{"title":"Raven Environmental Products","description":"\u003ch3\u003e\u003cstrong\u003eCambridge × Raven: Built for Wastewater Operators\u003cbr\u003e\u003cbr\u003eWe’re proud to partner with \u003cstrong data-start=\"385\" data-end=\"417\"\u003eRaven Environmental Products\u003c\/strong\u003e—a U.S. manufacturer known for durable, operator-friendly instruments used in \u003cstrong data-start=\"495\" data-end=\"545\"\u003ewastewater and water treatment process control\u003c\/strong\u003e.\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"586\" data-end=\"768\"\u003e\u003cstrong data-start=\"586\" data-end=\"768\"\u003eCambridge Environmental Products is now working with Raven Environmental Products as a trusted partner to better serve wastewater and water treatment professionals across Canada.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"770\" data-end=\"1327\"\u003eRaven is widely recognized for practical, field-proven tools that support \u003cstrong data-start=\"844\" data-end=\"880\"\u003eactivated sludge process control\u003c\/strong\u003e and day-to-day plant decision-making. The foundation of Raven’s instrument line traces back to control tests developed in the \u003cstrong data-start=\"1007\" data-end=\"1016\"\u003e1970s\u003c\/strong\u003e by \u003cstrong data-start=\"1020\" data-end=\"1038\"\u003eAlfred W. West\u003c\/strong\u003e, then Chief Engineer in the U.S. EPA’s Waste Treatment Branch. Those methods became long-standing standards in plant operations, and in \u003cstrong data-start=\"1175\" data-end=\"1183\"\u003e1983\u003c\/strong\u003e, Raven was established to manufacture the instruments required to carry out these tests—built to be \u003cstrong data-start=\"1284\" data-end=\"1326\"\u003edurable, simple to use, and affordable\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1329\" data-end=\"1524\"\u003eToday, Raven remains \u003cstrong data-start=\"1350\" data-end=\"1368\"\u003eprivately held\u003c\/strong\u003e, with \u003cstrong data-start=\"1375\" data-end=\"1429\"\u003ein-house engineering, testing, and quality control\u003c\/strong\u003e, continuing to design and manufacture instruments that wastewater operators rely on worldwide.\u003c\/p\u003e\n\u003ch3 data-start=\"1526\" data-end=\"1546\"\u003eWhere Raven Fits\u003c\/h3\u003e\n\u003cp data-start=\"1547\" data-end=\"1581\"\u003eRaven instruments are used across:\u003c\/p\u003e\n\u003cul data-start=\"1582\" data-end=\"1745\"\u003e\n\u003cli data-start=\"1582\" data-end=\"1643\"\u003e\n\u003cp data-start=\"1584\" data-end=\"1643\"\u003e\u003cstrong data-start=\"1584\" data-end=\"1608\"\u003eWastewater treatment\u003c\/strong\u003e (activated sludge process control)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1644\" data-end=\"1677\"\u003e\n\u003cp data-start=\"1646\" data-end=\"1677\"\u003e\u003cstrong data-start=\"1646\" data-end=\"1677\"\u003ePotable water filter plants\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1678\" data-end=\"1699\"\u003e\n\u003cp data-start=\"1680\" data-end=\"1699\"\u003e\u003cstrong data-start=\"1680\" data-end=\"1699\"\u003eFood \u0026amp; beverage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1700\" data-end=\"1718\"\u003e\n\u003cp data-start=\"1702\" data-end=\"1718\"\u003e\u003cstrong data-start=\"1702\" data-end=\"1718\"\u003ePulp \u0026amp; paper\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1719\" data-end=\"1745\"\u003e\n\u003cp data-start=\"1721\" data-end=\"1745\"\u003e\u003cstrong data-start=\"1721\" data-end=\"1745\"\u003ePetroleum and mining\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1747\" data-end=\"1781\"\u003eMade in the USA, Built to Work\u003c\/h3\u003e\n\u003cp data-start=\"1782\" data-end=\"2111\"\u003eRaven manufactures its products and electronic circuits in the \u003cstrong data-start=\"1845\" data-end=\"1862\"\u003eUnited States\u003c\/strong\u003e, using modern production methods including \u003cstrong data-start=\"1906\" data-end=\"1945\"\u003eCNC machining, 3D printing, CAD\/CAM\u003c\/strong\u003e, and disciplined internal QC. Customers also benefit from direct, practical feedback loops—real access to product engineers for enhancements and application insight.\u003c\/p\u003e\n\u003ch3 data-start=\"2113\" data-end=\"2142\"\u003eWhy Buy Through Cambridge\u003c\/h3\u003e\n\u003cp data-start=\"2143\" data-end=\"2192\"\u003eWhen you source Raven through Cambridge, you get:\u003c\/p\u003e\n\u003cul data-start=\"2193\" data-end=\"2364\"\u003e\n\u003cli data-start=\"2193\" data-end=\"2234\"\u003e\n\u003cp data-start=\"2195\" data-end=\"2234\"\u003eCanadian support and responsive quoting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2235\" data-end=\"2306\"\u003e\n\u003cp data-start=\"2237\" data-end=\"2306\"\u003eHelp selecting the right instrument for your process control workflow\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2307\" data-end=\"2364\"\u003e\n\u003cp data-start=\"2309\" data-end=\"2364\"\u003eCoordination on logistics, documentation, and follow-up\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2366\" data-end=\"2493\"\u003e\u003cstrong data-start=\"2366\" data-end=\"2493\"\u003eBrowse Raven products below. If you’re unsure what fits your application, contact us we’ll point you to the right solution.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/h3\u003e","products":[{"product_id":"raven-filter-media-manager","title":"Filter Media Manager - Raven Environmental Products","description":"\u003cp style=\"text-align: center;\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eFilter Media Manager - Raven Environmental Products\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Filter Media Manager from Raven Environmental Products \u003c\/strong\u003eoffers an affordable solution for measuring filter bed expansion during backwash. \u003cstrong\u003e\u003c\/strong\u003eProper filter bed expansion during backwash is essential for maintaining filter performance and extending equipment life. The EPA recommends 20-25% expansion to effectively clean filter media like anthracite and sand. Insufficient expansion allows \"mud balls\" to form, compromising the filter's ability to remove harmful microorganisms including \u003cem\u003eCryptosporidium\u003c\/em\u003e oocysts and \u003cem\u003eGiardia\u003c\/em\u003e cysts. Raven's portable Media Expansion Measurement System provides an affordable, accessible alternative to costly fixed equipment, making accurate bed expansion monitoring practical for water treatment facilities of any scale. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAvailable with round or square railing clamp\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e25 foot (7.6m) standard cable length \u003c\/li\u003e\n\u003cli\u003eCustom cable lengths available \u003c\/li\u003e\n\u003cli\u003e1 year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHow to Use:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e1) Lower the sensor to rest on the  compacted media bed prior to backwash.\u003c\/p\u003e\n\u003cp\u003e2) Press Zero on the controller to set the counter to 0.\u003c\/p\u003e\n\u003cp\u003e3) As dirt and debris is evacuated, the red light will illuminate.\u003c\/p\u003e\n\u003cp\u003e4) When the backflow water becomes clear, the media will begin to rise with expansion.\u003c\/p\u003e\n\u003cp\u003e5) Raise the sensor just until the red light goes out. Repeat until the bed finishes expanding. Note the amount of expansion on the display.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ciframe width=\"1412\" height=\"794\" src=\"https:\/\/www.youtube.com\/embed\/6CcufF9bx1Y\" title=\"Filter Media Manager\"\u003e\u003c\/iframe\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Cambridge Environmental Products, Inc.","offers":[{"title":"Default Title \/ S-60100-S - Square Clamp","offer_id":47658700046595,"sku":"S-60100-S","price":3850.75,"currency_code":"CAD","in_stock":false},{"title":"Default Title \/ S-60100-R - Round Clamp","offer_id":47658700112131,"sku":"S-60100-R","price":3850.75,"currency_code":"CAD","in_stock":false},{"title":"Default Title (Wholesale) \/ S-60100-S - Square Clamp","offer_id":47668101742851,"sku":null,"price":3850.75,"currency_code":"CAD","in_stock":false},{"title":"Default Title (Wholesale) \/ S-60100-R - Round Clamp","offer_id":47668101775619,"sku":null,"price":3850.75,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/PrimaryS-60100.png?v=1769097902"},{"product_id":"sid-rotary-portable-sludge-interface-detector-raven-environmental-products","title":"SID Rotary Portable Sludge Interface Detector - Raven Environmental Products","description":"\u003cp style=\"text-align: center;\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eSID Rotary Portable Sludge Interface Detector - Raven Environmental Products\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe SID Rotary Portable Sludge Interface Detector from Raven Environmental Products\u003c\/strong\u003e features a digital controller with a backlit display for improved night time visibility. Its intuitive design lets operators simply release the probe and retrieve it like a fishing reel, eliminating contact with wet surfaces. The digital counter provides sludge elevation readings in inches or centimetres, while the rail-mounted base ensures measurement consistency. The unit is built is for durability, with a stainless steel infrared sensor and protective 4-point aluminium roll cage, but still lightweight and compact to allow servicing multiple tanks. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBase Stations and Free-Style Handle Sold Separately\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLightweight and portable\u003c\/li\u003e\n\u003cli\u003eSimple and sanitary operation\u003c\/li\u003e\n\u003cli\u003eAccurate and repeatable measurements\u003c\/li\u003e\n\u003cli\u003eBase station and handle options available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBase Stations:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBase stations are integral for efficient use of the SID Rotary Sludge Interface Detector. They are mounted at each tank, providing a fixed sampling point for sludge level measurement. The SID Rotary is mounted by simply sliding it under the base station claws, with an additional tether provided for extra security. Base stations are sold separately, with Universal, L-Rail, T-Rail, and Round Rail options available. Base stations include stainless steel and aluminum mounting hardware.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFree-Style Handle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ergonomic free-style handle allows use of the SID Rotary Portable Sludge Interface Detector in tanks without railings for base station mounting. Pressing the thumb lever releases the brake, allowing the sensor to be lowered into the tank. Free-style handle is sold separately.\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Literature: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" title=\"SID Rotary Portable Sludge Interface Detector Brochure\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/SID_Rotary_Sales_Literature.pdf?v=1769189994\" target=\"_blank\"\u003eSID Rotary Portable Sludge Interface Detector - Brochure\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" title=\"SID Rotary Portable Sludge Interface Detector - Raven Environmental Products\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/SID_Rotary_S-40100_User_Guide.pdf?v=1770304960\" target=\"_blank\"\u003eSID Rotary Portable Sludge Interface Detector - User Guide\u003c\/a\u003e\u003c\/p\u003e","brand":"Cambridge Environmental Products, Inc.","offers":[{"title":"Default Title \/ S-40100-30 - Sludge Interface Detector w\/ 30ft (9.1m) Cable","offer_id":47671246553347,"sku":"S-40100-30","price":2904.67,"currency_code":"CAD","in_stock":true},{"title":"Default Title \/ S-40100-50 - Sludge Interface Detector w\/ 50ft (15.2m) Cable","offer_id":47671511482627,"sku":"S-40100-50","price":2999.73,"currency_code":"CAD","in_stock":true},{"title":"Default Title \/ S-40-163 - Universal Base Station w\/ mounting hardware","offer_id":47713908392195,"sku":"S-40-163","price":201.3,"currency_code":"CAD","in_stock":true},{"title":"Default Title \/ S-40-160 - L-Rail Base Station w\/ mounting hardware","offer_id":47713908424963,"sku":"S-40-160","price":217.39,"currency_code":"CAD","in_stock":true},{"title":"Default Title \/ S-40-161 - T-Rail Base Station w\/ mounting hardware","offer_id":47713908457731,"sku":"S-40-161","price":221.15,"currency_code":"CAD","in_stock":true},{"title":"Default Title \/ S-40-162 - Round Rail Base Station w\/ mounting hardware","offer_id":47713908490499,"sku":"S-40-162","price":236.51,"currency_code":"CAD","in_stock":true},{"title":"Default Title \/ S-40-170 - Free-Style Handle","offer_id":47713908523267,"sku":"S-40-170","price":237.19,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale) \/ S-40100-30 - Sludge Interface Detector w\/ 30ft (9.1m) Cable","offer_id":47671246618883,"sku":"S-40100-30","price":2323.73,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale) \/ S-40100-50 - Sludge Interface Detector w\/ 50ft (15.2m) Cable","offer_id":47671511515395,"sku":"S-40100-50","price":2399.79,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale) \/ S-40-163 - Universal Base Station w\/ mounting hardware","offer_id":47713908556035,"sku":"S-40-163","price":161.04,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale) \/ S-40-160 - L-Rail Base Station w\/ mounting hardware","offer_id":47713908588803,"sku":"S-40-160","price":173.91,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale) \/ S-40-161 - T-Rail Base Station w\/ mounting hardware","offer_id":47713908621571,"sku":"S-40-161","price":176.92,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale) \/ S-40-162 - Round Rail Base Station w\/ mounting hardware","offer_id":47713908654339,"sku":"S-40-162","price":189.21,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale) \/ S-40-170 - Free-Style Handle","offer_id":47713908687107,"sku":"S-40-170","price":189.75,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/PrimaryS-40100.png?v=1769194653"},{"product_id":"f-10300-process-centrifuge","title":"F-10300 Process Centrifuge","description":"\u003cp style=\"text-align: center;\" data-end=\"207\" data-start=\"185\"\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eF-10300 Process Centrifuge\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-end=\"529\" data-start=\"209\"\u003e\u003cstrong data-end=\"245\" data-start=\"209\"\u003eRaven F-10300 Process Centrifuge\u003c\/strong\u003e is a proven, industrial-grade solution for quickly determining percent solids in liquid samples. Trusted by process engineers since 1983, the F-10300 delivers reliable, repeatable results in as little as\u003cstrong\u003e \u003c\/strong\u003e15 minutes, helping operators make informed, proactive process adjustments.\u003c\/p\u003e\n\u003cp data-end=\"908\" data-start=\"531\"\u003eDesigned specifically for applications such as wastewater treatment, industrial pre-treatment, food and beverage processing, mining, fluid reclamation, and machining fluids, the F-10300 features a 3000 RPM horizontal swing-out rotor that creates a clean, straight-line interface between compacted solids and supernatant; essential for accurate solids volume measurement.\u003c\/p\u003e\n\u003cp data-end=\"1328\" data-start=\"910\"\u003eOperation is simple: load the samples, set the timer, and start. The digital countdown timer with audible end-of-cycle alert ensures consistent spin times, while dedicated controls (including a one-touch 15-minute wastewater spin) streamline routine testing. Built with a stainless steel structure and precision aluminum components, the F-10300 operates smoothly and quietly in demanding industrial environments.\u003c\/p\u003e\n\u003cp data-end=\"1525\" data-start=\"1330\"\u003eThe centrifuge comes with six reusable polycarbonate centrifuge tubes with high-visibility graduations from 0.20% to 100%, allowing direct solids percentage readings without calculations.\u003c\/p\u003e\n\u003cp data-end=\"1525\" data-start=\"1330\"\u003e\u003cbr\u003e\u003cstrong data-start=\"256\" data-end=\"307\"\u003eRaven B-10101-19 Polycarbonate Centrifuge Tubes\u003c\/strong\u003e are durable, reusable tubes designed for precise solids measurement in industrial samples. Featuring a conical bottom and a clearly marked graduated scale from 0.2% to 100%, these tubes make it easy to quantify even very small amounts of compacted solids.\u003c\/p\u003e\n\u003cp data-start=\"571\" data-end=\"862\"\u003eSpecifically designed to fit directly in the trunnion rings of Raven’s F-10300 Process Centrifuge, the tubes hang securely in place during high-speed spins. Constructed from high-strength polycarbonate, they are built to withstand repeated use in demanding industrial environments.\u003c\/p\u003e\n\u003cblockquote data-start=\"864\" data-end=\"957\"\u003e\n\u003cp data-start=\"866\" data-end=\"957\"\u003e\u003cstrong data-start=\"866\" data-end=\"880\"\u003eImportant:\u003c\/strong\u003e These tubes \u003cstrong data-start=\"893\" data-end=\"954\"\u003ecannot be used with flammables, solvents, or cooking oils\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cp data-start=\"959\" data-end=\"1056\"\u003eSold in packs of \u003cstrong data-start=\"976\" data-end=\"988\"\u003e12 tubes\u003c\/strong\u003e, making them ideal for routine testing or keeping spares on hand.\u003c\/p\u003e\n\u003chr data-end=\"1651\" data-start=\"1648\"\u003e\n\u003cp data-end=\"1679\" data-start=\"1653\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"2785\" data-start=\"1681\"\u003e\n\u003cli data-end=\"1769\" data-start=\"1681\"\u003e\n\u003cp data-end=\"1769\" data-start=\"1683\"\u003e\u003cstrong data-end=\"1707\" data-start=\"1683\"\u003eFast solids analysis\u003c\/strong\u003e – Determine percent solids by volume in just \u003cstrong data-end=\"1767\" data-start=\"1753\"\u003e15 minutes\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1883\" data-start=\"1770\"\u003e\n\u003cp data-end=\"1883\" data-start=\"1772\"\u003e\u003cstrong data-end=\"1811\" data-start=\"1772\"\u003e3000 RPM horizontal swing-out rotor\u003c\/strong\u003e – Ensures a straight solids-to-liquid interface for accurate readings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1967\" data-start=\"1884\"\u003e\n\u003cp data-end=\"1967\" data-start=\"1886\"\u003e\u003cstrong data-end=\"1907\" data-start=\"1886\"\u003eSix-tube capacity\u003c\/strong\u003e – Efficient batch sampling for routine process monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2099\" data-start=\"1968\"\u003e\n\u003cp data-end=\"2099\" data-start=\"1970\"\u003e\u003cstrong data-end=\"1999\" data-start=\"1970\"\u003eIndustrial-focused design\u003c\/strong\u003e – Ideal for wastewater, industrial pre-treatment, food \u0026amp; beverage, mining, and fluids reclamation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2197\" data-start=\"2100\"\u003e\n\u003cp data-end=\"2197\" data-start=\"2102\"\u003e\u003cstrong data-end=\"2127\" data-start=\"2102\"\u003eDigital control panel\u003c\/strong\u003e – LCD display with countdown timer and audible cycle-complete alert\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2311\" data-start=\"2198\"\u003e\n\u003cp data-end=\"2311\" data-start=\"2200\"\u003e\u003cstrong data-end=\"2233\" data-start=\"2200\"\u003eWastewater-optimized controls\u003c\/strong\u003e – Dedicated 15-minute speed key plus one-minute increment\/decrement buttons\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2435\" data-start=\"2312\"\u003e\n\u003cp data-end=\"2435\" data-start=\"2314\"\u003e\u003cstrong data-end=\"2351\" data-start=\"2314\"\u003eReusable graduated tubes included\u003c\/strong\u003e – Six polycarbonate tubes with conical bottoms, clearly marked from 0.20% to 100%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2520\" data-start=\"2436\"\u003e\n\u003cp data-end=\"2520\" data-start=\"2438\"\u003e\u003cstrong data-end=\"2465\" data-start=\"2438\"\u003eSmooth, quiet operation\u003c\/strong\u003e – Precision-balanced rotor and enclosed motor design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2600\" data-start=\"2521\"\u003e\n\u003cp data-end=\"2600\" data-start=\"2523\"\u003e\u003cstrong data-end=\"2547\" data-start=\"2523\"\u003eDurable construction\u003c\/strong\u003e – Stainless steel housing with aluminum components\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2683\" data-start=\"2601\"\u003e\n\u003cp data-end=\"2683\" data-start=\"2603\"\u003e\u003cstrong data-end=\"2617\" data-start=\"2603\"\u003eTEFC motor\u003c\/strong\u003e – Totally enclosed, fan-cooled motor for industrial reliability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2763\" data-start=\"2684\"\u003e\n\u003cp data-end=\"2763\" data-start=\"2686\"\u003e\u003cstrong data-end=\"2707\" data-start=\"2686\"\u003eCompact footprint\u003c\/strong\u003e – Bench-friendly size without sacrificing performance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2785\" data-start=\"2764\"\u003e\n\u003cp data-end=\"2785\" data-start=\"2766\"\u003e\u003cstrong data-end=\"2785\" data-start=\"2766\"\u003e1-year warranty\u003c\/strong\u003e\u003cstrong data-end=\"2785\" data-start=\"2766\"\u003e\u003c\/strong\u003e\u003cstrong data-end=\"2785\" data-start=\"2766\"\u003e\u003c\/strong\u003e\u003cstrong data-end=\"2785\" data-start=\"2766\"\u003e\u003c\/strong\u003e\u003cstrong data-end=\"2785\" data-start=\"2766\"\u003e\u003c\/strong\u003e\u003cstrong data-end=\"2785\" data-start=\"2766\"\u003e\u003c\/strong\u003e\u003cstrong data-end=\"2785\" data-start=\"2766\"\u003e\u003c\/strong\u003e\u003cstrong data-end=\"2785\" data-start=\"2766\"\u003e\u003c\/strong\u003e\u003cstrong data-end=\"2785\" data-start=\"2766\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2785\" data-start=\"2766\"\u003e \u003c\/p\u003e\n\u003cp data-end=\"2785\" data-start=\"2766\"\u003e\u003cstrong data-end=\"2785\" data-start=\"2766\"\u003e\u003c\/strong\u003e\u003cstrong\u003eDocumentation\u003c\/strong\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/Focus_Centrifuge_F-10300.pdf?v=1769454318\"\u003eBrochure\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/Waste_Water_Application_F-10300.pdf?v=1769454326\"\u003eWaste Water Application\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/TBbLi_QAefw?si=Z7gXVgz0FshCuKg7\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp data-end=\"205\" data-start=\"164\"\u003eFAQ — Raven F-10300 Process Centrifuge\u003c\/p\u003e\n\u003cp data-end=\"254\" data-start=\"207\"\u003e1) What is the F-10300 designed to measure?\u003c\/p\u003e\n\u003cp data-end=\"540\" data-start=\"255\"\u003eThe F-10300 is designed for \u003cstrong data-end=\"319\" data-start=\"283\"\u003erapid percent solids (by volume)\u003c\/strong\u003e testing in liquid samples using the graduated Raven polycarbonate tubes, typically as a \u003cstrong data-end=\"427\" data-start=\"408\"\u003eprocess-control\u003c\/strong\u003e tool for wastewater, industrial pretreatment, and other industrial fluids. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"589\" data-start=\"542\"\u003e2) Is this the same as MLSS (mg\/L) testing?\u003c\/p\u003e\n\u003cp data-end=\"949\" data-start=\"590\"\u003eNot exactly. The centrifuge tube provides a \u003cstrong data-end=\"669\" data-start=\"634\"\u003ecompacted solids volume reading\u003c\/strong\u003e (a “percent solids by volume” style result). MLSS is typically reported as \u003cstrong data-end=\"753\" data-start=\"745\"\u003emg\/L\u003c\/strong\u003e using a gravimetric lab method. Operators often use the centrifuge for fast trending, then \u003cstrong data-end=\"858\" data-start=\"845\"\u003ecorrelate\u003c\/strong\u003e it to lab MLSS values if they need mg\/L equivalents. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"1010\" data-start=\"951\"\u003e3) Can I convert the centrifuge reading to MLSS (mg\/L)?\u003c\/p\u003e\n\u003cp data-end=\"1319\" data-start=\"1011\"\u003eYes—\u003cstrong data-end=\"1059\" data-start=\"1015\"\u003eif you build a site-specific correlation\u003c\/strong\u003e. A common approach is to run the centrifuge test and send the same samples for lab MLSS (or run the Standard Methods gravimetric test), then graph results to create a conversion curve for your plant and sludge conditions. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"1349\" data-start=\"1321\"\u003e4) How fast is the test?\u003c\/p\u003e\n\u003cp data-end=\"1624\" data-start=\"1350\"\u003eThe unit is built around fast decision-making: typical wastewater spins are \u003cstrong data-end=\"1454\" data-start=\"1426\"\u003eas little as ~15 minutes\u003c\/strong\u003e, and the control panel includes a \u003cstrong data-end=\"1527\" data-start=\"1489\"\u003ededicated 15-minute wastewater key\u003c\/strong\u003e plus 1-minute increment\/decrement buttons for consistency. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"1668\" data-start=\"1626\"\u003e5) How many samples can I run at once?\u003c\/p\u003e\n\u003cp data-end=\"1805\" data-start=\"1669\"\u003eThe rotor is a \u003cstrong data-end=\"1728\" data-start=\"1684\"\u003esix-position horizontal swing-out design\u003c\/strong\u003e, allowing up to \u003cstrong data-end=\"1766\" data-start=\"1745\"\u003esix tubes per run\u003c\/strong\u003e. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"1861\" data-start=\"1807\"\u003e6) Why does the horizontal swing-out rotor matter?\u003c\/p\u003e\n\u003cp data-end=\"2090\" data-start=\"1862\"\u003eA horizontal swing-out rotor produces a \u003cstrong data-end=\"1936\" data-start=\"1902\"\u003eclean, straight-line interface\u003c\/strong\u003e between compacted solids and the supernatant—this is the whole point for readable percent-solids-by-volume results. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"2153\" data-start=\"2092\"\u003e7) What tubes does it use, and what is the reading range?\u003c\/p\u003e\n\u003cp data-end=\"2392\" data-start=\"2154\"\u003eIt uses Raven’s reusable \u003cstrong data-end=\"2210\" data-start=\"2179\"\u003epolycarbonate conical tubes\u003c\/strong\u003e with high-visibility graduations from \u003cstrong data-end=\"2266\" data-start=\"2249\"\u003e0.20% to 100%\u003c\/strong\u003e, enabling direct readings without calculations. The tube volume is listed as \u003cstrong data-end=\"2353\" data-start=\"2344\"\u003e11 mL\u003c\/strong\u003e. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"2437\" data-start=\"2394\"\u003e8) What’s included with the centrifuge?\u003c\/p\u003e\n\u003cp data-end=\"2590\" data-start=\"2438\"\u003eThe centrifuge is supplied with \u003cstrong data-end=\"2523\" data-start=\"2470\"\u003esix reusable Raven polycarbonate centrifuge tubes\u003c\/strong\u003e for percent-solids readings. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"2637\" data-start=\"2592\"\u003e9) Are extra\/replacement tubes available?\u003c\/p\u003e\n\u003cp data-end=\"2752\" data-start=\"2638\"\u003eYes—replacement tubes are available as \u003cstrong data-end=\"2697\" data-start=\"2677\"\u003eRaven B-10101-19\u003c\/strong\u003e (sold in packs). \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"2820\" data-start=\"2754\"\u003e10) Are there sample limitations (chemicals I should not use)?\u003c\/p\u003e\n\u003cp data-end=\"3039\" data-start=\"2821\"\u003eYes. The Raven polycarbonate tubes are \u003cstrong data-end=\"2909\" data-start=\"2860\"\u003enot for flammables, solvents, or cooking oils\u003c\/strong\u003e. If your sample stream includes incompatible chemicals, you should use an alternate method. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"3096\" data-start=\"3041\"\u003e11) What are the key performance specs (speed\/RCF)?\u003c\/p\u003e\n\u003cp data-end=\"3209\" data-start=\"3097\"\u003eThe F-10300 is a \u003cstrong data-end=\"3132\" data-start=\"3114\"\u003efixed 3000 RPM\u003c\/strong\u003e unit and is listed at \u003cstrong data-end=\"3168\" data-start=\"3155\"\u003e1792g RCF\u003c\/strong\u003e. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"3246\" data-start=\"3211\"\u003e12) What power does it require?\u003c\/p\u003e\n\u003cp data-end=\"3521\" data-start=\"3247\"\u003eThe motor is listed as \u003cstrong data-end=\"3305\" data-start=\"3270\"\u003e110V (other voltages available)\u003c\/strong\u003e and uses a \u003cstrong data-end=\"3332\" data-start=\"3317\"\u003e1\/8 HP TEFC\u003c\/strong\u003e (totally enclosed fan-cooled) motor designed for industrial environments. If you need a non-standard voltage (e.g., 230V), confirm at time of order. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"3573\" data-start=\"3523\"\u003e13) How big is it, and how much does it weigh?\u003c\/p\u003e\n\u003cp data-end=\"3786\" data-start=\"3574\"\u003ePublished dimensions are approximately \u003cstrong data-end=\"3639\" data-start=\"3613\"\u003e16 in (41 cm) diameter\u003c\/strong\u003e by \u003cstrong data-end=\"3667\" data-start=\"3643\"\u003e13 in (33 cm) height\u003c\/strong\u003e. Net weight is listed around \u003cstrong data-end=\"3713\" data-start=\"3697\"\u003e20 lb (9 kg)\u003c\/strong\u003e (ship weight ~25 lb \/ 11.34 kg). \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"3824\" data-start=\"3788\"\u003e14) What warranty comes with it?\u003c\/p\u003e\n\u003cp data-end=\"3914\" data-start=\"3825\"\u003eThe F-10300 is listed with a \u003cstrong data-end=\"3873\" data-start=\"3854\"\u003e1-year warranty\u003c\/strong\u003e. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"3989\" data-start=\"3916\"\u003e15) If I need “official” MLSS numbers, what’s the correct lab method?\u003c\/p\u003e\n\u003cp data-end=\"4358\" data-start=\"3990\"\u003eIf you need defensible MLSS\/TSS numbers (mg\/L), operators commonly point to \u003cstrong data-end=\"4106\" data-start=\"4066\"\u003eStandard Methods (e.g., 2540 series)\u003c\/strong\u003e using glass fiber filters plus a controlled drying oven (commonly cited \u003cstrong data-end=\"4192\" data-start=\"4179\"\u003e103–105°C\u003c\/strong\u003e) and an analytical balance. The centrifuge is widely used as the fast day-of process tool, with lab methods as the reference.\u003c\/p\u003e","brand":"RavenEP","offers":[{"title":"F-10300 ~ ea","offer_id":47684887773443,"sku":"F-10300","price":2447.78,"currency_code":"CAD","in_stock":true},{"title":"B-10101-19 ~ pk\/12","offer_id":47684887806211,"sku":"B-10101-19","price":196.57,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/ProcessCentrifugeSide.png?v=1769453702"},{"product_id":"core-taker-sludge-sampler","title":"Coretaker® Regular Sludge Core Sampler","description":"\u003cp style=\"text-align: center;\" data-end=\"222\" data-start=\"200\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eCoretaker\u003cstrong data-end=\"266\" data-start=\"224\"\u003e®\u003c\/strong\u003e Regular Sludge Core Sampler\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cstrong data-end=\"1383\" data-start=\"1287\"\u003ePull an intact sludge core for fast sludge blanket checks in clarifiers, tanks, and lagoons.\u003c\/strong\u003e\u003cbr data-end=\"1386\" data-start=\"1383\"\u003eCORETAKER® is a rugged “sludge judge” style sampler built for municipal and industrial wastewater operators: \u003cstrong data-end=\"1532\" data-start=\"1495\"\u003eUV-stabilized clear polycarbonate\u003c\/strong\u003e, \u003cstrong data-end=\"1583\" data-start=\"1534\"\u003eSlip-Lock couplers with four internal O-rings\u003c\/strong\u003e, and a \u003cstrong data-end=\"1629\" data-start=\"1591\"\u003eCNC-machined automatic check valve\u003c\/strong\u003e for clean retrieval and fewer drips. It \u003cstrong data-end=\"1691\" data-start=\"1670\"\u003efloats if dropped\u003c\/strong\u003e and includes a \u003cstrong data-end=\"1759\" data-start=\"1707\"\u003eLifetime Break-Free Guarantee for USA and Canada\u003c\/strong\u003e.\u003c\/strong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"737\" data-start=\"224\"\u003e\u003cstrong data-end=\"266\" data-start=\"224\"\u003eCORETAKER® Regular Sludge Core Sampler\u003c\/strong\u003e is the most durable and reliable sludge sampler for industrial and municipal applications. Available in 8, 16, and 24-foot lengths, CORETAKER® allows operators to collect clear, intact sludge cores for inspection of color, texture, and settled sludge layers. Constructed from UV-stabilized clear polycarbonate, the sampler provides superior visibility while resisting breakage, and comes with a Lifetime Break-Free Guarantee on sales in the USA and Canada.\u003c\/p\u003e\n\u003cp data-end=\"1187\" data-start=\"739\"\u003eUniquely engineered with Slip-Lock couplers and CNC machined automatic check valves, CORETAKER® eliminates the common problems of threaded fittings. Its couplers feature four internal O-rings for 100% leak-proof connections, while the check valve ensures smooth flow and prevents drips. Factory-applied yellow depth markers assist in accurate sludge level measurements, with additional markers provided for optional user installation.\u003c\/p\u003e\n\u003cp data-end=\"1483\" data-start=\"1189\"\u003eReplacement sections are available for long-term maintenance: bottom \u0026amp; top sections for 16- and 24-foot models and a middle section for the 24-foot model, making it simple to replace worn parts and extend sampler life. The sampler is lightweight, floats, and is easy to handle in the field.\u003c\/p\u003e\n\u003cp data-end=\"1676\" data-start=\"1485\"\u003eCORETAKER® is ideal for applications such as wastewater treatment plants, industrial pre-treatment, and environmental monitoring, providing consistent, high-quality sampling every time.\u003c\/p\u003e\n\u003cp data-end=\"1676\" data-start=\"1485\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"2528\" data-start=\"1711\"\u003e\n\u003cli data-end=\"1789\" data-start=\"1711\"\u003e\n\u003cp data-end=\"1789\" data-start=\"1713\"\u003eAvailable in \u003cstrong data-end=\"1756\" data-start=\"1726\"\u003e8, 16, and 24-foot lengths\u003c\/strong\u003e to suit various sampling needs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1877\" data-start=\"1790\"\u003e\n\u003cp data-end=\"1877\" data-start=\"1792\"\u003e\u003cstrong data-end=\"1834\" data-start=\"1792\"\u003eUV-stabilized clear polycarbonate tube\u003c\/strong\u003e – superior clarity for inspecting sludge\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1987\" data-start=\"1878\"\u003e\n\u003cp data-end=\"1987\" data-start=\"1880\"\u003e\u003cstrong data-end=\"1924\" data-start=\"1880\"\u003eSlip-Lock couplers with internal O-rings\u003c\/strong\u003e – 100% leak-proof connections, no threaded fittings to break\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2093\" data-start=\"1988\"\u003e\n\u003cp data-end=\"2093\" data-start=\"1990\"\u003e\u003cstrong data-end=\"2028\" data-start=\"1990\"\u003eCNC machined automatic check valve\u003c\/strong\u003e – smooth flow and no drips, fewer parts for easier maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2186\" data-start=\"2094\"\u003e\n\u003cp data-end=\"2186\" data-start=\"2096\"\u003e\u003cstrong data-end=\"2136\" data-start=\"2096\"\u003eFactory-applied yellow depth markers\u003c\/strong\u003e – accurate measurement of settled sludge levels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2240\" data-start=\"2187\"\u003e\n\u003cp data-end=\"2240\" data-start=\"2189\"\u003e\u003cstrong data-end=\"2208\" data-start=\"2189\"\u003eFloats on water\u003c\/strong\u003e – easy handling and retrieval\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2321\" data-start=\"2241\"\u003e\n\u003cp data-end=\"2321\" data-start=\"2243\"\u003e\u003cstrong data-end=\"2276\" data-start=\"2243\"\u003eLifetime Break-Free Guarantee\u003c\/strong\u003e – peace of mind for USA and Canadian sales\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2407\" data-start=\"2322\"\u003e\n\u003cp data-end=\"2407\" data-start=\"2324\"\u003eLightweight and field-ready – ideal for environmental and wastewater applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2528\" data-start=\"2408\"\u003e\n\u003cp data-end=\"2528\" data-start=\"2410\"\u003eReplacement sections available:\u003cstrong\u003e top \u0026amp; \u003c\/strong\u003e\u003cstrong data-end=\"2488\" data-start=\"2442\"\u003ebottom sections for 16- and 24-foot models\u003c\/strong\u003e, \u003cstrong data-end=\"2526\" data-start=\"2490\"\u003emiddle section for 24-foot model\u003cbr\u003e\u003cbr\u003eDocumentation\u003cbr\u003e\u003c\/strong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/Coretaker_B-10104_Literature.pdf?v=1769528711\"\u003eBrochure\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/Coretaker_wastewater_application.pdf?v=1769528711\"\u003eWastewater Application\u003c\/a\u003e\u003cstrong data-end=\"2526\" data-start=\"2490\"\u003e\u003cbr\u003e\u003cbr\u003e\u003ciframe width=\"1011\" height=\"569\" src=\"https:\/\/www.youtube.com\/embed\/SjeWSNP66r4\" title=\"CORETAKER® SLUDGE SAMPLER DESIGN NOTES\"\u003e\u003c\/iframe\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"342\" data-end=\"402\"\u003eFAQ – CORETAKER® Sludge Core Sampler (Wastewater, Canada)\u003c\/h2\u003e\n\u003cp data-start=\"404\" data-end=\"676\"\u003e\u003cstrong data-start=\"404\" data-end=\"457\"\u003eWhat is CORETAKER® used for in wastewater plants?\u003c\/strong\u003e\u003cbr data-start=\"457\" data-end=\"460\"\u003eCORETAKER® is used to pull an intact sludge core so operators can assess sludge blanket conditions in clarifiers, tanks, and lagoons—helpful for checking settled solids profile, layering, texture, and colour changes.\u003c\/p\u003e\n\u003cp data-start=\"678\" data-end=\"884\"\u003e\u003cstrong data-start=\"678\" data-end=\"717\"\u003eIs this basically a “sludge judge”?\u003c\/strong\u003e\u003cbr data-start=\"717\" data-end=\"720\"\u003eYes. In operator terms, CORETAKER® is a sludge judge \/ sludge blanket sampler designed as a more durable, leak-tight option with a clear tube for visual inspection.\u003c\/p\u003e\n\u003cp data-start=\"886\" data-end=\"1393\"\u003e\u003cstrong data-start=\"886\" data-end=\"958\"\u003eWhy do sludge judges break so often—and how is CORETAKER® different?\u003c\/strong\u003e\u003cbr data-start=\"958\" data-end=\"961\"\u003eOperators commonly see sludge judges crack or fail from outdoor storage, UV exposure, and joint weakness. CORETAKER® uses a UV-stabilized clear polycarbonate tube and Slip-Lock couplers with internal O-rings to reduce break points and leaking. \u003c\/p\u003e\n\u003cp data-start=\"1395\" data-end=\"1653\"\u003e\u003cstrong data-start=\"1395\" data-end=\"1426\"\u003eDoes it leak at the joints?\u003c\/strong\u003e\u003cbr data-start=\"1426\" data-end=\"1429\"\u003eCORETAKER® uses Slip-Lock couplers and internal O-rings for leak-proof connections to help prevent drips and separation during sampling. \u003c\/p\u003e\n\u003cp data-start=\"1655\" data-end=\"1901\"\u003e\u003cstrong data-start=\"1655\" data-end=\"1715\"\u003eWhat keeps the sample from dumping out during retrieval?\u003c\/strong\u003e\u003cbr data-start=\"1715\" data-end=\"1718\"\u003eThe CNC-machined automatic check valve helps retain the core during retrieval and reduces mess. \u003cbr\u003e\u003cbr\u003e\u003ca data-start=\"1815\" data-end=\"1900\" class=\"decorated-link\" rel=\"noopener\" href=\"https:\/\/cambridgeenviro.com\/products\/core-taker-sludge-sampler?utm_source=chatgpt.com\"\u003e\u003c\/a\u003e\u003cstrong data-start=\"1903\" data-end=\"1948\"\u003eDoes CORETAKER® float if it gets dropped?\u003c\/strong\u003e\u003cbr data-start=\"1948\" data-end=\"1951\"\u003eYes—CORETAKER® is designed to float, which is useful around clarifiers and lagoons. \u003c\/p\u003e\n\u003cp data-start=\"2124\" data-end=\"2244\"\u003e\u003cstrong data-start=\"2124\" data-end=\"2181\"\u003eWhat length should I choose (8 ft vs 16 ft vs 24 ft)?\u003c\/strong\u003e\u003cbr data-start=\"2181\" data-end=\"2184\"\u003eChoose the length that matches your basin\/clarifier depth:\u003c\/p\u003e\n\u003cul data-start=\"2245\" data-end=\"2415\"\u003e\n\u003cli data-start=\"2245\" data-end=\"2288\"\u003e\n\u003cp data-start=\"2247\" data-end=\"2288\"\u003e\u003cstrong data-start=\"2247\" data-end=\"2255\"\u003e8 ft\u003c\/strong\u003e: shallow tanks, general checks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2289\" data-end=\"2337\"\u003e\n\u003cp data-start=\"2291\" data-end=\"2337\"\u003e\u003cstrong data-start=\"2291\" data-end=\"2300\"\u003e16 ft\u003c\/strong\u003e: common municipal clarifier depths\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2338\" data-end=\"2415\"\u003e\n\u003cp data-start=\"2340\" data-end=\"2415\"\u003e\u003cstrong data-start=\"2340\" data-end=\"2349\"\u003e24 ft\u003c\/strong\u003e: deeper clarifiers\/lagoons or where full depth coverage is needed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2417\" data-end=\"2735\"\u003e\u003cstrong data-start=\"2417\" data-end=\"2496\"\u003eCan we replace damaged tube sections instead of buying a whole new sampler?\u003c\/strong\u003e\u003cbr data-start=\"2496\" data-end=\"2499\"\u003eYes. Replacement tube sections are available for 16 ft and 24 ft units (top\/bottom; and a middle section for 24 ft), so you can extend service life. \u003c\/p\u003e\n\u003cp data-start=\"2737\" data-end=\"2939\"\u003e\u003cstrong data-start=\"2737\" data-end=\"2771\"\u003eDoes it include depth markers?\u003c\/strong\u003e\u003cbr data-start=\"2771\" data-end=\"2774\"\u003eYes. The tube includes factory-applied depth markers for consistent readings. \u003c\/p\u003e\n\u003cp data-start=\"2941\" data-end=\"3256\"\u003e\u003cstrong data-start=\"2941\" data-end=\"2995\"\u003eIs there a warranty\/guarantee for Canadian buyers?\u003c\/strong\u003e\u003cbr data-start=\"2995\" data-end=\"2998\"\u003eYour listing states a \u003cstrong data-start=\"3020\" data-end=\"3085\"\u003eLifetime Break-Free Guarantee for sales in the USA and Canada\u003c\/strong\u003e. Put this here because durability is the #1 operator complaint with sludge judges. \u003c\/p\u003e\n\u003cp data-start=\"3258\" data-end=\"3583\"\u003e\u003cstrong data-start=\"3258\" data-end=\"3316\"\u003eHow should we store it to make it last? (operator tip)\u003c\/strong\u003e\u003cbr data-start=\"3316\" data-end=\"3319\"\u003eIf possible, store out of constant sun\/UV exposure. Some operators keep samplers in a vertical PVC sleeve near the clarifier to protect it and keep it accessible. \u003cbr\u003e\u003cbr\u003e\u003cstrong data-start=\"3585\" data-end=\"3649\"\u003eWhat’s the easiest way to clean it after use? (operator tip)\u003c\/strong\u003e\u003cbr data-start=\"3649\" data-end=\"3652\"\u003eRinse with clean water after use and avoid letting residue dry inside the tube. Follow your site SOP for any disinfecting steps.\u003c\/p\u003e\n\u003cp data-end=\"2528\" data-start=\"2410\"\u003e\u003cstrong data-end=\"2526\" data-start=\"2490\"\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"RavenEP","offers":[{"title":"Default Title \/ 8ft","offer_id":47684976050435,"sku":"B-10104-8","price":215.17,"currency_code":"CAD","in_stock":false},{"title":"Default Title \/ 16ft","offer_id":47684976083203,"sku":"B-10104-16","price":273.29,"currency_code":"CAD","in_stock":false},{"title":"Default Title \/ 24ft","offer_id":47685015535875,"sku":"B-10104-24","price":398.57,"currency_code":"CAD","in_stock":false},{"title":"Default Title \/ Top Tube Replacement","offer_id":47687094010115,"sku":"B-10104-TOP","price":220.82,"currency_code":"CAD","in_stock":false},{"title":"Default Title \/ Middle Tube Replacement","offer_id":47685015568643,"sku":"B-10104-MIDDLE","price":234.29,"currency_code":"CAD","in_stock":false},{"title":"Default Title \/ Bottom Tube Replacement","offer_id":47685015601411,"sku":"B-10104-BOTTOM","price":190.14,"currency_code":"CAD","in_stock":false},{"title":"Default Title (Wholesale) \/ 8ft","offer_id":47684976115971,"sku":"B-10104-8","price":204.92,"currency_code":"CAD","in_stock":false},{"title":"Default Title (Wholesale) \/ 16ft","offer_id":47684976148739,"sku":"B-10104-16","price":260.28,"currency_code":"CAD","in_stock":false},{"title":"Default Title (Wholesale) \/ 24ft","offer_id":47685015634179,"sku":"B-10104-24","price":379.59,"currency_code":"CAD","in_stock":false},{"title":"Default Title (Wholesale) \/ Top Tube Replacement","offer_id":47687094042883,"sku":"B-10104-TOP","price":210.3,"currency_code":"CAD","in_stock":false},{"title":"Default Title (Wholesale) \/ Middle Tube Replacement","offer_id":47685015666947,"sku":"B-10104-MIDDLE","price":223.14,"currency_code":"CAD","in_stock":false},{"title":"Default Title (Wholesale) \/ Bottom Tube Replacement","offer_id":47685015699715,"sku":"B-10104-BOTTOM","price":181.09,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/Coretaker8ft.png?v=1769525731"},{"product_id":"coretaker-max-1-piece-sludge-sampler","title":"Coretaker® Max 1-Piece Sludge Sampler","description":"\u003cp data-start=\"200\" data-end=\"222\" style=\"text-align: center;\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eCoretaker® Max 1-Piece Sludge Sampler\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"182\" data-end=\"529\"\u003e\u003cstrong\u003eCORETAKER® MAX 1-Piece Sludge Sampler\u003c\/strong\u003e is designed for demanding applications involving heavy, settled solids where standard sludge samplers fall short. Ideal for septic pumping, inspections, grease traps, waste oil collection, and industrial sludge sampling, the CORETAKER® MAX delivers reliable core samples in tough field conditions.\u003c\/p\u003e\n\u003cp data-start=\"531\" data-end=\"935\"\u003eAvailable in 5-foot and 8-foot one-piece configurations, the CORETAKER® MAX features a Link Release Mega Valve that opens fully during insertion and automatically slams shut once the sampler is full, capturing dense sludge without loss. The integrated shepherd’s hook allows the valve to be held open for flushing from the clean end at the top, making post-sampling cleanup faster and easier.\u003c\/p\u003e\n\u003cp data-start=\"937\" data-end=\"1339\"\u003eConstructed from UV-stabilized clear polycarbonate with a CNC-machined UHMW polyethylene valve, the CORETAKER® MAX offers increased tube diameter for higher-volume sampling and improved flow through heavy solids. Factory-applied yellow depth markers provide accurate measurement of sludge levels, while the robust one-piece design minimizes setup time and simplifies operation in the field.\u003c\/p\u003e\n\u003cp data-start=\"1491\" data-end=\"1517\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1519\" data-end=\"2293\"\u003e\n\u003cli data-start=\"1519\" data-end=\"1599\"\u003e\n\u003cp data-start=\"1521\" data-end=\"1599\"\u003eAvailable in \u003cstrong data-start=\"1534\" data-end=\"1569\"\u003e5 ft and 8 ft one-piece lengths\u003c\/strong\u003e for fast, simple deployment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1600\" data-end=\"1696\"\u003e\n\u003cp data-start=\"1602\" data-end=\"1696\"\u003e\u003cstrong data-start=\"1602\" data-end=\"1629\"\u003eLink Release Mega Valve\u003c\/strong\u003e captures heavy, settled sludge and seals automatically when full\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1697\" data-end=\"1781\"\u003e\n\u003cp data-start=\"1699\" data-end=\"1781\"\u003e\u003cstrong data-start=\"1699\" data-end=\"1718\"\u003eShepherd’s hook\u003c\/strong\u003e keeps valve open for easy flushing and cleaning from the top\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1782\" data-end=\"1853\"\u003e\n\u003cp data-start=\"1784\" data-end=\"1853\"\u003e\u003cstrong data-start=\"1784\" data-end=\"1808\"\u003eLarger diameter tube\u003c\/strong\u003e improves flow and sampling of dense solids\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1854\" data-end=\"1933\"\u003e\n\u003cp data-start=\"1856\" data-end=\"1933\"\u003e\u003cstrong data-start=\"1856\" data-end=\"1880\"\u003eTwo internal O-rings\u003c\/strong\u003e in the check valve prevent leaking and sample loss\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1934\" data-end=\"2007\"\u003e\n\u003cp data-start=\"1936\" data-end=\"2007\"\u003e\u003cstrong data-start=\"1936\" data-end=\"1976\"\u003eCNC-machined UHMW polyethylene valve\u003c\/strong\u003e for strength and reliability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2008\" data-end=\"2086\"\u003e\n\u003cp data-start=\"2010\" data-end=\"2086\"\u003e\u003cstrong data-start=\"2010\" data-end=\"2052\"\u003eUV-stabilized clear polycarbonate tube\u003c\/strong\u003e for visual inspection of sludge\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2087\" data-end=\"2169\"\u003e\n\u003cp data-start=\"2089\" data-end=\"2169\"\u003e\u003cstrong data-start=\"2089\" data-end=\"2129\"\u003eFactory-applied yellow depth markers\u003c\/strong\u003e for accurate sludge level measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2170\" data-end=\"2253\"\u003e\n\u003cp data-start=\"2172\" data-end=\"2253\"\u003eDesigned for septic, grease trap, waste oil, and industrial sludge applications\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2410\" data-end=\"2528\"\u003e\u003cstrong data-start=\"2490\" data-end=\"2526\"\u003e\u003cbr\u003e\u003cbr\u003eDocumentation\u003cbr\u003e\u003c\/strong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/Coretaker_MAX_B-40404.pdf?v=1769529388\"\u003eBrochure\u003c\/a\u003e\u003cbr\u003e\u003cstrong data-start=\"2490\" data-end=\"2526\"\u003e\u003cbr\u003e\u003cbr\u003e\u003ciframe width=\"420\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/e5cSOD_nRvY\" title=\"Meet the Max - Designed for the heaviest sludge\"\u003e\u003c\/iframe\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"2410\" data-end=\"2528\"\u003e\u003cstrong data-start=\"2490\" data-end=\"2526\"\u003e\u003ciframe width=\"420\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/LTuZIxmZFm8\" title=\"Meet the Max - Mega Valve\"\u003e\u003c\/iframe\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"RavenEP","offers":[{"title":"Default Title \/ 5ft","offer_id":47687099384067,"sku":"B-40404-5","price":263.51,"currency_code":"CAD","in_stock":false},{"title":"Default Title \/ 8ft","offer_id":47687099416835,"sku":"B-40404-8","price":289.28,"currency_code":"CAD","in_stock":false},{"title":"Default Title (Wholesale) \/ 5ft","offer_id":47687099580675,"sku":"B-40404-5","price":210.81,"currency_code":"CAD","in_stock":false},{"title":"Default Title (Wholesale) \/ 8ft","offer_id":47687099613443,"sku":"B-40404-8","price":231.42,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/B-40404-2T.jpg?v=1769529507"},{"product_id":"coretaker-max-2-piece-sludge-sampler","title":"Coretaker® Max 2-Piece Sludge Sampler","description":"\u003cp style=\"text-align: center;\" data-end=\"222\" data-start=\"200\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eCoretaker® Max 1-Piece Sludge Sampler\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-end=\"2293\" data-start=\"1519\"\u003e\n\u003cli data-end=\"2253\" data-start=\"2170\"\u003e\n\u003cp data-end=\"566\" data-start=\"184\"\u003e\u003cstrong data-end=\"225\" data-start=\"184\"\u003eCORETAKER® MAX 2-Piece Sludge Sampler\u003c\/strong\u003e is designed for inspectors and compliance personnel who need the heavy-solids performance of the CORETAKER® MAX with added convenience for transport and storage. Available in 2-piece 6-foot and 2-piece 8-foot configurations, this model breaks down into compact sections while delivering the same sampling performance as the 1-piece MAX.\u003c\/p\u003e\n\u003cp data-end=\"837\" data-start=\"568\"\u003eThe two sections connect quickly using a\u003cstrong\u003e \u003c\/strong\u003eSlip-Lock coupler with a brass thumbscrew, creating a secure, leak-free assembly in the field. Disassembly is just as fast, allowing the sampler to fit neatly into a rugged carrying case for easy transport between job sites.\u003c\/p\u003e\n\u003cp data-end=\"1194\" data-start=\"839\"\u003eLike the 1-piece version, the CORETAKER® MAX 2-Piece features the Link Release Mega Valve, which opens fully during insertion and automatically closes when full to capture heavy, settled sludge without sample loss. The shepherd’s hook allows the valve to be held open for flushing from the clean end at the top, simplifying cleanup after sampling.\u003c\/p\u003e\n\u003cp data-end=\"1609\" data-start=\"1196\"\u003eConstructed from UV-stabilized clear polycarbonate with CNC-machined UHMW polyethylene components, the CORETAKER® MAX 2-Piece offers increased tube diameter for improved flow through dense solids. Factory-applied yellow depth markers provide accurate sludge level measurements, making this sampler well suited for septic systems, grease traps, waste oil collection, and industrial sludge applications.\u003c\/p\u003e\n\u003cp data-end=\"1642\" data-start=\"1616\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"2342\" data-start=\"1644\"\u003e\n\u003cli data-end=\"1709\" data-start=\"1644\"\u003eCarrying Case Included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul data-end=\"2342\" data-start=\"1644\"\u003e\n\u003cli data-end=\"1709\" data-start=\"1644\"\u003e\n\u003cp data-end=\"1709\" data-start=\"1646\"\u003eAvailable in \u003cstrong data-end=\"1707\" data-start=\"1659\"\u003e2-piece 6 ft and 2-piece 8 ft configurations\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1768\" data-start=\"1710\"\u003e\n\u003cp data-end=\"1768\" data-start=\"1712\"\u003e\u003cstrong data-end=\"1733\" data-start=\"1712\"\u003eBreak-down design\u003c\/strong\u003e for easier transport and storage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1842\" data-start=\"1769\"\u003e\n\u003cp data-end=\"1842\" data-start=\"1771\"\u003e\u003cstrong data-end=\"1814\" data-start=\"1771\"\u003eSlip-Lock coupler with brass thumbscrew\u003c\/strong\u003e for fast, secure assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1929\" data-start=\"1843\"\u003e\n\u003cp data-end=\"1929\" data-start=\"1845\"\u003e\u003cstrong data-end=\"1872\" data-start=\"1845\"\u003eLink Release Mega Valve\u003c\/strong\u003e captures heavy, settled sludge and seals automatically\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2001\" data-start=\"1930\"\u003e\n\u003cp data-end=\"2001\" data-start=\"1932\"\u003e\u003cstrong data-end=\"1951\" data-start=\"1932\"\u003eShepherd’s hook\u003c\/strong\u003e keeps valve open for easy flushing and cleaning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2064\" data-start=\"2002\"\u003e\n\u003cp data-end=\"2064\" data-start=\"2004\"\u003e\u003cstrong data-end=\"2028\" data-start=\"2004\"\u003eLarger diameter tube\u003c\/strong\u003e improves sampling of dense solids\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2125\" data-start=\"2065\"\u003e\n\u003cp data-end=\"2125\" data-start=\"2067\"\u003e\u003cstrong data-end=\"2091\" data-start=\"2067\"\u003eTwo internal O-rings\u003c\/strong\u003e prevent leaking and sample loss\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2194\" data-start=\"2126\"\u003e\n\u003cp data-end=\"2194\" data-start=\"2128\"\u003e\u003cstrong data-end=\"2170\" data-start=\"2128\"\u003eUV-stabilized clear polycarbonate tube\u003c\/strong\u003e for visual inspection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2265\" data-start=\"2195\"\u003e\n\u003cp data-end=\"2265\" data-start=\"2197\"\u003e\u003cstrong data-end=\"2237\" data-start=\"2197\"\u003eFactory-applied yellow depth markers\u003c\/strong\u003e for accurate measurements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2342\" data-start=\"2266\"\u003e\n\u003cp data-end=\"2342\" data-start=\"2268\"\u003eBuilt for septic, grease trap, waste oil, and industrial sludge sampling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2528\" data-start=\"2410\"\u003e\u003cstrong data-end=\"2526\" data-start=\"2490\"\u003e\u003cbr\u003e\u003cbr\u003eDocumentation\u003cbr\u003e\u003c\/strong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/2-PIECE_CORETAKER_MAX.pdf?v=1769533507\"\u003eBrochure\u003c\/a\u003e\u003cbr\u003e\u003cstrong data-end=\"2526\" data-start=\"2490\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"RavenEP","offers":[{"title":"Default Title \/ 6ft","offer_id":47687136477443,"sku":"B-40500-6","price":380.99,"currency_code":"CAD","in_stock":false},{"title":"Default Title \/ 8ft","offer_id":47687136510211,"sku":"B-40500-8","price":418.35,"currency_code":"CAD","in_stock":false},{"title":"Default Title (Wholesale) \/ 6ft","offer_id":47687136542979,"sku":"B-40500-6","price":304.7,"currency_code":"CAD","in_stock":false},{"title":"Default Title (Wholesale) \/ 8ft","offer_id":47687136575747,"sku":"B-40500-8","price":334.68,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/B-40500-2T.jpg?v=1769533402"},{"product_id":"settleometer-kit-sv30-ssv-canada","title":"Settleometer Kit for SV30 (SSV) Settling Test – Wastewater","description":"\u003cp style=\"text-align: center;\" data-end=\"207\" data-start=\"185\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eSettleometer Kit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"2714\" data-start=\"2651\"\u003e\u003cstrong data-end=\"2714\" data-start=\"2651\"\u003eSettleometer Kit (SV30 \/ SSV) for Activated Sludge – Canada\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-end=\"3121\" data-start=\"2716\"\u003eThe Settleometer Kit is a fast, operator-friendly tool for measuring \u003cstrong data-end=\"2814\" data-start=\"2785\"\u003eSV30 settling performance\u003c\/strong\u003e and \u003cstrong data-end=\"2850\" data-start=\"2819\"\u003eSettled Sludge Volume (SSV)\u003c\/strong\u003e in activated sludge systems. It helps wastewater operators quickly see how solids separate from liquid over time—supporting better day-to-day control of \u003cstrong data-end=\"3028\" data-start=\"3004\"\u003esecondary clarifiers\u003c\/strong\u003e, solids inventory, and overall biological performance. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"3457\" data-start=\"3123\"\u003e\u003cstrong data-end=\"3156\" data-start=\"3123\"\u003eDual-scale readings (SSV + %)\u003c\/strong\u003e\u003cbr data-end=\"3159\" data-start=\"3156\"\u003eLarge, easy-to-read markings show \u003cstrong data-end=\"3215\" data-start=\"3193\"\u003eSSV from 0–1000 mL\u003c\/strong\u003e and \u003cstrong data-end=\"3245\" data-start=\"3220\"\u003e0–100% settled volume\u003c\/strong\u003e, making it simple to record SV30 results consistently across shifts. A \u003cstrong data-end=\"3332\" data-start=\"3317\"\u003esnap-on lid\u003c\/strong\u003e reduces splashing during transport from the aeration basin to the lab or control room. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"3483\" data-start=\"3459\"\u003e\u003cstrong data-end=\"3483\" data-start=\"3459\"\u003eWhy operators use it\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"3760\" data-start=\"3484\"\u003e\n\u003cli data-end=\"3570\" data-start=\"3484\"\u003e\n\u003cp data-end=\"3570\" data-start=\"3486\"\u003eSpot \u003cstrong data-end=\"3527\" data-start=\"3491\"\u003erapid vs normal vs slow settling\u003c\/strong\u003e before it becomes a clarifier loss event\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3653\" data-start=\"3571\"\u003e\n\u003cp data-end=\"3653\" data-start=\"3573\"\u003eSupport process decisions (RAS\/WAS adjustments, settleability troubleshooting)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3760\" data-start=\"3654\"\u003e\n\u003cp data-end=\"3760\" data-start=\"3656\"\u003eCompare settling behaviour over time or between basins (including dilution comparisons where applicable)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"3804\" data-start=\"3762\"\u003e\u003cstrong data-end=\"3804\" data-start=\"3762\"\u003eHow to run an SV30 settle test (quick)\u003c\/strong\u003e\u003c\/p\u003e\n\u003col data-end=\"3932\" data-start=\"3805\"\u003e\n\u003cli data-end=\"3848\" data-start=\"3805\"\u003e\n\u003cp data-end=\"3848\" data-start=\"3808\"\u003eFill to 1000 mL with well-mixed sample\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3888\" data-start=\"3849\"\u003e\n\u003cp data-end=\"3888\" data-start=\"3852\"\u003eStart timer; let settle 30 minutes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3932\" data-start=\"3889\"\u003e\n\u003cp data-end=\"3932\" data-start=\"3892\"\u003eRecord SV30 as \u003cstrong data-end=\"3919\" data-start=\"3907\"\u003eSSV (mL)\u003c\/strong\u003e and\/or \u003cstrong data-end=\"3932\" data-start=\"3927\"\u003e%\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp data-end=\"4110\" data-start=\"3934\"\u003e \u003c\/p\u003e\n\u003cp data-end=\"1474\" data-start=\"1448\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"2093\" data-start=\"1476\"\u003e\n\u003cli data-end=\"1555\" data-start=\"1476\"\u003e\n\u003cp data-end=\"1555\" data-start=\"1478\"\u003eClearly measures \u003cstrong data-end=\"1526\" data-start=\"1495\"\u003esettled sludge volume (SSV)\u003c\/strong\u003e and percent settled volume\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1635\" data-start=\"1556\"\u003e\n\u003cp data-end=\"1635\" data-start=\"1558\"\u003e\u003cstrong data-end=\"1581\" data-start=\"1558\"\u003eDual-scale markings\u003c\/strong\u003e from 0–100% and 0–1000 SSV for quick interpretation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1714\" data-start=\"1636\"\u003e\n\u003cp data-end=\"1714\" data-start=\"1638\"\u003eHelps evaluate \u003cstrong data-end=\"1688\" data-start=\"1653\"\u003esludge settling characteristics\u003c\/strong\u003e in secondary clarifiers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1805\" data-start=\"1715\"\u003e\n\u003cp data-end=\"1805\" data-start=\"1717\"\u003eSupports \u003cstrong data-end=\"1755\" data-start=\"1726\"\u003eprocess control decisions\u003c\/strong\u003e, including return sludge flow rate calculations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1875\" data-start=\"1806\"\u003e\n\u003cp data-end=\"1875\" data-start=\"1808\"\u003eUseful for identifying \u003cstrong data-end=\"1873\" data-start=\"1831\"\u003erapid, normal, or slow settling sludge\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1962\" data-start=\"1876\"\u003e\n\u003cp data-end=\"1962\" data-start=\"1878\"\u003eEnables \u003cstrong data-end=\"1912\" data-start=\"1886\"\u003emulti-dilution testing\u003c\/strong\u003e to distinguish density vs. concentration issues\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2024\" data-start=\"1963\"\u003e\n\u003cp data-end=\"2024\" data-start=\"1965\"\u003e\u003cstrong data-end=\"1980\" data-start=\"1965\"\u003eSnap-on lid\u003c\/strong\u003e reduces splashing during sample transport\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2093\" data-start=\"2025\"\u003e\n\u003cp data-end=\"2093\" data-start=\"2027\"\u003eSimple, durable design suitable for routine wastewater plant use\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp data-end=\"4281\" data-start=\"4274\"\u003e\u003cstrong data-end=\"4281\" data-start=\"4274\"\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003col data-end=\"5557\" data-start=\"4282\"\u003e\n\u003cli data-end=\"4480\" data-start=\"4282\"\u003e\n\u003cp data-end=\"4480\" data-start=\"4285\"\u003e\u003cstrong data-end=\"4308\" data-start=\"4285\"\u003eWhat is SV30 \/ SSV?\u003c\/strong\u003e\u003cbr data-end=\"4311\" data-start=\"4308\"\u003eSV30 is the settled sludge volume after 30 minutes. SSV is the settled volume reading (commonly recorded in mL at 30 minutes). \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"4696\" data-start=\"4481\"\u003e\n\u003cp data-end=\"4696\" data-start=\"4484\"\u003e\u003cstrong data-end=\"4539\" data-start=\"4484\"\u003eWhy does the Settleometer show both % and SSV (mL)?\u003c\/strong\u003e\u003cbr data-end=\"4542\" data-start=\"4539\"\u003eThe dual scale lets you record results in either format for easier trending and communication across operators. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"4890\" data-start=\"4697\"\u003e\n\u003cp data-end=\"4890\" data-start=\"4700\"\u003e\u003cstrong data-end=\"4727\" data-start=\"4700\"\u003eWhere do I sample from?\u003c\/strong\u003e\u003cbr data-end=\"4730\" data-start=\"4727\"\u003eMost plants use a well-mixed sample from the \u003cstrong data-end=\"4809\" data-start=\"4778\"\u003eaeration basin mixed liquor\u003c\/strong\u003e (or wherever your SV30 SOP specifies). \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"5097\" data-start=\"4891\"\u003e\n\u003cp data-end=\"5097\" data-start=\"4894\"\u003e\u003cstrong data-end=\"4930\" data-start=\"4894\"\u003eDo I only read it at 30 minutes?\u003c\/strong\u003e\u003cbr data-end=\"4933\" data-start=\"4930\"\u003eSV30 is standard, but many operators also take 5-minute readings early on to see settling behaviour (a settling curve). \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"5318\" data-start=\"5098\"\u003e\n\u003cp data-end=\"5318\" data-start=\"5101\"\u003e\u003cstrong data-end=\"5148\" data-start=\"5101\"\u003eIs this the Raven C-10102 Settleometer kit?\u003c\/strong\u003e\u003cbr data-end=\"5151\" data-start=\"5148\"\u003eYour SKU shows \u003cstrong data-end=\"5180\" data-start=\"5169\"\u003eC-10102\u003c\/strong\u003e—call out the manufacturer\/brand explicitly on the page if it’s Raven to capture brand searches. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"5557\" data-start=\"5319\"\u003e\n\u003cp data-end=\"5557\" data-start=\"5322\"\u003e\u003cstrong data-end=\"5366\" data-start=\"5322\"\u003eCan this help diagnose clarifier issues?\u003c\/strong\u003e\u003cbr data-end=\"5369\" data-start=\"5366\"\u003eYes—settling behaviour trends are commonly used to flag developing settleability and solids separation problems before they show up as carryover. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp data-end=\"2093\" data-start=\"2027\"\u003e\u003cbr\u003e\u003cstrong data-end=\"2785\" data-start=\"2766\"\u003e\u003c\/strong\u003e\u003cstrong data-end=\"3957\" data-start=\"3934\"\u003eShips within Canada\u003c\/strong\u003e\u003cbr data-end=\"3960\" data-start=\"3957\"\u003eSold and supported by Cambridge Environmental Products (Ontario). Add this to your activated sludge bench tools for consistent settleability tracking.\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"RavenEP","offers":[{"title":"Default","offer_id":47687599456515,"sku":"C-10102","price":123.3,"currency_code":"CAD","in_stock":true},{"title":"Default (Wholesale)","offer_id":47687599489283,"sku":"C-10102","price":112.09,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/Settleometer.jpg?v=1769541234"},{"product_id":"sludge-interface","title":"Sludge Interface Detector","description":"\u003cp data-start=\"203\" data-end=\"676\" style=\"text-align: center;\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong data-start=\"203\" data-end=\"248\"\u003eSludge Interface Detector\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"203\" data-end=\"676\"\u003e\u003cstrong data-start=\"203\" data-end=\"248\"\u003eRaven SID-20200 Sludge Interface Detector\u003c\/strong\u003e is a portable, handheld instrument designed to accurately measure sludge blanket depth in wastewater treatment applications. Suitable for primary tanks, clarifiers, sedimentation basins, lagoons, and tanks with settled solids, the SID-20200 provides fast, reliable interface detection for process monitoring and control. This model replaces the earlier SID-10200 and incorporates several performance and usability upgrades.\u003c\/p\u003e\n\u003cp data-start=\"678\" data-end=\"1126\"\u003eAvailable with 20, 30, or 50-foot probe and cable lengths, the SID-20200 features a counter roller system that eliminates the need for cable markers and delivers precise depth measurements. The backlit digital display shows sludge interface depth in inches or centimetres, allowing operators to easily document results under all lighting conditions. Adjustable sensitivity ensures reliable detection across a wide range of sludge types.\u003c\/p\u003e\n\u003cp data-start=\"1128\" data-end=\"1473\"\u003eThe detector uses an infrared sensor probe connected by a strain-relieved signal cable, with waterproof protection rated IP68 up to 50 feet, while the handheld unit is housed in an IP66 weather-resistant case. Audible and visual indicators confirm interface detection, and a low battery indicator helps prevent downtime in the field.\u003c\/p\u003e\n\u003cp data-start=\"1475\" data-end=\"1760\"\u003eReplacement probe and cable assemblies are available for ongoing maintenance, allowing the instrument to remain in service for years with straightforward upkeep. Built in the USA, the SID-20200 is a dependable solution for accurate sludge blanket measurement in demanding environments.\u003c\/p\u003e\n\u003cp data-start=\"1767\" data-end=\"1793\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1795\" data-end=\"2577\"\u003e\n\u003cli data-start=\"1795\" data-end=\"1864\"\u003e\n\u003cp data-start=\"1797\" data-end=\"1864\"\u003eAvailable with \u003cstrong data-start=\"1812\" data-end=\"1862\"\u003e20 ft, 30 ft, or 50 ft probe and cable lengths\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1865\" data-end=\"1938\"\u003e\n\u003cp data-start=\"1867\" data-end=\"1938\"\u003eAccurately determines \u003cstrong data-start=\"1889\" data-end=\"1936\"\u003esludge blanket solid\/liquid interface depth\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1939\" data-end=\"2018\"\u003e\n\u003cp data-start=\"1941\" data-end=\"2018\"\u003e\u003cstrong data-start=\"1941\" data-end=\"1966\"\u003eCounter roller system\u003c\/strong\u003e provides exact measurements without cable markers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2019\" data-end=\"2079\"\u003e\n\u003cp data-start=\"2021\" data-end=\"2079\"\u003e\u003cstrong data-start=\"2021\" data-end=\"2040\"\u003eDigital display\u003c\/strong\u003e shows depth in inches or centimeters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2080\" data-end=\"2140\"\u003e\n\u003cp data-start=\"2082\" data-end=\"2140\"\u003e\u003cstrong data-start=\"2082\" data-end=\"2108\"\u003eAdjustable sensitivity\u003c\/strong\u003e for varying sludge conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2141\" data-end=\"2196\"\u003e\n\u003cp data-start=\"2143\" data-end=\"2196\"\u003e\u003cstrong data-start=\"2143\" data-end=\"2162\"\u003eBacklit display\u003c\/strong\u003e for low-light and nighttime use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2197\" data-end=\"2261\"\u003e\n\u003cp data-start=\"2199\" data-end=\"2261\"\u003e\u003cstrong data-start=\"2199\" data-end=\"2215\"\u003eAudible horn\u003c\/strong\u003e with on\/off control for interface detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2262\" data-end=\"2320\"\u003e\n\u003cp data-start=\"2264\" data-end=\"2320\"\u003e\u003cstrong data-start=\"2264\" data-end=\"2289\"\u003eLow battery indicator\u003c\/strong\u003e for reliable field operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2321\" data-end=\"2379\"\u003e\n\u003cp data-start=\"2323\" data-end=\"2379\"\u003e\u003cstrong data-start=\"2323\" data-end=\"2354\"\u003eIP66 weather-resistant case\u003c\/strong\u003e for harsh environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2380\" data-end=\"2444\"\u003e\n\u003cp data-start=\"2382\" data-end=\"2444\"\u003e\u003cstrong data-start=\"2382\" data-end=\"2417\"\u003eIP68 waterproof probe and cable\u003c\/strong\u003e rated up to 50 ft (15 m)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2445\" data-end=\"2504\"\u003e\n\u003cp data-start=\"2447\" data-end=\"2504\"\u003eInfrared sensor probe with strain-relieved signal cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2505\" data-end=\"2557\"\u003e\n\u003cp data-start=\"2507\" data-end=\"2557\"\u003eReplacement probe and cable assemblies available\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2528\" data-start=\"2410\"\u003e\u003cstrong data-end=\"2526\" data-start=\"2490\"\u003eDocumentation\u003cbr\u003e\u003c\/strong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/SID-20200_Literature.pdf?v=1769542167\"\u003eBrochure\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/RP-20203_Probe_Replacement_Instructions.pdf?v=1769542167\"\u003eProbe Replacement\u003c\/a\u003e\u003cstrong data-end=\"2526\" data-start=\"2490\"\u003e\u003cbr\u003e\u003cbr\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5821\" data-end=\"6102\"\u003e\u003cstrong data-start=\"5821\" data-end=\"5873\"\u003eIs this the same as a “sludge blanket detector”?\u003c\/strong\u003e\u003cbr data-start=\"5873\" data-end=\"5876\"\u003eYes. Operators commonly use “sludge interface detector” and “sludge blanket detector” interchangeably. The SID-20200 detects the solid\/liquid interface so you can record blanket depth. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"6104\" data-end=\"6321\"\u003e\u003cstrong data-start=\"6104\" data-end=\"6135\"\u003eWhat tanks can I use it in?\u003c\/strong\u003e\u003cbr data-start=\"6135\" data-end=\"6138\"\u003ePrimary clarifiers, secondary clarifiers (where applicable), sedimentation basins, lagoons, and most settling tanks with a defined interface. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"6323\" data-end=\"6465\"\u003e\u003cstrong data-start=\"6323\" data-end=\"6362\"\u003eIs the SID-20200 the current model?\u003c\/strong\u003e\u003cbr data-start=\"6362\" data-end=\"6365\"\u003eYes—Raven states the \u003cstrong data-start=\"6386\" data-end=\"6422\"\u003eSID-20200 replaces the SID-10200\u003c\/strong\u003e. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"6467\" data-end=\"6597\"\u003e\u003cstrong data-start=\"6467\" data-end=\"6500\"\u003eDoes it show depth in metric?\u003c\/strong\u003e\u003cbr data-start=\"6500\" data-end=\"6503\"\u003eYes. The display can show \u003cstrong data-start=\"6529\" data-end=\"6554\"\u003einches or centimeters\u003c\/strong\u003e. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"6599\" data-end=\"6773\"\u003e\u003cstrong data-start=\"6599\" data-end=\"6641\"\u003eHow do I pick 20 ft vs 30 ft vs 50 ft?\u003c\/strong\u003e\u003cbr data-start=\"6641\" data-end=\"6644\"\u003eChoose based on tank depth + how far you stand from the access point\/handrail. When in doubt, 30 ft is the most versatile option.\u003c\/p\u003e\n\u003cp data-start=\"6775\" data-end=\"6912\"\u003e\u003cstrong data-start=\"6775\" data-end=\"6814\"\u003eCan I replace just the probe\/cable?\u003c\/strong\u003e\u003cbr data-start=\"6814\" data-end=\"6817\"\u003eYes—replacement probe\/cable assemblies are available. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"6914\" data-end=\"7070\"\u003e\u003cstrong data-start=\"6914\" data-end=\"6952\"\u003eIs it rugged enough for field use?\u003c\/strong\u003e\u003cbr data-start=\"6952\" data-end=\"6955\"\u003eThe handheld unit is listed as \u003cstrong data-start=\"6986\" data-end=\"6994\"\u003eIP66\u003c\/strong\u003e, and the probe\/cable is \u003cstrong data-start=\"7019\" data-end=\"7027\"\u003eIP68\u003c\/strong\u003e. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"7072\" data-end=\"7218\"\u003e\u003cstrong data-start=\"7072\" data-end=\"7122\"\u003eDoes it make noise when it hits the interface?\u003c\/strong\u003e\u003cbr data-start=\"7122\" data-end=\"7125\"\u003eYes—there’s an audible horn plus visual indication. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"7220\" data-end=\"7430\"\u003e\u003cstrong data-start=\"7220\" data-end=\"7246\"\u003eDo I need calibration?\u003c\/strong\u003e\u003cbr data-start=\"7246\" data-end=\"7249\"\u003eFor typical process control trending, operators focus on repeatable technique and consistent measurement points. (If you want, add an internal SOP PDF download to strengthen trust.)\u003c\/p\u003e\n\u003cp data-start=\"7432\" data-end=\"7650\"\u003e\u003cstrong data-start=\"7432\" data-end=\"7470\"\u003eIs this for continuous monitoring?\u003c\/strong\u003e\u003cbr data-start=\"7470\" data-end=\"7473\"\u003eNo—this is a portable spot-check tool. For continuous blanket monitoring, plants typically use fixed ultrasonic\/sonar blanket monitors. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"7652\" data-end=\"7789\"\u003e\u003cstrong data-start=\"7652\" data-end=\"7680\"\u003eDo you ship from Canada?\u003c\/strong\u003e\u003cbr data-start=\"7680\" data-end=\"7683\"\u003eShips from our Ontario warehouse with Canadian checkout (no brokerage surprises).\u003c\/p\u003e\n\u003cp data-end=\"2528\" data-start=\"2410\"\u003e\u003cstrong data-end=\"2526\" data-start=\"2490\"\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"RavenEP","offers":[{"title":"Default Title \/ 20ft Detector","offer_id":47687651852547,"sku":"SID-20200-20","price":1918.85,"currency_code":"CAD","in_stock":true},{"title":"Default Title \/ 30ft Detector","offer_id":47687651885315,"sku":"SID-20200-30","price":1981.61,"currency_code":"CAD","in_stock":true},{"title":"Default Title \/ 50ft Detector","offer_id":47687651918083,"sku":"SID-20200-50","price":2119.65,"currency_code":"CAD","in_stock":true},{"title":"Default Title \/ 20ft Probe Replacement","offer_id":47687651950851,"sku":"RP-20203-20","price":741.77,"currency_code":"CAD","in_stock":true},{"title":"Default Title \/ 30ft Probe Replacement","offer_id":47687788953859,"sku":"RP-20203-30","price":802.87,"currency_code":"CAD","in_stock":true},{"title":"Default Title \/ 50ft Probe Replacement","offer_id":47687788986627,"sku":"RP-20203-50","price":948.82,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale) \/ 20ft Detector","offer_id":47687652049155,"sku":"SID-20200-20","price":1535.08,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale) \/ 30ft Detector","offer_id":47687652081923,"sku":"SID-20200-30","price":1585.29,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale) \/ 50ft Detector","offer_id":47687652114691,"sku":"SID-20200-50","price":1695.72,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale) \/ 20ft Probe Replacement","offer_id":47687652147459,"sku":"RP-20203-20","price":593.41,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale) \/ 30ft Probe Replacement","offer_id":47687789019395,"sku":"RP-20203-30","price":642.3,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale) \/ 50ft Probe Replacement","offer_id":47687789052163,"sku":"RP-20203-50","price":759.06,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/SID-20200-2.png?v=1769542329"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/collections\/Raven_Environmental_products_Inc_logo.png?v=1768938458","url":"https:\/\/cambridgeenviro.com\/collections\/raven-environmental-products.oembed","provider":"Cambridge Environmental Products, Inc.","version":"1.0","type":"link"}