{"title":"Laboratory Vacuum Pumps in Canada | Oil-Free \u0026 Chemistry Pumps | Cambridge","description":"\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eLaboratory Vacuum Pumps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003eCambridge Environmental supplies laboratory vacuum pumps in Canada for chemistry, filtration, drying, evaporation, and general lab use. Our range includes oil-free diaphragm vacuum pumps, chemistry-resistant vacuum pumps, rotary vane pumps, and complete vacuum pump systems from trusted brands such as VACUUBRAND. Whether you need a compact pump for routine filtration or a higher-performance chemistry pump for aggressive vapours, we can help match pumping speed, ultimate vacuum, chemical resistance, and noise level to your application.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eFAQ\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"763\" data-start=\"58\"\u003e\u003cstrong data-end=\"108\" data-start=\"58\"\u003eWhat type of laboratory vacuum pump do I need?\u003c\/strong\u003e\u003cbr data-end=\"111\" data-start=\"108\"\u003eThe right laboratory vacuum pump depends on your application, the vacuum level required, and whether you are handling clean air, aqueous samples, or aggressive chemical vapours. For most routine lab work, an oil-free diaphragm pump is the best starting point because dry pumps are commonly used in laboratories and are a good fit when you want low maintenance and a clean vacuum path. On your Cambridge collection, the range is already naturally split into chemistry diaphragm pumps, chemistry pumping systems, rotary vane pumps, and controller-based systems, which is the right way to guide buyers by application. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"1508\" data-start=\"765\"\u003e\u003cstrong data-end=\"850\" data-start=\"765\"\u003eWhat is the difference between an oil-free diaphragm pump and a rotary vane pump?\u003c\/strong\u003e\u003cbr data-end=\"853\" data-start=\"850\"\u003eAn oil-free diaphragm pump runs dry, avoids oil changes, and is better when you want a cleaner system with lower maintenance. A rotary vane pump is oil-lubricated and can provide higher vacuum levels and higher capacities, but it brings more maintenance and a greater risk of contamination from oil. Cole-Parmer’s guidance states that lubricated pumps generally offer higher capacities, deeper vacuum, and lower noise, while non-lubricated pumps are the better choice for clean systems and lower maintenance. VACUUBRAND’s diaphragm-pump guidance also emphasizes oil-free operation and minimal maintenance for lab use. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"2196\" data-start=\"1510\"\u003e\u003cstrong data-end=\"1562\" data-start=\"1510\"\u003eWhich vacuum pump is best for vacuum filtration?\u003c\/strong\u003e\u003cbr data-end=\"1565\" data-start=\"1562\"\u003eFor most laboratory vacuum filtration jobs, an oil-free diaphragm pump is usually the best choice because it gives you clean, dry vacuum with less maintenance than an oil-lubricated pump. If you are filtering non-aggressive samples, a standard dry diaphragm pump is often a solid fit. If you are filtering solvents or other chemically aggressive media, a chemistry diaphragm pump is the better option. That recommendation is an inference from the pump types in your collection and from supplier guidance that dry, oil-free diaphragm pumps are a common first choice for lab vacuum applications. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"2851\" data-start=\"2198\"\u003e\u003cstrong data-end=\"2256\" data-start=\"2198\"\u003eWhich vacuum pumps are suitable for corrosive vapours?\u003c\/strong\u003e\u003cbr data-end=\"2259\" data-start=\"2256\"\u003eFor corrosive vapours, chemistry diaphragm pumps are the right category to start with. VACUUBRAND states that its chemistry diaphragm pumps are designed for aggressive gases and vapours, and Cambridge’s VACUUBRAND product pages specifically note oil-free construction and corrosion-resistant materials such as PTFE heads and diaphragms. For higher-performance chemistry duty, models like the MD-series chemistry pumps are built for continuous oil-free pumping of corrosive gases and vapours and use chemically resistant fluoroplastics in the wetted path. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"3232\" data-start=\"2853\"\u003e\u003cstrong data-end=\"2905\" data-start=\"2853\"\u003eDo you supply laboratory vacuum pumps in Canada?\u003c\/strong\u003e\u003cbr data-end=\"2908\" data-start=\"2905\"\u003eYes. Cambridge Environmental supplies laboratory vacuum pumps in Canada. We have  37 different vacuum pumps available. We ship from our Komoka Ontario  Warehouse. And 100% Canadian Owned and operated. \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong data-end=\"5399\" data-start=\"5354\"\u003eNeed help choosing the right vacuum pump?\u003c\/strong\u003e\u003cbr data-end=\"5402\" data-start=\"5399\"\u003eWe can help match flow rate, ultimate vacuum, chemical resistance, and pump type to your application.\u003cstrong\u003e\u003c\/strong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"vacuubrand-me1-oil-free-diaphragm-vacuum-pump","title":"VACUUBRAND ME 1 Oil-Free Diaphragm Vacuum Pump 120V","description":"\u003cp style=\"text-align: center;\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eBrandTech™ VACUUBRAND™ ME 1 Diaphragm Vacuum Pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eVACUUBRAND™ ME 1 Compact Vacuum Pumps are intended specifically for non-corrosive, non-evaporative applications. They are excellent for laboratory and process-plant applications including gas transfer, backing turbo pumps, and vacuum filtration. All wetted parts of these pumps are made of aluminum, FKM, and polyethylene. Aluminum-FKM pumps should not be used with organic solvents, corrosives, or other vapors inconsistent with the materials of construction. \u003c\/p\u003e\n\u003cp\u003e \u003cb\u003eProduct Features:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e\u003cstrong\u003eNo Oil Changes\u003c\/strong\u003e - These vacuum pumps utilize diaphragm vacuum technology. The totally dry operation eliminates the misting, handling and disposal of contaminated waste associated with rotary vane pumps.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e\u003cstrong\u003eReduced Maintenance\u003c\/strong\u003e - Typical diaphragm lifetimes are well in excess of 15,000 hours of use before replacement, minimizing downtime and service costs. Unique design eliminates trial-and-error stroke length recalibration during replacement.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e\u003cstrong\u003eImproved Productivity\u003c\/strong\u003e - VACUUBRAND® pumps are engineered for performance, with flow rates as much as 40% higher at working vacuum level than competitive pumps with similar free air capacity ratings.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cspan style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e\u003cstrong\u003eReliability\u003c\/strong\u003e - All VACUUBRAND® pumps and systems must pass rigorous product testing before leaving the factory. It's your assurance of a reliable pump.\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cspan style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.8527%;\"\u003e \u003cstrong\u003eTechnical Data\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003e\u003cb\u003eME1\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.8527%;\"\u003eNumber of Heads\/Stages\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003e\n\u003cp\u003e1\/1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.8527%;\"\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003e\n\u003cp\u003e0.7\/0.8\u003cspan\u003em3\/h\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.8527%;\"\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003e\n\u003cp\u003e0.4\/0.5\u003cspan\u003ecfm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.8527%;\"\u003eUltimate Vacuum (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003e\n\u003cp\u003e100\/75\u003cspan\u003embar\/torr\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.8527%;\"\u003eAmbient Temperature Range (operation)\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003e\n\u003cp\u003e10 - 40\u003cb\u003e°\u003c\/b\u003e\u003cspan\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.8527%;\"\u003eAmbient Temperature Range (storage)\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003e\n\u003cp\u003e-10 - 60\u003cb\u003e°\u003c\/b\u003e\u003cspan\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.8527%;\"\u003eMax. Back Pressure (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003e\n\u003cp\u003e1.1\u003cspan\u003ebar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.8527%;\"\u003eInlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003e\n\u003cp\u003eHose Nozzle DN 6-10mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.8527%;\"\u003eOutlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003e\n\u003cp\u003eSilencer\/G1\/8\"\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.8527%;\"\u003eRated Motor Power\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003e\n\u003cp\u003e0.04\u003cspan\u003ekW\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.8527%;\"\u003eRated Motor Speed at 50\/60 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003e\n\u003cp\u003e1500\/1800\u003cspan\u003emin-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.8527%;\"\u003eProtection Class\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003e\n\u003cp\u003eIP 40\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.8527%;\"\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003e\n\u003cp\u003e247 x 121 x 145\u003cspan\u003emm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.8527%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003e\n\u003cp\u003e5.4\u003cspan\u003ekg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.8527%;\"\u003eNoise Level at 50 Hz, typ.\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003e\n\u003cp\u003e49\u003cspan\u003edBA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.8527%;\"\u003eNRTL Certification\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003e\n\u003cp\u003eCanada and the USA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.8527%;\"\u003eATEX Conformity (only 230V)\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003e\n\u003cp\u003eII 3\/-G Ex h IIC T3 Gc X Internal Atm. only\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.8527%;\"\u003eItems Supplied\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003e\n\u003cp\u003ePump oil filled and completely mounted, ready for use, w\/ manual\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cspan style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e\u003cbr\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003ca title=\"ME1 Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/ME1_ME1C_FLY_BT.pdf?v=1674667061\" target=\"_blank\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"faq\"\u003e\n\u003ch3\u003eWhat is the expected lifespan of the diaphragm?\u003c\/h3\u003e\n\u003cp\u003eThe diaphragm is designed to last over 15,000 hours under normal operating conditions, which translates to years of reliable service in most lab settings.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq\"\u003e\n\u003ch3\u003eIs this pump suitable for corrosive applications?\u003c\/h3\u003e\n\u003cp\u003eYes, the PTFE diaphragm and valves provide excellent chemical resistance, making it ideal for a wide range of lab applications, including those involving corrosive gases and vapors.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eReady to Order?\u003c\/h2\u003e\n\u003cp\u003eAdd the VACUUBRAND ME 1 to your cart today and experience the difference of a high-performance, oil-free vacuum pump. Fast shipping across Canada!\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cscribe-shadow id=\"crxjs-ext\" data-crx=\"okfkdaglfjjjfefdcppliegebpoegaii\" style=\"position: fixed; width: 0px; height: 0px; top: 0px; left: 0px; z-index: 2147483647; overflow: visible; visibility: visible;\"\u003e\u003c\/scribe-shadow\u003e\u003c\/p\u003e","brand":"BrandTech Scientific","offers":[{"title":"Default Title","offer_id":42636478382339,"sku":"20721003","price":1869.07,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale)","offer_id":42636478415107,"sku":"20721003","price":1495.25,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/20721003.jpg?v=1648661580"},{"product_id":"vacuubrand-me-2-nt-oil-free-diaphragm-vacuum-pump","title":"VACUUBRAND ME 2 NT Oil-Free Diaphragm Vacuum Pump","description":"\u003cp style=\"text-align: center;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eBrandTech™ VACUUBRAND™ ME 2 NT Diaphragm Vacuum Pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cspan\u003eVACUUBRAND™ ME 2 NT Diaphragm Vacuum Pumps are designed specifically for non-corrosive, non-evaporative applications. They are excellent for laboratory and process-plant applications including gas transfer, backing turbo pumps, and vacuum filtration. All wetted parts of these pumps are made of aluminum, FKM, and polyethylene. Aluminum-FKM pumps should not be used with organic solvents, corrosives, or other vapors inconsistent with the materials of construction.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eA one-stage diaphragm pump is ideal for continuously pumping volatile gases and vapours without requiring a great deal of vacuum. Contrary to waterjet pumps, they do not consume water and thus do not produce any contaminated wastewater on a daily basis. Typical applications are vacuum ovens, filtrations and multi-port manifolds for medium-throughput, as well as pumping of gases and oil-free evacuation in general. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe pump combines a fast pumping speed with low ultimate vacuum down to 70 mbar. Fully assembled, ready to use, with instructions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eNo Oil Changes\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eThese vacuum pumps utilize diaphragm vacuum technology. The totally dry operation eliminates the misting, handling and disposal of contaminated waste associated with rotary vane pumps. No oil to change or monitor!\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eReduced Maintenance\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eTypical diaphragm lifetimes are well in excess of 15,000 hours of use before replacement - that's years in most applications, minimizing downtime and service costs. When it is finally time for service, their unique design eliminates tedious, trial-and-error stroke length recalibration.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eImproved Productivity\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eVACUUBRAND\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003epumps are engineered for performance, with flow rates as much as 40% higher at working vacuum level than competitive pumps with similar free air capacity ratings. Higher flow rates mean reduced process times and higher throughput.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eReliability\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eAll VACUUBRAND\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003epumps and systems must pass rigorous product testing before leaving the factory. It's your assurance of a reliable pump.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong\u003eWhisper Quiet Operation\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong\u003eAluminum and FKM \u003c\/strong\u003ewetted materials\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong\u003eLow Maintenance\u003c\/strong\u003e\u003cstrong\u003e \u003c\/strong\u003e- 15,000-hour service intervals typical\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong\u003eCommon Applications \u003c\/strong\u003einclude gas transfer, filtration, and roughing for high vacuum systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.4415%;\"\u003e \u003cstrong\u003eTechnical Data\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 51%;\"\u003e\u003cb\u003eME2 NT\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.4415%;\"\u003eNumber of Heads\/Stages\u003c\/td\u003e\n\u003ctd style=\"width: 51%;\"\u003e\n\u003cp\u003e1\/1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.4415%;\"\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51%;\"\u003e\n\u003cp\u003e2.0\/2.2\u003cspan data-mce-fragment=\"1\"\u003em3\/h\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.4415%;\"\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51%;\"\u003e\n\u003cp\u003e1.2\/1.3\u003cspan data-mce-fragment=\"1\"\u003ecfm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.4415%;\"\u003eUltimate Vacuum (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 51%;\"\u003e\n\u003cp\u003e70\/52\u003cspan data-mce-fragment=\"1\"\u003embar\/torr\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.4415%;\"\u003eAmbient Temperature Range (operation)\u003c\/td\u003e\n\u003ctd style=\"width: 51%;\"\u003e\n\u003cp\u003e10 - 40\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.4415%;\"\u003eAmbient Temperature Range (storage)\u003c\/td\u003e\n\u003ctd style=\"width: 51%;\"\u003e\n\u003cp\u003e-10 - 60\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.4415%;\"\u003eMax. Back Pressure (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 51%;\"\u003e\n\u003cp\u003e2bar\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.4415%;\"\u003eInlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 51%;\"\u003e\n\u003cp\u003eHose Nozzle DN 8-10mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.4415%;\"\u003eOutlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 51%;\"\u003e\n\u003cp\u003eSilencer\/G1\/4\"\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.4415%;\"\u003eRated Motor Power\u003c\/td\u003e\n\u003ctd style=\"width: 51%;\"\u003e\n\u003cp\u003e0.18kW\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.4415%;\"\u003eRated Motor Speed at 50\/60 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 51%;\"\u003e\n\u003cp\u003e1500\/1800\u003cspan data-mce-fragment=\"1\"\u003emin-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.4415%;\"\u003eProtection Class\u003c\/td\u003e\n\u003ctd style=\"width: 51%;\"\u003e\n\u003cp\u003eIP 40\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.4415%;\"\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd style=\"width: 51%;\"\u003e\n\u003cp\u003e243 x 211 x 198mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.4415%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 51%;\"\u003e\n\u003cp\u003e10.2kg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.4415%;\"\u003eNoise Level at 50 Hz, typ.\u003c\/td\u003e\n\u003ctd style=\"width: 51%;\"\u003e\n\u003cp\u003e45dBA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.4415%;\"\u003eNRTL Certification\u003c\/td\u003e\n\u003ctd style=\"width: 51%;\"\u003e\n\u003cp\u003eCanada and the USA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.4415%;\"\u003eATEX Conformity (only 230V)\u003c\/td\u003e\n\u003ctd style=\"width: 51%;\"\u003e\n\u003cp\u003eII 3\/-G Ex h IIC T3 Gc X Internal Atm. only\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.4415%;\"\u003eItems Supplied\u003c\/td\u003e\n\u003ctd style=\"width: 51%;\"\u003e\n\u003cp\u003ePump oil filled and completely mounted, ready for use, w\/ manual\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003cbr\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eLiterature:\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/manual-Pumpen.pdf?v=1686244917\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eVaccuBrand ME 2 NT Diaphragm Pump Manual\u003c\/a\u003e\u003c\/p\u003e","brand":"BrandTech Scientific","offers":[{"title":"Default Title","offer_id":42636510494979,"sku":"20730003","price":3275.01,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale)","offer_id":42636510527747,"sku":"20730003","price":2620.01,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/20730003.jpg?v=1648662190"},{"product_id":"vacuubrand-me-4-nt-oil-free-diaphragm-vacuum-pump","title":"VACUUBRAND ME 4 NT Oil-Free Diaphragm Vacuum Pump","description":"\u003cp style=\"text-align: center;\" data-mce-fragment=\"1\" data-mce-style=\"text-align: center;\"\u003e\u003cspan style=\"text-decoration: underline;\" data-mce-style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eBrandTech™ VACUUBRAND™ ME 4 NT Diaphragm Vacuum Pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eVACUUBRAND™ ME 4 NT Diaphragm Vacuum Pumps are intended specifically for non-corrosive, non-evaporative applications. They are excellent for laboratory and process-plant applications including gas transfer, backing turbo pumps, and vacuum filtration. All wetted parts of these pumps are made of aluminum, FKM, and polyethylene. Aluminum-FKM pumps should not be used with organic solvents, corrosives, or other vapors inconsistent with the materials of construction.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eGases can be evacuated and pumped continuously with diaphragm pumps using no oil. Aluminum and selected plastics are used for all parts in contact with pumped media, which allows for a wide range of non-corrosive applications. It combines a high pumping speed with an ultimate vacuum of 70 mbar with a one-stage design. The highly flexible FKM diaphragm, which is made up of fabric-reinforced layers, provides extended operating life. Performance data is further improved in the NT series.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eNo Oil Changes\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eThese vacuum pumps utilize diaphragm vacuum technology. The totally dry operation eliminates the misting, handling and disposal of contaminated waste associated with rotary vane pumps. No oil to change or monitor!\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eReduced Maintenance\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eTypical diaphragm lifetimes are well in excess of 15,000 hours of use before replacement - that's years in most applications, minimizing downtime and service costs. When it is finally time for service, their unique design eliminates tedious, trial-and-error stroke length recalibration.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eImproved Productivity\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eVACUUBRAND\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003epumps are engineered for performance, with flow rates as much as 40% higher at working vacuum level than competitive pumps with similar free air capacity ratings. Higher flow rates mean reduced process times and higher throughput.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eReliability\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eAll VACUUBRAND\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003epumps and systems must pass rigorous product testing before leaving the factory. It's your assurance of a reliable pump\u003cbr\u003e\u003cbr\u003e\n\u003ctable width=\"100%\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 59.4375%;\" data-mce-fragment=\"1\" data-mce-style=\"width: 59.4375%;\"\u003e \u003cstrong data-mce-fragment=\"1\"\u003eTechnical Data\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\" data-mce-fragment=\"1\" data-mce-style=\"width: 50%;\"\u003e\u003cb\u003eME4 NT\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 59.4375%;\" data-mce-fragment=\"1\" data-mce-style=\"width: 59.4375%;\"\u003eNumber of Heads\/Stages\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\" data-mce-fragment=\"1\" data-mce-style=\"width: 50%;\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e2\/1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 59.4375%;\" data-mce-fragment=\"1\" data-mce-style=\"width: 59.4375%;\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\" data-mce-fragment=\"1\" data-mce-style=\"width: 50%;\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e4.0\/4.4\u003cspan data-mce-fragment=\"1\"\u003em3\/h\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 59.4375%;\" data-mce-fragment=\"1\" data-mce-style=\"width: 59.4375%;\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\" data-mce-fragment=\"1\" data-mce-style=\"width: 50%;\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e2.4\/2.6\u003cspan data-mce-fragment=\"1\"\u003ecfm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 59.4375%;\" data-mce-fragment=\"1\" data-mce-style=\"width: 59.4375%;\"\u003eUltimate Vacuum (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\" data-mce-fragment=\"1\" data-mce-style=\"width: 50%;\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e70\/52\u003cspan data-mce-fragment=\"1\"\u003embar\/torr\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 59.4375%;\" data-mce-fragment=\"1\" data-mce-style=\"width: 59.4375%;\"\u003eAmbient Temperature Range (operation)\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\" data-mce-fragment=\"1\" data-mce-style=\"width: 50%;\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e10 - 40\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 59.4375%;\" data-mce-fragment=\"1\" data-mce-style=\"width: 59.4375%;\"\u003eAmbient Temperature Range (storage)\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\" data-mce-fragment=\"1\" data-mce-style=\"width: 50%;\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e-10 - 60\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 59.4375%;\" data-mce-fragment=\"1\" data-mce-style=\"width: 59.4375%;\"\u003eMax. Back Pressure (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\" data-mce-fragment=\"1\" data-mce-style=\"width: 50%;\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e2\u003cspan data-mce-fragment=\"1\"\u003ebar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 59.4375%;\" data-mce-fragment=\"1\" data-mce-style=\"width: 59.4375%;\"\u003eInlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\" data-mce-fragment=\"1\" data-mce-style=\"width: 50%;\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eHose Nozzle DN 8-10mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 59.4375%;\" data-mce-fragment=\"1\" data-mce-style=\"width: 59.4375%;\"\u003eOutlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\" data-mce-fragment=\"1\" data-mce-style=\"width: 50%;\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e2 x Silencer\/G1\/4\"\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 59.4375%;\" data-mce-fragment=\"1\" data-mce-style=\"width: 59.4375%;\"\u003eRated Motor Power\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\" data-mce-fragment=\"1\" data-mce-style=\"width: 50%;\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e0.18kW\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 59.4375%;\" data-mce-fragment=\"1\" data-mce-style=\"width: 59.4375%;\"\u003eRated Motor Speed at 50\/60 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\" data-mce-fragment=\"1\" data-mce-style=\"width: 50%;\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e1500\/1800\u003cspan data-mce-fragment=\"1\"\u003emin-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 59.4375%;\" data-mce-fragment=\"1\" data-mce-style=\"width: 59.4375%;\"\u003eProtection Class\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\" data-mce-fragment=\"1\" data-mce-style=\"width: 50%;\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eIP 40\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 59.4375%;\" data-mce-fragment=\"1\" data-mce-style=\"width: 59.4375%;\"\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\" data-mce-fragment=\"1\" data-mce-style=\"width: 50%;\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e243 x 239 x 198mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 59.4375%;\" data-mce-fragment=\"1\" data-mce-style=\"width: 59.4375%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\" data-mce-fragment=\"1\" data-mce-style=\"width: 50%;\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e11.0kg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 59.4375%;\" data-mce-fragment=\"1\" data-mce-style=\"width: 59.4375%;\"\u003eNoise Level at 50 Hz, typ.\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\" data-mce-fragment=\"1\" data-mce-style=\"width: 50%;\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e45dBA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 59.4375%;\" data-mce-fragment=\"1\" data-mce-style=\"width: 59.4375%;\"\u003eNRTL Certification\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\" data-mce-fragment=\"1\" data-mce-style=\"width: 50%;\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eCanada and the USA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 59.4375%;\" data-mce-fragment=\"1\" data-mce-style=\"width: 59.4375%;\"\u003eATEX Conformity (only 230V)\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\" data-mce-fragment=\"1\" data-mce-style=\"width: 50%;\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eII 3\/-G Ex h IIC T3 Gc X Internal Atm. only\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 59.4375%;\" data-mce-fragment=\"1\" data-mce-style=\"width: 59.4375%;\"\u003eItems Supplied\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\" data-mce-fragment=\"1\" data-mce-style=\"width: 50%;\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003ePump oil filled and completely mounted, ready for use, w\/ manual\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"BrandTech Scientific","offers":[{"title":"Default Title","offer_id":42636594872579,"sku":"20731003","price":5098.4,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale)","offer_id":42636594905347,"sku":"20731003","price":4078.72,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/20731003.jpg?v=1648665704"},{"product_id":"vacuubrand-me-8-nt-oil-free-diaphragm-vacuum-pump","title":"VACUUBRAND ME 8 NT Oil-Free Diaphragm Vacuum Pump","description":"\u003cdiv style=\"text-align: center;\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eBrandTech™ VACUUBRAND™ ME 8 NT Diaphragm Vacuum Pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003eVACUUBRAND™ ME 8 NT Diaphragm Vacuum Pumps are an excellent choice for continuous, oil-free evacuation and pumping of gases. Aluminum and selected plastics are used in all parts in contact with pumped media, and this enables the pump to be used for a wide range of non-corrosive gases. \u003c\/span\u003eThese pumps with four heads provide a very high pumping speed. \u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eThe new NT-series of pumps provide whisper-quiet and ultra-low-vibration operation, high leak-tightness and improved vacuum. The highly flexible, fabric-reinforced double diaphragm made of FKM offers extended operation life.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eNo Oil Changes\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eThese vacuum pumps utilize diaphragm vacuum technology. The totally dry operation eliminates the misting, handling and disposal of contaminated waste associated with rotary vane pumps. No oil to change or monitor!\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eReduced Maintenance\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eTypical diaphragm lifetimes are well in excess of 15,000 hours of use before replacement - that's years in most applications, minimizing downtime and service costs. When it is finally time for service, their unique design eliminates tedious, trial-and-error stroke length recalibration.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eImproved Productivity\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eVACUUBRAND\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003epumps are engineered for performance, with flow rates as much as 40% higher at working vacuum level than competitive pumps with similar free air capacity ratings. Higher flow rates mean reduced process times and higher throughput.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eReliability\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eAll VACUUBRAND\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003epumps and systems must pass rigorous product testing before leaving the factory. It's your assurance of a reliable pump.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.3291%;\"\u003e \u003cstrong\u003eTechnical Data\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 51.1927%;\"\u003e\u003cb\u003eME 8 NT\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.3291%;\"\u003eNumber of Heads\/Stages\u003c\/td\u003e\n\u003ctd style=\"width: 51.1927%;\"\u003e\n\u003cp\u003e4\/1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.3291%;\"\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.1927%;\"\u003e\n\u003cp\u003e7.3\/8.1\u003cspan data-mce-fragment=\"1\"\u003em3\/h\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.3291%;\"\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.1927%;\"\u003e\n\u003cp\u003e4.3\/4.8\u003cspan data-mce-fragment=\"1\"\u003ecfm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.3291%;\"\u003eUltimate Vacuum (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 51.1927%;\"\u003e\n\u003cp\u003e70\/52\u003cspan data-mce-fragment=\"1\"\u003embar\/torr\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.3291%;\"\u003eAmbient Temperature Range (operation)\u003c\/td\u003e\n\u003ctd style=\"width: 51.1927%;\"\u003e\n\u003cp\u003e10 - 40\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.3291%;\"\u003eAmbient Temperature Range (storage)\u003c\/td\u003e\n\u003ctd style=\"width: 51.1927%;\"\u003e\n\u003cp\u003e-10 - 60\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.3291%;\"\u003eMax. Back Pressure (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 51.1927%;\"\u003e\n\u003cp\u003e2\u003cspan data-mce-fragment=\"1\"\u003ebar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.3291%;\"\u003eInlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 51.1927%;\"\u003e\n\u003cp\u003eHose Nozzle DN 8-10mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.3291%;\"\u003eOutlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 51.1927%;\"\u003e\n\u003cp\u003e2 x Silencer\/G1\/4\"\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.3291%;\"\u003eRated Motor Power\u003c\/td\u003e\n\u003ctd style=\"width: 51.1927%;\"\u003e\n\u003cp\u003e0.25\u003cspan data-mce-fragment=\"1\"\u003ekW\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.3291%;\"\u003eRated Motor Speed at 50\/60 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 51.1927%;\"\u003e\n\u003cp\u003e1500\/1800\u003cspan data-mce-fragment=\"1\"\u003emin-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.3291%;\"\u003eProtection Class\u003c\/td\u003e\n\u003ctd style=\"width: 51.1927%;\"\u003e\n\u003cp\u003eIP 40\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.3291%;\"\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd style=\"width: 51.1927%;\"\u003e\n\u003cp\u003e325 x 239 x 198\u003cspan data-mce-fragment=\"1\"\u003emm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.3291%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 51.1927%;\"\u003e\n\u003cp\u003e16.4\u003cspan data-mce-fragment=\"1\"\u003ekg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.3291%;\"\u003eNoise Level at 50 Hz, typ.\u003c\/td\u003e\n\u003ctd style=\"width: 51.1927%;\"\u003e\n\u003cp\u003e45\u003cspan data-mce-fragment=\"1\"\u003edBA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.3291%;\"\u003eNRTL Certification\u003c\/td\u003e\n\u003ctd style=\"width: 51.1927%;\"\u003e\n\u003cp\u003eCanada and the USA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.3291%;\"\u003eATEX Conformity (only 230V)\u003c\/td\u003e\n\u003ctd style=\"width: 51.1927%;\"\u003e\n\u003cp\u003eII 3\/-G Ex h IIC T3 X Internal Atm. only\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.3291%;\"\u003eItems Supplied\u003c\/td\u003e\n\u003ctd style=\"width: 51.1927%;\"\u003e\n\u003cp\u003ePump oil filled and completely mounted, ready for use, w\/ manual\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"BrandTech Scientific","offers":[{"title":"Default Title","offer_id":42636605882627,"sku":"20734003","price":9024.74,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale)","offer_id":42636605915395,"sku":"20734003","price":7219.79,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/20734003.jpg?v=1648666594"},{"product_id":"vacuubrand-mz-2-nt-oil-free-diaphragm-vacuum-pump","title":"VACUUBRAND MZ 2 NT Oil-Free Diaphragm Vacuum Pump","description":"\u003cp style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eBrandTech™ VACUUBRAND™ MZ 2 NT Diaphragm Vacuum Pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eVACUUBRAND™ MZ 2 NT Diaphragm Vacuum Pumps are designed specifically for non-corrosive, non-evaporative applications. \u003cspan data-mce-fragment=\"1\"\u003eThey are excellent for laboratory and process-plant applications including gas transfer, backing turbo pumps, and vacuum filtration. All wetted parts of these pumps are made of aluminum, FKM, and polyethylene. Aluminum-FKM pumps should not be used with organic solvents, corrosives, or other vapors inconsistent with the materials of construction.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eNo Oil Changes\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eThese vacuum pumps utilize diaphragm vacuum technology. The totally dry operation eliminates the misting, handling and disposal of contaminated waste associated with rotary vane pumps. No oil to change or monitor!\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eReduced Maintenance\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eTypical diaphragm lifetimes are well in excess of 15,000 hours of use before replacement - that's years in most applications, minimizing downtime and service costs. When it is finally time for service, their unique design eliminates tedious, trial-and-error stroke length recalibration.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eImproved Productivity\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eVACUUBRAND\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003epumps are engineered for performance, with flow rates as much as 40% higher at working vacuum level than competitive pumps with similar free air capacity ratings. Higher flow rates mean reduced process times and higher throughput.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eReliability\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eAll VACUUBRAND\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003epumps and systems must pass rigorous product testing before leaving the factory. It's your assurance of a reliable pump.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.3698%;\"\u003e \u003cstrong\u003eTechnical Data\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 51.5109%;\"\u003e\u003cb\u003eMZ 2 NT\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.3698%;\"\u003eNumber of Heads\/Stages\u003c\/td\u003e\n\u003ctd style=\"width: 51.5109%;\"\u003e\n\u003cp\u003e2\/2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.3698%;\"\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.5109%;\"\u003e\n\u003cp\u003e2.3\/2.5\u003cspan data-mce-fragment=\"1\"\u003em3\/h\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.3698%;\"\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.5109%;\"\u003e\n\u003cp\u003e1.4\/1.5\u003cspan data-mce-fragment=\"1\"\u003ecfm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.3698%;\"\u003eUltimate Vacuum (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 51.5109%;\"\u003e\n\u003cp\u003e4\/3\u003cspan data-mce-fragment=\"1\"\u003embar\/torr\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.3698%;\"\u003eAmbient Temperature Range (operation)\u003c\/td\u003e\n\u003ctd style=\"width: 51.5109%;\"\u003e\n\u003cp\u003e10 - 40\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.3698%;\"\u003eAmbient Temperature Range (storage)\u003c\/td\u003e\n\u003ctd style=\"width: 51.5109%;\"\u003e\n\u003cp\u003e-10 - 60\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.3698%;\"\u003eMax. Back Pressure (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 51.5109%;\"\u003e\n\u003cp\u003e1.1\u003cspan data-mce-fragment=\"1\"\u003ebar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.3698%;\"\u003eInlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 51.5109%;\"\u003e\n\u003cp\u003e\u003cspan\u003esmall flange KF DN 16\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.3698%;\"\u003eOutlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 51.5109%;\"\u003e\n\u003cp\u003eSilencer\/G1\/4\"\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.3698%;\"\u003eRated Motor Power\u003c\/td\u003e\n\u003ctd style=\"width: 51.5109%;\"\u003e\n\u003cp\u003e0.18\u003cspan data-mce-fragment=\"1\"\u003ekW\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.3698%;\"\u003eRated Motor Speed at 50\/60 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 51.5109%;\"\u003e\n\u003cp\u003e1500\/1800\u003cspan data-mce-fragment=\"1\"\u003emin-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.3698%;\"\u003eProtection Class\u003c\/td\u003e\n\u003ctd style=\"width: 51.5109%;\"\u003e\n\u003cp\u003eIP 40\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.3698%;\"\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd style=\"width: 51.5109%;\"\u003e\n\u003cp\u003e243 x 242 x 198\u003cspan data-mce-fragment=\"1\"\u003emm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.3698%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 51.5109%;\"\u003e\n\u003cp\u003e11.4\u003cspan data-mce-fragment=\"1\"\u003ekg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.3698%;\"\u003eNoise Level at 50 Hz, typ.\u003c\/td\u003e\n\u003ctd style=\"width: 51.5109%;\"\u003e\n\u003cp\u003e47\u003cspan data-mce-fragment=\"1\"\u003edBA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.3698%;\"\u003eNRTL Certification\u003c\/td\u003e\n\u003ctd style=\"width: 51.5109%;\"\u003e\n\u003cp\u003eCanada and the USA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.3698%;\"\u003eATEX Conformity (only 230V)\u003c\/td\u003e\n\u003ctd style=\"width: 51.5109%;\"\u003e\n\u003cp\u003eII 3\/-G Ex h IIC T3 X Internal Atm. only\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.3698%;\"\u003eItems Supplied\u003c\/td\u003e\n\u003ctd style=\"width: 51.5109%;\"\u003e\n\u003cp\u003ePump oil filled and completely mounted, ready for use, w\/ manual\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"BrandTech Scientific","offers":[{"title":"Default Title","offer_id":42636740231427,"sku":"20732003","price":5096.27,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale)","offer_id":42636740264195,"sku":"20732003","price":4077.02,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/20732003.jpg?v=1648671730"},{"product_id":"vacuubrand-md-4-nt-oil-free-diaphragm-vacuum-pump","title":"VACUUBRAND MD 4 NT Oil-Free Diaphragm Vacuum Pump","description":"\u003cp style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eBrandTech™ VACUUBRAND™ MD 4 NT Diaphragm Vacuum Pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eVACUUBRAND™ MD 4 NT Diaphragm Vacuum Pumps are designed specifically for non-corrosive, non-evaporative applications. This line of aluminum-FKM diaphragm pumps are an excellent choice for a wide range of laboratory and process plant vacuum applications.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe new NT-series of pumps provide whisper-quiet and ultra-low-vibration operation, high leak-tightness and improved vacuum. The highly flexible, fabric-reinforced double diaphragm made of FKM offers extended operation life.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eNo Oil Changes\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eThese vacuum pumps utilize diaphragm vacuum technology. The totally dry operation eliminates the misting, handling and disposal of contaminated waste associated with rotary vane pumps. No oil to change or monitor!\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eReduced Maintenance\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eTypical diaphragm lifetimes are well in excess of 15,000 hours of use before replacement - that's years in most applications, minimizing downtime and service costs. When it is finally time for service, their unique design eliminates tedious, trial-and-error stroke length recalibration.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eImproved Productivity\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eVACUUBRAND\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003epumps are engineered for performance, with flow rates as much as 40% higher at working vacuum level than competitive pumps with similar free air capacity ratings. Higher flow rates mean reduced process times and higher throughput.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eReliability\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eAll VACUUBRAND\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003epumps and systems must pass rigorous product testing before leaving the factory. It's your assurance of a reliable pump.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.1244%;\"\u003e \u003cstrong\u003eTechnical Data\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.7563%;\"\u003e\u003cb\u003eMD 4 NT\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.1244%;\"\u003eNumber of Heads\/Stages\u003c\/td\u003e\n\u003ctd style=\"width: 54.7563%;\"\u003e\n\u003cp\u003e4\/3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.1244%;\"\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.7563%;\"\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e3.8\/4.3m3\/h\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.1244%;\"\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.7563%;\"\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e2.2\/2.5cfm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.1244%;\"\u003eUltimate Vacuum (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 54.7563%;\"\u003e\n\u003cp\u003e1\/0.75\u003cspan data-mce-fragment=\"1\"\u003embar\/torr\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.1244%;\"\u003eAmbient Temperature Range (operation)\u003c\/td\u003e\n\u003ctd style=\"width: 54.7563%;\"\u003e\n\u003cp\u003e10 - 40\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.1244%;\"\u003eAmbient Temperature Range (storage)\u003c\/td\u003e\n\u003ctd style=\"width: 54.7563%;\"\u003e\n\u003cp\u003e-10 - 60\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.1244%;\"\u003eMax. Back Pressure (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 54.7563%;\"\u003e\n\u003cp\u003e1.1\u003cspan data-mce-fragment=\"1\"\u003ebar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.1244%;\"\u003eInlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 54.7563%;\"\u003e\n\u003cp\u003eSmall Flange KF DN 16\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.1244%;\"\u003eOutlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 54.7563%;\"\u003e\n\u003cp\u003eSilencer\/G1\/4\"\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.1244%;\"\u003eRated Motor Power\u003c\/td\u003e\n\u003ctd style=\"width: 54.7563%;\"\u003e\n\u003cp\u003e0.25\u003cspan data-mce-fragment=\"1\"\u003ekW\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.1244%;\"\u003eRated Motor Speed at 50\/60 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 54.7563%;\"\u003e\n\u003cp\u003e1500\/1800\u003cspan data-mce-fragment=\"1\"\u003emin-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.1244%;\"\u003eProtection Class\u003c\/td\u003e\n\u003ctd style=\"width: 54.7563%;\"\u003e\n\u003cp\u003eIP 40\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.1244%;\"\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd style=\"width: 54.7563%;\"\u003e\n\u003cp\u003e325 x 239 x 198\u003cspan data-mce-fragment=\"1\"\u003emm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.1244%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 54.7563%;\"\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e16.4kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.1244%;\"\u003eNoise Level at 50 Hz, typ.\u003c\/td\u003e\n\u003ctd style=\"width: 54.7563%;\"\u003e\n\u003cp\u003e45\u003cspan data-mce-fragment=\"1\"\u003edBA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.1244%;\"\u003eNRTL Certification\u003c\/td\u003e\n\u003ctd style=\"width: 54.7563%;\"\u003e\n\u003cp\u003eCanada and the USA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"BrandTech Scientific","offers":[{"title":"Default Title","offer_id":42643938115843,"sku":"20736005","price":7956.67,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale)","offer_id":42644132135171,"sku":"20736005","price":6365.34,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/20736005.jpg?v=1648829421"},{"product_id":"vacuubrand-mv-2-nt-oil-free-diaphragm-vacuum-pump","title":"VACUUBRAND MV 2 NT Oil-Free Diaphragm Vacuum Pump","description":"\u003cp style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eBrandTech™ VACUUBRAND™ MV 2 NT Diaphragm Vacuum Pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eVACUUBRAND™ MV 2 NT Diaphragm Vacuum Pumps are designed specifically for non-corrosive, non-evaporative applications. This line of aluminum-FKM diaphragm pumps are an excellent choice for a wide range of laboratory and process plant vacuum applications.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe new NT-series of pumps provide whisper-quiet and ultra-low-vibration operation, high leak-tightness and improved vacuum. The highly flexible, fabric-reinforced double diaphragm made of FKM offers extended operation life.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eNo Oil Changes\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eThese vacuum pumps utilize diaphragm vacuum technology. The totally dry operation eliminates the misting, handling and disposal of contaminated waste associated with rotary vane pumps. No oil to change or monitor!\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eReduced Maintenance\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eTypical diaphragm lifetimes are well in excess of 15,000 hours of use before replacement - that's years in most applications, minimizing downtime and service costs. When it is finally time for service, their unique design eliminates tedious, trial-and-error stroke length recalibration.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eImproved Productivity\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eVACUUBRAND\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003epumps are engineered for performance, with flow rates as much as 40% higher at working vacuum level than competitive pumps with similar free air capacity ratings. Higher flow rates mean reduced process times and higher throughput.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eReliability\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eAll VACUUBRAND\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003epumps and systems must pass rigorous product testing before leaving the factory. It's your assurance of a reliable pump.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.4117%;\"\u003e \u003cstrong\u003eTechnical Data\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 51.1927%;\"\u003e\u003cb\u003eMV2\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.4117%;\"\u003eNumber of Heads\/Stages\u003c\/td\u003e\n\u003ctd style=\"width: 51.1927%;\"\u003e\n\u003cp\u003e4\/4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.4117%;\"\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.1927%;\"\u003e\n\u003cp\u003e2.2\/2.4\u003cspan data-mce-fragment=\"1\"\u003em3\/h\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.4117%;\"\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.1927%;\"\u003e\n\u003cp\u003e1.3\/1.4\u003cspan data-mce-fragment=\"1\"\u003ecfm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.4117%;\"\u003eUltimate Vacuum (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 51.1927%;\"\u003e\n\u003cp\u003e0.5\/0.4\u003cspan data-mce-fragment=\"1\"\u003embar\/torr\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.4117%;\"\u003eAmbient Temperature Range (operation)\u003c\/td\u003e\n\u003ctd style=\"width: 51.1927%;\"\u003e\n\u003cp\u003e10 - 40\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.4117%;\"\u003eAmbient Temperature Range (storage)\u003c\/td\u003e\n\u003ctd style=\"width: 51.1927%;\"\u003e\n\u003cp\u003e-10 - 60\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.4117%;\"\u003eMax. Back Pressure (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 51.1927%;\"\u003e\n\u003cp\u003e1.1\u003cspan data-mce-fragment=\"1\"\u003ebar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.4117%;\"\u003eInlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 51.1927%;\"\u003e\n\u003cp\u003e\u003cspan\u003esmall flange KF DN 16\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.4117%;\"\u003eOutlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 51.1927%;\"\u003e\n\u003cp\u003eSilencer\/G1\/4\"\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.4117%;\"\u003eRated Motor Power\u003c\/td\u003e\n\u003ctd style=\"width: 51.1927%;\"\u003e\n\u003cp\u003e0.25\u003cspan data-mce-fragment=\"1\"\u003ekW\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.4117%;\"\u003eRated Motor Speed at 50\/60 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 51.1927%;\"\u003e\n\u003cp\u003e1500\/1800\u003cspan data-mce-fragment=\"1\"\u003emin-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.4117%;\"\u003eProtection Class\u003c\/td\u003e\n\u003ctd style=\"width: 51.1927%;\"\u003e\n\u003cp\u003eIP 40\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.4117%;\"\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd style=\"width: 51.1927%;\"\u003e\n\u003cp\u003e325 x 239 x 198\u003cspan data-mce-fragment=\"1\"\u003emm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.4117%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 51.1927%;\"\u003e\n\u003cp\u003e16.4\u003cspan data-mce-fragment=\"1\"\u003ekg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.4117%;\"\u003eNoise Level at 50 Hz, typ.\u003c\/td\u003e\n\u003ctd style=\"width: 51.1927%;\"\u003e\n\u003cp\u003e50\u003cspan data-mce-fragment=\"1\"\u003edBA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.4117%;\"\u003eNRTL Certification\u003c\/td\u003e\n\u003ctd style=\"width: 51.1927%;\"\u003e\n\u003cp\u003eCanada and the USA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.4117%;\"\u003eATEX Conformity (only 230V)\u003c\/td\u003e\n\u003ctd style=\"width: 51.1927%;\"\u003e\n\u003cp\u003eII 3\/-G Ex h IIC T3 X Internal Atm. only\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.4117%;\"\u003eItems Supplied\u003c\/td\u003e\n\u003ctd style=\"width: 51.1927%;\"\u003e\n\u003cp\u003ePump oil filled and completely mounted, ready for use, w\/ manual\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"BrandTech Scientific","offers":[{"title":"Default Title","offer_id":42644358299907,"sku":"20738003","price":10644.66,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale)","offer_id":42644358332675,"sku":"20738003","price":8515.73,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/20738003.jpg?v=1648832594"},{"product_id":"vacuubrand-rz-2-5-rotary-vane-vacuum-pump","title":"VACUUBRAND RZ 2.5 Rotary Vane Vacuum Pump Two-Stage","description":"\u003cp style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eBrandTech™ VACUUBRAND™ RZ 2.5  Two Stage Rotary Vane Vacuum Pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eVACUUBRAND\u003c\/span\u003e\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e RZ 2.5 \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eRotary Vane Vacuum Pumps have been designed from the ground up for the best performance in laboratory applications. \u003c\/span\u003eFor applications requiring a greater vacuum depth than an oil-free diaphragm pump can provide, BrandTech\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eoffers rotary vane pumps. They are extremely low noise and low vibration, even compared to earlier VACUUBRAND\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003erotary vane models.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eRugged\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eExceptional tolerance to water vapor with minimal impact on ultimate vacuum.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eEnergy Efficient\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eLow power consumption and low levels of waste heat generation compared to competitive models.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eCompact\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eTake up less space and weigh less than comparable models.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eReliability\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eAll VACUUBRAND\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003epumps and systems must pass rigorous product testing before leaving the factory. It's your assurance of a reliable pump.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.6181%;\"\u003e \u003cstrong\u003eTechnical Data\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 51%;\"\u003e\u003cstrong\u003eRZ 2.5\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.6181%;\"\u003eNumber of Stages\u003c\/td\u003e\n\u003ctd style=\"width: 51%;\"\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.6181%;\"\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51%;\"\u003e\n\u003cp\u003e2.3\/2.8\u003cspan data-mce-fragment=\"1\"\u003em3\/h\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.6181%;\"\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51%;\"\u003e\n\u003cp\u003e1.4\/1.6\u003cspan data-mce-fragment=\"1\"\u003ecfm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.6181%;\"\u003eUltimate partial vacuum (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 51%;\"\u003e\n\u003cp\u003e4 x 10\u003csup\u003e-4\u003cspan data-mce-fragment=\"1\"\u003embar\u003c\/span\u003e\u003c\/sup\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.6181%;\"\u003eUltimate Vacuum (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 51%;\"\u003e\n\u003cp\u003e2 x 10\u003csup\u003e-3\u003c\/sup\u003e\/1.5 x 10\u003csup\u003e-3\u003cspan data-mce-fragment=\"1\"\u003embar\u003c\/span\u003e\u003c\/sup\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.6181%;\"\u003eUltimate Vacuum (abs.) with Gas Ballast\u003c\/td\u003e\n\u003ctd style=\"width: 51%;\"\u003e\n\u003cp\u003e1 x 10\u003csup\u003e-2\u003c\/sup\u003e\/0.75 x 10\u003csup\u003e-2\u003cspan data-mce-fragment=\"1\"\u003embar\u003c\/span\u003e\u003c\/sup\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.6181%;\"\u003eWater Vapor Tolerance with Gas Ballast\u003c\/td\u003e\n\u003ctd style=\"width: 51%;\"\u003e\n\u003cp\u003e40\u003cspan data-mce-fragment=\"1\"\u003embar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.6181%;\"\u003eAmbient Temperature Range (operation)\u003c\/td\u003e\n\u003ctd style=\"width: 51%;\"\u003e\n\u003cp\u003e12 - 40\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.6181%;\"\u003eAmbient Temperature Range (storage)\u003c\/td\u003e\n\u003ctd style=\"width: 51%;\"\u003e\n\u003cp\u003e-10 - 60\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.6181%;\"\u003eOil Capacity (B-Oil) min.\/max.\u003c\/td\u003e\n\u003ctd style=\"width: 51%;\"\u003e\n\u003cp\u003e0.1\/0.25\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.6181%;\"\u003eMax. Back Pressure (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 51%;\"\u003e\n\u003cp\u003e1.1\u003cspan data-mce-fragment=\"1\"\u003ebar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.6181%;\"\u003eInlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 51%;\"\u003e\n\u003cp\u003esmall flange KF DN 16\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.6181%;\"\u003eOutlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 51%;\"\u003e\n\u003cp\u003eHose Nozzle DN-10mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.6181%;\"\u003eRated Motor Power\u003c\/td\u003e\n\u003ctd style=\"width: 51%;\"\u003e\n\u003cp\u003e0.18\u003cspan data-mce-fragment=\"1\"\u003ekW\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.6181%;\"\u003eRated Motor Speed at 50\/60 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 51%;\"\u003e\n\u003cp\u003e1500\/1800\u003cspan data-mce-fragment=\"1\"\u003emin-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.6181%;\"\u003eProtection Class\u003c\/td\u003e\n\u003ctd style=\"width: 51%;\"\u003e\n\u003cp\u003eIP 40\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.6181%;\"\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd style=\"width: 51%;\"\u003e\n\u003cp\u003e316 x 125 x 190\u003cspan data-mce-fragment=\"1\"\u003emm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.6181%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 51%;\"\u003e\n\u003cp\u003e11.4\u003cspan data-mce-fragment=\"1\"\u003ekg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.6181%;\"\u003eNoise Level at 50 Hz, typ.\u003c\/td\u003e\n\u003ctd style=\"width: 51%;\"\u003e\n\u003cp\u003e43\u003cspan data-mce-fragment=\"1\"\u003edBA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.6181%;\"\u003eItems Supplied\u003c\/td\u003e\n\u003ctd style=\"width: 51%;\"\u003e\n\u003cp\u003ePump oil filled and completely mounted, ready for use, w\/ manual\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/XS-series_Flyer_BT.pdf?v=1674666849\" target=\"_blank\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"BrandTech Scientific","offers":[{"title":"Default Title","offer_id":42644616184067,"sku":"20698126","price":179.7,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale)","offer_id":42644616216835,"sku":"20698126","price":3807.03,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/20698126.jpg?v=1648842639"},{"product_id":"vacuubrand-rz-6-two-stage-rotary-vane-vacuum-pump","title":"VACUUBRAND RZ 6 Rotary Vane Vacuum Pump Two-Stage","description":"\u003cp style=\"text-align: center;\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eBrandTech™ VACUUBRAND™ RZ 6 Two Stage Rotary Vane Vacuum Pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eVACUUBRAND\u003c\/span\u003e\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e RZ 6 \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eRotary Vane Vacuum Pumps have been designed from the ground up for the best performance in laboratory applications. \u003c\/span\u003eFor applications requiring a greater vacuum depth than an oil-free diaphragm pump can provide, BrandTech\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eoffers rotary vane pumps. They are extremely low noise and low vibration, even compared to earlier VACUUBRAND\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003erotary vane models.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged\u003c\/strong\u003e\u003cbr\u003eExceptional tolerance to water vapor with minimal impact on ultimate vacuum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy Efficient\u003c\/strong\u003e\u003cbr\u003eLow power consumption and low levels of waste heat generation compared to competitive models.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact\u003c\/strong\u003e\u003cbr\u003eTake up less space and weigh less than comparable models.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliability\u003c\/strong\u003e\u003cbr\u003eAll VACUUBRAND\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003epumps and systems must pass rigorous product testing before leaving the factory. It's your assurance of a reliable pump.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 52.113%;\"\u003e \u003cstrong\u003eTechnical Data\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 53.887%;\"\u003e\u003cstrong\u003eRZ 6\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 52.113%;\"\u003eNumber of Stages\u003c\/td\u003e\n\u003ctd style=\"width: 53.887%;\"\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 52.113%;\"\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.887%;\"\u003e\n\u003cp\u003e5.7\/6.8\u003cspan data-mce-fragment=\"1\"\u003em3\/h\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 52.113%;\"\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.887%;\"\u003e\n\u003cp\u003e3.4\/4.0\u003cspan data-mce-fragment=\"1\"\u003ecfm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 52.113%;\"\u003eUltimate partial vacuum (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 53.887%;\"\u003e\n\u003cp\u003e4 x 10\u003csup\u003e-4\u003cspan data-mce-fragment=\"1\"\u003embar\u003c\/span\u003e\u003c\/sup\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 52.113%;\"\u003eUltimate Vacuum (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 53.887%;\"\u003e\n\u003cp\u003e2 x 10\u003csup\u003e-3\u003c\/sup\u003e\/1.5 x 10\u003csup\u003e-3\u003cspan data-mce-fragment=\"1\"\u003embar\/torr\u003c\/span\u003e\u003c\/sup\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 52.113%;\"\u003eUltimate Vacuum (abs.) with Gas Ballast\u003c\/td\u003e\n\u003ctd style=\"width: 53.887%;\"\u003e\n\u003cp\u003e1 x 10\u003csup\u003e-2\u003c\/sup\u003e\/0.75 x 10\u003csup\u003e-2\u003cspan data-mce-fragment=\"1\"\u003embar\/torr\u003c\/span\u003e\u003c\/sup\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 52.113%;\"\u003eWater Vapor Tolerance with Gas Ballast\u003c\/td\u003e\n\u003ctd style=\"width: 53.887%;\"\u003e\n\u003cp\u003e40\u003cspan data-mce-fragment=\"1\"\u003embar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 52.113%;\"\u003eAmbient Temperature Range (operation)\u003c\/td\u003e\n\u003ctd style=\"width: 53.887%;\"\u003e\n\u003cp\u003e12 - 40\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 52.113%;\"\u003eAmbient Temperature Range (storage)\u003c\/td\u003e\n\u003ctd style=\"width: 53.887%;\"\u003e\n\u003cp\u003e-10 - 60\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 52.113%;\"\u003eOil Capacity (B-Oil) min.\/max.\u003c\/td\u003e\n\u003ctd style=\"width: 53.887%;\"\u003e\n\u003cp\u003e0.34\/0.65\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 52.113%;\"\u003eMax. Back Pressure (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 53.887%;\"\u003e\n\u003cp\u003e1.1\u003cspan data-mce-fragment=\"1\"\u003ebar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 52.113%;\"\u003eInlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 53.887%;\"\u003e\n\u003cp\u003esmall flange KF DN 16\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 52.113%;\"\u003eOutlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 53.887%;\"\u003e\n\u003cp\u003eHose Nozzle DN 8-10mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 52.113%;\"\u003eRated Motor Power\u003c\/td\u003e\n\u003ctd style=\"width: 53.887%;\"\u003e\n\u003cp\u003e0.3\u003cspan data-mce-fragment=\"1\"\u003ekW\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 52.113%;\"\u003eRated Motor Speed at 50\/60 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 53.887%;\"\u003e\n\u003cp\u003e1500\/1800\u003cspan data-mce-fragment=\"1\"\u003emin-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 52.113%;\"\u003eProtection Class\u003c\/td\u003e\n\u003ctd style=\"width: 53.887%;\"\u003e\n\u003cp\u003eIP 40\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 52.113%;\"\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd style=\"width: 53.887%;\"\u003e\n\u003cp\u003e370 x 142 x 207\u003cspan data-mce-fragment=\"1\"\u003emm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 52.113%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 53.887%;\"\u003e\n\u003cp\u003e16.4\u003cspan data-mce-fragment=\"1\"\u003ekg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 52.113%;\"\u003eNoise Level at 50 Hz, typ.\u003c\/td\u003e\n\u003ctd style=\"width: 53.887%;\"\u003e\n\u003cp\u003e50\u003cspan data-mce-fragment=\"1\"\u003edBA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 52.113%;\"\u003eItems Supplied\u003c\/td\u003e\n\u003ctd style=\"width: 53.887%;\"\u003e\n\u003cp\u003ePump oil filled and completely mounted, ready for use, w\/ manual\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/XS-series_Flyer_BT.pdf?v=1674666849\" title=\"Datasheet\" target=\"_blank\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\u003c\/ul\u003e","brand":"BrandTech Scientific","offers":[{"title":"Default Title","offer_id":42644757676291,"sku":"20698136","price":7779.04,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale)","offer_id":42644757709059,"sku":"20698136","price":6223.23,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/20698136.jpg?v=1648844461"},{"product_id":"vacuubrand-me1c-chemistry-diaphragm-vacuum-pump","title":"VACUUBRAND ME 1C Chemistry Diaphragm Vacuum Pump","description":"\u003cp style=\"text-align: center;\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eBrandTech™ VACUUBRAND™ ME 1C Diaphragm Vacuum Pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eVACUUBRAND™ ME 1C Compact Vacuum Pumps are designed for excellent corrosion resistance in routine biology and chemistry lab applications.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExcellent Corrosion Resistance\u003c\/strong\u003e\u003cbr\u003eVACUUBRAND\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eOil-free Chemistry Diaphragm Vacuum Pumps are constructed of materials with excellent corrosion resistance, such as PTFE heads and diaphragms. All multistage pumps are equipped with a gas ballast to provide consistent pump performance with condensed vapors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Oil Changes\u003c\/strong\u003e\u003cbr\u003eThese vacuum pumps utilize diaphragm vacuum technology. The totally dry operation eliminates the misting, handling and disposal of contaminated waste associated with rotary vane pumps. No oil to change or monitor!\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduced Maintenance\u003c\/strong\u003e\u003cbr\u003eTypical diaphragm lifetimes are well in excess of 15,000 hours of use before replacement - that's years in most applications, minimizing downtime and service costs. When it is finally time for service, their unique design eliminates tedious, trial-and-error stroke length recalibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImproved Productivity\u003c\/strong\u003e\u003cbr\u003eVACUUBRAND\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003epumps are engineered for performance, with flow rates as much as 40% higher at working vacuum level than competitive pumps with similar free air capacity ratings. Higher flow rates mean reduced process times and higher throughput.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet \u0026amp; Reliable\u003c\/strong\u003e\u003cbr\u003eVACUUBRAND\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003epumps offer whisper-quiet operation and low vibration. Plus, all VACUUBRAND\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003epumps and systems must pass rigorous product testing before leaving the factory. It's your assurance of a reliable pump.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6313%;\"\u003e \u003cstrong\u003eTechnical Data\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003e\u003cb\u003eME1C\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6313%;\"\u003eNumber of Heads\/Stages\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003e\n\u003cp\u003e1\/1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6313%;\"\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003e\n\u003cp\u003e0.7\/0.8\u003cspan data-mce-fragment=\"1\"\u003em3\/h\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6313%;\"\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003e\n\u003cp\u003e0.4\/0.5\u003cspan data-mce-fragment=\"1\"\u003ecfm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6313%;\"\u003eUltimate Vacuum (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003e\n\u003cp\u003e100\/75\u003cspan data-mce-fragment=\"1\"\u003embar\/torr\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6313%;\"\u003eAmbient Temperature Range (operation)\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003e\n\u003cp\u003e10 - 40\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6313%;\"\u003eAmbient Temperature Range (storage)\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003e\n\u003cp\u003e-10 - 60\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6313%;\"\u003eMax. Back Pressure (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003e\n\u003cp\u003e1.1\u003cspan data-mce-fragment=\"1\"\u003ebar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6313%;\"\u003eInlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003e\n\u003cp\u003eHose Nozzle DN 8-10mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6313%;\"\u003eOutlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003e\n\u003cp\u003e\u003cspan\u003eHose Nozzle DN 8-10mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6313%;\"\u003eRated Motor Power\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003e\n\u003cp\u003e0.04\u003cspan data-mce-fragment=\"1\"\u003ekW\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6313%;\"\u003eRated Motor Speed at 50\/60 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003e\n\u003cp\u003e1500\/1800\u003cspan data-mce-fragment=\"1\"\u003emin-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6313%;\"\u003eProtection Class\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003e\n\u003cp\u003eIP 40\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6313%;\"\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003e\n\u003cp\u003e247 x 121 x 145\u003cspan data-mce-fragment=\"1\"\u003emm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6313%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003e\n\u003cp\u003e5.4\u003cspan data-mce-fragment=\"1\"\u003ekg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6313%;\"\u003eNoise Level at 50 Hz, typ.\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003e\n\u003cp\u003e49\u003cspan data-mce-fragment=\"1\"\u003edBA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6313%;\"\u003eNRTL Certification\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003e\n\u003cp\u003eCanada and the USA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6313%;\"\u003eATEX Conformity (only 230V)\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003e\n\u003cp\u003eII 3\/-G Ex h IIC T3 Gc X Internal Atm. only\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6313%;\"\u003eItems Supplied\u003c\/td\u003e\n\u003ctd style=\"width: 50%;\"\u003e\n\u003cp\u003ePump oil filled and completely mounted, ready for use, w\/ manual\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"ME1C Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/ME1_ME1C_FLY_BT.pdf?v=1674667061\" target=\"_blank\"\u003e Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"BrandTech Scientific","offers":[{"title":"Default Title","offer_id":42654622646531,"sku":"20721103","price":2341.69,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale)","offer_id":42654622679299,"sku":"20721103","price":1873.35,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/20721103.jpg?v=1649171176"},{"product_id":"vacuubrand-me-2c-nt-oil-free-chemistry-vacuum-pump","title":"VACUUBRAND ME 2C NT Oil-Free Chemistry Vacuum Pump","description":"\u003cp style=\"text-align: center;\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eBrandTech™ VACUUBRAND™ ME 2C NT Chemistry Diaphragm Vacuum Pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eVACUUBRAND™ ME 2C NT Oil-Free Chemistry Diaphragm Vacuum Pumps are designed for excellent corrosion resistance in routine biology and chemistry lab applications. Chemistry-design diaphragm pumps are an excellent solution for continuous, oil-free pumping of aggressive gases and vapors and meet the highest demands. \u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe new NT-series of pumps provide whisper-quiet and ultra-low-vibration operation, high leak-tightness and improved vacuum. The highly flexible, fabric-reinforced double diaphragm made of FKM offers extended operation life.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExcellent Corrosion Resistance\u003c\/strong\u003e\u003cbr\u003eVACUUBRAND\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eOil-free Chemistry Diaphragm Vacuum Pumps are constructed of materials with excellent corrosion resistance, such as PTFE heads and diaphragms. All multistage pumps are equipped with a gas ballast to provide consistent pump performance with condensed vapors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Oil Changes\u003c\/strong\u003e\u003cbr\u003eThese vacuum pumps utilize diaphragm vacuum technology. The totally dry operation eliminates the misting, handling and disposal of contaminated waste associated with rotary vane pumps. No oil to change or monitor!\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduced Maintenance\u003c\/strong\u003e\u003cbr\u003eTypical diaphragm lifetimes are well in excess of 15,000 hours of use before replacement - that's years in most applications, minimizing downtime and service costs. When it is finally time for service, their unique design eliminates tedious, trial-and-error stroke length recalibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImproved Productivity\u003c\/strong\u003e\u003cbr\u003eVACUUBRAND\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003epumps are engineered for performance, with flow rates as much as 40% higher at working vacuum level than competitive pumps with similar free air capacity ratings. Higher flow rates mean reduced process times and higher throughput.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet \u0026amp; Reliable\u003c\/strong\u003e\u003cbr\u003eVACUUBRAND\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003epumps offer whisper-quiet operation and low vibration. Plus, all VACUUBRAND\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003epumps and systems must pass rigorous product testing before leaving the factory. It's your assurance of a reliable pump.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.3681%;\"\u003e \u003cstrong\u003eTechnical Data\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 49.5126%;\"\u003e\u003cb\u003eME2C\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.3681%;\"\u003eNumber of Heads\/Stages\u003c\/td\u003e\n\u003ctd style=\"width: 49.5126%;\"\u003e\n\u003cp\u003e1\/1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.3681%;\"\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.5126%;\"\u003e\n\u003cp\u003e2.1\/2.4\u003cspan data-mce-fragment=\"1\"\u003em3\/h\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.3681%;\"\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.5126%;\"\u003e\n\u003cp\u003e1.2\/1.4\u003cspan data-mce-fragment=\"1\"\u003ecfm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.3681%;\"\u003eUltimate Vacuum (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 49.5126%;\"\u003e\n\u003cp\u003e70\/52\u003cspan data-mce-fragment=\"1\"\u003embar\/torr\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.3681%;\"\u003eAmbient Temperature Range (operation)\u003c\/td\u003e\n\u003ctd style=\"width: 49.5126%;\"\u003e\n\u003cp\u003e10 - 40\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.3681%;\"\u003eAmbient Temperature Range (storage)\u003c\/td\u003e\n\u003ctd style=\"width: 49.5126%;\"\u003e\n\u003cp\u003e-10 - 60\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.3681%;\"\u003eMax. Back Pressure (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 49.5126%;\"\u003e\n\u003cp\u003e1.1bar\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.3681%;\"\u003eInlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 49.5126%;\"\u003e\n\u003cp\u003eHose Nozzle DN 8-10mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.3681%;\"\u003eOutlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 49.5126%;\"\u003e\n\u003cp\u003e\u003cspan\u003eHose Nozzle DN 8-10mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.3681%;\"\u003eRated Motor Power\u003c\/td\u003e\n\u003ctd style=\"width: 49.5126%;\"\u003e\n\u003cp\u003e0.18kW\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.3681%;\"\u003eRated Motor Speed at 50\/60 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 49.5126%;\"\u003e\n\u003cp\u003e1500\/1800\u003cspan data-mce-fragment=\"1\"\u003emin-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.3681%;\"\u003eProtection Class\u003c\/td\u003e\n\u003ctd style=\"width: 49.5126%;\"\u003e\n\u003cp\u003eIP 40\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.3681%;\"\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd style=\"width: 49.5126%;\"\u003e\n\u003cp\u003e243 x 211 x 198mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.3681%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 49.5126%;\"\u003e\n\u003cp\u003e10.2kg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.3681%;\"\u003eNoise Level at 50 Hz, typ.\u003c\/td\u003e\n\u003ctd style=\"width: 49.5126%;\"\u003e\n\u003cp\u003e45dBA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.3681%;\"\u003eNRTL Certification\u003c\/td\u003e\n\u003ctd style=\"width: 49.5126%;\"\u003e\n\u003cp\u003eCanada and the USA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.3681%;\"\u003eATEX Conformity (only 230V)\u003c\/td\u003e\n\u003ctd style=\"width: 49.5126%;\"\u003e\n\u003cp\u003eII 3\/-G Ex h IIC T3 Gc X Internal Atm. only\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.3681%;\"\u003eItems Supplied\u003c\/td\u003e\n\u003ctd style=\"width: 49.5126%;\"\u003e\n\u003cp\u003ePump oil filled and completely mounted, ready for use, w\/ manual\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Literature:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"ME2C NT - Brochure\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/Chemistry_diaphragm_pumps_brochure_2.pdf?v=1680188401\" target=\"_blank\"\u003eME2C NT - Brochure\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/Pumps_selection-Guide.pdf?v=1680188986\" title=\"ME2C NT - Selection Guide\" target=\"_blank\"\u003eME2C NT - Selection Guide\u003c\/a\u003e\u003c\/p\u003e","brand":"BrandTech Scientific","offers":[{"title":"Default Title","offer_id":42654640537859,"sku":"20730103","price":4608.41,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale)","offer_id":42654640570627,"sku":"20730103","price":3686.73,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/20730103.jpg?v=1649171960"},{"product_id":"vacuubrand-me-4c-nt-oil-free-chemistry-vacuum-pump","title":"VACUUBRAND ME 4C NT Oil-Free Chemistry Vacuum Pump","description":"\u003cp style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eBrandTech™ VACUUBRAND™ ME 4C NT Chemistry Diaphragm Pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eVACUUBRAND™ ME 4C NT Chemistry Diaphragm Pumps are designed for excellent corrosion resistance in routine biology and chemistry lab applications. \u003cspan data-mce-fragment=\"1\"\u003eChemistry-design diaphragm pumps are an excellent solution for continuous, oil-free pumping of aggressive gases and vapors and meet the highest demands. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe new NT-series of pumps provide whisper-quiet and ultra-low-vibration operation, high leak-tightness and improved vacuum. The highly flexible, fabric-reinforced double diaphragm made of FKM offers extended operation life.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eExcellent Corrosion Resistance\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eVACUUBRAND\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOil-free Chemistry Diaphragm Vacuum Pumps are constructed of materials with excellent corrosion resistance, such as PTFE heads and diaphragms. All multistage pumps are equipped with a gas ballast to provide consistent pump performance with condensed vapors.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eNo Oil Changes\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eThese vacuum pumps utilize diaphragm vacuum technology. The totally dry operation eliminates the misting, handling and disposal of contaminated waste associated with rotary vane pumps. No oil to change or monitor!\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eReduced Maintenance\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eTypical diaphragm lifetimes are well in excess of 15,000 hours of use before replacement - that's years in most applications, minimizing downtime and service costs. When it is finally time for service, their unique design eliminates tedious, trial-and-error stroke length recalibration.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eImproved Productivity\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eVACUUBRAND\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003epumps are engineered for performance, with flow rates as much as 40% higher at working vacuum level than competitive pumps with similar free air capacity ratings. Higher flow rates mean reduced process times and higher throughput.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eQuiet \u0026amp; Reliable\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eVACUUBRAND\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003epumps offer whisper-quiet operation and low vibration. Plus, all VACUUBRAND\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003epumps and systems must pass rigorous product testing before leaving the factory. It's your assurance of a reliable pump.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.68%;\"\u003e \u003cstrong\u003eTechnical Data\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 55.2007%;\"\u003e\u003cb\u003eME4C NT\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.68%;\"\u003eNumber of Heads\/Stages\u003c\/td\u003e\n\u003ctd style=\"width: 55.2007%;\"\u003e\n\u003cp\u003e2\/1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.68%;\"\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.2007%;\"\u003e\n\u003cp\u003e3.9\/4.3\u003cspan data-mce-fragment=\"1\"\u003em3\/h\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.68%;\"\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.2007%;\"\u003e\n\u003cp\u003e2.3\/2.5\u003cspan data-mce-fragment=\"1\"\u003ecfm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.68%;\"\u003eUltimate Vacuum (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 55.2007%;\"\u003e\n\u003cp\u003e70\/52\u003cspan data-mce-fragment=\"1\"\u003embar\/torr\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.68%;\"\u003eAmbient Temperature Range (operation)\u003c\/td\u003e\n\u003ctd style=\"width: 55.2007%;\"\u003e\n\u003cp\u003e10 - 40\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.68%;\"\u003eAmbient Temperature Range (storage)\u003c\/td\u003e\n\u003ctd style=\"width: 55.2007%;\"\u003e\n\u003cp\u003e-10 - 60\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.68%;\"\u003eMax. Back Pressure (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 55.2007%;\"\u003e\n\u003cp\u003e1.1\u003cspan data-mce-fragment=\"1\"\u003ebar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.68%;\"\u003eInlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 55.2007%;\"\u003e\n\u003cp\u003eHose Nozzle DN 8-10mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.68%;\"\u003eOutlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 55.2007%;\"\u003e\n\u003cp\u003e\u003cspan\u003eHose Nozzle DN 8-10mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.68%;\"\u003eRated Motor Power\u003c\/td\u003e\n\u003ctd style=\"width: 55.2007%;\"\u003e\n\u003cp\u003e0.18kW\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.68%;\"\u003eRated Motor Speed at 50\/60 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 55.2007%;\"\u003e\n\u003cp\u003e1500\/1800\u003cspan data-mce-fragment=\"1\"\u003emin-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.68%;\"\u003eProtection Class\u003c\/td\u003e\n\u003ctd style=\"width: 55.2007%;\"\u003e\n\u003cp\u003eIP 40\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.68%;\"\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd style=\"width: 55.2007%;\"\u003e\n\u003cp\u003e254 x 243 x 198mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.68%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 55.2007%;\"\u003e\n\u003cp\u003e11.1kg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.68%;\"\u003eNoise Level at 50 Hz, typ.\u003c\/td\u003e\n\u003ctd style=\"width: 55.2007%;\"\u003e\n\u003cp\u003e45dBA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.68%;\"\u003eNRTL Certification\u003c\/td\u003e\n\u003ctd style=\"width: 55.2007%;\"\u003e\n\u003cp\u003eCanada and the USA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.68%;\"\u003eATEX Conformity (only 230V)\u003c\/td\u003e\n\u003ctd style=\"width: 55.2007%;\"\u003e\n\u003cp\u003eII 3\/-G Ex h IIC T3 X Internal Atm. only\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.68%;\"\u003eItems Supplied\u003c\/td\u003e\n\u003ctd style=\"width: 55.2007%;\"\u003e\n\u003cp\u003ePump oil filled and completely mounted, ready for use, w\/ manual\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Literature:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"ME 4C NT - Brochure\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/Chemistry_diaphragm_pumps_brochure_2.pdf?v=1680188401\" target=\"_blank\"\u003eME 4C NT - Brochure\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"ME 4C NT - Selection Guide\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/Pumps_selection-Guide.pdf?v=1680188986\" target=\"_blank\"\u003eME 4C NT - Selection Guide\u003c\/a\u003e\u003c\/p\u003e","brand":"BrandTech Scientific","offers":[{"title":"Default Title","offer_id":42654757093635,"sku":"20731203","price":6833.19,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale)","offer_id":42654757126403,"sku":"20731203","price":5466.55,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/20731203.jpg?v=1649174752"},{"product_id":"vacuubrand-me-8c-nt-dry-oil-free-chemistry-vacuum-pump","title":"VACUUBRAND ME 8C NT Dry Oil-Free Chemistry Vacuum Pump","description":"\u003cp style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eBrandTech™ VACUUBRAND™ ME 8C NT Dry Chemistry Diaphragm Pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eVACUUBRAND™ ME 8C NT Dry Chemistry Diaphragm Pumps are designed for excellent corrosion resistance in routine biology and chemistry lab applications. \u003cspan data-mce-fragment=\"1\"\u003eChemistry-design diaphragm pumps are an excellent solution for continuous, oil-free pumping of aggressive gases and vapors and meet the highest demands. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe new NT-series of pumps provide whisper-quiet and ultra-low-vibration operation, high leak-tightness and improved vacuum. The highly flexible, fabric-reinforced double diaphragm made of FKM offers extended operation life.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eExcellent Corrosion Resistance\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eVACUUBRAND\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOil-free Chemistry Diaphragm Vacuum Pumps are constructed of materials with excellent corrosion resistance, such as PTFE heads and diaphragms. All multistage pumps are equipped with a gas ballast to provide consistent pump performance with condensed vapors.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eNo Oil Changes\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eThese vacuum pumps utilize diaphragm vacuum technology. The totally dry operation eliminates the misting, handling and disposal of contaminated waste associated with rotary vane pumps. No oil to change or monitor!\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eReduced Maintenance\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eTypical diaphragm lifetimes are well in excess of 15,000 hours of use before replacement - that's years in most applications, minimizing downtime and service costs. When it is finally time for service, their unique design eliminates tedious, trial-and-error stroke length recalibration.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eImproved Productivity\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eVACUUBRAND\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003epumps are engineered for performance, with flow rates as much as 40% higher at working vacuum level than competitive pumps with similar free air capacity ratings. Higher flow rates mean reduced process times and higher throughput.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eQuiet \u0026amp; Reliable\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eVACUUBRAND\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003epumps offer whisper-quiet operation and low vibration. Plus, all VACUUBRAND\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003epumps and systems must pass rigorous product testing before leaving the factory. It's your assurance of a reliable pump.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.3744%;\"\u003e \u003cstrong\u003eTechnical Data\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\u003cb\u003eME8C NT\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.3744%;\"\u003eNumber of Heads\/Stages\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e4\/1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.3744%;\"\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e7.1\/7.8\u003cspan data-mce-fragment=\"1\"\u003em3\/h\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.3744%;\"\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e4.2\/4.6\u003cspan data-mce-fragment=\"1\"\u003ecfm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.3744%;\"\u003eUltimate Vacuum (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e70\/52\u003cspan data-mce-fragment=\"1\"\u003embar\/torr\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.3744%;\"\u003eAmbient Temperature Range (operation)\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e10 - 40\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.3744%;\"\u003eAmbient Temperature Range (storage)\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e-10 - 60\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.3744%;\"\u003eMax. Back Pressure (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e1.1\u003cspan data-mce-fragment=\"1\"\u003ebar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.3744%;\"\u003eInlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003eHose Nozzle DN 8-10mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.3744%;\"\u003eOutlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e\u003cspan\u003eHose Nozzle DN 8-10mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.3744%;\"\u003eRated Motor Power\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e0.25\u003cspan data-mce-fragment=\"1\"\u003ekW\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.3744%;\"\u003eRated Motor Speed at 50\/60 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e1500\/1800\u003cspan data-mce-fragment=\"1\"\u003emin-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.3744%;\"\u003eProtection Class\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003eIP 40\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.3744%;\"\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e325 x 243 x 198\u003cspan data-mce-fragment=\"1\"\u003emm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.3744%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e14.3\u003cspan data-mce-fragment=\"1\"\u003ekg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.3744%;\"\u003eNoise Level at 50 Hz, typ.\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e45\u003cspan data-mce-fragment=\"1\"\u003edBA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.3744%;\"\u003eNRTL Certification\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003eCanada and the USA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.3744%;\"\u003eATEX Conformity (only 230V)\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003eII 3\/-G Ex h IIC T3 X Internal Atm. only\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.3744%;\"\u003eItems Supplied\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003ePump oil filled and completely mounted, ready for use, w\/ manual\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"ME 8C NT Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/Chemistry_diaphragm_pumps_brochure_1.pdf?v=1674679286\" target=\"_blank\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e","brand":"BrandTech Scientific","offers":[{"title":"Default Title","offer_id":42659052093699,"sku":"20734203","price":10239.29,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale)","offer_id":42659052126467,"sku":"20734203","price":8191.43,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/20734203.jpg?v=1649264468"},{"product_id":"vacuubrand-mz1c-dry-chemistry-diaphragm-vacuum-pump","title":"VACUUBRAND MZ 1C Dry Chemistry Diaphragm Vacuum Pump","description":"\u003cp style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eBrandTech™ VACUUBRAND™ MZ 1C Dry Chemistry Diaphragm Vacuum Pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eVACUUBRAND™ MZ 1C Dry Chemistry Diaphragm Vacuum Pumps are designed for excellent corrosion resistance in routine biology and chemistry lab applications.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eProduct Features:\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eExcellent Corrosion Resistance\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eVACUUBRAND™ MZ 1C Dry Chemistry Diaphragm Vacuum Pumps\u003c\/span\u003e are constructed of materials with excellent corrosion resistance, such as PTFE heads and diaphragms. All multistage pumps are equipped with a gas ballast to provide consistent pump performance with condensed vapors.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eNo Oil Changes\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eThese vacuum pumps utilize diaphragm vacuum technology. The totally dry operation eliminates the misting, handling and disposal of contaminated waste associated with rotary vane pumps. No oil to change or monitor!\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eReduced Maintenance\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eTypical diaphragm lifetimes are well in excess of 15,000 hours of use before replacement - that's years in most applications, minimizing downtime and service costs. When it is finally time for service, their unique design eliminates tedious, trial-and-error stroke length recalibration.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eImproved Productivity\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eVACUUBRAND\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003epumps are engineered for performance, with flow rates as much as 40% higher at working vacuum level than competitive pumps with similar free air capacity ratings. Higher flow rates mean reduced process times and higher throughput.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eQuiet \u0026amp; Reliable\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eVACUUBRAND\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003epumps offer whisper-quiet operation and low vibration. Plus, all VACUUBRAND\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003epumps and systems must pass rigorous product testing before leaving the factory. It's your assurance of a reliable pump.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.5975%;\"\u003e \u003cstrong\u003eTechnical Data\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.2833%;\"\u003e\u003cb\u003eMZ 1C\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.5975%;\"\u003eNumber of Heads\/Stages\u003c\/td\u003e\n\u003ctd style=\"width: 54.2833%;\"\u003e\n\u003cp\u003e2\/2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.5975%;\"\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2833%;\"\u003e\n\u003cp\u003e0.75\/0.9\u003cspan data-mce-fragment=\"1\"\u003em3\/h\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.5975%;\"\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2833%;\"\u003e\n\u003cp\u003e0.4\/0.5\u003cspan data-mce-fragment=\"1\"\u003ecfm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.5975%;\"\u003eUltimate Vacuum (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 54.2833%;\"\u003e\n\u003cp\u003e12\/9\u003cspan data-mce-fragment=\"1\"\u003embar\/torr\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.5975%;\"\u003eUltimate Vacuum (abs.) with Gas Ballast\u003c\/td\u003e\n\u003ctd style=\"width: 54.2833%;\"\u003e\n\u003cp\u003e20\/15\u003cspan data-mce-fragment=\"1\"\u003embar\/torr\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.5975%;\"\u003eAmbient Temperature Range (operation)\u003c\/td\u003e\n\u003ctd style=\"width: 54.2833%;\"\u003e\n\u003cp\u003e10 - 40\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.5975%;\"\u003eAmbient Temperature Range (storage)\u003c\/td\u003e\n\u003ctd style=\"width: 54.2833%;\"\u003e\n\u003cp\u003e-10 - 60\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.5975%;\"\u003eMax. Back Pressure (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 54.2833%;\"\u003e\n\u003cp\u003e1.1\u003cspan data-mce-fragment=\"1\"\u003ebar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.5975%;\"\u003eInlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 54.2833%;\"\u003e\n\u003cp\u003eHose Nozzle DN 8-10mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.5975%;\"\u003eOutlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 54.2833%;\"\u003e\n\u003cp\u003e\u003cspan\u003eHose Nozzle DN 8-10mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.5975%;\"\u003eRated Motor Power\u003c\/td\u003e\n\u003ctd style=\"width: 54.2833%;\"\u003e\n\u003cp\u003e0.06\u003cspan data-mce-fragment=\"1\"\u003ekW\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.5975%;\"\u003eRated Motor Speed at 50\/60 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 54.2833%;\"\u003e\n\u003cp\u003e1500\/1800\u003cspan data-mce-fragment=\"1\"\u003emin-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.5975%;\"\u003eProtection Class\u003c\/td\u003e\n\u003ctd style=\"width: 54.2833%;\"\u003e\n\u003cp\u003eIP 40\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.5975%;\"\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd style=\"width: 54.2833%;\"\u003e\n\u003cp\u003e312 x 121 x 170\u003cspan data-mce-fragment=\"1\"\u003emm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.5975%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 54.2833%;\"\u003e\n\u003cp\u003e6.7\u003cspan data-mce-fragment=\"1\"\u003ekg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.5975%;\"\u003eNoise Level at 50 Hz, typ.\u003c\/td\u003e\n\u003ctd style=\"width: 54.2833%;\"\u003e\n\u003cp\u003e45\u003cspan data-mce-fragment=\"1\"\u003edBA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.5975%;\"\u003eATEX Conformity (only 230V)\u003c\/td\u003e\n\u003ctd style=\"width: 54.2833%;\"\u003e\n\u003cp\u003eII 3\/-G Ex h IIC T3 Gc X Internal Atm. only\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.5975%;\"\u003eItems Supplied\u003c\/td\u003e\n\u003ctd style=\"width: 54.2833%;\"\u003e\n\u003cp\u003ePump oil filled and completely mounted, ready for use, w\/ manual\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/MZ1C_Flyer_BT.pdf?v=1674667182\" title=\"MZ1C Datasheet\" target=\"_blank\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"BrandTech Scientific","offers":[{"title":"Default Title","offer_id":42664458387715,"sku":"20724103","price":4582.01,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale)","offer_id":42664458420483,"sku":"20724103","price":3665.61,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/20724103.jpg?v=1649351528"},{"product_id":"vacuubrand-mz-2c-nt-oil-free-chemistry-vacuum-pump","title":"VACUUBRAND MZ 2C NT Oil-Free Chemistry Vacuum Pump","description":"\u003cp style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eBrandTech™ VACUUBRAND™ MZ 2C NT Chemistry Diaphragm Vacuum Pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eVACUUBRAND™ MZ 2C NT Chemistry Diaphragm Vacuum Pumps are designed for excellent corrosion resistance in routine biology and chemistry lab applications. \u003cspan data-mce-fragment=\"1\"\u003eChemistry-design diaphragm pumps are an excellent solution for continuous, oil-free pumping of aggressive gases and vapors and meet the highest demands. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe new NT-series of pumps provide whisper-quiet and ultra-low-vibration operation, high leak-tightness and improved vacuum. The highly flexible, fabric-reinforced double diaphragm made of FKM offers extended operation life.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eExcellent Corrosion Resistance\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eVACUUBRAND\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOil-free Chemistry Diaphragm Vacuum Pumps are constructed of materials with excellent corrosion resistance, such as PTFE heads and diaphragms. All multistage pumps are equipped with a gas ballast to provide consistent pump performance with condensed vapors.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eNo Oil Changes\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eThese vacuum pumps utilize diaphragm vacuum technology. The totally dry operation eliminates the misting, handling and disposal of contaminated waste associated with rotary vane pumps. No oil to change or monitor!\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eReduced Maintenance\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eTypical diaphragm lifetimes are well in excess of 15,000 hours of use before replacement - that's years in most applications, minimizing downtime and service costs. When it is finally time for service, their unique design eliminates tedious, trial-and-error stroke length recalibration.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eImproved Productivity\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eVACUUBRAND\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003epumps are engineered for performance, with flow rates as much as 40% higher at working vacuum level than competitive pumps with similar free air capacity ratings. Higher flow rates mean reduced process times and higher throughput.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eQuiet \u0026amp; Reliable\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eVACUUBRAND\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003epumps offer whisper-quiet operation and low vibration. Plus, all VACUUBRAND\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003epumps and systems must pass rigorous product testing before leaving the factory. It's your assurance of a reliable pump.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003e \u003cstrong\u003eTechnical Data\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\u003cb\u003eMZ 2C NT\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eNumber of Heads\/Stages\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e2\/2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e2.0\/2.3\u003cspan data-mce-fragment=\"1\"\u003em3\/h\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e1.2\/1.4\u003cspan data-mce-fragment=\"1\"\u003ecfm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eUltimate Vacuum (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e7\/5\u003cspan data-mce-fragment=\"1\"\u003embar\/torr\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eUltimate Vacuum (abs.) with Gas Ballast\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e12\/9\u003cspan data-mce-fragment=\"1\"\u003embar\/torr\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eAmbient Temperature Range (operation)\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e10 - 40\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eAmbient Temperature Range (storage)\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e-10 - 60\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eMax. Back Pressure (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e1.1\u003cspan data-mce-fragment=\"1\"\u003ebar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eInlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003eHose Nozzle DN 8-10mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eOutlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e\u003cspan\u003eHose Nozzle DN 8-10mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eRated Motor Power\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e0.18\u003cspan data-mce-fragment=\"1\"\u003ekW\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eRated Motor Speed at 50\/60 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e1500\/1800\u003cspan data-mce-fragment=\"1\"\u003emin-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eProtection Class\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003eIP 40\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e243 x 243 x 198\u003cspan data-mce-fragment=\"1\"\u003emm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e11.1\u003cspan data-mce-fragment=\"1\"\u003ekg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eNoise Level at 50 Hz, typ.\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e45\u003cspan data-mce-fragment=\"1\"\u003edBA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eNRTL Certification\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003eCanada and the USA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eATEX Conformity (only 230V)\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003eII 3\/-G Ex h IIC T3 X Internal Atm. only\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eItems Supplied\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003ePump oil filled and completely mounted, ready for use, w\/ manual\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"Chemistry-design%20diaphragm%20pumps%20are%20an%20excellent%20solution%20for%20continuous,%20oil-free%20pumping%20of%20aggressive%20gases%20and%20vapors%20and%20meet%20the%20highest%20demands.%20\" title=\"MZ 2C NT\" target=\"_blank\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"BrandTech Scientific","offers":[{"title":"Default Title","offer_id":42664507146499,"sku":"20732303","price":5387.04,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale)","offer_id":42664507179267,"sku":"20732303","price":4309.63,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/20732303.jpg?v=1649351912"},{"product_id":"vacuubrand-md-4c-nt-ak-synchro-ek-chemistry-vacuum-pump-system","title":"VACUUBRAND MD 4C NT+AK Synchro EK Chemistry Vacuum Pump System","description":"\u003cp data-mce-fragment=\"1\" style=\"text-align: center;\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eBrandTech™ VACUUBRAND™ MD 4C NT+AK Synchro™+EK Chemistry Vacuum Pump System\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eVACUUBRAND\u003c\/span\u003e\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e MD 4C NT Synchro™ chemistry vacuum pump systems utilizes an \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eoil-free chemistry design vacuum pump, with the option to enable two independent vacuum applications on a single pump to increase lab efficiency and reduce the cost of vacuum generation. Operating two different applications from a single pump saves money and lab bench space. Integrated check valves minimize interaction between applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe new NT-series of pumps provide whisper-quiet and ultra-low-vibration operation, high leak-tightness and improved vacuum. The highly flexible, fabric-reinforced double diaphragm made of FKM offers extended operation life.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe separator at the inlet (AK) is made of glass with protective coating and retains particles and liquid droplets. The compact emission condenser (EK) on the exhaust side is particularly effective. It enables almost 100% solvent recovery for economical reuse and active protection of the environment. Each vacuum port is designed with a flow-control valve for easy adjustment of the effective volume flow rate.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAK: Protection of the pump from particles and liquid droplets\u003c\/li\u003e\n\u003cli\u003eEK: excellent environmental credentials thanks to efficient solvent recovery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual Control\u003c\/strong\u003e\u003cbr\u003eA PTFE diaphragm valve provides approximate control of vacuum levels for less demanding applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronic Control\u003c\/strong\u003e\u003cbr\u003eA solenoid valve, operated by the new VACUU·SELECT controller, provides precise two-point electronic control for important applications, maintaining vacuum levels between pre-set tolerances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVACUU·SELECT\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003econtroller\u003c\/strong\u003e\u003cbr\u003eController has a touch screen interface and predefined applications. It is easy-to-use and the modification of existing applications, or creation of new applications, is simple with drag-and-drop editing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Oil Changes\u003c\/strong\u003e\u003cbr\u003eThese vacuum pumps utilize diaphragm vacuum technology. The totally dry operation eliminates the misting, handling and disposal of contaminated waste associated with rotary vane pumps. No oil to change or monitor!\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduced Maintenance\u003c\/strong\u003e\u003cbr\u003eTypical diaphragm lifetimes are well in excess of 15,000 hours of use before replacement - that's years in most applications, minimizing downtime and service costs. When it is finally time for service, their unique design eliminates tedious, trial-and-error stroke length recalibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImproved Productivity\u003c\/strong\u003e\u003cbr\u003eVACUUBRAND\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003epumps are engineered for performance, with flow rates as much as 40% higher at working vacuum level than competitive pumps with similar free air capacity ratings. Higher flow rates mean reduced process times and higher throughput.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliability\u003c\/strong\u003e\u003cbr\u003eAll VACUUBRAND\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003epumps and systems must pass rigorous product testing before leaving the factory. It's your assurance of a reliable pump.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003cstrong\u003eTechnical Data\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMD 4C NT Synchro™\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Heads\/Stages\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\/3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e3.4\/3.8 m3\/h\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2.0\/2.2 cfm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltimate Vacuum (abs.)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1.5\/1.1 mbar\/torr\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltimate Vacuum (abs.) with Gas Ballast\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e3\/2.2 mbar\/torr\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature Range (operation)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10 - 40\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature Range (storage)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-10 - 60\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Back Pressure (abs.)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1.1 bar\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInlet Connection\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 x Hose Nozzle DN 8-10mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Connection\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eHose Nozzle DN 8-10mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoolant Connection\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x Hose Nozzle DN 6-8mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Motor Power\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.25 kW\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Motor Speed at 50\/60 Hz\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1500\/1800 \u003cspan data-mce-fragment=\"1\"\u003emin-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIP 40\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e326 x 248 x 402mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e17.6 kg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Level at 50 Hz, typ.\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e45 dBA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNRTL Certification\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCanada and the USA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"BrandTech Scientific","offers":[{"title":"Default Title","offer_id":43729813143811,"sku":"20736803","price":14021.95,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale)","offer_id":43729813176579,"sku":"20736803","price":11217.56,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/MD4CNT-AKSynchro-EK.png?v=1686341211"},{"product_id":"vacuubrand-mz-2c-nt-ak-synchro-ek-chemistry-vacuum-pump-system","title":"VACUUBRAND MZ 2C NT+AK Synchro EK Chemistry Vacuum Pump System","description":"\u003cp data-mce-fragment=\"1\" style=\"text-align: center;\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eBrandTech™ VACUUBRAND™ MZ 2C NT+AK Synchro™+EK Dual Application Vacuum Pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eVACUUBRAND\u003c\/span\u003e\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e MZ 2C NT Synchro™\u003cstrong data-mce-fragment=\"1\"\u003e \u003c\/strong\u003eDual Application Vacuum Pumps utilize VACUUBRAND\u003c\/span\u003e\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e Oil-free Chemistry Design Vacuum Pumps to increase lab efficiency and reduce the cost of vacuum generation. Operating two different applications from a single pump saves money and lab bench space. These vacuum systems are available with manual control, electronic control or both. Integrated check valves minimize interaction between applications.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual Control\u003c\/strong\u003e\u003cbr\u003eA PTFE diaphragm valve provides approximate control of vacuum levels for less demanding applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronic Control\u003c\/strong\u003e\u003cbr\u003eA solenoid valve, operated by the new VACUU·SELECT controller, provides precise two-point electronic control for important applications, maintaining vacuum levels between pre-set tolerances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVACUU·SELECT\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003econtroller\u003c\/strong\u003e\u003cbr\u003eController has a touch screen interface and predefined applications. It is easy-to-use and the modification of existing applications, or creation of new applications, is simple with drag-and-drop editing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Oil Changes\u003c\/strong\u003e\u003cbr\u003eThese vacuum pumps utilize diaphragm vacuum technology. The totally dry operation eliminates the misting, handling and disposal of contaminated waste associated with rotary vane pumps. No oil to change or monitor!\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduced Maintenance\u003c\/strong\u003e\u003cbr\u003eTypical diaphragm lifetimes are well in excess of 15,000 hours of use before replacement - that's years in most applications, minimizing downtime and service costs. When it is finally time for service, their unique design eliminates tedious, trial-and-error stroke length recalibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImproved Productivity\u003c\/strong\u003e\u003cbr\u003eVACUUBRAND\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003epumps are engineered for performance, with flow rates as much as 40% higher at working vacuum level than competitive pumps with similar free air capacity ratings. Higher flow rates mean reduced process times and higher throughput.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliability\u003c\/strong\u003e\u003cbr\u003eAll VACUUBRAND\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003epumps and systems must pass rigorous product testing before leaving the factory. It's your assurance of a reliable pump.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003cstrong\u003eTechnical Data\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMZ 2C NT Synchro™\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Heads\/Stages\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\/2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2.0\/2.3 m3\/h\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1.2\/2.4 cfm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltimate Vacuum (abs.)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e7\/5 mbar\/torr\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltimate Vacuum (abs.) with Gas Ballast\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e12\/9 mbar\/torr\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature Range (operation)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10 - 40\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003eC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature Range (storage)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-10 - 60\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003eC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Back Pressure (abs.)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1.1bar\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInlet Connection\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 x Hose Nozzle DN 8-10mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Connection\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eHose Nozzle DN 8-10mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoolant Connection\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x Hose Nozzle DN 6-8mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Motor Power\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.18kW\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Motor Speed at 50\/60 Hz\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1500\/1800 min-1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIP 40\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e326 x 248 x 402 mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e14.5 kg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Level at 50 Hz, typ.\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e45dBA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNRTL Certification\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCanada and the USA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"BrandTech Scientific","offers":[{"title":"Default Title","offer_id":43742796218627,"sku":"20732803","price":11753.93,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale)","offer_id":43742796251395,"sku":"20732803","price":9403.15,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/Screenshot2023-02-15114850.png?v=1676479745"},{"product_id":"vacuubrand-pc-101-nt-oil-free-chemistry-vacuum-pump-manual","title":"VACUUBRAND PC 101 NT Oil-Free Chemistry Vacuum Pump Manual","description":"\u003cp style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eBrandTech™ VACUUBRAND™ PC 101 NT Manual Control Vacuum Pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\" data-mce-fragment=\"1\"\u003eBrandTech™ VACUUBRAND™ PC 101 NT Manual Control Vacuum Pumps provide the most basic management of vacuum where electronic control is unnecessary to achieve good results. Centrifugal concentration, gel drying, and even simple rotary evaporation applications can often be effectively managed with manual control systems. Excellent corrosion resistance with manual control in a single system.\u003c\/p\u003e\n\u003cp style=\"text-align: left;\" data-mce-fragment=\"1\"\u003e\u003cspan\u003eThe new NT-series of pumps provide whisper-quiet and ultra-low-vibration operation, high leak-tightness and improved vacuum. The highly flexible, fabric-reinforced double diaphragm made of FKM offers extended operation life.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual Control Valve\u003c\/strong\u003e\u003cbr\u003eA PTFE diaphragm valve provides approximate control of vacuum levels for less demanding applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Oil Changes\u003c\/strong\u003e\u003cbr\u003eThese vacuum pumps utilize diaphragm vacuum technology. The totally dry operation eliminates the misting, handling and disposal of contaminated waste associated with rotary vane pumps. No oil to change or monitor!\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduced Maintenance\u003c\/strong\u003e\u003cbr\u003eTypical diaphragm lifetimes are well in excess of 15,000 hours of use before replacement - that's years in most applications, minimizing downtime and service costs. When it is finally time for service, their unique design eliminates tedious, trial-and-error stroke length recalibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImproved Productivity\u003c\/strong\u003e\u003cbr\u003eVACUUBRAND\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003epumps are engineered for performance, with flow rates as much as 40% higher at working vacuum level than competitive pumps with similar free air capacity ratings. Higher flow rates mean reduced process times and higher throughput.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliability\u003c\/strong\u003e\u003cbr\u003eAll VACUUBRAND\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003epumps and systems must pass rigorous product testing before leaving the factory. It's your assurance of a reliable pump.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\" data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003ctable width=\"100%\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 50.9245%;\" data-mce-fragment=\"1\"\u003e \u003cstrong data-mce-fragment=\"1\"\u003eTechnical Data\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.0755%;\" data-mce-fragment=\"1\"\u003e\u003cb\u003ePC 101 NT\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 50.9245%;\" data-mce-fragment=\"1\"\u003eNumber of Heads\/Stages\u003c\/td\u003e\n\u003ctd style=\"width: 58.0755%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e2\/2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 50.9245%;\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.0755%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e2.0\/2.3\u003cspan data-mce-fragment=\"1\"\u003em3\/h\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 50.9245%;\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.0755%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e1.2\/1.4\u003cspan data-mce-fragment=\"1\"\u003ecfm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 50.9245%;\" data-mce-fragment=\"1\"\u003eUltimate Vacuum (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 58.0755%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e7\/5\u003cspan data-mce-fragment=\"1\"\u003embar\/torr\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 50.9245%;\" data-mce-fragment=\"1\"\u003e\u003cspan\u003eUltimate Vacuum (abs.) with gas ballast\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.0755%;\" data-mce-fragment=\"1\"\u003e12\/9\u003cspan data-mce-fragment=\"1\"\u003embar\/torr\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 50.9245%;\" data-mce-fragment=\"1\"\u003eAmbient Temperature Range (operation)\u003c\/td\u003e\n\u003ctd style=\"width: 58.0755%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e10 - 40\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 50.9245%;\" data-mce-fragment=\"1\"\u003eAmbient Temperature Range (storage)\u003c\/td\u003e\n\u003ctd style=\"width: 58.0755%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e-10 - 60\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 50.9245%;\" data-mce-fragment=\"1\"\u003eMax. Back Pressure (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 58.0755%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e1.1\u003cspan data-mce-fragment=\"1\"\u003ebar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 50.9245%;\" data-mce-fragment=\"1\"\u003eInlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 58.0755%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eHose Nozzle DN 8-10mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 50.9245%;\" data-mce-fragment=\"1\"\u003eOutlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 58.0755%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan\u003eHose Nozzle DN 8-10mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 50.9245%;\" data-mce-fragment=\"1\"\u003eCoolant Connection\u003c\/td\u003e\n\u003ctd style=\"width: 58.0755%;\" data-mce-fragment=\"1\"\u003e\u003cspan\u003e2 x Hose Nozzle DN 6-8mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 50.9245%;\" data-mce-fragment=\"1\"\u003eRated Motor Power\u003c\/td\u003e\n\u003ctd style=\"width: 58.0755%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e0.18\u003cspan data-mce-fragment=\"1\"\u003ekW\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 50.9245%;\" data-mce-fragment=\"1\"\u003eRated Motor Speed at 50\/60 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 58.0755%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e1500\/1800\u003cspan data-mce-fragment=\"1\"\u003emin-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 50.9245%;\" data-mce-fragment=\"1\"\u003eProtection Class\u003c\/td\u003e\n\u003ctd style=\"width: 58.0755%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eIP 40\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 50.9245%;\" data-mce-fragment=\"1\"\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd style=\"width: 58.0755%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e326 x 243 x 402\u003cspan data-mce-fragment=\"1\"\u003emm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 50.9245%;\" data-mce-fragment=\"1\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 58.0755%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e14.5\u003cspan data-mce-fragment=\"1\"\u003ekg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 50.9245%;\" data-mce-fragment=\"1\"\u003eNoise Level at 50 Hz, typ.\u003c\/td\u003e\n\u003ctd style=\"width: 58.0755%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e45\u003cspan data-mce-fragment=\"1\"\u003edBA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 50.9245%;\" data-mce-fragment=\"1\"\u003eNRTL Certification\u003c\/td\u003e\n\u003ctd style=\"width: 58.0755%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eCanada and the USA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"BrandTech Scientific","offers":[{"title":"Default Title","offer_id":43743084118275,"sku":"20733003","price":8934.52,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale)","offer_id":43743084151043,"sku":"20733003","price":7147.62,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/Screenshot2023-02-15151657.png?v=1676492338"},{"product_id":"vacuubrand-pc-510-vario-vacuu-select-chemistry-vacuum-pump","title":"VACUUBRAND PC 510 VARIO VACUU·SELECT Chemistry Vacuum Pump","description":"\u003cp style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eBrandTech™ VACUUBRAND™ PC 510 VARIO VACUU·SELECT Chemistry Pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\" data-mce-fragment=\"1\"\u003eVACUUBRAND™ PC 510 VARIO Select Electronic Control Chemistry Pump is an \u003cspan data-mce-fragment=\"1\"\u003eexcellent choice for supporting controlled evaporation or drying processes. The PC 510 select can be used for many common solvents.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\" data-mce-fragment=\"1\"\u003e\u003cspan\u003eEasy-to-use, the VACUU·SELECT\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e controller provides a touch screen, application-based interface. Creating a new application is as easy as swiping a finger to drag-and-drop application building blocks. These pumps are excellent choices for supporting controlled evaporation or drying processes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eVACUU·SELECT\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003econtroller\u003c\/strong\u003e\u003cbr\u003eController has a touch screen interface and predefined applications. It is easy-to-use and the modification of existing applications, or creation of new applications, is simple with drag-and-drop editing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronic Control\u003c\/strong\u003e\u003cbr\u003eA solenoid valve, operated by the new VACUU·SELECT controller, provides precise two-point electronic control for important applications, maintaining vacuum levels between pre-set tolerances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Oil Changes\u003c\/strong\u003e\u003cbr\u003eThese vacuum pumps utilize diaphragm vacuum technology. The totally dry operation eliminates the misting, handling and disposal of contaminated waste associated with rotary vane pumps. No oil to change or monitor!\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduced Maintenance\u003c\/strong\u003e\u003cbr\u003eTypical diaphragm lifetimes are well in excess of 15,000 hours of use before replacement - that's years in most applications, minimizing downtime and service costs. When it is finally time for service, their unique design eliminates tedious, trial-and-error stroke length recalibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImproved Productivity\u003c\/strong\u003e\u003cbr\u003eVACUUBRAND\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003epumps are engineered for performance, with flow rates as much as 40% higher at working vacuum level than competitive pumps with similar free air capacity ratings. Higher flow rates mean reduced process times and higher throughput.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliability\u003c\/strong\u003e\u003cbr\u003eAll VACUUBRAND\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003epumps and systems must pass rigorous product testing before leaving the factory. It's your assurance of a reliable pump.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTechnical Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\u003cb\u003ePC 510 VARIO Select\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003eNumber of Heads\/Stages\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e2\/2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e2.0\/2.3\u003cspan data-mce-fragment=\"1\"\u003em3\/h\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e1.2\/1.4\u003cspan data-mce-fragment=\"1\"\u003ecfm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003eUltimate Vacuum (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e7\/5\u003cspan data-mce-fragment=\"1\"\u003embar\/torr\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\u003cspan\u003eUltimate Vacuum (abs.) with gas ballast\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e12\/9\u003cspan data-mce-fragment=\"1\"\u003embar\/torr\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003eAmbient Temperature Range (operation)\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e10 - 40\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003eAmbient Temperature Range (storage)\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e-10 - 60\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003eMax. Back Pressure (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e1.1\u003cspan data-mce-fragment=\"1\"\u003ebar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003eInlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eHose Nozzle DN 8-10mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003eOutlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan\u003eHose Nozzle DN 8-10mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003eCoolant Connection\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\u003cspan\u003e2 x Hose Nozzle DN 6-8mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003eRated Motor Power\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e0.18\u003cspan data-mce-fragment=\"1\"\u003ekW\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003eRated Motor Speed at 50\/60 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e1500\/1800\u003cspan data-mce-fragment=\"1\"\u003emin-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003eProtection Class\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eIP 40\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e418 x 243 x 457\u003cspan data-mce-fragment=\"1\"\u003emm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e17.2\u003cspan data-mce-fragment=\"1\"\u003ekg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003eNoise Level at 50 Hz, typ.\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e45\u003cspan data-mce-fragment=\"1\"\u003edBA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003eItems Supplied\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003ePumping unit completely mounted, ready for use, with manual.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"BrandTech Scientific","offers":[{"title":"Default Title","offer_id":43745853341955,"sku":"20733153","price":16451.84,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale)","offer_id":43745853374723,"sku":"20733153","price":13161.47,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/Screenshot2023-02-16094542.png?v=1676558756"},{"product_id":"vacuubrand-pc-511-vario-vacuu-select-dual-chemistry-vacuum-pump","title":"VACUUBRAND PC 511 VARIO VACUU·SELECT Dual Chemistry Vacuum Pump","description":"\u003cp data-mce-fragment=\"1\" style=\"text-align: center;\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eBrandTech™ VACUUBRAND™ PC 511 VARIO Select Dual Control Chemistry Pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\" style=\"text-align: left;\"\u003e\u003cspan\u003eVACUUBRAND™ PC 511 VARIO Select Dual Control Chemistry Pumps utilize VACUUBRAND\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e Oil-free Chemistry Design Vacuum Pumps to increase lab efficiency and reduce the cost of vacuum generation. Operating two different applications from a single pump saves money and lab bench space. These vacuum systems are available with both manual control and electronic control. Integrated check valves minimize interaction between applications.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003ePumps with electronic control are now available with an integrated VACUU·SELECT\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e controller! Easy-to-use, the VACUU·SELECT\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e controller provides a touch screen, application-based interface. Creating a new application is as easy as swiping a finger to drag-and-drop application building blocks.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\" style=\"text-align: left;\"\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual Control\u003c\/strong\u003e\u003cbr\u003eA PTFE diaphragm valve provides approximate control of vacuum levels for less demanding applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronic Control\u003c\/strong\u003e\u003cbr\u003eA solenoid valve, operated by the new VACUU·SELECT controller, provides precise two-point electronic control for important applications, maintaining vacuum levels between pre-set tolerances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVACUU·SELECT\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003econtroller\u003c\/strong\u003e\u003cbr\u003eController has a touch screen interface and predefined applications. It is easy-to-use and the modification of existing applications, or creation of new applications, is simple with drag-and-drop editing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Oil Changes\u003c\/strong\u003e\u003cbr\u003eThese vacuum pumps utilize diaphragm vacuum technology. The totally dry operation eliminates the misting, handling and disposal of contaminated waste associated with rotary vane pumps. No oil to change or monitor!\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduced Maintenance\u003c\/strong\u003e\u003cbr\u003eTypical diaphragm lifetimes are well in excess of 15,000 hours of use before replacement - that's years in most applications, minimizing downtime and service costs. When it is finally time for service, their unique design eliminates tedious, trial-and-error stroke length recalibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImproved Productivity\u003c\/strong\u003e\u003cbr\u003eVACUUBRAND\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003epumps are engineered for performance, with flow rates as much as 40% higher at working vacuum level than competitive pumps with similar free air capacity ratings. Higher flow rates mean reduced process times and higher throughput.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliability\u003c\/strong\u003e\u003cbr\u003eAll VACUUBRAND\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003epumps and systems must pass rigorous product testing before leaving the factory. It's your assurance of a reliable pump.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003ctable data-mce-fragment=\"1\" width=\"100%\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 52.5427%;\"\u003e \u003cstrong data-mce-fragment=\"1\"\u003eTechnical Data\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 56.4573%;\"\u003e\u003cb\u003ePC 511 Select\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 52.5427%;\"\u003eNumber of Heads\/Stages\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 56.4573%;\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e2\/2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 52.5427%;\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 56.4573%;\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e2.0\/2.3\u003cspan data-mce-fragment=\"1\"\u003em3\/h\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 52.5427%;\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 56.4573%;\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e1.2\/1.4\u003cspan data-mce-fragment=\"1\"\u003ecfm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 52.5427%;\"\u003eUltimate Vacuum (abs.)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 56.4573%;\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e7\/5\u003cspan data-mce-fragment=\"1\"\u003embar\/torr\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 52.5427%;\"\u003e\u003cspan\u003eUltimate Vacuum (abs.) with gas ballast\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 56.4573%;\"\u003e12\/9\u003cspan data-mce-fragment=\"1\"\u003embar\/torr\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 52.5427%;\"\u003eAmbient Temperature Range (operation)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 56.4573%;\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e10 - 40\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 52.5427%;\"\u003eAmbient Temperature Range (storage)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 56.4573%;\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e-10 - 60\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 52.5427%;\"\u003eMax. Back Pressure (abs.)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 56.4573%;\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e1.1\u003cspan data-mce-fragment=\"1\"\u003ebar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 52.5427%;\"\u003eInlet Connection\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 56.4573%;\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e2 x Hose Nozzle DN 8-10mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 52.5427%;\"\u003eOutlet Connection\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 56.4573%;\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan\u003eHose Nozzle DN 8-10mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 52.5427%;\"\u003eCoolant Connection\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 56.4573%;\"\u003e\u003cspan\u003e2 x Hose Nozzle DN 6-8mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 52.5427%;\"\u003eRated Motor Power\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 56.4573%;\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e0.18\u003cspan data-mce-fragment=\"1\"\u003ekW\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 52.5427%;\"\u003eRated Motor Speed at 50\/60 Hz\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 56.4573%;\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e1500\/1800\u003cspan data-mce-fragment=\"1\"\u003emin-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 52.5427%;\"\u003eProtection Class\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 56.4573%;\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eIP 40\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 52.5427%;\"\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 56.4573%;\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e435 x 243 x 457\u003cspan data-mce-fragment=\"1\"\u003emm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 52.5427%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 56.4573%;\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e17.4\u003cspan data-mce-fragment=\"1\"\u003ekg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 52.5427%;\"\u003eNoise Level at 50 Hz, typ.\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 56.4573%;\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e45\u003cspan data-mce-fragment=\"1\"\u003edBA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BrandTech Scientific","offers":[{"title":"Default Title","offer_id":43746212380931,"sku":"20733253","price":17909.77,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale)","offer_id":43746212413699,"sku":"20733253","price":14327.81,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/Screenshot2023-02-16125348.png?v=1676570044"},{"product_id":"vacuubrand-pc-201-nt-oil-free-chemistry-vacuum-pump-manual","title":"VACUUBRAND PC 201 NT Oil-Free Chemistry Vacuum Pump Manual","description":"\u003cp style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eBrandTech™ VACUUBRAND™ PC 201 NT Manual Control Vacuum Pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\" data-mce-fragment=\"1\"\u003eBrandTech™ VACUUBRAND™ PC 201 NT Manual Control Vacuum Pumps provide the most basic management of vacuum where electronic control is unnecessary to achieve good results. Centrifugal concentration, gel drying, and even simple rotary evaporation applications can often be effectively managed with manual control systems. Excellent corrosion resistance with manual control in a single system.\u003c\/p\u003e\n\u003cp style=\"text-align: left;\" data-mce-fragment=\"1\"\u003e\u003cspan\u003eThe new NT-series of pumps provide whisper-quiet and ultra-low-vibration operation, high leak-tightness and improved vacuum. The highly flexible, fabric-reinforced double diaphragm made of FKM offers extended operation life.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual Control Valve\u003c\/strong\u003e\u003cbr\u003eA PTFE diaphragm valve provides approximate control of vacuum levels for less demanding applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Oil Changes\u003c\/strong\u003e\u003cbr\u003eThese vacuum pumps utilize diaphragm vacuum technology. The totally dry operation eliminates the misting, handling and disposal of contaminated waste associated with rotary vane pumps. No oil to change or monitor!\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduced Maintenance\u003c\/strong\u003e\u003cbr\u003eTypical diaphragm lifetimes are well in excess of 15,000 hours of use before replacement - that's years in most applications, minimizing downtime and service costs. When it is finally time for service, their unique design eliminates tedious, trial-and-error stroke length recalibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImproved Productivity\u003c\/strong\u003e\u003cbr\u003eVACUUBRAND\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003epumps are engineered for performance, with flow rates as much as 40% higher at working vacuum level than competitive pumps with similar free air capacity ratings. Higher flow rates mean reduced process times and higher throughput.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliability\u003c\/strong\u003e\u003cbr\u003eAll VACUUBRAND\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003epumps and systems must pass rigorous product testing before leaving the factory. It's your assurance of a reliable pump.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\" data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003ctable width=\"100%\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 53.0285%;\" data-mce-fragment=\"1\"\u003e \u003cstrong data-mce-fragment=\"1\"\u003eTechnical Data\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.9715%;\" data-mce-fragment=\"1\"\u003e\u003cb\u003ePC 201 NT\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 53.0285%;\" data-mce-fragment=\"1\"\u003eVacuum Controller\u003c\/td\u003e\n\u003ctd style=\"width: 54.9715%;\" data-mce-fragment=\"1\"\u003eManometer\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 53.0285%;\" data-mce-fragment=\"1\"\u003eNumber of Heads\/Stages\u003c\/td\u003e\n\u003ctd style=\"width: 54.9715%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e4\/3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 53.0285%;\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.9715%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e3.4\/3.8\u003cspan data-mce-fragment=\"1\"\u003em3\/h\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 53.0285%;\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.9715%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e2.0\/2.2\u003cspan data-mce-fragment=\"1\"\u003ecfm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 53.0285%;\" data-mce-fragment=\"1\"\u003eUltimate Vacuum (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 54.9715%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e1.5\/1.1\u003cspan data-mce-fragment=\"1\"\u003embar\/torr\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 53.0285%;\" data-mce-fragment=\"1\"\u003e\u003cspan\u003eUltimate Vacuum (abs.) with gas ballast\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.9715%;\" data-mce-fragment=\"1\"\u003e3\/2.2\u003cspan data-mce-fragment=\"1\"\u003embar\/torr\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 53.0285%;\" data-mce-fragment=\"1\"\u003eAmbient Temperature Range (operation)\u003c\/td\u003e\n\u003ctd style=\"width: 54.9715%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e10 - 40\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 53.0285%;\" data-mce-fragment=\"1\"\u003eAmbient Temperature Range (storage)\u003c\/td\u003e\n\u003ctd style=\"width: 54.9715%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e-10 - 60\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 53.0285%;\" data-mce-fragment=\"1\"\u003eMax. Back Pressure (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 54.9715%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e1.1\u003cspan data-mce-fragment=\"1\"\u003ebar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 53.0285%;\" data-mce-fragment=\"1\"\u003eInlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 54.9715%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eHose Nozzle DN 8-10mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 53.0285%;\" data-mce-fragment=\"1\"\u003eOutlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 54.9715%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan\u003eHose Nozzle DN 8-10mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 53.0285%;\" data-mce-fragment=\"1\"\u003eCoolant Connection\u003c\/td\u003e\n\u003ctd style=\"width: 54.9715%;\" data-mce-fragment=\"1\"\u003e\u003cspan\u003e2 x Hose Nozzle DN 6-8mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 53.0285%;\" data-mce-fragment=\"1\"\u003eRated Motor Power\u003c\/td\u003e\n\u003ctd style=\"width: 54.9715%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e0.25\u003cspan data-mce-fragment=\"1\"\u003ekW\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 53.0285%;\" data-mce-fragment=\"1\"\u003eRated Motor Speed at 50\/60 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 54.9715%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e1500\/1800\u003cspan data-mce-fragment=\"1\"\u003emin-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 53.0285%;\" data-mce-fragment=\"1\"\u003eProtection Class\u003c\/td\u003e\n\u003ctd style=\"width: 54.9715%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eIP 40\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 53.0285%;\" data-mce-fragment=\"1\"\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd style=\"width: 54.9715%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e326 x 243 x 402\u003cspan data-mce-fragment=\"1\"\u003emm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 53.0285%;\" data-mce-fragment=\"1\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 54.9715%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e17.5\u003cspan data-mce-fragment=\"1\"\u003ekg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 53.0285%;\" data-mce-fragment=\"1\"\u003eNoise Level at 50 Hz, typ.\u003c\/td\u003e\n\u003ctd style=\"width: 54.9715%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e45\u003cspan data-mce-fragment=\"1\"\u003edBA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 53.0285%;\" data-mce-fragment=\"1\"\u003eNRTL Certification\u003c\/td\u003e\n\u003ctd style=\"width: 54.9715%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eCanada and the USA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"BrandTech Scientific","offers":[{"title":"Default Title","offer_id":43817767338243,"sku":"20737003","price":16309.95,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale)","offer_id":43817767371011,"sku":"20737003","price":13047.96,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/Screenshot2023-03-17100451.png?v=1679061906"},{"product_id":"vacuubrand-pc-3001-vario-vacuu-select-chemistry-vacuum-pump","title":"VACUUBRAND PC 3001 VARIO VACUU·SELECT Chemistry Vacuum Pump","description":"\u003cp style=\"text-align: center;\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eBrandTech™ VACUUBRAND™ PC 3001 VARIO Select Oil-Free Chemistry Pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eVACUUBRAND™ PC 3001 VARIO Select Oil-Free Chemistry Pump is the best choice vacuum system for bench-top sized rotary evaporators and other evaporative applications. The integrated VACUU•SELECT\u003c\/span\u003e\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e touch screen controller gives you fingertip control to select an automatic routine for your desired application. For example, for a rotary evaporator, the PC 3001 VARIO\u003c\/span\u003e\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e select automatically controls the vacuum, with minimal supervision, continuously optimizing to changing vapor conditions without programming. Just press “start” and the PC 3001 VARIO\u003c\/span\u003e\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e select provides faster evaporation and tighter control, while freeing you up to do more important work. You can even set up your own custom routine by modifying existing routines, or assembling your own with drag-and-drop building blocks. It features a VARIO\u003c\/span\u003e\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e version of our MD1C vacuum pump, with integrated solvent recovery in a compact, attractive package.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cspan data-mce-fragment=\"1\"\u003eVACUUBRAND's advanced VARIO control offers unparalleled precision and process automation capabilities that maximize yields, minimize process time, and liberate scientists and engineers to focus their attention on other tasks.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVACUU·SELECT\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003econtroller\u003c\/strong\u003e\u003cbr\u003eController has a touch screen interface and predefined applications. It is easy-to-use and the modification of existing applications, or creation of new applications, is simple with drag-and-drop editing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImproved Productivity\u003c\/strong\u003e\u003cbr\u003eThe self-adjusting VARIO\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003esystems require minimal oversight, freeing up time for other work. Plus, their continually optimized vacuum levels speed evaporation by up to 30%!\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Oil Changes\u003c\/strong\u003e\u003cbr\u003eThese vacuum pumps utilize diaphragm vacuum technology. The totally dry operation eliminates the misting, handling and disposal of contaminated waste associated with rotary vane pumps. No oil to change or monitor!\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduced Maintenance\u003c\/strong\u003e\u003cbr\u003eTypical diaphragm lifetimes are well in excess of 15,000 hours of use before replacement - that's years in most applications, minimizing downtime and service costs. When it is finally time for service, their unique design eliminates tedious, trial-and-error stroke length recalibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliability\u003c\/strong\u003e\u003cbr\u003eAll VACUUBRAND\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003epumps and systems must pass rigorous product testing before leaving the factory. It's your assurance of a reliable pump.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVirtually eliminates bumping and foaming, \u003c\/strong\u003eeven with complex processes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduce process time\u003c\/strong\u003e by as much as 30% compared to conventional electronic control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimizes power consumption\u003c\/strong\u003e and maintenance by continuously adjusting motor speed to process demands\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvailable in a wide range of configurations\u003c\/strong\u003e - standard-duty pumps, chemistry-rated pumps, chemistry-rated pumping systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePC 3001 Vario is the best selling, self-regulating vacuum pump system. \u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003cstrong\u003eTechnical Data\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ePC 3001 VARIO\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Controller\u003c\/td\u003e\n\u003ctd\u003eVACUU SELECT\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Heads\/Stages\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\/3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2.0\u003cspan data-mce-fragment=\"1\"\u003em3\/h\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1.2\u003cspan data-mce-fragment=\"1\"\u003ecfm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltimate Vacuum (abs.)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2.0\/1.5\u003cspan data-mce-fragment=\"1\"\u003embar\/torr\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUltimate Vacuum (abs.) with gas ballast\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\/3\u003cspan data-mce-fragment=\"1\"\u003embar\/torr\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature Range (operation)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10 - 40\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature Range (storage)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-10 - 60\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Back Pressure (abs.)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1.1\u003cspan data-mce-fragment=\"1\"\u003ebar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInlet Connection\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eHose Nozzle DN 6-10mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Connection\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eHose Nozzle DN 8-10mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoolant Connection\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e2 x Hose Nozzle DN 6-8mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Motor Power\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.16\u003cspan data-mce-fragment=\"1\"\u003ekW\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Speed Range\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e200-3000\u003cspan data-mce-fragment=\"1\"\u003emin-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIP 20\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e303 x 306 x 400mm\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8.2kg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Level at 50 Hz, typ.\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e42dBA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Literature:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"PC 3001 Vario Flyer\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/PC3001_Select_fly_BT.pdf?v=1680182990\" target=\"_blank\"\u003ePC 3001 Vario Flyer\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVideo:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ciframe title=\"Evaporation Using VACUUBRAND's Advanced VARIO® Control Technology\" src=\"https:\/\/www.youtube.com\/embed\/rIhOlL1kEUY\" height=\"315\" width=\"560\" allowfullscreen=\"\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" frameborder=\"0\"\u003e\u003c\/iframe\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"BrandTech Scientific","offers":[{"title":"Default Title","offer_id":43846201934083,"sku":"20700203","price":16049.84,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale)","offer_id":43846201966851,"sku":"20700203","price":12839.87,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/Screenshot2023-03-30095157.png?v=1680184332"},{"product_id":"vacuubrand-mz-2c-vario-vacuu-select-chemistry-vacuum-pump","title":"VACUUBRAND MZ 2C VARIO VACUU·SELECT Chemistry Vacuum Pump","description":"\u003cp style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eBrandTech™ VACUUBRAND™ MZ 2C VARIO Select Chemistry Diaphragm Pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eVACUUBRAND™ MZ 2C VARIO Select Chemistry Diaphragm Pumps offers users unsurpassed control of critical vacuum applications. A low maintenance oil-free chemistry-design pump is integrated with a variable speed motor and a mercury-free, digital controller. The system automatically finds and follows boiling curves, continuously optimizing the vacuum level without having to program presets. It's the ultimate productivity tool!\u003cbr\u003e\u003cbr\u003eEasy-to-use, the VACUU·SELECT\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003econtroller provides a touch screen, application-based interface. Creating a new application is as easy as swiping a finger to drag-and-drop application building blocks.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVACUU·SELECT\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003econtroller\u003c\/strong\u003e\u003cbr\u003eController has a touch screen interface and predefined applications. It is easy-to-use and the modification of existing applications, or creation of new applications, is simple with drag-and-drop editing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImproved Productivity\u003c\/strong\u003e\u003cbr\u003eThe self-adjusting VARIO\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003esystems require minimal oversight, freeing up time for other work. Plus, their continually optimized vacuum levels speed evaporation by up to 30%!\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Oil Changes\u003c\/strong\u003e\u003cbr\u003eThese vacuum pumps utilize diaphragm vacuum technology. The totally dry operation eliminates the misting, handling and disposal of contaminated waste associated with rotary vane pumps. No oil to change or monitor!\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduced Maintenance\u003c\/strong\u003e\u003cbr\u003eTypical diaphragm lifetimes are well in excess of 15,000 hours of use before replacement - that's years in most applications, minimizing downtime and service costs. When it is finally time for service, their unique design eliminates tedious, trial-and-error stroke length recalibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliability\u003c\/strong\u003e\u003cbr\u003eAll VACUUBRAND\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003epumps and systems must pass rigorous product testing before leaving the factory. It's your assurance of a reliable pump.\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003e \u003cstrong\u003eTechnical Data\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\u003cb\u003eMZ 2C VARIO Select\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eVacuum Controller\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003eVacuu-Select\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eNumber of Heads\/Stages\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e2\/2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e2.8\u003cspan data-mce-fragment=\"1\"\u003em3\/h\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e1.6\u003cspan data-mce-fragment=\"1\"\u003ecfm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eUltimate Vacuum (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e7\/5\u003cspan data-mce-fragment=\"1\"\u003embar\/torr\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eUltimate Vacuum (abs.) with Gas Ballast\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e12\/9\u003cspan data-mce-fragment=\"1\"\u003embar\/torr\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eAmbient Temperature Range (operation)\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e10 - 40\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eAmbient Temperature Range (storage)\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e-10 - 60\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eMax. Back Pressure (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e1.1\u003cspan data-mce-fragment=\"1\"\u003ebar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eInlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003eHose Nozzle DN 8-10mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eOutlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e\u003cspan\u003eHose Nozzle DN 8-10mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eRated Motor Power\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e0.53\u003cspan data-mce-fragment=\"1\"\u003ekW\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eRated Motor Speed at 50\/60 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e30-2400\u003cspan data-mce-fragment=\"1\"\u003emin-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eProtection Class\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003eIP 20\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e243 x 243 x 245\u003cspan data-mce-fragment=\"1\"\u003emm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e14.3\u003cspan data-mce-fragment=\"1\"\u003ekg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eNoise Level at 50 Hz, typ.\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e43\u003cspan data-mce-fragment=\"1\"\u003edBA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eATEX Conformity (only 230V)\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003eII 3\/-G Ex h IIC T3 X Internal Atm. only\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eItems Supplied\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003ePumping unit completely mounted, ready for use, with manual\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVideo:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/rIhOlL1kEUY\" title=\"Evaporation Using VACUUBRAND's Advanced VARIO® Control Technology\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"BrandTech Scientific","offers":[{"title":"Default Title","offer_id":43847909179651,"sku":"20732453","price":15481.02,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale)","offer_id":43847909212419,"sku":"20732453","price":12384.81,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/Screenshot2023-03-31090307.png?v=1680268167"},{"product_id":"vacuubrand-pc-610-vario-vacuu-select-chemistry-vacuum-pump","title":"VACUUBRAND PC 610 VARIO VACUU·SELECT Chemistry Vacuum Pump","description":"\u003cp data-mce-fragment=\"1\" style=\"text-align: center;\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eBrandTech™ VACUUBRAND™ PC 610 VARIO Select Electronic Control Chemistry Pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\" style=\"text-align: left;\"\u003eVACUUBRAND™ PC 610 VARIO Select Electronic Control Chemistry Pump is an \u003cspan data-mce-fragment=\"1\"\u003eexcellent choice for supporting controlled evaporation or drying processes. The PC 610 select can be used for many common solvents.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\" style=\"text-align: left;\"\u003e\u003cspan\u003eEasy-to-use, the VACUU·SELECT\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e controller provides a touch screen, application-based interface. Creating a new application is as easy as swiping a finger to drag-and-drop application building blocks. These pumps are excellent choices for supporting controlled evaporation or drying processes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\" style=\"text-align: left;\"\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eVACUU·SELECT\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003econtroller\u003c\/strong\u003e\u003cbr\u003eController has a touch screen interface and predefined applications. It is easy-to-use and the modification of existing applications, or creation of new applications, is simple with drag-and-drop editing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronic Control\u003c\/strong\u003e\u003cbr\u003eA solenoid valve, operated by the new VACUU·SELECT controller, provides precise two-point electronic control for important applications, maintaining vacuum levels between pre-set tolerances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Oil Changes\u003c\/strong\u003e\u003cbr\u003eThese vacuum pumps utilize diaphragm vacuum technology. The totally dry operation eliminates the misting, handling and disposal of contaminated waste associated with rotary vane pumps. No oil to change or monitor!\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduced Maintenance\u003c\/strong\u003e\u003cbr\u003eTypical diaphragm lifetimes are well in excess of 15,000 hours of use before replacement - that's years in most applications, minimizing downtime and service costs. When it is finally time for service, their unique design eliminates tedious, trial-and-error stroke length recalibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImproved Productivity\u003c\/strong\u003e\u003cbr\u003eVACUUBRAND\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003epumps are engineered for performance, with flow rates as much as 40% higher at working vacuum level than competitive pumps with similar free air capacity ratings. Higher flow rates mean reduced process times and higher throughput.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliability\u003c\/strong\u003e\u003cbr\u003eAll VACUUBRAND\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003epumps and systems must pass rigorous product testing before leaving the factory. It's your assurance of a reliable pump.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\" width=\"100%\" data-mce-selected=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 54.7209%;\" data-mce-selected=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTechnical Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 54.2791%;\" data-mce-selected=\"1\"\u003e\u003cb\u003ePC 610 VARIO Select\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 54.7209%;\" data-mce-selected=\"1\"\u003eVacuum Controller\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 54.2791%;\" data-mce-selected=\"1\"\u003eVacuu-Select\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 54.7209%;\" data-mce-selected=\"1\"\u003eNumber of Heads\/Stages\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 54.2791%;\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e4\/3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 54.7209%;\" data-mce-selected=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 54.2791%;\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e3.4\/3.8m3\/h\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 54.7209%;\" data-mce-selected=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 54.2791%;\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e2.0\/2.2cfm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 54.7209%;\" data-mce-selected=\"1\"\u003eUltimate Vacuum (abs.)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 54.2791%;\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e1.5\/1.1mbar\/torr\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 54.7209%;\" data-mce-selected=\"1\"\u003e\u003cspan\u003eUltimate Vacuum (abs.) with gas ballast\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 54.2791%;\" data-mce-selected=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e3\/2.2mbar\/torr\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 54.7209%;\" data-mce-selected=\"1\"\u003eAmbient Temperature Range (operation)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 54.2791%;\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e10 - 40\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 54.7209%;\" data-mce-selected=\"1\"\u003eAmbient Temperature Range (storage)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 54.2791%;\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e-10 - 60\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 54.7209%;\" data-mce-selected=\"1\"\u003eMax. Back Pressure (abs.)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 54.2791%;\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e1.1\u003cspan data-mce-fragment=\"1\"\u003ebar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 54.7209%;\" data-mce-selected=\"1\"\u003eInlet Connection\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 54.2791%;\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eHose Nozzle DN 8-10mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 54.7209%;\" data-mce-selected=\"1\"\u003eOutlet Connection\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 54.2791%;\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan\u003eHose Nozzle DN 8-10mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 54.7209%;\" data-mce-selected=\"1\"\u003eCoolant Connection\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 54.2791%;\" data-mce-selected=\"1\"\u003e\u003cspan\u003e2 x Hose Nozzle DN 6-8mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 54.7209%;\" data-mce-selected=\"1\"\u003eRated Motor Power\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 54.2791%;\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e0.25\u003cspan data-mce-fragment=\"1\"\u003ekW\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 54.7209%;\" data-mce-selected=\"1\"\u003eRated Motor Speed at 50\/60 Hz\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 54.2791%;\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e1500\/1800\u003cspan data-mce-fragment=\"1\"\u003emin-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 54.7209%;\" data-mce-selected=\"1\"\u003eProtection Class\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 54.2791%;\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eIP 40\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 54.7209%;\" data-mce-selected=\"1\"\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 54.2791%;\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e419 x 243 x 457\u003cspan data-mce-fragment=\"1\"\u003emm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 54.7209%;\" data-mce-selected=\"1\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 54.2791%;\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e20.4kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 54.7209%;\" data-mce-selected=\"1\"\u003eNoise Level at 50 Hz, typ.\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 54.2791%;\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e45\u003cspan data-mce-fragment=\"1\"\u003edBA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"BrandTech Scientific","offers":[{"title":"Default Title","offer_id":43847946404099,"sku":"20737153","price":25567.58,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale)","offer_id":43847946436867,"sku":"20737153","price":20454.06,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/Screenshot2023-03-31095329.png?v=1680270821"},{"product_id":"vacuubrand-pc-611-vario-vacuu-select-dual-chemistry-vacuum-pump","title":"VACUUBRAND PC 611 VARIO VACUU·SELECT Dual Chemistry Vacuum Pump","description":"\u003cp style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eBrandTech™ VACUUBRAND™ PC 611 VARIO Select Dual Control Chemistry Pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eVACUUBRAND™ PC 611 VARIO Select Dual Control Chemistry Pump utilizes VACUUBRAND\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eOil-free Chemistry Design Vacuum Pumps to increase lab efficiency and reduce the cost of vacuum generation. Operating two different applications from a single pump saves money and lab bench space. This vacuum system is available with both a manual and electronic control. Integrated check valves minimize interaction between applications.\u003cbr\u003e\u003cbr\u003ePumps with electronic control are now available with an integrated VACUU·SELECT\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003econtroller! Easy-to-use, the VACUU·SELECT\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003econtroller provides a touch screen, application-based interface. Creating a new application is as easy as swiping a finger to drag-and-drop application building blocks.\u003cbr\u003e\u003cbr\u003eThese pumps are excellent choices for supporting controlled evaporation or drying processes. The PC 511\/520 select, with the MZ 2C NT two stage chemistry diaphragm pump (7 mbar\/1.4 cfm) can be used for many common solvents, while the PC 611\/620 select, with the MD 4C NT three stage chemistry diaphragm pump (1.5 mbar\/2.2 cfm) meets the higher vacuum requirements for most high boiling point solvents.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual Control\u003c\/strong\u003e\u003cbr\u003eA PTFE diaphragm valve provides approximate control of vacuum levels for less demanding applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronic Control\u003c\/strong\u003e\u003cbr\u003eA solenoid valve, operated by the new VACUU·SELECT controller, provides precise two-point electronic control for important applications, maintaining vacuum levels between pre-set tolerances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVACUU·SELECT\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003econtroller\u003c\/strong\u003e\u003cbr\u003eController has a touch screen interface and predefined applications. It is easy-to-use and the modification of existing applications, or creation of new applications, is simple with drag-and-drop editing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Oil Changes\u003c\/strong\u003e\u003cbr\u003eThese vacuum pumps utilize diaphragm vacuum technology. The totally dry operation eliminates the misting, handling and disposal of contaminated waste associated with rotary vane pumps. No oil to change or monitor!\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduced Maintenance\u003c\/strong\u003e\u003cbr\u003eTypical diaphragm lifetimes are well in excess of 15,000 hours of use before replacement - that's years in most applications, minimizing downtime and service costs. When it is finally time for service, their unique design eliminates tedious, trial-and-error stroke length recalibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImproved Productivity\u003c\/strong\u003e\u003cbr\u003eVACUUBRAND\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003epumps are engineered for performance, with flow rates as much as 40% higher at working vacuum level than competitive pumps with similar free air capacity ratings. Higher flow rates mean reduced process times and higher throughput.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliability\u003c\/strong\u003e\u003cbr\u003eAll VACUUBRAND\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003epumps and systems must pass rigorous product testing before leaving the factory. It's your assurance of a reliable pump.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTechnical Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\u003cb\u003ePC 611 VARIO Select\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003eVacuum Controller\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003eVacuu-Select\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003eNumber of Heads\/Stages\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e4\/3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e3.4\/3.8m3\/h\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e2.0\/2.2cfm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003eUltimate Vacuum (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e1.5\/1.1mbar\/torr\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\u003cspan\u003eUltimate Vacuum (abs.) with gas ballast\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e3\/2.2mbar\/torr\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003eAmbient Temperature Range (operation)\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e10 - 40\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003eAmbient Temperature Range (storage)\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e-10 - 60\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003eMax. Back Pressure (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e1.1\u003cspan data-mce-fragment=\"1\"\u003ebar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003eInlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e2 x Hose Nozzle DN 8-10mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003eOutlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan\u003eHose Nozzle DN 8-10mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003eCoolant Connection\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\u003cspan\u003e2 x Hose Nozzle DN 6-8mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003eRated Motor Power\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e0.25\u003cspan data-mce-fragment=\"1\"\u003ekW\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003eRated Motor Speed at 50\/60 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e1500\/1800\u003cspan data-mce-fragment=\"1\"\u003emin-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003eProtection Class\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eIP 40\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e435 x 243 x 457\u003cspan data-mce-fragment=\"1\"\u003emm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e20.6kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003eNoise Level at 50 Hz, typ.\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-fragment=\"1\" data-mce-selected=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e45\u003cspan data-mce-fragment=\"1\"\u003edBA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVideo:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/rIhOlL1kEUY\" title=\"Evaporation Using VACUUBRAND's Advanced VARIO® Control Technology\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"BrandTech Scientific","offers":[{"title":"Default Title","offer_id":43847980876035,"sku":"20737253","price":26723.61,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale)","offer_id":43847980908803,"sku":"20737253","price":21378.89,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/Screenshot2023-03-31095329_a4ddf9bf-78a5-4d11-8cc4-294b6dae41c4.png?v=1680271972"},{"product_id":"vacuubrand-pc-620-vario-vacuu-select-dual-chemistry-vacuum-pump","title":"VACUUBRAND PC 620 VARIO VACUU·SELECT Dual Chemistry Vacuum Pump","description":"\u003cp style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eBrandTech™ VACUUBRAND™ PC 620 VARIO Select Dual Control Chemistry Pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eVACUUBRAND™ PC 620 VARIO Select Dual Control Chemistry Pump utilizes VACUUBRAND\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eOil-free Chemistry Design Vacuum Pumps to increase lab efficiency and reduce the cost of vacuum generation. Operating two different applications from a single pump saves money and lab bench space. This vacuum system is available with 2 electronic controls. \u003cspan data-mce-fragment=\"1\"\u003eIntegrated check valves minimize interaction between applications.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003ePumps with electronic control are now available with an integrated VACUU·SELECT\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003econtroller! Easy-to-use, the VACUU·SELECT\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003econtroller provides a touch screen, application-based interface. Creating a new application is as easy as swiping a finger to drag-and-drop application building blocks.\u003cbr\u003e\u003cbr\u003eThese pumps are excellent choices for supporting controlled evaporation or drying processes. The PC 511\/520 select, with the MZ 2C NT two stage chemistry diaphragm pump (7 mbar\/1.4 cfm) can be used for many common solvents, while the PC 611\/620 select, with the MD 4C NT three stage chemistry diaphragm pump (1.5 mbar\/2.2 cfm) meets the higher vacuum requirements for most high boiling point solvents.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronic Control\u003c\/strong\u003e\u003cbr\u003eA solenoid valve, operated by the new VACUU·SELECT controller, provides precise two-point electronic control for important applications, maintaining vacuum levels between pre-set tolerances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVACUU·SELECT\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003econtroller\u003c\/strong\u003e\u003cbr\u003eController has a touch screen interface and predefined applications. It is easy-to-use and the modification of existing applications, or creation of new applications, is simple with drag-and-drop editing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Oil Changes\u003c\/strong\u003e\u003cbr\u003eThese vacuum pumps utilize diaphragm vacuum technology. The totally dry operation eliminates the misting, handling and disposal of contaminated waste associated with rotary vane pumps. No oil to change or monitor!\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduced Maintenance\u003c\/strong\u003e\u003cbr\u003eTypical diaphragm lifetimes are well in excess of 15,000 hours of use before replacement - that's years in most applications, minimizing downtime and service costs. When it is finally time for service, their unique design eliminates tedious, trial-and-error stroke length recalibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImproved Productivity\u003c\/strong\u003e\u003cbr\u003eVACUUBRAND\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003epumps are engineered for performance, with flow rates as much as 40% higher at working vacuum level than competitive pumps with similar free air capacity ratings. Higher flow rates mean reduced process times and higher throughput.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliability\u003c\/strong\u003e\u003cbr\u003eAll VACUUBRAND\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003epumps and systems must pass rigorous product testing before leaving the factory. It's your assurance of a reliable pump.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\" data-mce-selected=\"1\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-selected=\"1\" data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTechnical Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-selected=\"1\" data-mce-fragment=\"1\"\u003e\u003cb\u003ePC 620 VARIO Select\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-selected=\"1\" data-mce-fragment=\"1\"\u003eVacuum Controller\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-selected=\"1\" data-mce-fragment=\"1\"\u003eVacuu-Select\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-selected=\"1\" data-mce-fragment=\"1\"\u003eNumber of Heads\/Stages\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-selected=\"1\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e4\/3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-selected=\"1\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-selected=\"1\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e3.4\/3.8m3\/h\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-selected=\"1\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-selected=\"1\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e2.0\/2.2cfm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-selected=\"1\" data-mce-fragment=\"1\"\u003eUltimate Vacuum (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-selected=\"1\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e1.5\/1.1mbar\/torr\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-selected=\"1\" data-mce-fragment=\"1\"\u003e\u003cspan\u003eUltimate Vacuum (abs.) with gas ballast\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-selected=\"1\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e3\/2.2mbar\/torr\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-selected=\"1\" data-mce-fragment=\"1\"\u003eAmbient Temperature Range (operation)\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-selected=\"1\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e10 - 40\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-selected=\"1\" data-mce-fragment=\"1\"\u003eAmbient Temperature Range (storage)\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-selected=\"1\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e-10 - 60\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-selected=\"1\" data-mce-fragment=\"1\"\u003eMax. Back Pressure (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-selected=\"1\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e1.1\u003cspan data-mce-fragment=\"1\"\u003ebar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-selected=\"1\" data-mce-fragment=\"1\"\u003eInlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-selected=\"1\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e2 x Hose Nozzle DN 8-10mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-selected=\"1\" data-mce-fragment=\"1\"\u003eOutlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-selected=\"1\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan\u003eHose Nozzle DN 8-10mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-selected=\"1\" data-mce-fragment=\"1\"\u003eCoolant Connection\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-selected=\"1\" data-mce-fragment=\"1\"\u003e\u003cspan\u003e2 x Hose Nozzle DN 6-8mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-selected=\"1\" data-mce-fragment=\"1\"\u003eRated Motor Power\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-selected=\"1\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e0.25\u003cspan data-mce-fragment=\"1\"\u003ekW\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-selected=\"1\" data-mce-fragment=\"1\"\u003eRated Motor Speed at 50\/60 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-selected=\"1\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e1500\/1800\u003cspan data-mce-fragment=\"1\"\u003emin-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-selected=\"1\" data-mce-fragment=\"1\"\u003eProtection Class\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-selected=\"1\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eIP 40\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-selected=\"1\" data-mce-fragment=\"1\"\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-selected=\"1\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e435 x 243 x 457\u003cspan data-mce-fragment=\"1\"\u003emm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-selected=\"1\" data-mce-fragment=\"1\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-selected=\"1\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e20.6kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 54.7209%;\" data-mce-selected=\"1\" data-mce-fragment=\"1\"\u003eNoise Level at 50 Hz, typ.\u003c\/td\u003e\n\u003ctd style=\"width: 54.2791%;\" data-mce-selected=\"1\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e45\u003cspan data-mce-fragment=\"1\"\u003edBA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVideo:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ciframe title=\"Evaporation Using VACUUBRAND's Advanced VARIO® Control Technology\" src=\"https:\/\/www.youtube.com\/embed\/rIhOlL1kEUY\" height=\"315\" width=\"560\" allowfullscreen=\"\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" frameborder=\"0\"\u003e\u003c\/iframe\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"BrandTech Scientific","offers":[{"title":"Default Title","offer_id":43848079409411,"sku":"20737353","price":32643.69,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale)","offer_id":43848079442179,"sku":"20737353","price":26114.95,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/Screenshot2023-03-31113802.png?v=1680277097"},{"product_id":"vacuubrand-pc-3004-vario-vacuu-select-chemistry-vacuum-pump","title":"VACUUBRAND PC 3004 VARIO VACUU·SELECT Chemistry Vacuum Pump","description":"\u003cp style=\"text-align: center;\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eBrandTech™ VACUUBRAND™ PC 3004 VARIO Select Oil-Free Chemistry Pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eVACUUBRAND™ PC 3004 VARIO Select Oil-Free Chemistry Pumps offer users unsurpassed control of critical vacuum applications. A low maintenance oil-free chemistry-design pump is integrated with a variable speed motor and a mercury-free, digital controller. The system automatically finds and follows boiling curves, continuously optimizing the vacuum level without having to program presets. It's the ultimate productivity tool!\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eEasy-to-use, the VACUU·SELECT\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e controller provides a touch screen, application-based interface. Creating a new application is as easy as swiping a finger to drag-and-drop application building blocks.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVACUU·SELECT\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003econtroller\u003c\/strong\u003e\u003cbr\u003eController has a touch screen interface and predefined applications. It is easy-to-use and the modification of existing applications, or creation of new applications, is simple with drag-and-drop editing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImproved Productivity\u003c\/strong\u003e\u003cbr\u003eThe self-adjusting VARIO\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003esystems require minimal oversight, freeing up time for other work. Plus, their continually optimized vacuum levels speed evaporation by up to 30%!\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Oil Changes\u003c\/strong\u003e\u003cbr\u003eThese vacuum pumps utilize diaphragm vacuum technology. The totally dry operation eliminates the misting, handling and disposal of contaminated waste associated with rotary vane pumps. No oil to change or monitor!\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduced Maintenance\u003c\/strong\u003e\u003cbr\u003eTypical diaphragm lifetimes are well in excess of 15,000 hours of use before replacement - that's years in most applications, minimizing downtime and service costs. When it is finally time for service, their unique design eliminates tedious, trial-and-error stroke length recalibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliability\u003c\/strong\u003e\u003cbr\u003eAll VACUUBRAND\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003epumps and systems must pass rigorous product testing before leaving the factory. It's your assurance of a reliable pump.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVirtually eliminates bumping and foaming, \u003c\/strong\u003eeven with complex processes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduce process time\u003c\/strong\u003e by as much as 30% compared to conventional electronic control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimizes power consumption\u003c\/strong\u003e and maintenance by continuously adjusting motor speed to process demands\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvailable in a wide range of configurations\u003c\/strong\u003e - standard-duty pumps, chemistry-rated pumps, chemistry-rated pumping systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003cstrong\u003eTechnical Data\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ePC 3004 VARIO\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Controller\u003c\/td\u003e\n\u003ctd\u003eVACUU SELECT\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Heads\/Stages\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\/3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e4.6m3\/h\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e2.7cfm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltimate Vacuum (abs.)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e1.5\/1.1mbar\/torr\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUltimate Vacuum (abs.) with gas ballast\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e3\/2.2mbar\/torr\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature Range (operation)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10 - 40\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature Range (storage)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-10 - 60\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Back Pressure (abs.)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1.1\u003cspan data-mce-fragment=\"1\"\u003ebar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInlet Connection\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eHose Nozzle DN 6-10mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Connection\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eHose Nozzle DN 8-10mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoolant Connection\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e2 x Hose Nozzle DN 6-8mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Motor Power\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.53\u003cspan data-mce-fragment=\"1\"\u003ekW\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Speed Range\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e30-2400min-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIP 40\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e419 x 243 x 457mm\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e21.1kg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Level at 50 Hz, typ.\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e43dBA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX Conformity (only 230V)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eII 3\/-G IIC T3 X Internal Atm. only\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eItems Supplied\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePumping unit completely mounted, ready for use, with manual\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Literature:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"PC 3001 Vario Flyer\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/PC3001_Select_fly_BT.pdf?v=1680182990\" target=\"_blank\"\u003ePC 3004 Vario Flyer\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVideo:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ciframe title=\"Evaporation Using VACUUBRAND's Advanced VARIO® Control Technology\" src=\"https:\/\/www.youtube.com\/embed\/rIhOlL1kEUY\" height=\"315\" width=\"560\" allowfullscreen=\"\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" frameborder=\"0\"\u003e\u003c\/iframe\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"BrandTech Scientific","offers":[{"title":"Default Title","offer_id":43848101495043,"sku":"20737553","price":21736.8,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale)","offer_id":43848101527811,"sku":"20737553","price":17389.44,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/Screenshot2023-03-31120912.png?v=1680278962"},{"product_id":"vacuubrand-pc-3003-vario-vacuu-select-chemistry-vacuum-pump","title":"VACUUBRAND PC 3003 VARIO VACUU·SELECT Chemistry Vacuum Pump","description":"\u003cp style=\"text-align: center;\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eBrandTech™ VACUUBRAND™ PC 3003 VARIO Select Oil-Free Chemistry Pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eVACUUBRAND™ PC 3003 VARIO Select Oil-Free Chemistry Pumps offer users unsurpassed control of critical vacuum applications. A low maintenance oil-free chemistry-design pump is integrated with a variable speed motor and a mercury-free, digital controller. The system automatically finds and follows boiling curves, continuously optimizing the vacuum level without having to program presets. It's the ultimate productivity tool!\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eEasy-to-use, the VACUU·SELECT\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e controller provides a touch screen, application-based interface. Creating a new application is as easy as swiping a finger to drag-and-drop application building blocks.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVACUU·SELECT\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003econtroller\u003c\/strong\u003e\u003cbr\u003eController has a touch screen interface and predefined applications. It is easy-to-use and the modification of existing applications, or creation of new applications, is simple with drag-and-drop editing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImproved Productivity\u003c\/strong\u003e\u003cbr\u003eThe self-adjusting VARIO\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003esystems require minimal oversight, freeing up time for other work. Plus, their continually optimized vacuum levels speed evaporation by up to 30%!\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Oil Changes\u003c\/strong\u003e\u003cbr\u003eThese vacuum pumps utilize diaphragm vacuum technology. The totally dry operation eliminates the misting, handling and disposal of contaminated waste associated with rotary vane pumps. No oil to change or monitor!\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduced Maintenance\u003c\/strong\u003e\u003cbr\u003eTypical diaphragm lifetimes are well in excess of 15,000 hours of use before replacement - that's years in most applications, minimizing downtime and service costs. When it is finally time for service, their unique design eliminates tedious, trial-and-error stroke length recalibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliability\u003c\/strong\u003e\u003cbr\u003eAll VACUUBRAND\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003epumps and systems must pass rigorous product testing before leaving the factory. It's your assurance of a reliable pump.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVirtually eliminates bumping and foaming, \u003c\/strong\u003eeven with complex processes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduce process time\u003c\/strong\u003e by as much as 30% compared to conventional electronic control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimizes power consumption\u003c\/strong\u003e and maintenance by continuously adjusting motor speed to process demands\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvailable in a wide range of configurations\u003c\/strong\u003e - standard-duty pumps, chemistry-rated pumps, chemistry-rated pumping systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003cstrong\u003eTechnical Data\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ePC 3003 VARIO\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Controller\u003c\/td\u003e\n\u003ctd\u003eVACUU SELECT\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Heads\/Stages\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\/4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e2.8m3\/h\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e1.6cfm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltimate Vacuum (abs.)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e0.6\/0.45mbar\/torr\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUltimate Vacuum (abs.) with gas ballast\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e1.5\/1.12mbar\/torr\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature Range (operation)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10 - 40\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature Range (storage)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-10 - 60\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Back Pressure (abs.)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1.1\u003cspan data-mce-fragment=\"1\"\u003ebar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInlet Connection\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eHose Nozzle DN 8-10mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Connection\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eHose Nozzle DN 8-10mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoolant Connection\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e2 x Hose Nozzle DN 6-8mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Motor Power\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.53\u003cspan data-mce-fragment=\"1\"\u003ekW\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Speed Range\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e30-2400min-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIP 40\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e419 x 243 x 457mm\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e21.1kg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Level at 50 Hz, typ.\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e43dBA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX Conformity (only 230V)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eII 3\/-G IIC T3 X Internal Atm. only\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eItems Supplied\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePumping unit completely mounted, ready for use, with manual\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Literature:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"PC 3001 Vario Flyer\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/PC3001_Select_fly_BT.pdf?v=1680182990\" target=\"_blank\"\u003ePC 3003 Vario Flyer\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVideo:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ciframe title=\"Evaporation Using VACUUBRAND's Advanced VARIO® Control Technology\" src=\"https:\/\/www.youtube.com\/embed\/rIhOlL1kEUY\" height=\"315\" width=\"560\" allowfullscreen=\"\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" frameborder=\"0\"\u003e\u003c\/iframe\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"BrandTech Scientific","offers":[{"title":"Default Title","offer_id":43853146390787,"sku":"20738453","price":24265.98,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale)","offer_id":43853146423555,"sku":"20738453","price":19412.78,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/Screenshot2023-03-31120912_6960c4ab-6c10-495f-8824-837ec90c3c58.png?v=1680550096"},{"product_id":"vacuubrand-pc-3002-vario-select-oil-free-chemistry-pump","title":"VACUUBRAND PC 3002 VARIO Select Oil-Free Chemistry Pump","description":"\u003cp style=\"text-align: center;\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eBrandTech™ VACUUBRAND™ PC 3002 VARIO Select Oil-Free Chemistry Pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eVACUUBRAND™ PC 3002 VARIO Select Oil-Free Chemistry Pumps offer users unsurpassed control of critical vacuum applications. A low maintenance oil-free chemistry-design pump is integrated with a variable speed motor and a mercury-free, digital controller. The system automatically finds and follows boiling curves, continuously optimizing the vacuum level without having to program presets. It's the ultimate productivity tool!\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eEasy-to-use, the VACUU·SELECT\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e controller provides a touch screen, application-based interface. Creating a new application is as easy as swiping a finger to drag-and-drop application building blocks.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVACUU·SELECT\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003econtroller\u003c\/strong\u003e\u003cbr\u003eController has a touch screen interface and predefined applications. It is easy-to-use and the modification of existing applications, or creation of new applications, is simple with drag-and-drop editing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImproved Productivity\u003c\/strong\u003e\u003cbr\u003eThe self-adjusting VARIO\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003esystems require minimal oversight, freeing up time for other work. Plus, their continually optimized vacuum levels speed evaporation by up to 30%!\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Oil Changes\u003c\/strong\u003e\u003cbr\u003eThese vacuum pumps utilize diaphragm vacuum technology. The totally dry operation eliminates the misting, handling and disposal of contaminated waste associated with rotary vane pumps. No oil to change or monitor!\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduced Maintenance\u003c\/strong\u003e\u003cbr\u003eTypical diaphragm lifetimes are well in excess of 15,000 hours of use before replacement - that's years in most applications, minimizing downtime and service costs. When it is finally time for service, their unique design eliminates tedious, trial-and-error stroke length recalibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliability\u003c\/strong\u003e\u003cbr\u003eAll VACUUBRAND\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003epumps and systems must pass rigorous product testing before leaving the factory. It's your assurance of a reliable pump.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVirtually eliminates bumping and foaming, \u003c\/strong\u003eeven with complex processes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduce process time\u003c\/strong\u003e by as much as 30% compared to conventional electronic control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimizes power consumption\u003c\/strong\u003e and maintenance by continuously adjusting motor speed to process demands\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvailable in a wide range of configurations\u003c\/strong\u003e - standard-duty pumps, chemistry-rated pumps, chemistry-rated pumping systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003cstrong\u003eTechnical Data\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ePC 3002 VARIO\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Controller\u003c\/td\u003e\n\u003ctd\u003eVACUU SELECT\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Heads\/Stages\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\/2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e2.8m3\/h\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e1.6cfm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltimate Vacuum (abs.)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e7\/5mbar\/torr\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUltimate Vacuum (abs.) with gas ballast\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e12\/9mbar\/torr\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature Range (operation)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10 - 40\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature Range (storage)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-10 - 60\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Back Pressure (abs.)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1.1\u003cspan data-mce-fragment=\"1\"\u003ebar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInlet Connection\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eHose Nozzle DN 8-10mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Connection\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eHose Nozzle DN 8-10mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoolant Connection\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e2 x Hose Nozzle DN 6-8mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Motor Power\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.53\u003cspan data-mce-fragment=\"1\"\u003ekW\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Speed Range\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e30-2400min-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIP 40\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e419 x 243 x 457mm\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e17.9kg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Level at 50 Hz, typ.\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e43dBA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX Conformity (only 230V)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eII 3\/-G IIC T3 X Internal Atm. only\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eItems Supplied\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePumping unit completely mounted, ready for use, with manual\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Literature:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"PC 3001 Vario Flyer\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/PC3001_Select_fly_BT.pdf?v=1680182990\" target=\"_blank\"\u003ePC 3002 Vario Flyer\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVideo:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ciframe title=\"Evaporation Using VACUUBRAND's Advanced VARIO® Control Technology\" src=\"https:\/\/www.youtube.com\/embed\/rIhOlL1kEUY\" height=\"315\" width=\"560\" allowfullscreen=\"\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" frameborder=\"0\"\u003e\u003c\/iframe\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"BrandTech Scientific","offers":[{"title":"Default Title","offer_id":43854555250947,"sku":"20733553","price":17078.28,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale)","offer_id":43854555283715,"sku":"20733553","price":13662.63,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/Screenshot2023-03-31120912_6d457be2-b59c-49ce-aac4-6728e1367cac.png?v=1680617469"},{"product_id":"vacuubrand-pc-520-vario-vacuu-select-dual-chemistry-vacuum-pump","title":"VACUUBRAND PC 520 VARIO VACUU·SELECT Dual Chemistry Vacuum Pump","description":"\u003cp style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eBrandTech™ VACUUBRAND™ PC 520 VARIO Select Dual Control Chemistry Pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\" data-mce-fragment=\"1\"\u003e\u003cspan\u003eVACUUBRAND™ PC 520 VARIO Select Dual Control Chemistry Pumps utilize VACUUBRAND\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e Oil-free Chemistry Design Vacuum Pumps to increase lab efficiency and reduce the cost of vacuum generation. Operating two different applications from a single pump saves money and lab bench space. This vacuum system is available with 2 electronic controls. Integrated check valves minimize interaction between applications.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eEasy-to-use, the VACUU·SELECT\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e controller provides a touch screen, application-based interface. Creating a new application is as easy as swiping a finger to drag-and-drop application building blocks.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronic Control\u003c\/strong\u003e\u003cbr\u003eA solenoid valve, operated by the new VACUU·SELECT controller, provides precise two-point electronic control for important applications, maintaining vacuum levels between pre-set tolerances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVACUU·SELECT\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003econtroller\u003c\/strong\u003e\u003cbr\u003eController has a touch screen interface and predefined applications. It is easy-to-use and the modification of existing applications, or creation of new applications, is simple with drag-and-drop editing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Oil Changes\u003c\/strong\u003e\u003cbr\u003eThese vacuum pumps utilize diaphragm vacuum technology. The totally dry operation eliminates the misting, handling and disposal of contaminated waste associated with rotary vane pumps. No oil to change or monitor!\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduced Maintenance\u003c\/strong\u003e\u003cbr\u003eTypical diaphragm lifetimes are well in excess of 15,000 hours of use before replacement - that's years in most applications, minimizing downtime and service costs. When it is finally time for service, their unique design eliminates tedious, trial-and-error stroke length recalibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImproved Productivity\u003c\/strong\u003e\u003cbr\u003eVACUUBRAND\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003epumps are engineered for performance, with flow rates as much as 40% higher at working vacuum level than competitive pumps with similar free air capacity ratings. Higher flow rates mean reduced process times and higher throughput.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliability\u003c\/strong\u003e\u003cbr\u003eAll VACUUBRAND\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003epumps and systems must pass rigorous product testing before leaving the factory. It's your assurance of a reliable pump.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003ctable width=\"100%\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 52.5427%;\" data-mce-fragment=\"1\"\u003e \u003cstrong data-mce-fragment=\"1\"\u003eTechnical Data\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 56.4573%;\" data-mce-fragment=\"1\"\u003e\u003cb\u003ePC 511 Select\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 52.5427%;\" data-mce-fragment=\"1\"\u003eNumber of Heads\/Stages\u003c\/td\u003e\n\u003ctd style=\"width: 56.4573%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e2\/2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 52.5427%;\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.4573%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e2.0\/2.3\u003cspan data-mce-fragment=\"1\"\u003em3\/h\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 52.5427%;\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.4573%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e1.2\/1.4\u003cspan data-mce-fragment=\"1\"\u003ecfm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 52.5427%;\" data-mce-fragment=\"1\"\u003eUltimate Vacuum (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 56.4573%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e7\/5\u003cspan data-mce-fragment=\"1\"\u003embar\/torr\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 52.5427%;\" data-mce-fragment=\"1\"\u003e\u003cspan\u003eUltimate Vacuum (abs.) with gas ballast\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.4573%;\" data-mce-fragment=\"1\"\u003e12\/9\u003cspan data-mce-fragment=\"1\"\u003embar\/torr\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 52.5427%;\" data-mce-fragment=\"1\"\u003eAmbient Temperature Range (operation)\u003c\/td\u003e\n\u003ctd style=\"width: 56.4573%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e10 - 40\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 52.5427%;\" data-mce-fragment=\"1\"\u003eAmbient Temperature Range (storage)\u003c\/td\u003e\n\u003ctd style=\"width: 56.4573%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e-10 - 60\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 52.5427%;\" data-mce-fragment=\"1\"\u003eMax. Back Pressure (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 56.4573%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e1.1\u003cspan data-mce-fragment=\"1\"\u003ebar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 52.5427%;\" data-mce-fragment=\"1\"\u003eInlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 56.4573%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e2 x Hose Nozzle DN 8-10mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 52.5427%;\" data-mce-fragment=\"1\"\u003eOutlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 56.4573%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan\u003eHose Nozzle DN 8-10mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 52.5427%;\" data-mce-fragment=\"1\"\u003eCoolant Connection\u003c\/td\u003e\n\u003ctd style=\"width: 56.4573%;\" data-mce-fragment=\"1\"\u003e\u003cspan\u003e2 x Hose Nozzle DN 6-8mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 52.5427%;\" data-mce-fragment=\"1\"\u003eRated Motor Power\u003c\/td\u003e\n\u003ctd style=\"width: 56.4573%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e0.18\u003cspan data-mce-fragment=\"1\"\u003ekW\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 52.5427%;\" data-mce-fragment=\"1\"\u003eRated Motor Speed at 50\/60 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 56.4573%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e1500\/1800\u003cspan data-mce-fragment=\"1\"\u003emin-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 52.5427%;\" data-mce-fragment=\"1\"\u003eProtection Class\u003c\/td\u003e\n\u003ctd style=\"width: 56.4573%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eIP 40\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 52.5427%;\" data-mce-fragment=\"1\"\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd style=\"width: 56.4573%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e435 x 243 x 457\u003cspan data-mce-fragment=\"1\"\u003emm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 52.5427%;\" data-mce-fragment=\"1\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 56.4573%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e17.7\u003cspan data-mce-fragment=\"1\"\u003ekg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 52.5427%;\" data-mce-fragment=\"1\"\u003eNoise Level at 50 Hz, typ.\u003c\/td\u003e\n\u003ctd style=\"width: 56.4573%;\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e45\u003cspan data-mce-fragment=\"1\"\u003edBA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BrandTech Scientific","offers":[{"title":"Default Title","offer_id":43854556725507,"sku":"20733353","price":24507.27,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale)","offer_id":43854556758275,"sku":"20733353","price":19605.81,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/Screenshot2023-04-04102104.png?v=1680618078"},{"product_id":"vacuubrand-mz-2c-nt-chemistry-vacuum-pump-system","title":"VACUUBRAND MZ 2C NT Chemistry Vacuum Pump System","description":"\u003cp style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eBrandTech™ VACUUBRAND™ MZ 2C NT +AK+M+D VARIO Chemistry Manual Vacuum Pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eVACUUBRAND™ MZ 2C NT +AK+M+D VARIO Chemistry Manual Vacuum Pumps are available with manual flow control to provide the most basic management of vacuum where electronic control is unnecessary to achieve good results. Centrifugal concentration, gel drying, and even simple rotary evaporation applications can often be effectively managed with manual control systems. Excellent corrosion resistance with manual control in a single system!\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe new NT-series of pumps provide whisper-quiet and ultra-low-vibration operation, high leak-tightness and improved vacuum. The highly flexible, fabric-reinforced double diaphragm made of FKM offers extended operation life.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual Control Valve\u003c\/strong\u003e\u003cbr\u003eA PTFE diaphragm valve provides approximate control of vacuum levels for less demanding applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Oil Changes\u003c\/strong\u003e\u003cbr\u003eThese vacuum pumps utilize diaphragm vacuum technology. The totally dry operation eliminates the misting, handling and disposal of contaminated waste associated with rotary vane pumps. No oil to change or monitor!\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduced Maintenance\u003c\/strong\u003e\u003cbr\u003eTypical diaphragm lifetimes are well in excess of 15,000 hours of use before replacement - that's years in most applications, minimizing downtime and service costs. When it is finally time for service, their unique design eliminates tedious, trial-and-error stroke length recalibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImproved Productivity\u003c\/strong\u003e\u003cbr\u003eVACUUBRAND\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003epumps are engineered for performance, with flow rates as much as 40% higher at working vacuum level than competitive pumps with similar free air capacity ratings. Higher flow rates mean reduced process times and higher throughput.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliability\u003c\/strong\u003e\u003cbr\u003eAll VACUUBRAND\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003epumps and systems must pass rigorous product testing before leaving the factory. It's your assurance of a reliable pump.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003e \u003cstrong\u003eTechnical Data\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\u003cb\u003eMZ 2C NT +AK+M+D\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eNumber of Heads\/Stages\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e2\/2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e2.0\/2.3\u003cspan data-mce-fragment=\"1\"\u003em3\/h\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e1.2\/1.4\u003cspan data-mce-fragment=\"1\"\u003ecfm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eUltimate Vacuum (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e7\/5\u003cspan data-mce-fragment=\"1\"\u003embar\/torr\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eUltimate Vacuum (abs.) with Gas Ballast\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e12\/9\u003cspan data-mce-fragment=\"1\"\u003embar\/torr\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eAmbient Temperature Range (operation)\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e10 - 40\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eAmbient Temperature Range (storage)\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e-10 - 60\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eMax. Back Pressure (abs.)\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e1.1\u003cspan data-mce-fragment=\"1\"\u003ebar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eInlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003eHose Nozzle DN 8-10mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eOutlet Connection\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e\u003cspan\u003eHose Nozzle DN 8-10mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eRated Motor Power\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e0.18\u003cspan data-mce-fragment=\"1\"\u003ekW\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eRated Motor Speed at 50\/60 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e1500\/1800\u003cspan data-mce-fragment=\"1\"\u003emin-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eProtection Class\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003eIP 40\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e310 x 243 x 313\u003cspan data-mce-fragment=\"1\"\u003emm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e13.4\u003cspan data-mce-fragment=\"1\"\u003ekg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eNoise Level at 50 Hz, typ.\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003e45\u003cspan data-mce-fragment=\"1\"\u003edBA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eNRTL Certification\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003eCanada and the USA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.4386%;\"\u003eATEX Conformity (only 230V)\u003c\/td\u003e\n\u003ctd style=\"width: 50.6422%;\"\u003e\n\u003cp\u003eII 3\/-G Ex h IIC T3 X Internal Atm. only\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"BrandTech Scientific","offers":[{"title":"Default Title","offer_id":43854562951427,"sku":"20732703","price":9520.72,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale)","offer_id":43854562984195,"sku":"20732703","price":7616.58,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/Screenshot2023-04-04103622.png?v=1680618991"},{"product_id":"vacuubrand-md-4c-vario-select-oil-free-chemistry-vacuum-pump","title":"VACUUBRAND MD 4C VARIO Select Oil-Free Chemistry Vacuum Pump","description":"\u003cp style=\"text-align: center;\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eBrandTech™ VACUUBRAND™ MD 4C VARIO Select Oil-Free Chemistry Pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eVACUUBRAND™ MD 4C VARIO Select Oil-Free Chemistry Pumps offer users unsurpassed control of critical vacuum applications. A low maintenance oil-free chemistry-design pump is integrated with a variable speed motor and a mercury-free, digital controller. The system automatically finds and follows boiling curves, continuously optimizing the vacuum level without having to program presets. It's the ultimate productivity tool!\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eEasy-to-use, the VACUU·SELECT\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e controller provides a touch screen, application-based interface. Creating a new application is as easy as swiping a finger to drag-and-drop application building blocks.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVACUU·SELECT\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003econtroller\u003c\/strong\u003e\u003cbr\u003eController has a touch screen interface and predefined applications. It is easy-to-use and the modification of existing applications, or creation of new applications, is simple with drag-and-drop editing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImproved Productivity\u003c\/strong\u003e\u003cbr\u003eThe self-adjusting VARIO\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003esystems require minimal oversight, freeing up time for other work. Plus, their continually optimized vacuum levels speed evaporation by up to 30%!\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Oil Changes\u003c\/strong\u003e\u003cbr\u003eThese vacuum pumps utilize diaphragm vacuum technology. The totally dry operation eliminates the misting, handling and disposal of contaminated waste associated with rotary vane pumps. No oil to change or monitor!\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduced Maintenance\u003c\/strong\u003e\u003cbr\u003eTypical diaphragm lifetimes are well in excess of 15,000 hours of use before replacement - that's years in most applications, minimizing downtime and service costs. When it is finally time for service, their unique design eliminates tedious, trial-and-error stroke length recalibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliability\u003c\/strong\u003e\u003cbr\u003eAll VACUUBRAND\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003epumps and systems must pass rigorous product testing before leaving the factory. It's your assurance of a reliable pump.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVirtually eliminates bumping and foaming, \u003c\/strong\u003eeven with complex processes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduce process time\u003c\/strong\u003e by as much as 30% compared to conventional electronic control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimizes power consumption\u003c\/strong\u003e and maintenance by continuously adjusting motor speed to process demands\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvailable in a wide range of configurations\u003c\/strong\u003e - standard-duty pumps, chemistry-rated pumps, chemistry-rated pumping systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003cstrong\u003eTechnical Data\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMD 4C VARIO\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Controller\u003c\/td\u003e\n\u003ctd\u003eVACUU SELECT\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Heads\/Stages\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\/3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e4.6m3\/h\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax. pumping speed at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e2.7cfm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltimate Vacuum (abs.)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e1.5\/1.1mbar\/torr\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUltimate Vacuum (abs.) with gas ballast\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e3\/2.2mbar\/torr\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature Range (operation)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10 - 40\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature Range (storage)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-10 - 60\u003cb data-mce-fragment=\"1\"\u003e°\u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003eC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Back Pressure (abs.)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1.1\u003cspan data-mce-fragment=\"1\"\u003ebar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInlet Connection\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eHose Nozzle DN 8-10mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Connection\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eHose Nozzle DN 8-10mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Motor Power\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.53\u003cspan data-mce-fragment=\"1\"\u003ekW\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Speed Range\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e30-2400min-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIP 20\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e325 x 243 x 245mm\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e16.8kg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Level at 50 Hz, typ.\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e43dBA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVideo:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ciframe title=\"Evaporation Using VACUUBRAND's Advanced VARIO® Control Technology\" src=\"https:\/\/www.youtube.com\/embed\/rIhOlL1kEUY\" height=\"315\" width=\"560\" allowfullscreen=\"\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" frameborder=\"0\"\u003e\u003c\/iframe\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"BrandTech Scientific","offers":[{"title":"Default Title","offer_id":43894471557379,"sku":"20736553","price":19312.75,"currency_code":"CAD","in_stock":true},{"title":"Default Title (Wholesale)","offer_id":43894471590147,"sku":"20736553","price":15450.2,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/Screenshot2023-04-25141428.png?v=1682446484"}],"url":"https:\/\/cambridgeenviro.com\/collections\/laboratory-vacuum-pumps.oembed","provider":"Cambridge Environmental Products, Inc.","version":"1.0","type":"link"}