{"title":"Ohaus Electrodes","description":"","products":[{"product_id":"ph-testing-storp2","title":"Ohaus STORP2 Glass Refillable ORP Electrode","description":"\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cu\u003eOhaus STORP2 Glass Refillable ORP Electrode \u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe OHAUS Starter Series of electrodes are designed to produce exact results time and time again.  They fit perfectly in the electrode holders on OHAUS bench meters as well as electrode clips on all OHAUS portable meters. \u003c\/p\u003e\n\u003cp\u003eOxidation-Reduction Potential (ORP) electrodes test for the overall availability of electrons in a medium, specifically the ratio of positive and negative ions in the solution. They are also sometimes referred to as Redox electrodes. ORP is the only practical method used to electronically monitor sanitizer effectiveness and it is also commonly tested in water, such as swimming pools and aquariums.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eSpecifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eShaft Material: Glass\u003c\/li\u003e\n\u003cli\u003eTemperature Range: 0-100 ˚C\u003c\/li\u003e\n\u003cli\u003eInternal Reference Type: Ag\/AgCl\u003c\/li\u003e\n\u003cli\u003eRefillable\/Non-refillable: Refillable\u003c\/li\u003e\n\u003cli\u003eReference Junction Type: Annular Ceramic\u003c\/li\u003e\n\u003cli\u003eRefilling Reference Electrolyte: 3M KCI Solution\u003c\/li\u003e\n\u003cli\u003eDimensions (Shaft): 120 x 12mm\u003c\/li\u003e\n\u003cli\u003eCable Length: 1m\u003c\/li\u003e\n\u003cli\u003eTemperature Sensor: No\u003c\/li\u003e\n\u003cli\u003eConnector: BNC\u003c\/li\u003e\n\u003cli\u003eZero Potential Value: 86mV±15mV\u003c\/li\u003e\n\u003cli\u003eGrade Difference: ≥ 165mV\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cu\u003eCARE AND USE\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo ensure accurate measurements, it is important to keep the electrode clean. Contamination can cause inaccurate results and slow response times.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/dmx.ohaus.com\/WorkArea\/showcontent.aspx?id=34016\" target=\"_blank\"\u003eStarter Series Electrodes Data Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"Ohaus","offers":[{"title":"Default Title","offer_id":238456864794,"sku":"STORP2","price":463.14,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/STORP2_DMX-ID_29446_WebShop.jpg?v=1630678441"},{"product_id":"ph-testing-storp1","title":"Ohaus STORP1 Plastic Gel ORP Electrode","description":"\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cu\u003eOhaus STORP1 Plastic Gel ORP Electrode \u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe OHAUS Starter Series of electrodes are designed to produce exact results time and time again.  They fit perfectly in the electrode holders on OHAUS bench meters as well as electrode clips on all OHAUS portable meters. \u003c\/p\u003e\n\u003cp\u003eOxidation-Reduction Potential (ORP) electrodes test for the overall availability of electrons in a medium, specifically the ratio of positive and negative ions in the solution. They are also sometimes referred to as Redox electrodes. ORP is the only practical method used to electronically monitor sanitizer effectiveness and it is also commonly tested in water, such as swimming pools and aquariums.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eSpecifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eShaft Material: Plastic\u003c\/li\u003e\n\u003cli\u003eTemperature Range: 0-80 ˚C\u003c\/li\u003e\n\u003cli\u003eInternal Reference Type: Ag\/AgCl\u003c\/li\u003e\n\u003cli\u003eRefillable\/Non-refillable: Non-refillable, gel\u003c\/li\u003e\n\u003cli\u003eReference Junction Type: Ceramic Pin\u003c\/li\u003e\n\u003cli\u003eRefilling Reference Electrolyte: 3M KCI Gel\u003c\/li\u003e\n\u003cli\u003eDimensions (Shaft): 120 x 12mm\u003c\/li\u003e\n\u003cli\u003eCable Length: 1m\u003c\/li\u003e\n\u003cli\u003eTemperature Sensor: No\u003c\/li\u003e\n\u003cli\u003eConnector: BNC\u003c\/li\u003e\n\u003cli\u003eZero Potential Value: 86mV±15mV\u003c\/li\u003e\n\u003cli\u003eGrade Difference: ≥ 165mV\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cu\u003eCARE AND USE\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo ensure accurate measurements, it is important to keep the electrode clean. Contamination can cause inaccurate results and slow response times.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/dmx.ohaus.com\/WorkArea\/showcontent.aspx?id=34016\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e Starter Series Electrodes Data Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"Ohaus","offers":[{"title":"Default Title","offer_id":238457061402,"sku":"STORP1","price":197.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/storp1_89c02378-c560-4543-937e-829362d12d4c.jpg?v=1569173909"},{"product_id":"ph-testing-stref1","title":"Ohaus STREF1 Glass Starter Reference Electrode","description":"\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cu\u003eOhaus STREF1 Glass Starter Reference Electrode \u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe OHAUS Starter Series of electrodes are designed to produce exact results time and time again.  They fit perfectly in the electrode holders on OHAUS bench meters as well as electrode clips on all OHAUS portable meters.  Reference electrodes have a stable and well-defined electrochemical potential.  A measured potential in an electrochemical cell is determined against a defined potential value of a reference electrode.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eSpecifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDescription: Silver\/Silver Chloride (Ag\/AgCl)\u003c\/li\u003e\n\u003cli\u003eE vs. SHE (Standard Hydrogen Electrode) (V): 198\u003c\/li\u003e\n\u003cli\u003eConnector: 2 mm Banana\u003c\/li\u003e\n\u003cli\u003eDimensions (Shaft): 110 x 12mm\u003c\/li\u003e\n\u003cli\u003eCable Length: 1m\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cu\u003eCARE AND USE\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMaintenance of reference electrodes can help avoid stability problems and keep them in proper working condition.  Check that the reference electrode compartments are filled with electrolyte solution and the junction is not blocked.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/dmx.ohaus.com\/WorkArea\/showcontent.aspx?id=34016\" target=\"_blank\"\u003eStarter Series Electrodes Data Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/dmx.ohaus.com\/WorkArea\/showcontent.aspx?id=4294967518\" target=\"_blank\"\u003eSTREF1 Manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Ohaus","offers":[{"title":"Default Title","offer_id":238460370970,"sku":"STREF1","price":285.71,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/STREF1_DMX-ID_31446_WebShop.jpg?v=1630610093"},{"product_id":"ph-testing-stdo11","title":"Ohaus STDO11 Dissolved Oxygen Probe","description":"\u003cp style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cu data-mce-fragment=\"1\"\u003eOhaus STDO11 Dissolved Oxygen Probe \u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe OHAUS Starter Series are designed to produce exact results time and time again.  They fit perfectly in holders on OHAUS bench meters as well as clips on all OHAUS portable meters. \u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThere are three types of commonly used oxygen sensors: polarographic, galvanic and optical (luminescence) sensors.  STDO11 is a galvanic DO probe and the simplest among the three probes. \u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cu data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eConnection: BNC\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCable Length: 1m\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eShaft Length: 120 mm\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eShaft Diameter: 12 mm\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eShaft Material: Plastic\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTemperature Range: 0-50 ˚C\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMeasurement Range: 0-200%\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eStorage Solution: 10% NaCl\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cu data-mce-fragment=\"1\"\u003eCARE AND USE\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eCarefully remove the protective bottle from the tip of the electrode by unscrewing the lid and removing the bottle.  Remove the shorting plug from the connector and store in a safe place.  Be careful because the protective bottle lid is tightly fit on the electrode.  STDO11 should be stored in a moist environment to keep the membrane from drying out, but do not store directly in water.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eDO probes should be calibrated before being placed in the sample.  Before calibrating a probe, do not forget to remove water droplets from the membrane by gently shaking the sensor.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/dmx.ohaus.com\/WorkArea\/showcontent.aspx?id=34016\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eStarter Series Electrodes Data Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/dmx.ohaus.com\/WorkArea\/showcontent.aspx?id=29002\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eSTDO11 Manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Ohaus","offers":[{"title":"Default Title","offer_id":238460600346,"sku":"STD011","price":661.58,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/STDO11_DMX-ID_29434_WebShop.jpg?v=1631199577"},{"product_id":"ohaus-stcon7-low-conductivity-probe-canada","title":"Ohaus STCON7 Conductivity Probe","description":"\u003ch2\u003eOHAUS STCON7 Low Conductivity Probe\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eOHAUS STCON7 Conductivity Probe\u003c\/strong\u003e is a low-conductivity electrode designed for measuring samples such as \u003cstrong\u003epure water, distilled water, deionized water, and other low-conductivity laboratory solutions\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eUnlike general-purpose conductivity probes intended for higher conductivity samples, the STCON7 is built for the low µS\/cm range, with a measurement range of \u003cstrong\u003e0.02 to 200 µS\/cm\u003c\/strong\u003e. It uses a \u003cstrong\u003e2-pole potentiometric measuring method\u003c\/strong\u003e and includes automatic temperature compensation through its built-in temperature sensor.\u003c\/p\u003e\n\u003cdiv style=\"border: 1px solid #d9d9d9; padding: 18px; margin: 24px 0; border-radius: 8px; background: #f8f8f8;\"\u003e\n\u003ch3 style=\"margin-top: 0; font-size: 18px; line-height: 1.35;\"\u003eDesigned for Low Conductivity Water Testing\u003c\/h3\u003e\n\u003cul style=\"margin-bottom: 0;\"\u003e\n\u003cli\u003ePure water conductivity testing\u003c\/li\u003e\n\u003cli\u003eDistilled water and deionized water checks\u003c\/li\u003e\n\u003cli\u003eLaboratory water quality verification\u003c\/li\u003e\n\u003cli\u003eLow-conductivity process water testing\u003c\/li\u003e\n\u003cli\u003eResearch, quality control, environmental, education, and general laboratory use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eWhy Choose the OHAUS STCON7?\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow conductivity measurement range:\u003c\/strong\u003e Designed for 0.02 to 200 µS\/cm conductivity measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePure water application fit:\u003c\/strong\u003e Well suited for pure water, distilled water, and other low-conductivity sample types.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-pole potentiometric design:\u003c\/strong\u003e Built for conductivity measurement in the low µS\/cm range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic temperature compensation:\u003c\/strong\u003e Built-in temperature sensor supports temperature-compensated conductivity measurements when used with compatible OHAUS meters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMini-DIN connection:\u003c\/strong\u003e Designed for connection to compatible OHAUS Starter conductivity meters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e316L stainless steel measuring cell:\u003c\/strong\u003e Measuring cell chamber uses 316L stainless steel construction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact probe design:\u003c\/strong\u003e 95 mm shaft length and 12 mm shaft diameter for routine laboratory use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCanadian purchasing support:\u003c\/strong\u003e Supplied by Cambridge Environmental Products with CAD pricing and support for Canadian laboratories and facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOHAUS STCON7 Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 12px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eLow conductivity probe \/ conductivity electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eOHAUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eSTCON7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eOHAUS Item Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e30080693\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eMeasurement Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e2-pole potentiometric conductivity measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e0.02 to 200 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e0.02 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e0 to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eTemperature Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eAutomatic temperature compensation with built-in temperature sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eMini-DIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e1.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eShaft Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e95 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eShaft Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eShaft Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eABS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eCell Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e316L stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eCommon Applications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003ePure water, distilled water, deionized water, low-conductivity water, laboratory water quality checks, research, QC, and environmental testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eCompatible Meter Notes\u003c\/h2\u003e\n\u003cp\u003eThe STCON7 uses a Mini-DIN connection and is intended for use with compatible OHAUS Starter conductivity meters. OHAUS documentation identifies the STCON7 for use with the \u003cstrong\u003eStarter 300C\u003c\/strong\u003e and \u003cstrong\u003eStarter 3100C\u003c\/strong\u003e meters.\u003c\/p\u003e\n\u003cp\u003eBefore ordering, confirm that your meter accepts the STCON7 Mini-DIN conductivity electrode connection and supports the required low-conductivity measurement range for your application.\u003c\/p\u003e\n\u003ch2\u003eCare and Use Notes\u003c\/h2\u003e\n\u003cp\u003eFor best results, rinse the probe with distilled water between measurements to reduce carry-over from one solution to another. When measuring, make sure the solution is above the cell chamber and that the cell chamber is free of bubbles.\u003c\/p\u003e\n\u003cp\u003eAllow sufficient time for the probe to stabilize when measuring samples at different temperatures. If solids build up inside the cell chamber, carefully clean the chamber using a cotton swab soaked in detergent solution, then rinse the probe with distilled water.\u003c\/p\u003e\n\u003cp\u003eDo not expose the probe shaft to organic solvents during cleaning or measurement. Do not use the probe outside the recommended temperature range. Follow the OHAUS meter manual and your internal laboratory procedure for calibration and measurement.\u003c\/p\u003e\n\u003cdiv style=\"border: 1px solid #d9d9d9; padding: 18px; margin: 24px 0; border-radius: 8px; background: #fff8e5;\"\u003e\n\u003ch3 style=\"margin-top: 0; font-size: 18px; line-height: 1.35;\"\u003eLow Conductivity Probe Selection Note\u003c\/h3\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003eThe STCON7 is intended for low-conductivity measurements from 0.02 to 200 µS\/cm. If your samples are higher conductivity solutions, salt solutions, wastewater, process water, or general-purpose conductivity samples, another OHAUS conductivity probe may be a better fit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eCanadian Purchasing Support\u003c\/h2\u003e\n\u003cp\u003eCambridge Environmental Products supplies the OHAUS STCON7 Conductivity Probe in Canada with CAD pricing, Canadian purchasing support, and access to related OHAUS conductivity meters, electrodes, buffers, conductivity standards, and laboratory water testing supplies.\u003c\/p\u003e\n\u003ch2\u003eCommon Questions About the OHAUS STCON7 Conductivity Probe\u003c\/h2\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eWhat is the OHAUS STCON7 used for?\u003c\/h3\u003e\n\u003cp\u003eThe OHAUS STCON7 is used for low-conductivity measurement in samples such as pure water, distilled water, deionized water, and other low-conductivity laboratory solutions.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eWhat is the measurement range of the STCON7?\u003c\/h3\u003e\n\u003cp\u003eThe STCON7 measurement range is 0.02 to 200 µS\/cm.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eIs the STCON7 suitable for pure water testing?\u003c\/h3\u003e\n\u003cp\u003eYes. The STCON7 is specifically designed for low-conductivity measurements, including pure water and distilled water testing.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eDoes the STCON7 include temperature compensation?\u003c\/h3\u003e\n\u003cp\u003eYes. The STCON7 includes a built-in temperature sensor for automatic temperature compensation when used with a compatible OHAUS conductivity meter.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eWhat meters are compatible with the STCON7?\u003c\/h3\u003e\n\u003cp\u003eOHAUS documentation identifies the STCON7 for use with the Starter 300C and Starter 3100C conductivity meters. Confirm meter compatibility before ordering if you are using another OHAUS model.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eCan I use the STCON7 for general high-conductivity samples?\u003c\/h3\u003e\n\u003cp\u003eThe STCON7 is intended for low-conductivity measurements from 0.02 to 200 µS\/cm. For higher-conductivity samples, another OHAUS conductivity probe may be more appropriate.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eHow should I clean the STCON7?\u003c\/h3\u003e\n\u003cp\u003eRinse the probe with distilled water between and after measurements. If solids build up in the measuring cell chamber, clean carefully with a cotton swab soaked in detergent solution, then rinse with distilled water. Do not expose the shaft to organic solvents.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eWhere can I buy the OHAUS STCON7 in Canada?\u003c\/h3\u003e\n\u003cp\u003eCambridge Environmental Products supplies the OHAUS STCON7 Conductivity Probe in Canada with CAD pricing and Canadian purchasing support for laboratories, water testing facilities, schools, research teams, and QC labs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration-line: underline;\"\u003e\u003cbr\u003eAvailable Literature:\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e \u003ca rel=\"noopener\" href=\"https:\/\/dmx.ohaus.com\/WorkArea\/showcontent.aspx?id=4294967519\" target=\"_blank\"\u003eOHAUS Starter Series Electrodes Data Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca rel=\"noopener\" href=\"https:\/\/dmx.ohaus.com\/WorkArea\/showcontent.aspx?id=34016\" target=\"_blank\"\u003eOHAUS STCON7 Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv style=\"border: 1px solid #d9d9d9; padding: 22px; margin-top: 32px; border-radius: 8px; background: #f8f8f8;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eNeed Help Choosing an OHAUS Conductivity Probe?\u003c\/h2\u003e\n\u003cp\u003eNot sure if the STCON7 is the right conductivity probe for your water testing workflow? Cambridge Environmental Products can help Canadian buyers compare OHAUS conductivity probes, compatible meters, conductivity standards, and related water analysis supplies.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContact us before ordering if you need help confirming meter compatibility, measurement range, or the correct probe for your sample type.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003ca style=\"display: inline-block; padding: 12px 18px; background: #1f4e79; color: #ffffff; text-decoration: none; border-radius: 5px; font-weight: bold;\" href=\"\/pages\/contact\"\u003e Contact Cambridge for OHAUS Conductivity Support \u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Ohaus","offers":[{"title":"Default Title","offer_id":238462140442,"sku":"STCON7","price":982.59,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/STCON7_DMX-ID_4294967702_WebShop.jpg?v=1631199378"},{"product_id":"products-ohaus-stcon3-4-ring-conductivity-electrode-canada","title":"Ohaus STCON3 Conductivity Probe","description":"\u003ch2\u003eOHAUS STCON3 4-Ring Conductivity Electrode\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eOHAUS STCON3 Conductivity Electrode\u003c\/strong\u003e is a broad-range \u003cstrong\u003e4-ring conductivity probe\u003c\/strong\u003e designed for use with compatible OHAUS Starter water analysis meters.\u003c\/p\u003e\n\u003cp\u003eWith a measurement range of \u003cstrong\u003e2 µS\/cm to 200 mS\/cm\u003c\/strong\u003e, the STCON3 is well suited for Canadian laboratories and facilities testing conductivity in water, wastewater, environmental samples, food and beverage workflows, brewing, education, research, and general quality control applications.\u003c\/p\u003e\n\u003cdiv style=\"border: 1px solid #d9d9d9; padding: 18px; margin: 24px 0; border-radius: 8px; background: #f8f8f8;\"\u003e\n\u003ch3 style=\"margin-top: 0; font-size: 18px; line-height: 1.35;\"\u003eDesigned for Broad-Range Conductivity Testing\u003c\/h3\u003e\n\u003cul style=\"margin-bottom: 0;\"\u003e\n\u003cli\u003eWastewater and environmental water testing\u003c\/li\u003e\n\u003cli\u003eFood and beverage quality control\u003c\/li\u003e\n\u003cli\u003eBrewing, production, and process water checks\u003c\/li\u003e\n\u003cli\u003eLaboratory conductivity measurement\u003c\/li\u003e\n\u003cli\u003eEducation, research, and routine water analysis workflows\u003c\/li\u003e\n\u003cli\u003eCanadian labs using compatible OHAUS Starter conductivity meters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eWhy Choose the OHAUS STCON3?\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-ring conductivity design:\u003c\/strong\u003e Uses a four-ring measuring design for broad-range conductivity measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide measurement range:\u003c\/strong\u003e Measures from 2 µS\/cm to 200 mS\/cm, covering many routine lab and field conductivity applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic temperature compensation:\u003c\/strong\u003e Built-in temperature sensor supports temperature-compensated conductivity readings when used with a compatible OHAUS meter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUseful for many sample types:\u003c\/strong\u003e Suitable for routine water, wastewater, process water, environmental, food, beverage, and QC conductivity workflows.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlastic shaft construction:\u003c\/strong\u003e Durable probe body for routine laboratory and portable meter use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible with multiple OHAUS meters:\u003c\/strong\u003e Designed for use with select OHAUS Starter and AquaSearcher meter platforms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCanadian purchasing support:\u003c\/strong\u003e Supplied by Cambridge Environmental Products with CAD pricing and support for Canadian laboratories and facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOHAUS STCON3 Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 12px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e4-ring conductivity electrode \/ conductivity probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eOHAUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eSTCON3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eCambridge SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eSTCON3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eOHAUS Item Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e83033972\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eElectrode Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eConductivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e2 µS\/cm to 200 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e0°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eTemperature Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eAutomatic temperature compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eTemperature Sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e30 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e1.1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eShaft Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003ePlastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e135 mm x 15 mm \/ 5.3 in x 0.59 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e85 g \/ 3 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eWorking Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e10°C to 40°C, 85% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eCommon Applications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eWater analysis, wastewater, environmental testing, food and beverage QC, brewing, process water, education, research, and routine laboratory conductivity measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eCompatible OHAUS Meters\u003c\/h2\u003e\n\u003cp\u003eOHAUS lists the STCON3 as applicable for use with the following compatible meter platforms:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOHAUS ST300C\u003c\/li\u003e\n\u003cli\u003eOHAUS ST400M\u003c\/li\u003e\n\u003cli\u003eOHAUS AB23EC\u003c\/li\u003e\n\u003cli\u003eOHAUS AB33EC\u003c\/li\u003e\n\u003cli\u003eOHAUS AB33M1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBefore ordering, confirm that your meter accepts the STCON3 electrode connection and supports the conductivity range required for your application.\u003c\/p\u003e\n\u003ch2\u003eSTCON3 vs STCON7 Selection Note\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eOHAUS STCON3\u003c\/strong\u003e is the better fit for broad-range conductivity testing, including many routine water, wastewater, environmental, food, beverage, and QC samples.\u003c\/p\u003e\n\u003cp\u003eIf your application is focused on very low-conductivity samples such as pure water, distilled water, or deionized water, the \u003cstrong\u003eOHAUS STCON7 Low Conductivity Probe\u003c\/strong\u003e may be a better choice. Contact Cambridge before ordering if you are unsure which OHAUS conductivity probe is correct for your sample range.\u003c\/p\u003e\n\u003ch2\u003eCare and Use Notes\u003c\/h2\u003e\n\u003cp\u003eFor best results, keep the plastic shield in place during measurement and make sure the solution reaches the correct level on the shield while remaining below the vent hole.\u003c\/p\u003e\n\u003cp\u003eRinse the probe with distilled water between and after measurements to reduce carry-over, especially when moving from high-conductivity samples to lower-conductivity samples.\u003c\/p\u003e\n\u003cp\u003eMake sure the cell chamber is bubble-free during measurement. Allow sufficient time for the sensor to stabilize when measuring samples at different temperatures. Follow the OHAUS meter manual and your internal laboratory procedure for calibration, measurement, cleaning, and storage.\u003c\/p\u003e\n\u003cdiv style=\"border: 1px solid #d9d9d9; padding: 18px; margin: 24px 0; border-radius: 8px; background: #fff8e5;\"\u003e\n\u003ch3 style=\"margin-top: 0; font-size: 18px; line-height: 1.35;\"\u003eConductivity Probe Selection Note\u003c\/h3\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003eConductivity probe selection depends on your expected measurement range, sample type, meter compatibility, temperature conditions, and laboratory procedure. If you are testing very low-conductivity water, high-conductivity salt solutions, wastewater, food process samples, or production water, confirm the correct probe and standard before ordering.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eCanadian Purchasing Support\u003c\/h2\u003e\n\u003cp\u003eCambridge Environmental Products supplies the OHAUS STCON3 Conductivity Electrode in Canada with CAD pricing, Canadian purchasing support, and access to related OHAUS meters, conductivity standards, pH meters, electrodes, buffers, and water testing supplies.\u003c\/p\u003e\n\u003ch2\u003eCommon Questions About the OHAUS STCON3 Conductivity Electrode\u003c\/h2\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eWhat is the OHAUS STCON3 used for?\u003c\/h3\u003e\n\u003cp\u003eThe OHAUS STCON3 is used for broad-range conductivity measurement in water, wastewater, environmental, food and beverage, brewing, education, research, and quality control applications.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eWhat is the measurement range of the STCON3?\u003c\/h3\u003e\n\u003cp\u003eThe STCON3 measurement range is 2 µS\/cm to 200 mS\/cm.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eIs the STCON3 a 4-ring conductivity electrode?\u003c\/h3\u003e\n\u003cp\u003eYes. The STCON3 is a 4-ring conductivity electrode designed for broad-range conductivity measurement.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eDoes the STCON3 include temperature compensation?\u003c\/h3\u003e\n\u003cp\u003eYes. The STCON3 includes automatic temperature compensation when used with a compatible OHAUS meter.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eWhich meters are compatible with the STCON3?\u003c\/h3\u003e\n\u003cp\u003eOHAUS lists the STCON3 as applicable for ST300C, ST400M, AB23EC, AB33EC, and AB33M1 meters. Confirm compatibility before ordering if you are using another OHAUS meter.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eIs the STCON3 suitable for wastewater testing?\u003c\/h3\u003e\n\u003cp\u003eYes, the STCON3 can be suitable for many routine wastewater and environmental conductivity testing workflows, provided the expected conductivity range and meter setup match the application.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eIs the STCON3 suitable for pure water testing?\u003c\/h3\u003e\n\u003cp\u003eThe STCON3 can measure down to 2 µS\/cm, but for very low-conductivity pure water, distilled water, or deionized water testing, the OHAUS STCON7 may be a better fit.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eHow should I clean the STCON3?\u003c\/h3\u003e\n\u003cp\u003eRinse the probe with distilled water between and after measurements. Make sure the cell chamber is free of bubbles and follow the OHAUS meter manual and internal laboratory procedure for cleaning and storage.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eWhere can I buy the OHAUS STCON3 in Canada?\u003c\/h3\u003e\n\u003cp\u003eCambridge Environmental Products supplies the OHAUS STCON3 Conductivity Electrode in Canada with CAD pricing and Canadian purchasing support for laboratories, schools, wastewater facilities, environmental testing teams, food and beverage producers, breweries, and QC labs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration-line: underline;\"\u003e\u003cbr\u003eAvailable Literature:\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e \u003ca rel=\"noopener\" href=\"https:\/\/us.ohaus.com\/en-us\/products\/instruments-equipment\/water-analysis\/starter-electrodes\/4-ring-conductivity-electrode-stcon3\" target=\"_blank\"\u003eOHAUS STCON3 Product Information\u003c\/a\u003e\u003cbr\u003e\u003ca rel=\"noopener\" href=\"https:\/\/dmx.ohaus.com\/WorkArea\/showcontent.aspx?id=4294967519\" target=\"_blank\"\u003eOHAUS Starter Series Electrodes Data Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv style=\"border: 1px solid #d9d9d9; padding: 22px; margin-top: 32px; border-radius: 8px; background: #f8f8f8;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eNeed Help Choosing an OHAUS Conductivity Probe?\u003c\/h2\u003e\n\u003cp\u003eNot sure if the STCON3 is the right conductivity probe for your workflow? Cambridge Environmental Products can help Canadian buyers compare OHAUS conductivity probes, compatible meters, conductivity standards, and related water analysis supplies.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContact us before ordering if you need help confirming meter compatibility, measurement range, or the correct probe for your sample type.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003ca style=\"display: inline-block; padding: 12px 18px; background: #1f4e79; color: #ffffff; text-decoration: none; border-radius: 5px; font-weight: bold;\" href=\"\/pages\/contact\"\u003e Contact Cambridge for OHAUS Conductivity Support \u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Ohaus","offers":[{"title":"Default Title","offer_id":238463909914,"sku":"STCON3","price":554.19,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/STCON3_DMX-ID_31436_WebShop.jpg?v=1631211637"},{"product_id":"ph-testing-stsurf","title":"Ohaus STSURF 2-in-1 Plastic Refillable pH Electrode","description":"\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cu\u003eOhaus STSURF 2-in-1 Plastic Flat Refillable pH Electrode \u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe OHAUS Starter Series of electrodes are designed to produce exact results time and time again.  They fit perfectly in the electrode holders on OHAUS bench meters as well as electrode clips on all OHAUS portable meters.  This electrode is suitable for flat surface applications, such as skin, paper, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eSpecifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003epH Range: 2 to 12\u003c\/li\u003e\n\u003cli\u003eTemperature Range: 0 to 80 ºC\u003c\/li\u003e\n\u003cli\u003eShaft Material: Plastic\u003c\/li\u003e\n\u003cli\u003eInternal Reference Type: Ag\/AgCl\u003c\/li\u003e\n\u003cli\u003eRefillable\/Non-refillable: Refillable\u003c\/li\u003e\n\u003cli\u003eReference Junction Type: Ground glass\u003c\/li\u003e\n\u003cli\u003eRefilling Reference Electrolyte: 3M KCl solution\u003c\/li\u003e\n\u003cli\u003eDimensions (Shaft): 120 x 12mm\u003c\/li\u003e\n\u003cli\u003eCable Length: 1m\u003c\/li\u003e\n\u003cli\u003eTemperature Sensor: No\u003c\/li\u003e\n\u003cli\u003eConnector: BNC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cu\u003eCARE AND USE\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis delicate instrument requires proper care and maintenance to produce accurate, reliable results and to ensure a long, usable life.\u003c\/p\u003e\n\u003cp\u003eExtend the life of your pH electrode in the following ways:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAlways keep the electrode moist when not in use by placing it in an electrode storage solution (3M KCl).\u003c\/li\u003e\n\u003cli\u003eDO NOT store the electrode in distilled or deionized water, as this will cause ions to leak out of the glass bulb and reference electrolyte. This will produce a slow and sluggish response and can damage the electrode. \u003c\/li\u003e\n\u003cli\u003eRemove the electrode gently from the storage bottle and rinse it with distilled water before use.\u003c\/li\u003e\n\u003cli\u003eFor long-term storage, always keep the electrode in the bottle filled with enough storage solution to cover the bulb. Replenish the bottle as needed.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eStarter Series Electrodes Data Sheet\u003cbr\u003eSTSURF Manual\u003c\/p\u003e","brand":"Ohaus","offers":[{"title":"Default Title","offer_id":238463975450,"sku":"STSURF","price":312.56,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/STSURF.jpg?v=1630511616"},{"product_id":"ph-testing-st320","title":"Ohaus ST320 Plastic pH Electrode","description":"\u003cp style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cu data-mce-fragment=\"1\"\u003eOhaus ST320 Plastic Non-Refillable pH Electrode \u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe OHAUS Starter Series of electrodes are designed to produce exact results time and time again.  They fit perfectly in the electrode holders on OHAUS bench meters as well as electrode clips on all OHAUS portable meters.  This electrode has an integrated temperature probe and is suitable for standard or muddy samples.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cu data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003epH Range: 0 to 13\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTemperature Range: 0 to 80 ºC\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eShaft Material: Plastic\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eInternal Reference Type: Ag\/AgCl\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRefillable\/Non-refillable: Non-refillable, gel\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eReference Junction Type: Fiber pin\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRefilling Reference Electrolyte: 3M KCl solution\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDimensions (Shaft): 120 x 12mm\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCable Length: 1m\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTemperature Sensor: Yes\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eConnector: BNC Cinch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cu data-mce-fragment=\"1\"\u003eCARE AND USE\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis delicate instrument requires proper care and maintenance to produce accurate, reliable results and to ensure a long, usable life.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eExtend the life of your pH electrode in the following ways:\u003c\/p\u003e\n\u003col data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAlways keep the electrode moist when not in use by placing it in an electrode storage solution (3M KCl).\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDO NOT store the electrode in distilled or deionized water, as this will cause ions to leak out of the glass bulb and reference electrolyte. This will produce a slow and sluggish response and can damage the electrode. \u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRemove the electrode gently from the storage bottle and rinse it with distilled water before use.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFor long-term storage, always keep the electrode in the bottle filled with enough storage solution to cover the bulb. Replenish the bottle as needed.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/dmx.ohaus.com\/WorkArea\/showcontent.aspx?id=34016\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eStarter Series Electrodes Data Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/dmx.ohaus.com\/WorkArea\/showcontent.aspx?id=4294967516\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eST320 Manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Ohaus","offers":[{"title":"Default Title","offer_id":238464139290,"sku":"ST320","price":287.69,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/ST320.jpg?v=1630509797"},{"product_id":"ph-testing-st310","title":"Ohaus ST310 Plastic Refillable pH Electrode","description":"\u003cp style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cu data-mce-fragment=\"1\"\u003eOhaus ST310 3-in-1 Plastic Refillable pH Electrode\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe OHAUS Starter Series of electrodes are designed to produce exact results time and time again.  They fit perfectly in the electrode holders on OHAUS bench meters as well as electrode clips on all OHAUS portable meters.  This electrode is suitable for normal samples.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cu data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003epH Range: 0 to 14\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTemperature Range: 0 to 80 ºC\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eShaft Material: Plastic\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eInternal Reference Type: Ag\/AgCl\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRefillable\/Non-refillable: Refillable\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eReference Junction Type: Ceramic pin\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRefilling Reference Electrolyte: 3M KCl solution\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDimensions (Shaft): 120 x 12mm\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCable Length: 1m\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTemperature Sensor: Yes\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eConnector: BNC Cinch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cu data-mce-fragment=\"1\"\u003eCARE AND USE\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis delicate instrument requires proper care and maintenance to produce accurate, reliable results and to ensure a long, usable life.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eExtend the life of your pH electrode in the following ways:\u003c\/p\u003e\n\u003col data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAlways keep the electrode moist when not in use by placing it in an electrode storage solution (3M KCl).\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDO NOT store the electrode in distilled or deionized water, as this will cause ions to leak out of the glass bulb and reference electrolyte. This will produce a slow and sluggish response and can damage the electrode. \u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRemove the electrode gently from the storage bottle and rinse it with distilled water before use.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFor long-term storage, always keep the electrode in the bottle filled with enough storage solution to cover the bulb. Replenish the bottle as needed.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/dmx.ohaus.com\/WorkArea\/showcontent.aspx?id=34016\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eStarter Series Electrodes Data Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/dmx.ohaus.com\/WorkArea\/showcontent.aspx?id=4294967516\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eST310 Manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Ohaus","offers":[{"title":"Default Title","offer_id":238464204826,"sku":"ST310","price":279.88,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/ST310.jpg?v=1630508821"},{"product_id":"ph-testing-st210","title":"Ohaus ST210 2-in-1 Plastic Refillable pH Electrode","description":"\u003cp style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cu data-mce-fragment=\"1\"\u003eOhaus ST210 2-in-1 Plastic Refillable pH Electrode\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe OHAUS Starter Series of electrodes are designed to produce exact results time and time again.  They fit perfectly in the electrode holders on OHAUS bench meters as well as electrode clips on all OHAUS portable meters.  This electrode is suitable for normal samples. \u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cu data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003epH Range: 0 to 14\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTemperature Range: 0 to 80 ºC\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eShaft Material: Plastic\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eInternal Reference Type: Ag\/AgCl\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRefillable\/Non-refillable: Refillable\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eReference Junction Type: Ceramic pin\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRefilling Reference Electrolyte: 3M KCl solution\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDimensions (Shaft): 120 x 12mm\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCable Length: 1m\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTemperature Sensor: No\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eConnector: BNC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cu data-mce-fragment=\"1\"\u003eCARE AND USE\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis delicate instrument requires proper care and maintenance to produce accurate, reliable results and to ensure a long, usable life.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eExtend the life of your pH electrode in the following ways:\u003c\/p\u003e\n\u003col data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAlways keep the electrode moist when not in use by placing it in an electrode storage solution (3M KCl).\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDO NOT store the electrode in distilled or deionized water, as this will cause ions to leak out of the glass bulb and reference electrolyte. This will produce a slow and sluggish response and can damage the electrode. \u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRemove the electrode gently from the storage bottle and rinse it with distilled water before use.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFor long-term storage, always keep the electrode in the bottle filled with enough storage solution to cover the bulb. Replenish the bottle as needed.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/dmx.ohaus.com\/WorkArea\/showcontent.aspx?id=34016\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eStarter Series Electrodes Data Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/dmx.ohaus.com\/WorkArea\/showcontent.aspx?id=4294967516\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eST210 Manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Ohaus","offers":[{"title":"Default Title","offer_id":238464270362,"sku":"ST210","price":146.8,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/ST210.jpg?v=1630504485"},{"product_id":"ph-testing-stpure","title":"Ohaus STPURE Glass Refillable pH Electrode","description":"\u003cp style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cu data-mce-fragment=\"1\"\u003eOhaus STPURE Glass Refillable Pure Water Sample pH Electrode\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe OHAUS Starter Series of electrodes are designed to produce exact results time and time again.  They fit perfectly in the electrode holders on OHAUS bench meters as well as electrode clips on all OHAUS portable meters.  This electrode is suitable for pure water (distilled water, rain water, tap water, etc.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cu data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003epH Range: 0 to 13\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTemperature Range: 0 to 100 ºC\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eShaft Material: Glass\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eInternal Reference Type: Ag\/AgCl\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRefillable\/Non-refillable: Refillable\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eReference Junction Type: Ground glass\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRefilling Reference Electrolyte: 3M KCl solution\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDimensions (Shaft): 120 x 12mm\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCable Length: 1m\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTemperature Sensor: No\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eConnector: BNC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cu data-mce-fragment=\"1\"\u003eCARE AND USE\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis delicate instrument requires proper care and maintenance to produce accurate, reliable results and to ensure a long, usable life.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eExtend the life of your pH electrode in the following ways:\u003c\/p\u003e\n\u003col data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAlways keep the electrode moist when not in use by placing it in an electrode storage solution (3M KCl).\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDO NOT store the electrode in distilled or deionized water, as this will cause ions to leak out of the glass bulb and reference electrolyte. This will produce a slow and sluggish response and can damage the electrode. \u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRemove the electrode gently from the storage bottle and rinse it with distilled water before use.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFor long-term storage, always keep the electrode in the bottle filled with enough storage solution to cover the bulb. Replenish the bottle as needed.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/dmx.ohaus.com\/WorkArea\/showcontent.aspx?id=34016\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eStarter Series Electrodes Data Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/dmx.ohaus.com\/WorkArea\/showcontent.aspx?id=4294967516\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eSTPURE Manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Ohaus","offers":[{"title":"Default Title","offer_id":238464368666,"sku":"STPURE","price":269.37,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/STPURE.jpg?v=1630508282"},{"product_id":"ph-testing-stmicro5","title":"Ohaus STMICRO5 2-in-1 Glass Micro Sample Refillable pH Electrode","description":"\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cu\u003eOhaus STMICRO5 2-in-1 Glass Micro Sample Refillable pH Electrode, 80mm x 5mm \u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe OHAUS Starter Series of electrodes are designed to produce exact results time and time again.  They fit perfectly in the electrode holders on OHAUS bench meters as well as electrode clips on all OHAUS portable meters.  This electrode is suitable for small samples, tubes, and narrow containers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eSpecifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003epH Range: 0 to 14\u003c\/li\u003e\n\u003cli\u003eTemperature Range: 0 to 100 ºC\u003c\/li\u003e\n\u003cli\u003eShaft Material: Glass\u003c\/li\u003e\n\u003cli\u003eInternal Reference Type: Ag\/AgCl\u003c\/li\u003e\n\u003cli\u003eRefillable\/Non-refillable: Refillable\u003c\/li\u003e\n\u003cli\u003eReference Junction Type: Annular ceramic\u003c\/li\u003e\n\u003cli\u003eRefilling Reference Electrolyte: 3M KCl solution\u003c\/li\u003e\n\u003cli\u003eDimensions (Shaft): 80 x 5mm\u003c\/li\u003e\n\u003cli\u003eCable Length: 1m\u003c\/li\u003e\n\u003cli\u003eTemperature Sensor: No\u003c\/li\u003e\n\u003cli\u003eConnector: BNC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cu\u003eCARE AND USE\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis delicate instrument requires proper care and maintenance to produce accurate, reliable results and to ensure a long, usable life.\u003c\/p\u003e\n\u003cp\u003eExtend the life of your pH electrode in the following ways:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAlways keep the electrode moist when not in use by placing it in an electrode storage solution (3M KCl).\u003c\/li\u003e\n\u003cli\u003eDO NOT store the electrode in distilled or deionized water, as this will cause ions to leak out of the glass bulb and reference electrolyte. This will produce a slow and sluggish response and can damage the electrode. \u003c\/li\u003e\n\u003cli\u003eRemove the electrode gently from the storage bottle and rinse it with distilled water before use.\u003c\/li\u003e\n\u003cli\u003eFor long-term storage, always keep the electrode in the bottle filled with enough storage solution to cover the bulb. Replenish the bottle as needed.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/dmx.ohaus.com\/WorkArea\/showcontent.aspx?id=34016\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eStarter Series Electrodes Data Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/dmx.ohaus.com\/WorkArea\/showcontent.aspx?id=4294967521\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eSTMICRO5 Manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Ohaus","offers":[{"title":"Default Title","offer_id":238464499738,"sku":"STMICRO5","price":468.98,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/STMICRO5.jpg?v=1630606575"},{"product_id":"ph-testing-st350","title":"Ohaus ST350 3-in-1 Glass Refillable pH Electrode","description":"\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cu\u003eOhaus ST350 3-in-1 Glass Refillable pH Electrode with Integrated Temperature Probe \u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe OHAUS Starter Series of electrodes are designed to produce exact results time and time again.  They fit perfectly in the electrode holders on OHAUS bench meters as well as electrode clips on all OHAUS portable meters.  This electrode is suitable for normal samples.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eSpecifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003epH Range: 0 to 14\u003c\/li\u003e\n\u003cli\u003eTemperature Range: 0 to 100 ºC\u003c\/li\u003e\n\u003cli\u003eShaft Material: Glass\u003c\/li\u003e\n\u003cli\u003eInternal Reference Type: Ag\/AgCl\u003c\/li\u003e\n\u003cli\u003eRefillable\/Non-refillable: Refillable\u003c\/li\u003e\n\u003cli\u003eReference Junction Type: Annular ceramic\u003c\/li\u003e\n\u003cli\u003eRefilling Reference Electrolyte: 3M KCl solution\u003c\/li\u003e\n\u003cli\u003eDimensions (Shaft): 120 x 12mm\u003c\/li\u003e\n\u003cli\u003eCable Length: 1m\u003c\/li\u003e\n\u003cli\u003eTemperature Sensor: Yes\u003c\/li\u003e\n\u003cli\u003eConnector: BNC Cinch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cu\u003eCARE AND USE\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis delicate instrument requires proper care and maintenance to produce accurate, reliable results and to ensure a long, usable life.\u003c\/p\u003e\n\u003cp\u003eExtend the life of your pH electrode in the following ways:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAlways keep the electrode moist when not in use by placing it in an electrode storage solution (3M KCl).\u003c\/li\u003e\n\u003cli\u003eDO NOT store the electrode in distilled or deionized water, as this will cause ions to leak out of the glass bulb and reference electrolyte. This will produce a slow and sluggish response and can damage the electrode. \u003c\/li\u003e\n\u003cli\u003eRemove the electrode gently from the storage bottle and rinse it with distilled water before use.\u003c\/li\u003e\n\u003cli\u003eFor long-term storage, always keep the electrode in the bottle filled with enough storage solution to cover the bulb. Replenish the bottle as needed.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/dmx.ohaus.com\/WorkArea\/showcontent.aspx?id=34016\" target=\"_blank\"\u003eStarter Series Electrodes Data Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/dmx.ohaus.com\/WorkArea\/showcontent.aspx?id=4294969228\" target=\"_blank\"\u003eST350 Manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Ohaus","offers":[{"title":"Default Title","offer_id":238464565274,"sku":"ST350","price":338.24,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/ST350_Vertical_DMX-ID_4294968705_WebShop.jpg?v=1630609454"},{"product_id":"ph-testing-st270","title":"Ohaus ST270 2-in-1 Glass Puncture pH Electrode","description":"\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cu\u003eOhaus ST270 2-in-1 Glass Puncture Non-refillable pH Electrode \u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe OHAUS Starter Series of electrodes are designed to produce exact results time and time again.  They fit perfectly in the electrode holders on OHAUS bench meters as well as electrode clips on all OHAUS portable meters.  This electrode is suitable for semi-solid samples such as fruits, meat or cheese.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eSpecifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003epH Range: 0 to 14\u003c\/li\u003e\n\u003cli\u003eTemperature Range: 0 to 100 ºC\u003c\/li\u003e\n\u003cli\u003eShaft Material: Glass\u003c\/li\u003e\n\u003cli\u003eInternal Reference Type: Ag\/AgCl\u003c\/li\u003e\n\u003cli\u003eRefillable\/Non-refillable: Non-refillable, gel\u003c\/li\u003e\n\u003cli\u003eReference Junction Type: Annular ceramic\u003c\/li\u003e\n\u003cli\u003eRefilling Reference Electrolyte: 3M KCl gel\u003c\/li\u003e\n\u003cli\u003eDimensions (Shaft): 120 x 12mm\u003c\/li\u003e\n\u003cli\u003eCable Length: 1m\u003c\/li\u003e\n\u003cli\u003eTemperature Sensor: No\u003c\/li\u003e\n\u003cli\u003eConnector: BNC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cu\u003eCARE AND USE\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis delicate instrument requires proper care and maintenance to produce accurate, reliable results and to ensure a long, usable life.\u003c\/p\u003e\n\u003cp\u003eExtend the life of your pH electrode in the following ways:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAlways keep the electrode moist when not in use by placing it in an electrode storage solution (3M KCl).\u003c\/li\u003e\n\u003cli\u003eDO NOT store the electrode in distilled or deionized water, as this will cause ions to leak out of the glass bulb and reference electrolyte. This will produce a slow and sluggish response and can damage the electrode. \u003c\/li\u003e\n\u003cli\u003eRemove the electrode gently from the storage bottle and rinse it with distilled water before use.\u003c\/li\u003e\n\u003cli\u003eFor long-term storage, always keep the electrode in the bottle filled with enough storage solution to cover the bulb. Replenish the bottle as needed.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/dmx.ohaus.com\/WorkArea\/showcontent.aspx?id=34016\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eStarter Series Electrodes Data Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/dmx.ohaus.com\/WorkArea\/showcontent.aspx?id=4294972056\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eST270 Manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Ohaus","offers":[{"title":"Default Title","offer_id":238464663578,"sku":"ST270","price":539.02,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/ST270.jpg?v=1630608337"},{"product_id":"ph-testing-st260","title":"Ohaus ST260 2-in-1 Glass Refillable pH Electrode","description":"\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cu\u003eOhaus ST260 2-in-1 Double Salt Bridge Glass Refillable pH Electrode \u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe OHAUS Starter Series of electrodes are designed to produce exact results time and time again.  They fit perfectly in the electrode holders on OHAUS bench meters as well as electrode clips on all OHAUS portable meters.  This electrode is suitable for samples which may react with Ag ions, such as trisbuffer solution.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eSpecifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003epH Range: 0 to 14\u003c\/li\u003e\n\u003cli\u003eTemperature Range: 0 to 100 ºC\u003c\/li\u003e\n\u003cli\u003eShaft Material: Glass\u003c\/li\u003e\n\u003cli\u003eInternal Reference Type: Ag\/AgCl\u003c\/li\u003e\n\u003cli\u003eRefillable\/Non-refillable: Refillable\u003c\/li\u003e\n\u003cli\u003eReference Junction Type: Ceramic pin\u003c\/li\u003e\n\u003cli\u003eRefilling Reference Electrolyte: Double salt-bridge 3M KCl(AgCl) Pure KCl solution\u003c\/li\u003e\n\u003cli\u003eDimensions (Shaft): 120 x 12mm\u003c\/li\u003e\n\u003cli\u003eCable Length: 1m\u003c\/li\u003e\n\u003cli\u003eTemperature Sensor: No\u003c\/li\u003e\n\u003cli\u003eConnector: BNC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cu\u003eCARE AND USE\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis delicate instrument requires proper care and maintenance to produce accurate, reliable results and to ensure a long, usable life.\u003c\/p\u003e\n\u003cp\u003eExtend the life of your pH electrode in the following ways:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAlways keep the electrode moist when not in use by placing it in an electrode storage solution (3M KCl).\u003c\/li\u003e\n\u003cli\u003eDO NOT store the electrode in distilled or deionized water, as this will cause ions to leak out of the glass bulb and reference electrolyte. This will produce a slow and sluggish response and can damage the electrode. \u003c\/li\u003e\n\u003cli\u003eRemove the electrode gently from the storage bottle and rinse it with distilled water before use.\u003c\/li\u003e\n\u003cli\u003eFor long-term storage, always keep the electrode in the bottle filled with enough storage solution to cover the bulb. Replenish the bottle as needed.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/dmx.ohaus.com\/WorkArea\/showcontent.aspx?id=34016\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eStarter Series Electrodes Data Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/dmx.ohaus.com\/WorkArea\/showcontent.aspx?id=4294969230\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eST260 Manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Ohaus","offers":[{"title":"Default Title","offer_id":238464729114,"sku":"ST260","price":318.4,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/ST.jpg?v=1630511860"},{"product_id":"ph-testing-st230","title":"Ohaus ST230 2-in-1 Glass Refillable pH Electrode","description":"\u003cp data-mce-fragment=\"1\" style=\"text-align: center;\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cu data-mce-fragment=\"1\"\u003eOhaus ST230 2-in-1 Glass Refillable Muddy Sample pH Electrode\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe OHAUS Starter Series of electrodes are designed to produce exact results time and time again.  They fit perfectly in the electrode holders on OHAUS bench meters as well as electrode clips on all OHAUS portable meters.  This probe is suitable for muddy samples such as milk and juice.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cu data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003epH Range: 0 to 14\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTemperature Range: 0 to 100 ºC\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eShaft Material: Glass\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eInternal Reference Type: Ag\/AgCl\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRefillable\/Non-refillable: Refillable\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eReference Junction Type: Annular ceramic\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRefilling Reference Electrolyte: 3M KCl solution\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDimensions (Shaft): 110 x 12mm\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCable Length: 1m\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTemperature Sensor: No\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eConnector: BNC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\" style=\"text-align: center;\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cu data-mce-fragment=\"1\"\u003eCARE AND USE\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis delicate instrument requires proper care and maintenance to produce accurate, reliable results and to ensure a long, usable life.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eExtend the life of your pH electrode in the following ways:\u003c\/p\u003e\n\u003col data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAlways keep the electrode moist when not in use by placing it in an electrode storage solution (3M KCl).\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDO NOT store the electrode in distilled or deionized water, as this will cause ions to leak out of the glass bulb and reference electrolyte. This will produce a slow and sluggish response and can damage the electrode. \u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRemove the electrode gently from the storage bottle and rinse it with distilled water before use.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFor long-term storage, always keep the electrode in the bottle filled with enough storage solution to cover the bulb. Replenish the bottle as needed.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/dmx.ohaus.com\/WorkArea\/showcontent.aspx?id=34016\" target=\"_blank\"\u003eStarter Series Electrodes Data Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/dmx.ohaus.com\/WorkArea\/showcontent.aspx?id=4294967516\" target=\"_blank\"\u003eST230 Manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Ohaus","offers":[{"title":"Default Title","offer_id":238464892954,"sku":"ST230","price":247.19,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/ST230.jpg?v=1630506304"},{"product_id":"ohaus-st320-ip67-3m-plastic-ph-electrode","title":"Ohaus ST320 IP67 3M Plastic pH Electrode","description":"\u003cp data-mce-fragment=\"1\" style=\"text-align: center;\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cu data-mce-fragment=\"1\"\u003eOhaus ST320 IP67 3M Plastic Non-Refillable pH Electrode \u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe OHAUS Starter Series of electrodes are designed to produce exact results time and time again.  They fit perfectly in the electrode holders on OHAUS bench meters as well as electrode clips on all OHAUS portable meters.  This electrode has a IP67 connector and a 3 meter cable.  It is compatible with ST400\/400M IP67 waterproof portable meter.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cu data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003epH Range: 0 to 13\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTemperature Range: 0 to 80 ºC\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eShaft Material: Plastic\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eInternal Reference Type: Ag\/AgCl\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRefillable\/Non-refillable: Non-refillable, gel\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eReference Junction Type: Fiber pin\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRefilling Reference Electrolyte: 3M KCl solution\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDimensions (Shaft): 120 x 12mm\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCable Length: 3m\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTemperature Sensor: Yes\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eConnector: IP67 BNC, IP67 Cinch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\" style=\"text-align: center;\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cu data-mce-fragment=\"1\"\u003eCARE AND USE\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis delicate instrument requires proper care and maintenance to produce accurate, reliable results and to ensure a long, usable life.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eExtend the life of your pH electrode in the following ways:\u003c\/p\u003e\n\u003col data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAlways keep the electrode moist when not in use by placing it in an electrode storage solution (3M KCl).\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDO NOT store the electrode in distilled or deionized water, as this will cause ions to leak out of the glass bulb and reference electrolyte. This will produce a slow and sluggish response and can damage the electrode. \u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRemove the electrode gently from the storage bottle and rinse it with distilled water before use.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFor long-term storage, always keep the electrode in the bottle filled with enough storage solution to cover the bulb. Replenish the bottle as needed.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/dmx.ohaus.com\/WorkArea\/showcontent.aspx?id=34016\" target=\"_blank\"\u003eStarter Series Electrodes Data Sheet\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Ohaus","offers":[{"title":"Default Title","offer_id":39438702018609,"sku":"ST320 IP67","price":347.58,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/st320ip67.jpg?v=1630511068"},{"product_id":"ohaus-s272-2-in-1-plastic-puncture-ph-electrode","title":"Ohaus S272 2-in-1 Plastic Puncture pH Electrode","description":"\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cu\u003eOhaus S272 2-in-1 Plastic Puncture Non-refillable pH Electrode \u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe OHAUS Starter Series of electrodes are designed to produce exact results time and time again.  They fit perfectly in the electrode holders on OHAUS bench meters as well as electrode clips on all OHAUS portable meters.  This electrode is suitable for semi-solid samples such meat, fruits, or cheese.  The steel head ensures the structure is strong and durable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eSpecifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003epH Range: 2 to 12\u003c\/li\u003e\n\u003cli\u003eTemperature Range: 0 to 50 ºC\u003c\/li\u003e\n\u003cli\u003eShaft Material: Plastic\u003c\/li\u003e\n\u003cli\u003eInternal Reference Type: Ag\/AgCl\u003c\/li\u003e\n\u003cli\u003eRefillable\/Non-refillable: Non-refillable, gel\u003c\/li\u003e\n\u003cli\u003eReference Junction Type: Annular fiber\u003c\/li\u003e\n\u003cli\u003eRefilling Reference Electrolyte: 3M KCl gel\u003c\/li\u003e\n\u003cli\u003eDimensions (Shaft): 120 x 15mm\u003c\/li\u003e\n\u003cli\u003eCable Length: 1m\u003c\/li\u003e\n\u003cli\u003eTemperature Sensor: No\u003c\/li\u003e\n\u003cli\u003eConnector: BNC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cu\u003eCARE AND USE\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis delicate instrument requires proper care and maintenance to produce accurate, reliable results and to ensure a long, usable life.\u003c\/p\u003e\n\u003cp\u003eExtend the life of your pH electrode in the following ways:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAlways keep the electrode moist when not in use by placing it in an electrode storage solution (3M KCl).\u003c\/li\u003e\n\u003cli\u003eDO NOT store the electrode in distilled or deionized water, as this will cause ions to leak out of the glass bulb and reference electrolyte. This will produce a slow and sluggish response and can damage the electrode. \u003c\/li\u003e\n\u003cli\u003eRemove the electrode gently from the storage bottle and rinse it with distilled water before use.\u003c\/li\u003e\n\u003cli\u003eFor long-term storage, always keep the electrode in the bottle filled with enough storage solution to cover the bulb. Replenish the bottle as needed.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/dmx.ohaus.com\/WorkArea\/showcontent.aspx?id=34016\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e Starter Series Electrodes Data Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"Ohaus","offers":[{"title":"Default Title","offer_id":39441315823665,"sku":"ST272","price":327.74,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/ST272_oblique_DMX-ID_4294989306_WebShop.jpg?v=1630609149"},{"product_id":"ohaus-stcon3-ip67-conductivity-probe","title":"Ohaus STCON3 IP67 Conductivity Probe","description":"\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cu\u003eOhaus STCON3 IP67 Conductivity Probe \u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe OHAUS Starter Series are designed to produce exact results time and time again.  They fit perfectly in holders on OHAUS bench meters as well as clips on all OHAUS portable meters. \u003c\/p\u003e\n\u003cp\u003eThe STCON3 utilizes the 4-ring potentiometric method for measuring conductivity, which incorporates a series of four stainless steel rings formed into the probe shaft. This design eliminates polarization which occurs with the 2-plates amperometric method.  Furthermore, without polarization the probe can measure a wider range of conductivity values because it does not suffer from electrolysis.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eSpecifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConnection: IP67 LTW          \u003c\/li\u003e\n\u003cli\u003eCable Length: 3m\u003c\/li\u003e\n\u003cli\u003eShaft Length: 130 mm\u003c\/li\u003e\n\u003cli\u003eShaft Diameter: 14 mm\u003c\/li\u003e\n\u003cli\u003eTemperature Range: 0-50 ˚C\u003c\/li\u003e\n\u003cli\u003eMeasurement Range: 70 µS\/cm - 200mS\/cm (0.5% accuracy) ; 2 μS\/cm - 70μS\/cm (1% to 5% accuracy)\u003c\/li\u003e\n\u003cli\u003eCompatible With: ST400M IP67 waterproof portable meter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cu\u003eCARE AND USE\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe STCON3 conductivity probe has a built-in temperature sensor which is 30kΩ.  When using STCON3, please consider the following:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eMake sure the plastic shield is in place when measuring.\u003c\/li\u003e\n\u003cli\u003eBe sure the solution reached the line on the plastic shield and below the vent hole when measuring.\u003c\/li\u003e\n\u003cli\u003eTo prevent carry over from high to low conductivity solutions, rinse with distilled water between and after measurements.\u003c\/li\u003e\n\u003cli\u003eMake sure the cell chamber is bubble-free.\u003c\/li\u003e\n\u003cli\u003eAllow sufficient time for the sensor to stabilize when measuring samples at different temperatures. A manual end-point is advised.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/dmx.ohaus.com\/WorkArea\/showcontent.aspx?id=34016\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eStarter Series Electrodes Data Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"Ohaus","offers":[{"title":"Default Title","offer_id":39449537937457,"sku":"STCON3 IP67","price":717.61,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/Cond-Electrode-STCON3-IP67-3m_DMX-ID_4294991667_WebShop.jpg?v=1631211770"}],"url":"https:\/\/cambridgeenviro.com\/collections\/ohaus-electrodes.oembed?page=2","provider":"Cambridge Environmental Products, Inc.","version":"1.0","type":"link"}