D9D9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003ch2\u003eNeed Help Choosing the Right Dispensing Tap?\u003c\/h2\u003e\n\n\u003cp\u003eIf you are unsure whether the Burkle StopCock angled is compatible with your container, send Cambridge the container model, connection\/thread specification, or a photo of the outlet. We can help identify the appropriate StopCock or adapter for your application.\u003c\/p\u003e\n\n\u003ca href=\"\/fr\/pages\/contact\" style=\"display:inline-block; padding:12px 18px; background:#1f4e79; color:#ffffff; text-decoration:none; border-radius:5px; font-weight:bold;\"\u003eContact Cambridge for Product Support\u003c\/a\u003e\n\n\u003c\/div\u003e\n","brand":"Burkle","offers":[{"title":"Default Title","offer_id":49688702255363,"sku":"0525-1000","price":59.36,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/0525-1000_stopcock_funktion_freigestellt.png?v=1790180264","url":"https:\/\/cambridgeenviro.com\/fr\/products\/burkle-stopcock-angled","provider":"Cambridge Environmental Products, Inc.","version":"1.0","type":"link"}