{"title":"Hygiena ATP Testing \u0026 Hygiene Monitoring Canada","description":"\n\u003ch2\u003eHygiena ATP Testing \u0026amp; Hygiene Monitoring in Canada\u003c\/h2\u003e\n\n\u003cp\u003eCambridge Environmental supplies Hygiena ATP testing equipment, luminometers, surface and water ATP swabs, protein residue tests, and sanitation verification supplies for Canadian food and beverage manufacturers, breweries, dairies, food processing facilities, sanitation teams, and QA\/QC laboratories.\u003c\/p\u003e\n\n\u003cp\u003eExplore Hygiena EnSURE Touch, UltraSnap, SuperSnap, AquaSnap Total and Free, PRO-Clean, AllerSnap, SpotCheck Plus, ZymoSnap, and compatible accessories. These products help facilities monitor cleaning effectiveness, verify hygiene procedures, and support routine environmental monitoring and food safety programs.\u003c\/p\u003e\n\n\u003cp\u003eNeed help choosing an ATP meter or comparing test swabs? Cambridge Environmental provides Canadian purchasing support, CAD pricing, and assistance selecting products for your sanitation monitoring program.\u003c\/p\u003e\n\n\n\u003ch2\u003eFrequently Asked Questions About Hygiena Testing\u003c\/h2\u003e\n\n\u003cdetails\u003e\n  \u003csummary\u003e\u003cstrong\u003eWhat is Hygiena ATP testing used for?\u003c\/strong\u003e\u003c\/summary\u003e\n  \u003cp\u003eHygiena ATP testing helps food and beverage facilities verify cleaning effectiveness on production equipment, work surfaces, and compatible water samples. Results provide rapid feedback to sanitation and QA\/QC teams so they can identify areas requiring further cleaning or investigation.\u003c\/p\u003e\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n  \u003csummary\u003e\u003cstrong\u003eWhat is the difference between UltraSnap and SuperSnap?\u003c\/strong\u003e\u003c\/summary\u003e\n  \u003cp\u003eUltraSnap (US2020) is designed for routine surface ATP monitoring after cleaning. SuperSnap (SUS3000) is a higher-sensitivity ATP test suited to applications requiring detection of lower ATP levels, including high-risk cleaning verification. Neither test identifies specific allergens or pathogens.\u003c\/p\u003e\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n  \u003csummary\u003e\u003cstrong\u003eWhat is the difference between AquaSnap Total and AquaSnap Free?\u003c\/strong\u003e\u003c\/summary\u003e\n  \u003cp\u003eAquaSnap Total (AQ-100X) measures total ATP in a water sample, including free and microbial ATP. AquaSnap Free (AQ-100FX) measures dissolved, free ATP. Using both tests can help estimate the microbial ATP portion of a water sample. Both are used in water and rinse-water monitoring programs.\u003c\/p\u003e\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n  \u003csummary\u003e\u003cstrong\u003eDo Hygiena ATP swabs require a luminometer?\u003c\/strong\u003e\u003c\/summary\u003e\n  \u003cp\u003eYes. UltraSnap, SuperSnap, and AquaSnap ATP tests require a compatible Hygiena luminometer, such as the EnSURE Touch. Visual residue tests such as PRO-Clean and AllerSnap use colour-change reactions and do not require a luminometer.\u003c\/p\u003e\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n  \u003csummary\u003e\u003cstrong\u003eWhat is the difference between ATP and protein residue testing?\u003c\/strong\u003e\u003c\/summary\u003e\n  \u003cp\u003eATP testing measures a biological residue indicator through a luminometer and reports results in Relative Light Units (RLU). Protein residue tests such as PRO-Clean and AllerSnap use a visual reaction to detect remaining protein. Neither method replaces allergen-specific or microbiological testing where those tests are required.\u003c\/p\u003e\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n  \u003csummary\u003e\u003cstrong\u003eCan Hygiena products be used in breweries and dairy plants?\u003c\/strong\u003e\u003c\/summary\u003e\n  \u003cp\u003eYes. Hygiena hygiene monitoring products are used in food and beverage facilities, including breweries, dairies, wineries, and food processing plants. Depending on the test selected, applications include equipment sanitation checks, production surface monitoring, CIP rinse-water testing, and dairy pasteurization verification.\u003c\/p\u003e\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n  \u003csummary\u003e\u003cstrong\u003eDoes the EnSURE Touch store and report ATP test results?\u003c\/strong\u003e\u003c\/summary\u003e\n  \u003cp\u003eYes. The Hygiena EnSURE Touch supports test plans, location-based monitoring, results management, and reporting through its compatible software system. It is suitable for facilities that need to document sanitation trends and manage routine testing across production areas.\u003c\/p\u003e\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n  \u003csummary\u003e\u003cstrong\u003eCan Cambridge help select a Hygiena ATP testing system?\u003c\/strong\u003e\u003c\/summary\u003e\n  \u003cp\u003eYes. Cambridge Environmental can help Canadian facilities compare Hygiena luminometers, surface ATP swabs, water ATP tests, protein residue tests, and related accessories based on the testing application, expected test volume, reporting requirements, and ongoing consumable costs.\u003c\/p\u003e\n\u003c\/details\u003e\n","products":[{"product_id":"hygiena-ultrasnap-surface-atp-swabs-canada","title":"Hygiena UltraSnap™  - 100 pack","description":"\u003ch2\u003eHygiena UltraSnap Surface ATP Test Swabs - 100 Pack\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eHygiena UltraSnap® US2020\u003c\/strong\u003e is an all-in-one \u003cstrong\u003esurface ATP test swab\u003c\/strong\u003e used with compatible Hygiena luminometers to verify cleaning effectiveness and support sanitation monitoring programs.\u003c\/p\u003e\n\u003cp\u003eDesigned for rapid surface hygiene checks, UltraSnap helps Canadian food processors, beverage plants, breweries, wineries, dairy facilities, cannabis processors, healthcare facilities, pharmaceutical manufacturers, restaurants, sanitation teams, and QA\/QC labs move from visual inspection to fast, documented ATP results.\u003c\/p\u003e\n\u003cdiv style=\"border: 1px solid #d9d9d9; padding: 18px; margin: 24px 0; border-radius: 8px; background: #f8f8f8;\"\u003e\n\u003ch3 style=\"margin-top: 0; font-size: 18px; line-height: 1.35;\"\u003eBuilt for Canadian Sanitation Verification Programs\u003c\/h3\u003e\n\u003cul style=\"margin-bottom: 0;\"\u003e\n\u003cli\u003eFood and beverage surface sanitation checks\u003c\/li\u003e\n\u003cli\u003eBrewery, winery, dairy, and production equipment swabbing\u003c\/li\u003e\n\u003cli\u003ePre-operational hygiene verification before production starts\u003c\/li\u003e\n\u003cli\u003eFood-contact and non-food-contact surface testing\u003c\/li\u003e\n\u003cli\u003eSanitation SOP, HACCP, GMP, audit, and corrective-action programs\u003c\/li\u003e\n\u003cli\u003eQA\/QC teams using Hygiena EnSURE Touch or SystemSURE Plus luminometers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eWhy Choose Hygiena UltraSnap?\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurface ATP testing:\u003c\/strong\u003e Designed for rapid ATP hygiene monitoring on cleaned surfaces, equipment, tools, benches, and production areas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast results:\u003c\/strong\u003e Provides consistent ATP surface test results in approximately 15 seconds when used with a compatible Hygiena luminometer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-in-one swab design:\u003c\/strong\u003e Combines sample collection and reagent in a pen-style test device for simple operator use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-moistened swab bud:\u003c\/strong\u003e Helps improve sample collection from wet or dry surfaces and supports more consistent swabbing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSnap-Valve™ activation:\u003c\/strong\u003e Patented snap-and-squeeze design helps reduce handling steps and makes activation straightforward.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiquid-stable reagent:\u003c\/strong\u003e Designed for sensitivity, reproducibility, and reliable signal strength during routine sanitation verification workflows.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAOAC-RI certified:\u003c\/strong\u003e Hygiena lists UltraSnap as AOAC-RI certified for surface ATP testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e100 tests per pack:\u003c\/strong\u003e Suitable for recurring sanitation programs, routine QA checks, and multi-location swabbing plans.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible with Hygiena luminometers:\u003c\/strong\u003e Use with compatible Hygiena ATP monitoring systems, including EnSURE Touch and SystemSURE Plus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCanadian purchasing support:\u003c\/strong\u003e Supplied by Cambridge Environmental Products with CAD pricing and support for Canadian sanitation and QA\/QC buyers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBest-Fit Applications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 12px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eHow UltraSnap Helps\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eFood processing sanitation\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eHelps QA and sanitation teams verify cleaning effectiveness on selected surfaces before production resumes.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eBreweries, wineries, and beverage plants\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eUseful for swabbing tanks, fillers, transfer points, packaging equipment, drains, tools, and other defined sanitation locations.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eDairy and ready-to-eat production\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eSupports routine hygiene verification in areas where residue control and sanitation documentation are important.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eCannabis and controlled production\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eProvides fast hygiene checks for benches, tools, production rooms, packaging areas, and shared-contact surfaces.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eHealthcare and pharmaceutical environments\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eHelps teams document cleaning verification results across defined test locations and high-touch areas.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eRestaurants and commercial kitchens\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eSupports rapid sanitation checks on food-contact surfaces, prep areas, tools, and cleaned equipment.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eProduct Details\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 12px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eSurface ATP test swab \/ ATP hygiene monitoring device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eHygiena\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eUltraSnap Surface ATP Test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eSKU \/ Product Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eUS2020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eQuantity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e100 tests per pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eSurface samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eResult Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eApproximately 15 seconds when used with a compatible Hygiena luminometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eSwab Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003ePre-moistened swab bud with self-contained liquid-stable reagent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eActivation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eSnap-Valve™ snap-and-squeeze activation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eDetects 0.1 to 1 femtomoles of ATP depending on compatible Hygiena luminometer system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eAOAC-RI certified surface ATP test swab\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eStorage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eRefrigerated storage at 2°C to 8°C recommended for long-term storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eShelf Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e15 months refrigerated at 2°C to 8°C; 4 weeks at room temperature, 21°C to 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eCompatible Instruments\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eCompatible Hygiena luminometers, including EnSURE Touch and SystemSURE Plus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eCommon Applications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eSurface hygiene monitoring, cleaning verification, sanitation verification, pre-operational checks, corrective-action retesting, food safety programs, and QA\/QC documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eUltraSnap vs AquaSnap Selection Note\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eUltraSnap\u003c\/strong\u003e is intended for \u003cstrong\u003esurface ATP testing\u003c\/strong\u003e. Use it for cleaned surfaces, food-contact areas, non-food-contact areas, equipment, tools, benches, drains, and other defined swab locations.\u003c\/p\u003e\n\u003cp\u003eFor \u003cstrong\u003ewater or liquid samples\u003c\/strong\u003e, use AquaSnap water ATP test devices instead. Choose \u003ca href=\"\/products\/atp-testing-aq-100x\"\u003eHygiena AquaSnap Total ATP Water Test Swabs\u003c\/a\u003e for total ATP in water, or \u003ca href=\"\/products\/atp-testing-aq-100fx\"\u003eHygiena AquaSnap Free ATP Water Test Swabs\u003c\/a\u003e for dissolved free ATP.\u003c\/p\u003e\n\u003cdiv style=\"border: 1px solid #d9d9d9; padding: 18px; margin: 24px 0; border-radius: 8px; background: #fff8e5;\"\u003e\n\u003ch3 style=\"margin-top: 0; font-size: 18px; line-height: 1.35;\"\u003eTest Selection Note\u003c\/h3\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003eUse UltraSnap for surface ATP testing. Do not use UltraSnap as a substitute for AquaSnap when your sample is water, CIP rinse water, process water, or another liquid sample.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003ePair with the Hygiena EnSURE Touch Luminometer\u003c\/h2\u003e\n\u003cp\u003eUltraSnap surface ATP swabs require a compatible Hygiena luminometer. For a complete ATP sanitation verification setup, pair US2020 with the \u003ca href=\"\/products\/hygiena-ensure-touch-luminometer\"\u003eHygiena EnSURE Touch ATP Luminometer\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eCambridge Environmental Products can help Canadian buyers confirm the right Hygiena luminometer, surface ATP swabs, water ATP tests, calibration verification tools, and sanitation monitoring consumables for their program.\u003c\/p\u003e\n\u003ch2\u003eUse and Handling Notes\u003c\/h2\u003e\n\u003cp\u003eAllow UltraSnap swabs to equilibrate to room temperature before testing. Swab the selected test area according to your facility procedure, activate the device using the Snap-Valve™ mechanism, mix according to the instructions, and read the result using a compatible Hygiena luminometer.\u003c\/p\u003e\n\u003cp\u003eStore UltraSnap refrigerated at 2°C to 8°C for long-term storage. For short-term use, follow the product instructions and your internal storage procedure. Hygiena recommends a quick shipping method due to temperature sensitivity and refrigeration after receipt for long-term storage.\u003c\/p\u003e\n\u003cp\u003eUltraSnap provides rapid ATP hygiene monitoring data. It does not replace required microbiological testing, pathogen testing, allergen testing, regulatory testing, or facility-specific verification methods where those are required by your SOP, customer requirements, audit program, or applicable standard.\u003c\/p\u003e\n\u003ch2\u003eCanadian Purchasing Support\u003c\/h2\u003e\n\u003cp\u003eCambridge Environmental Products supplies Hygiena UltraSnap US2020 surface ATP test swabs in Canada with CAD pricing, Canadian purchasing support, and access to related Hygiena ATP luminometers, AquaSnap water ATP tests, calibration verification tools, and sanitation monitoring supplies.\u003c\/p\u003e\n\u003ch2\u003eCommon Questions About Hygiena UltraSnap US2020\u003c\/h2\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eWhat is Hygiena UltraSnap used for?\u003c\/h3\u003e\n\u003cp\u003eUltraSnap is used for rapid ATP surface testing and sanitation verification on cleaned surfaces, equipment, tools, benches, production areas, and other defined hygiene monitoring locations.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eHow many swabs are in a pack?\u003c\/h3\u003e\n\u003cp\u003eUS2020 includes 100 UltraSnap surface ATP test swabs per pack.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eHow fast are the results?\u003c\/h3\u003e\n\u003cp\u003eUltraSnap provides ATP surface test results in approximately 15 seconds when used with a compatible Hygiena luminometer.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eIs UltraSnap used for surface testing or water testing?\u003c\/h3\u003e\n\u003cp\u003eUltraSnap is used for surface ATP testing. For water, CIP rinse water, process water, or other liquid samples, use Hygiena AquaSnap water ATP test devices instead.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eDoes UltraSnap work with EnSURE Touch?\u003c\/h3\u003e\n\u003cp\u003eYes. UltraSnap is designed for use with compatible Hygiena luminometers, including the Hygiena EnSURE Touch ATP Luminometer.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eCan UltraSnap be used in breweries?\u003c\/h3\u003e\n\u003cp\u003eYes. Breweries and beverage plants can use UltraSnap for surface ATP checks on selected sanitation points such as tanks, fillers, packaging areas, tools, drains, benches, and cleaned equipment.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eCan UltraSnap be used on wet and dry surfaces?\u003c\/h3\u003e\n\u003cp\u003eYes. UltraSnap is listed for testing wet or dry surfaces.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eHow should UltraSnap be stored?\u003c\/h3\u003e\n\u003cp\u003eStore UltraSnap refrigerated at 2°C to 8°C for long-term storage. The listed shelf life is 15 months refrigerated, with a 4-week room temperature shelf life at 21°C to 25°C.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eDoes UltraSnap replace microbiology testing?\u003c\/h3\u003e\n\u003cp\u003eNo. UltraSnap provides rapid ATP hygiene monitoring data, but it does not replace required microbiological testing, pathogen testing, allergen testing, finished product testing, or other required laboratory methods.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eWhere can I buy Hygiena UltraSnap in Canada?\u003c\/h3\u003e\n\u003cp\u003eCambridge Environmental Products supplies Hygiena UltraSnap US2020 surface ATP test swabs in Canada with CAD pricing and support for food processors, beverage plants, breweries, dairy facilities, healthcare facilities, pharmaceutical manufacturers, cannabis processors, restaurants, sanitation teams, and QA\/QC labs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration-line: underline;\"\u003e\u003cbr\u003eAvailable Literature:\u003cbr\u003e\u003ca href=\"https:\/\/www.hygiena.com\/documents\/62391\/ultrasnap-product-sheet-en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUS2020 Datasheet\u003c\/a\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e \u003ca href=\"https:\/\/www.hygiena.com\/documents\/64066\/ultrasnap-instructions-en.pdf\" rel=\"noopener\" target=\"_blank\"\u003eUS2020 Instructions\u003c\/a\u003e \u003cbr\u003e\u003ca href=\"https:\/\/www.hygiena.com\/documents\/100716\/ultrasnap-us2020-sds-ca-en.pdf\" rel=\"noopener\" target=\"_blank\"\u003eUS2020 Safety Data Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"Cambridge Environmental Products, Inc.","offers":[{"title":"Default Title","offer_id":238440185882,"sku":"US2020","price":447.32,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/us2020_a795fc59-b34a-409d-8b8e-815cfc133fc7.jpg?v=1569173909"},{"product_id":"hygiena-ensure-touch-atp-luminometer","title":"Hygiena EnSURE Touch Luminometer","description":"\u003ch2\u003eHygiena EnSURE Touch ATP Luminometer\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHygiena EnSURE® Touch ATP Luminometer\u003c\/strong\u003e is a handheld hygiene monitoring system designed to help facilities verify cleaning effectiveness, document sanitation results, and manage environmental monitoring programs with fast, objective test data.\u003c\/p\u003e\n\u003cp\u003eBuilt around a \u003cstrong\u003e5-inch touchscreen\u003c\/strong\u003e, Wi-Fi connectivity, USB data transfer, rechargeable battery power, and SureTrend® Cloud syncing, EnSURE Touch is a strong fit for Canadian food processors, beverage producers, breweries, dairy facilities, cannabis processors, healthcare facilities, pharmaceutical manufacturers, sanitation teams, and QA\/QC laboratories.\u003c\/p\u003e\n\u003cdiv style=\"border: 1px solid #d9d9d9; padding: 18px; margin: 24px 0; border-radius: 8px; background: #f8f8f8;\"\u003e\n\u003ch3 style=\"margin-top: 0; font-size: 18px; line-height: 1.35;\"\u003eBuilt for Canadian Sanitation Verification and QA\/QC Programs\u003c\/h3\u003e\n\u003cul style=\"margin-bottom: 0;\"\u003e\n\u003cli\u003eFood and beverage sanitation verification\u003c\/li\u003e\n\u003cli\u003eBrewery, winery, dairy, and beverage production hygiene checks\u003c\/li\u003e\n\u003cli\u003eSurface ATP testing after cleaning and before production\u003c\/li\u003e\n\u003cli\u003eHealthcare, pharmaceutical, cannabis, and controlled production environments\u003c\/li\u003e\n\u003cli\u003eHACCP, GMP, sanitation SOP, audit, and corrective-action documentation\u003c\/li\u003e\n\u003cli\u003eMulti-site quality teams that need centralized reports and trend tracking\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eWhy Choose the Hygiena EnSURE Touch?\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast sanitation verification:\u003c\/strong\u003e Provides rapid ATP hygiene monitoring results so staff can confirm cleaning effectiveness before moving forward with production or release decisions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5-inch touchscreen interface:\u003c\/strong\u003e Smartphone-style touchscreen design makes the system easier for operators, sanitation teams, and QA staff to use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePass, caution, and fail notifications:\u003c\/strong\u003e Helps teams turn raw ATP results into practical on-site decisions based on defined limits and test locations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustom test locations and plans:\u003c\/strong\u003e Create and manage test points, pass\/fail limits, users, and site-specific sanitation programs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRandomized testing support:\u003c\/strong\u003e Helps prevent “same spot every time” testing by supporting randomized test locations and planned sampling coverage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrective-action retesting:\u003c\/strong\u003e Failed locations can be retested to show whether corrective cleaning has been effective.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSureTrend® Cloud syncing:\u003c\/strong\u003e Wirelessly sync results for reporting, trend analysis, user management, and multi-location data visibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple Hygiena test options:\u003c\/strong\u003e Supports ATP testing and other compatible Hygiena rapid test devices depending on the application and test program.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotodiode sensor technology:\u003c\/strong\u003e Uses durable, energy-efficient photodiode technology instead of a bulky photomultiplier tube design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCanadian purchasing support:\u003c\/strong\u003e Supplied by Cambridge Environmental Products with CAD pricing and support from a Canadian-owned company.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBest-Fit Applications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 12px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eHow EnSURE Touch Helps\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eFood processing sanitation\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eHelps QA and sanitation teams verify cleaned food-contact and non-food-contact surfaces before production restarts.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eBreweries, wineries, and beverage plants\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eUseful for checking cleaned tanks, fillers, transfer lines, packaging areas, drains, and other sanitation points where visual checks alone are not enough.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eDairy and ready-to-eat production\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eSupports routine hygiene verification in facilities where residue control and sanitation documentation are important.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eCannabis and controlled production\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eProvides rapid hygiene checks for production rooms, packaging areas, tools, benches, and shared-contact surfaces.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eHealthcare and pharmaceutical environments\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eHelps teams document cleaning verification and monitor hygiene programs across defined test locations.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eMulti-site QA\/QC programs\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eCloud syncing and centralized reporting help quality teams review results, trends, retests, and corrective actions across multiple areas or facilities.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eCompatible Hygiena Test Program Options\u003c\/h2\u003e\n\u003cp\u003eEnSURE Touch can be used as the central instrument for multiple Hygiena rapid test workflows. The correct test device depends on whether you are checking surfaces, water, indicator organisms, process efficiency, or another hygiene monitoring requirement.\u003c\/p\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 12px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eTest Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eExamples\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eTypical Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eSurface ATP testing\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eUltraSnap®, SuperSnap®\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eCleaning verification for food-contact surfaces, equipment, tools, benches, and production areas.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eWater ATP testing\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eAquaSnap®\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eRinse water, process water, CIP-related checks, and liquid hygiene monitoring workflows.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eIndicator organism testing\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eMicroSnap®\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eTesting workflows for organisms such as coliforms, E. coli, Enterobacteriaceae, and total viable count when using compatible Hygiena devices.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eProcess efficiency testing\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eZymoSnap® ALP \/ ACP\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003ePasteurization or cooking efficiency workflows using compatible enzyme test devices.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eCalibration verification\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eCalCheck\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eIn-house instrument verification as part of a quality control program.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"border: 1px solid #d9d9d9; padding: 18px; margin: 24px 0; border-radius: 8px; background: #fff8e5;\"\u003e\n\u003ch3 style=\"margin-top: 0; font-size: 18px; line-height: 1.35;\"\u003eImportant Test Selection Note\u003c\/h3\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003eThe EnSURE Touch luminometer is the instrument. Swabs, test devices, calibration verification tools, and consumables are sold separately unless specifically included in a kit or quote. Contact Cambridge Environmental Products before ordering if you need help matching the correct Hygiena test devices to your sanitation program.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eHygiena EnSURE Touch Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 12px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eATP hygiene monitoring luminometer \/ sanitation verification system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eHygiena\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eEnSURE Touch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eSKU \/ Product Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eETOUCH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eResult Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eATP cleaning verification results in approximately 10 seconds when used with compatible Hygiena ATP test devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eScreen\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e5-inch touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eSize\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e7 x 3 x 1 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e0.7 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eATP Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eLess than 1 femtomole of ATP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e2 GB internal memory plus cloud-based storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eConnectivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eUSB or Wi-Fi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eSoftware\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eSureTrend® Cloud data analysis and reporting platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eRechargeable lithium-ion battery with USB-C charging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eLanguages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eSupports multiple languages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px; background: #f8f8f8;\"\u003e\u003cstrong\u003eCommon Applications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eATP sanitation verification, environmental monitoring, cleaning verification, corrective-action retesting, audit support, food safety programs, and QA\/QC documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWhat EnSURE Touch Helps Improve\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCleaning verification after sanitation\u003c\/li\u003e\n\u003cli\u003ePre-operational hygiene checks\u003c\/li\u003e\n\u003cli\u003eCorrective-action documentation after failed results\u003c\/li\u003e\n\u003cli\u003eAudit readiness and sanitation records\u003c\/li\u003e\n\u003cli\u003eOperator training and cleaning accountability\u003c\/li\u003e\n\u003cli\u003eTrend analysis across test locations\u003c\/li\u003e\n\u003cli\u003eMulti-department and multi-site quality visibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eATP Testing and Program Notes\u003c\/h2\u003e\n\u003cp\u003eATP testing is a rapid hygiene monitoring method. It helps identify organic residue and potential cleaning issues by measuring ATP from biological material. It is especially useful when a facility needs fast feedback after cleaning, before production begins, or during sanitation verification checks.\u003c\/p\u003e\n\u003cp\u003eATP results should be used as part of a complete sanitation and quality program. ATP hygiene monitoring does not replace required microbiological testing, allergen testing, finished product testing, environmental monitoring, or regulatory testing where those methods are required by your SOP, customer requirement, audit program, or applicable standard.\u003c\/p\u003e\n\u003cp\u003eFor best results, facilities should define test locations, pass\/caution\/fail limits, retest procedures, corrective actions, sampling frequency, user roles, and reporting responsibilities before launching a hygiene monitoring program.\u003c\/p\u003e\n\u003cdiv style=\"border: 1px solid #d9d9d9; padding: 18px; margin: 24px 0; border-radius: 8px; background: #f8f8f8;\"\u003e\n\u003ch3 style=\"margin-top: 0; font-size: 18px; line-height: 1.35;\"\u003eCanadian Buyer Note\u003c\/h3\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003eFor Canadian food, beverage, brewery, dairy, cannabis, healthcare, and pharmaceutical facilities, EnSURE Touch can help move sanitation checks from subjective visual inspection to documented, repeatable, and trendable hygiene verification data.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eCanadian Purchasing Support\u003c\/h2\u003e\n\u003cp\u003eCambridge Environmental Products supplies the Hygiena EnSURE Touch ATP Luminometer in Canada with CAD pricing, Canadian purchasing support, and access to compatible Hygiena swabs, ATP test devices, water ATP tests, calibration verification tools, and sanitation monitoring supplies.\u003c\/p\u003e\n\u003ch2\u003eCommon Questions About the Hygiena EnSURE Touch ATP Luminometer\u003c\/h2\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eWhat is the Hygiena EnSURE Touch used for?\u003c\/h3\u003e\n\u003cp\u003eThe EnSURE Touch is used for ATP hygiene monitoring, sanitation verification, cleaning effectiveness checks, environmental monitoring support, corrective-action retesting, and QA\/QC documentation.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eHow fast are ATP results?\u003c\/h3\u003e\n\u003cp\u003eEnSURE Touch provides ATP cleaning verification results in approximately 10 seconds when used with compatible Hygiena ATP test devices.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eWhat industries use EnSURE Touch?\u003c\/h3\u003e\n\u003cp\u003eCommon users include food processors, beverage producers, breweries, dairy facilities, cannabis processors, pharmaceutical manufacturers, healthcare facilities, restaurants, supermarkets, sanitation service providers, research labs, and QA\/QC teams.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eDoes the EnSURE Touch work with UltraSnap swabs?\u003c\/h3\u003e\n\u003cp\u003eYes. EnSURE Touch is used with compatible Hygiena ATP test devices such as UltraSnap surface ATP swabs. Confirm the correct swab or test device for your sample type before ordering.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eCan EnSURE Touch be used for breweries?\u003c\/h3\u003e\n\u003cp\u003eYes. Breweries and beverage facilities can use EnSURE Touch for rapid sanitation verification on selected surfaces, equipment, tanks, transfer areas, fillers, packaging areas, and other defined hygiene monitoring points.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eCan EnSURE Touch test water samples?\u003c\/h3\u003e\n\u003cp\u003eYes, EnSURE Touch can be used with compatible Hygiena water ATP test devices such as AquaSnap when water or liquid ATP testing is required.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eDoes EnSURE Touch replace microbiology testing?\u003c\/h3\u003e\n\u003cp\u003eNo. ATP hygiene monitoring provides rapid sanitation verification data, but it does not replace microbiological testing, pathogen testing, allergen testing, finished product release testing, or other required laboratory methods.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eDoes EnSURE Touch connect to cloud software?\u003c\/h3\u003e\n\u003cp\u003eYes. EnSURE Touch can sync wirelessly with SureTrend Cloud for centralized reporting, trend analysis, user management, and test program visibility.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eAre swabs included with the luminometer?\u003c\/h3\u003e\n\u003cp\u003eSwabs and compatible test devices are typically ordered separately unless they are included in a specific kit or quote. Contact Cambridge Environmental Products if you need help building a complete EnSURE Touch starter setup.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 18px; line-height: 1.35;\"\u003eWhere can I buy the Hygiena EnSURE Touch in Canada?\u003c\/h3\u003e\n\u003cp\u003eCambridge Environmental Products supplies the Hygiena EnSURE Touch ATP Luminometer in Canada with CAD pricing and support for food, beverage, brewery, dairy, healthcare, pharmaceutical, cannabis, sanitation, and QA\/QC buyers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration-line: underline;\"\u003e\u003cbr\u003eAvailable Literature:\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/ensure-touch-fb-brochure.pdf?v=1750430720\" rel=\"noopener\" target=\"_blank\"\u003eEnSURE Touch Food \u0026amp; Beverage Brochure\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/ensure-touch-product-sheet-en.pdf?v=1750430722\" rel=\"noopener\" target=\"_blank\"\u003eEnSURE Touch Product Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/ensure-touch-instructions-en.pdf?v=1750430727\" rel=\"noopener\" target=\"_blank\"\u003eEnSURE Touch Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv style=\"border: 1px solid #d9d9d9; padding: 22px; margin-top: 32px; border-radius: 8px; background: #f8f8f8;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eNeed Help Building an ATP Testing Program?\u003c\/h2\u003e\n\u003cp\u003eNot sure which Hygiena swabs, test devices, calibration tools, or starter supplies you need with the EnSURE Touch? Cambridge Environmental Products can help Canadian buyers build a practical sanitation verification setup for food, beverage, brewery, healthcare, pharmaceutical, cannabis, and QA\/QC facilities.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContact us before ordering if you need help matching the EnSURE Touch to your sanitation SOP, test locations, sample type, swab requirements, or reporting workflow.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003ca href=\"\/pages\/contact\" style=\"display: inline-block; padding: 12px 18px; background: #1f4e79; color: #ffffff; text-decoration: none; border-radius: 5px; font-weight: bold;\"\u003e Contact Cambridge for Hygiena ATP Support \u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Hygiena","offers":[{"title":"Default Title","offer_id":46950934413571,"sku":"Etouch","price":4008.08,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/pf-ensure-touch-fss.webp?v=1793278197"},{"product_id":"hygiena-supersnap-high-sensitivity-atp-test","title":"Hygiena SuperSnap® High Sensitivity Surface ATP Test – 100 Tests","description":"\u003ch2\u003eHygiena SuperSnap® High Sensitivity Surface ATP Test – 100 Tests\u003c\/h2\u003e\n\n\u003cp\u003eHygiena SuperSnap is Hygiena's most sensitive surface ATP test. It's a single-use swab with a built-in liquid-stable reagent that detects very low levels of ATP, the energy molecule found in food residue, microorganisms and other organic matter. Swab the surface, snap and squeeze to activate, then read the result in a Hygiena luminometer in about 10 to 15 seconds. You can confirm a surface is clean before production starts, instead of waiting for lab results.\u003c\/p\u003e\n\n\u003cp\u003eSuperSnap is designed for sites with the strictest hygiene standards, such as high-risk food and beverage production, where a standard ATP swab may not pick up low-level residue. It's sold in boxes of 100 tests and works with all Hygiena luminometers, including the EnSURE Touch, EnSURE and SystemSURE Plus. Hygiena SuperSnap is available in Canada from Cambridge Environmental Products with CAD pricing and Canadian purchasing support.\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003ch3 style=\"font-size:18px; line-height:1.35; margin-top:0;\"\u003eIdeal For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFood and beverage processing\u003c\/strong\u003e: verifying cleaning of food-contact surfaces before start-up\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-risk and ready-to-eat production areas\u003c\/strong\u003e that need very low pass thresholds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSanitation SOP verification\u003c\/strong\u003e and pre-operational inspections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHACCP and preventive control programs\u003c\/strong\u003e that use ATP as a cleaning verification tool\u003c\/li\u003e\n\u003cli\u003eSites already using \u003cstrong\u003eHygiena luminometers\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eWhy Choose SuperSnap?\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHygiena's most sensitive surface ATP test\u003c\/h3\u003e\n\u003cp\u003eHygiena states SuperSnap is 4 times more sensitive than its UltraSnap surface test. Higher sensitivity means the test can pick up smaller amounts of residue, so you can set tighter pass limits on critical surfaces.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eResistant to sanitizer effects\u003c\/h3\u003e\n\u003cp\u003eLeftover sanitizer can suppress the ATP reaction and give falsely low readings. Hygiena states the SuperSnap reagent is 5 times more resistant to acid-based sanitizers and 10 times more resistant to alkali-based sanitizers.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eResults in seconds\u003c\/h3\u003e\n\u003cp\u003eResults take about 10 seconds on the EnSURE Touch and 15 seconds on the EnSURE or SystemSURE Plus. Staff can re-clean and re-test a surface on the spot instead of waiting for lab results.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eAll-in-one device\u003c\/h3\u003e\n\u003cp\u003eThe swab, reagent and cuvette are in one self-contained device, so there's no pipetting or separate reagent to handle. Hygiena's patented swab design is built for high sample collection and recovery, and the plastic is 100% recyclable.\u003c\/p\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003col style=\"margin:0;\"\u003e\n\u003cli\u003eLet the device warm to room temperature (21–25 °C) before use.\u003c\/li\u003e\n\u003cli\u003eTwist and pull the swab out of the tube.\u003c\/li\u003e\n\u003cli\u003eSwab a 10 × 10 cm area in a crisscross pattern, rotating the swab and pressing firmly enough to flex the shaft.\u003c\/li\u003e\n\u003cli\u003eReturn the swab to the tube.\u003c\/li\u003e\n\u003cli\u003eBend the bulb back and forth to break the Snap-Valve, then squeeze the bulb twice to release the liquid.\u003c\/li\u003e\n\u003cli\u003eShake for 5 to 10 seconds to soak the swab tip.\u003c\/li\u003e\n\u003cli\u003eInsert the device into the luminometer and start the reading \u003cstrong\u003ewithin 30 seconds\u003c\/strong\u003e of activating it.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003eSteps are from the Hygiena SuperSnap instructions for use. Set pass, caution and fail limits (RLU) for each test point in your luminometer software, based on your own sanitation program.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eCommon Applications\u003c\/h2\u003e\n\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eApplication\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eHow SuperSnap Helps\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003ePre-operational inspection\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eConfirms food-contact surfaces are clean before production starts.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eHigh-risk and RTE areas\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eHigher sensitivity supports tighter pass limits on critical surfaces.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSanitation verification\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eReagent resists acid and alkali sanitizer residues that can suppress results.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eTrend monitoring\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eResults can be logged and trended with Hygiena luminometer software.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSuperSnap® High Sensitivity Surface ATP Test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eItem number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eASY0222 (Hygiena reference SUS3000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003ePack\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e100 tests per box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eTest type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSurface ATP (cleaning verification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e4× more sensitive than UltraSnap (per Hygiena)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eSanitizer resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e5× more resistant to acid-based and 10× more resistant to alkali-based sanitizers (per Hygiena)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eRead time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eAbout 10 s (EnSURE Touch); 15 s (EnSURE, SystemSURE Plus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eCompatible instruments\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eAll Hygiena luminometers, including EnSURE Touch, EnSURE and SystemSURE Plus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eStorage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e2–8 °C (36–46 °F); up to 4 weeks at 20–25 °C before use; keep out of direct sunlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eShelf life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eUse by the expiry date on the label\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eUse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSingle use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eHygiena\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cem\u003eSpecifications are from the Hygiena SuperSnap product sheet, instructions for use and Hygiena product listing.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eSelection \u0026amp; Handling Notes\u003c\/h2\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#fff8e5;\"\u003e\n\u003cul style=\"margin:0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerate on receipt.\u003c\/strong\u003e Store at 2–8 °C. Devices can be kept at room temperature for up to 4 weeks before use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRead within 30 seconds\u003c\/strong\u003e of activating the device, or results may not be accurate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDon't swab visibly dirty surfaces.\u003c\/strong\u003e Heavy soil overloads the swab and inhibits the reaction. Clean first, then verify.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDon't touch the swab tip\u003c\/strong\u003e or the inside of the device. ATP from skin will raise the reading.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequires a luminometer.\u003c\/strong\u003e SuperSnap must be read in a Hygiena luminometer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle use only.\u003c\/strong\u003e See the Safety Data Sheet for handling and disposal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eProduct Documents\u003c\/h2\u003e\n\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hygiena.com\/documents\/62376\/supersnap-product-sheet-en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHygiena SuperSnap Product Sheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hygiena.com\/documents\/64071\/supersnap-instructions-en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHygiena SuperSnap Instructions for Use (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed the Safety Data Sheet or a certificate of analysis for a specific lot? \u003ca href=\"\/pages\/contact\"\u003eContact Cambridge\u003c\/a\u003e and we'll request it from Hygiena.\u003c\/p\u003e\n\n\u003ch2\u003eCanadian Purchasing Support\u003c\/h2\u003e\n\u003cp\u003eCambridge Environmental Products is a Canadian-owned laboratory supply distributor based in Ontario and has served Canadian labs since 1993. We supply Hygiena ATP tests with CAD pricing and shipping across Canada. We work with food and beverage processors, QA\/QC teams, sanitation managers, and research laboratories, and can help with quotes and standing orders. Browse our \u003ca href=\"\/collections\/lab-supplies\"\u003elab supplies\u003c\/a\u003e collection for more.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhat does SuperSnap measure?\u003c\/h3\u003e\n\u003cp\u003eIt measures ATP (adenosine triphosphate), which is found in food residue, microorganisms and other organic matter. The luminometer reports the result in relative light units (RLU). A higher reading means more residue on the surface.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHow is SuperSnap different from UltraSnap?\u003c\/h3\u003e\n\u003cp\u003eSuperSnap is Hygiena's high sensitivity surface test. Hygiena states it's 4 times more sensitive than UltraSnap and more resistant to sanitizer effects. It suits sites that need tighter pass limits.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhich luminometers does it work with?\u003c\/h3\u003e\n\u003cp\u003eAll Hygiena luminometers, including the EnSURE Touch, EnSURE and SystemSURE Plus. It isn't designed for other brands' luminometers.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHow should I store it?\u003c\/h3\u003e\n\u003cp\u003eRefrigerate at 2–8 °C. Devices can be kept at room temperature (20–25 °C) for up to 4 weeks before use. Let them reach room temperature before testing.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eDoes SuperSnap detect bacteria?\u003c\/h3\u003e\n\u003cp\u003eIt detects ATP from all organic sources, including bacteria, but it isn't a bacteria count. Use it to verify cleaning, and use microbiological testing to confirm specific organisms.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHow many tests are in a box?\u003c\/h3\u003e\n\u003cp\u003e100 single-use tests.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eIs SuperSnap available in Canada?\u003c\/h3\u003e\n\u003cp\u003eYes. Cambridge Environmental Products supplies Hygiena SuperSnap across Canada with CAD pricing.\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003ch3 style=\"font-size:18px; line-height:1.35; margin-top:0;\"\u003eNeed Help Setting Up ATP Testing?\u003c\/h3\u003e\n\u003cp\u003eTell us:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe luminometer you use\u003c\/li\u003e\n\u003cli\u003eThe surfaces and areas you test\u003c\/li\u003e\n\u003cli\u003eYour current pass\/fail limits\u003c\/li\u003e\n\u003cli\u003eHow many tests you use per month\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe'll help you choose the right Hygiena test and set up standing orders.\u003c\/p\u003e\n\u003ca href=\"\/pages\/contact\" style=\"display:inline-block; padding:12px 18px; background:#1f4e79; color:#ffffff; text-decoration:none; border-radius:5px; font-weight:bold;\"\u003e\nContact Cambridge for Product Support\n\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Hygiena","offers":[{"title":"Default Title","offer_id":50047687852291,"sku":"SUS3000","price":634.91,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/SuperSnap.webp?v=1793196481"},{"product_id":"hygiena-ensure-touch-charging-dock","title":"Hygiena EnSURE® Touch Charging Dock","description":"\u003ch2\u003eHygiena EnSURE® Touch Charging Dock\u003c\/h2\u003e\n\n\u003cp\u003eThe Hygiena EnSURE Touch Charging Dock is a drop-in cradle for charging the EnSURE Touch ATP luminometer. You don't need to plug a cable into the instrument each time. Set the EnSURE Touch in the dock and it charges, and an LED shows when it's charging (orange) and when it's ready (green). That means less wear on the instrument's USB-C port and a set place to keep the luminometer between shifts.\u003c\/p\u003e\n\n\u003cp\u003eThe dock has a small footprint and works with the EnSURE Touch with or without its protective cover or case. It's powered by the USB-C cable and power adapter supplied with the EnSURE Touch. The Hygiena charging dock is available in Canada from Cambridge Environmental Products with CAD pricing and Canadian purchasing support.\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003ch3 style=\"font-size:18px; line-height:1.35; margin-top:0;\"\u003eIdeal For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFood and beverage plants\u003c\/strong\u003e using the EnSURE Touch for daily ATP cleaning verification\u003c\/li\u003e\n\u003cli\u003eSites that share a luminometer between \u003cstrong\u003eshifts or sanitation crews\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eKeeping the luminometer \u003cstrong\u003echarged and in one place\u003c\/strong\u003e between uses\u003c\/li\u003e\n\u003cli\u003eReducing \u003cstrong\u003ewear on the USB-C port\u003c\/strong\u003e from repeated plugging in\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eWhy Choose the EnSURE Touch Charging Dock?\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eDrop-in charging\u003c\/h3\u003e\n\u003cp\u003eSet the EnSURE Touch in the cradle and it starts charging. There's no fiddling with a cable at the end of a shift, so the instrument is more likely to be charged when the next crew needs it.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eProtects the USB-C port\u003c\/h3\u003e\n\u003cp\u003ePlugging a cable in and out every day wears the port. The dock takes that handling off the instrument.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eCharging status at a glance\u003c\/h3\u003e\n\u003cp\u003eThe indicator light glows orange while the instrument is charging and green when it's fully charged.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWorks with covers and cases\u003c\/h3\u003e\n\u003cp\u003eHygiena states the dock works with the EnSURE Touch with or without its protective cover and with or without its protective case.\u003c\/p\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003col style=\"margin:0;\"\u003e\n\u003cli\u003eConnect the Hygiena USB-C cable and power adapter (supplied with the EnSURE Touch) to the dock.\u003c\/li\u003e\n\u003cli\u003eSet the EnSURE Touch in the cradle.\u003c\/li\u003e\n\u003cli\u003eCheck the indicator: orange means charging, green means fully charged.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eItem number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eASY0505 (Hygiena product code EDOCK)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eCompatible with\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eHygiena EnSURE Touch luminometer, with or without protective cover or case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eHygiena USB-C cable (MIS0150) and power adapter (MIS0151), supplied with the EnSURE Touch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eIndicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eLED: orange = charging; green = fully charged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e0 °C to 45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e20% to 85%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eSold as\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eEach\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eHygiena\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cem\u003eSpecifications are from the Hygiena charging dock instructions and Hygiena product listings.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eSelection \u0026amp; Handling Notes\u003c\/h2\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#fff8e5;\"\u003e\n\u003cul style=\"margin:0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply not included.\u003c\/strong\u003e The dock uses the USB-C cable and power adapter that come with the EnSURE Touch. If you need a second set for the dock, contact Cambridge.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse Hygiena-approved power parts only.\u003c\/strong\u003e Hygiena warns that other adapters may damage the device.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnSURE Touch only.\u003c\/strong\u003e The dock is designed for the EnSURE Touch, not the older EnSURE or SystemSURE Plus luminometers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisposal:\u003c\/strong\u003e dispose of the dock as electronic waste, not in regular garbage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eProduct Documents\u003c\/h2\u003e\n\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hygiena.com\/documents\/68801\/ensure-touch-charging-dock-instructions-en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHygiena EnSURE Touch Charging Dock Instructions (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCanadian Purchasing Support\u003c\/h2\u003e\n\u003cp\u003eCambridge Environmental Products is a Canadian-owned laboratory supply distributor based in Ontario and has served Canadian labs since 1993. We supply Hygiena ATP monitoring systems, tests and accessories with CAD pricing and shipping across Canada. We work with food and beverage processors, QA\/QC teams, sanitation managers, and research laboratories. Browse our \u003ca href=\"\/collections\/lab-supplies\"\u003elab supplies\u003c\/a\u003e collection for more.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhat does the charging dock do?\u003c\/h3\u003e\n\u003cp\u003eIt charges the EnSURE Touch luminometer when you set it in the cradle, so you don't need to plug a cable into the instrument each time.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eDoes it come with a power adapter?\u003c\/h3\u003e\n\u003cp\u003eNo. It uses the Hygiena USB-C cable and power adapter supplied with the EnSURE Touch. Contact Cambridge if you need a separate set.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWill it fit my EnSURE Touch with a cover or case on?\u003c\/h3\u003e\n\u003cp\u003eYes. Hygiena states the dock works with or without the protective cover and case.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eDoes it work with the original EnSURE or SystemSURE Plus?\u003c\/h3\u003e\n\u003cp\u003eNo. It's designed for the EnSURE Touch.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhat do the lights mean?\u003c\/h3\u003e\n\u003cp\u003eOrange means the instrument is charging. Green means it's fully charged.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eIs the dock available in Canada?\u003c\/h3\u003e\n\u003cp\u003eYes. Cambridge Environmental Products supplies the Hygiena EnSURE Touch Charging Dock across Canada with CAD pricing.\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003ch3 style=\"font-size:18px; line-height:1.35; margin-top:0;\"\u003eNeed Help with Your Hygiena System?\u003c\/h3\u003e\n\u003cp\u003eTell us:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe Hygiena luminometer you use\u003c\/li\u003e\n\u003cli\u003eWhether you need spare cables or power adapters\u003c\/li\u003e\n\u003cli\u003eWhich ATP tests you use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe'll help you find the right accessories and tests.\u003c\/p\u003e\n\u003ca href=\"\/pages\/contact\" style=\"display:inline-block; padding:12px 18px; background:#1f4e79; color:#ffffff; text-decoration:none; border-radius:5px; font-weight:bold;\"\u003e\nContact Cambridge for Product Support\n\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Hygiena","offers":[{"title":"Default Title","offer_id":50048154173699,"sku":"ASY0505","price":407.62,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/asy0505_etchargingdock_2.png?v=1793198125"},{"product_id":"hygiena-allersnap-protein-residue-test","title":"Hygiena AllerSnap® High-Sensitivity Protein Residue Test – 100 Tests","description":"\u003ch2\u003eHygiena AllerSnap® High-Sensitivity Protein Residue Test – 100 Tests\u003c\/h2\u003e\n\n\u003cp\u003eHygiena AllerSnap is a rapid swab test that detects protein residue left on surfaces after cleaning. Many food allergens are proteins, so it's widely used in allergen cross-contact prevention programs to check that equipment has been cleaned properly between product runs. Swab the surface, snap to release the reagent and incubate at 37 °C. The liquid stays \u003cstrong\u003egreen\u003c\/strong\u003e if the surface is clean and turns \u003cstrong\u003epurple\u003c\/strong\u003e if protein is present, with results in 30 minutes or less.\u003c\/p\u003e\n\n\u003cp\u003eAllerSnap detects as little as 3 µg of protein (per Hygiena), with no instrument needed to read the result. It needs only a 37 °C incubator. It's sold in boxes of 100 single-use tests. Hygiena AllerSnap is available in Canada from Cambridge Environmental Products with CAD pricing and Canadian purchasing support.\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003ch3 style=\"font-size:18px; line-height:1.35; margin-top:0;\"\u003eIdeal For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAllergen changeovers\u003c\/strong\u003e: verifying cleaning between allergen-containing and allergen-free production runs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFood and beverage processing\u003c\/strong\u003e: routine protein residue checks on food-contact surfaces\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAllergen control and preventive control plans\u003c\/strong\u003e that need documented cleaning verification\u003c\/li\u003e\n\u003cli\u003eSites that want a \u003cstrong\u003evisual result\u003c\/strong\u003e without a luminometer or reader\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eWhy Choose AllerSnap?\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHigh sensitivity for protein residue\u003c\/h3\u003e\n\u003cp\u003eHygiena states AllerSnap detects as little as 3 µg of protein after 30 minutes at 37 °C. That helps catch low-level residue that visual inspection misses.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eEasy-to-read colour result\u003c\/h3\u003e\n\u003cp\u003eThe reagent starts green and turns grey or purple as protein is detected. A faster, deeper colour change means more residue. No instrument is needed to read the result, so staff can interpret it on the spot.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eBroad protein detection\u003c\/h3\u003e\n\u003cp\u003eAllerSnap detects total protein rather than one specific allergen. One test can check for residue from many different products, and it works faster than allergen-specific test kits.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eAll-in-one, recyclable device\u003c\/h3\u003e\n\u003cp\u003eThe swab and reagent are in one self-contained device, with no pipetting or mixing. Hygiena describes the devices as 100% recyclable.\u003c\/p\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003col style=\"margin:0;\"\u003e\n\u003cli\u003eLet the device warm to room temperature (21–25 °C) before use.\u003c\/li\u003e\n\u003cli\u003ePull the swab out of the tube and swab a 10 × 10 cm (4 × 4 in) area in a crisscross pattern, rotating the swab.\u003c\/li\u003e\n\u003cli\u003eReturn the swab to the tube.\u003c\/li\u003e\n\u003cli\u003eBreak the Snap-Valve and squeeze the bulb twice. The liquid should turn \u003cstrong\u003egreen\u003c\/strong\u003e. If it isn't green, the test is invalid.\u003c\/li\u003e\n\u003cli\u003eShake for 5 to 10 seconds to soak the swab tip.\u003c\/li\u003e\n\u003cli\u003eIncubate at \u003cstrong\u003e37 °C for 30 minutes\u003c\/strong\u003e. You can stop early if the liquid turns purple.\u003c\/li\u003e\n\u003cli\u003eCompare the colour to the chart on the tube label and record the result.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eReading the Result\u003c\/h2\u003e\n\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eColour\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eResult\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eAction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eGreen (including green-grey)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003ePass\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSurface is clean. No further action.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eGrey\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eCaution\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSmall amount of residue. Re-clean, rinse or re-test according to your protocol.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003ePurple\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eFail\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eNot clean. Re-clean and re-test.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003cp\u003e\u003cem\u003eSteps and interpretation are from the Hygiena AllerSnap instructions for use.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eCommon Applications\u003c\/h2\u003e\n\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eApplication\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eHow AllerSnap Helps\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eAllergen changeover verification\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eConfirms protein residue has been removed before the next product run.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003ePre-operational inspection\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eChecks food-contact surfaces after cleaning and rinsing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eValidating cleaning procedures\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eShows whether a cleaning method removes protein residue consistently.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSpot checks\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eVisual result with no reader or luminometer needed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eAllerSnap® High-Sensitivity Allergen Prevention Test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eItem number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eALS-100 (Hygiena store item ASY0292)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003ePack\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e100 tests per box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eDetects\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eTotal protein residue (not allergen-specific)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e3 µg protein at 37 °C, 30 minutes (per Hygiena)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eTime to result\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e30 minutes or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eIncubation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e37 °C (incubator required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eResult\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eVisual colour change: green (pass), grey (caution), purple (fail)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eStorage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e2–25 °C; refrigerate at 2–8 °C for maximum shelf life\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eShelf life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eUse by the expiry date on the device and label\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eUse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSingle use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eHygiena\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cem\u003eSpecifications are from the Hygiena AllerSnap product sheet and instructions for use.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eSelection \u0026amp; Handling Notes\u003c\/h2\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#fff8e5;\"\u003e\n\u003cul style=\"margin:0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal protein, not a specific allergen.\u003c\/strong\u003e AllerSnap shows that protein residue is present or absent. It doesn't identify which allergen. Where your program requires confirmation of a specific allergen, use an allergen-specific test as well.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncubator required.\u003c\/strong\u003e Results are based on 30 minutes at 37 °C. Testing at lower temperatures may not reach the stated sensitivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest before disinfection.\u003c\/strong\u003e Hygiena advises testing after detergent cleaning and rinsing, but before terminal disinfection, or after the proper dwell time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSanitizer interference:\u003c\/strong\u003e peroxide-based disinfectants can cause false positives, and high concentrations of alkaline sanitizers may cause false negatives.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDon't swab visibly dirty surfaces.\u003c\/strong\u003e Heavy soil inhibits the reaction. Clean first, then verify.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle use only.\u003c\/strong\u003e See the Safety Data Sheet for handling and disposal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eProduct Documents\u003c\/h2\u003e\n\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hygiena.com\/documents\/62321\/allersnap-product-sheet-en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHygiena AllerSnap Product Sheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hygiena.com\/th\/documents\/69506\/allersnap-product-instructions-en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHygiena AllerSnap Instructions for Use (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hygiena.com\/documents\/110154\/allersnap-claim-support.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHygiena AllerSnap Claim Support (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed the Safety Data Sheet or a certificate of analysis for a specific lot? \u003ca href=\"\/pages\/contact\"\u003eContact Cambridge\u003c\/a\u003e and we'll request it from Hygiena.\u003c\/p\u003e\n\n\u003ch2\u003eCanadian Purchasing Support\u003c\/h2\u003e\n\u003cp\u003eCambridge Environmental Products is a Canadian-owned laboratory supply distributor based in Ontario and has served Canadian labs since 1993. We supply Hygiena hygiene monitoring tests with CAD pricing and shipping across Canada. We work with food and beverage processors, QA\/QC teams, sanitation managers, and research laboratories, and can help with quotes and standing orders. Browse our \u003ca href=\"\/collections\/lab-supplies\"\u003elab supplies\u003c\/a\u003e collection for more.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhat does AllerSnap detect?\u003c\/h3\u003e\n\u003cp\u003eIt detects total protein residue on surfaces. Many food allergens are proteins, so it's used to verify cleaning in allergen control programs. It doesn't identify a specific allergen.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHow sensitive is it?\u003c\/h3\u003e\n\u003cp\u003eHygiena states AllerSnap detects as little as 3 µg of protein after 30 minutes at 37 °C.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eDo I need an incubator?\u003c\/h3\u003e\n\u003cp\u003eYes. The test is incubated at 37 °C for 30 minutes. A dry block incubator set to 37 °C works.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHow do I read the result?\u003c\/h3\u003e\n\u003cp\u003eGreen means pass, grey means caution, and purple means fail. Compare the colour to the chart on the tube label.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eCan sanitizers affect the result?\u003c\/h3\u003e\n\u003cp\u003eYes. Peroxide-based disinfectants can cause false positives, and strong alkaline sanitizers may cause false negatives. Test after cleaning and rinsing, before terminal disinfection.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHow should I store it?\u003c\/h3\u003e\n\u003cp\u003eBetween 2 °C and 25 °C. For maximum shelf life, refrigerate at 2–8 °C. Let devices reach room temperature before use.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eIs AllerSnap available in Canada?\u003c\/h3\u003e\n\u003cp\u003eYes. Cambridge Environmental Products supplies Hygiena AllerSnap across Canada with CAD pricing.\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003ch3 style=\"font-size:18px; line-height:1.35; margin-top:0;\"\u003eNeed Help with Allergen Cleaning Verification?\u003c\/h3\u003e\n\u003cp\u003eTell us:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe allergens and products you run\u003c\/li\u003e\n\u003cli\u003eThe surfaces you need to verify\u003c\/li\u003e\n\u003cli\u003eWhether you have a 37 °C incubator\u003c\/li\u003e\n\u003cli\u003eHow many tests you use per month\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe'll help you choose the right Hygiena tests and set up standing orders.\u003c\/p\u003e\n\u003ca href=\"\/pages\/contact\" style=\"display:inline-block; padding:12px 18px; background:#1f4e79; color:#ffffff; text-decoration:none; border-radius:5px; font-weight:bold;\"\u003e\nContact Cambridge for Product Support\n\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Hygiena","offers":[{"title":"Default Title","offer_id":50051420815619,"sku":"ALS-100","price":456.36,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/AllerSnap.webp?v=1793205753"},{"product_id":"hygiena-spotcheck-plus-glucose-lactose-test","title":"Hygiena SpotCheck Plus Rapid Glucose \u0026 Lactose Surface Test – 100 Tests","description":"\u003ch2\u003eHygiena SpotCheck Plus Rapid Glucose \u0026amp; Lactose Surface Test – 100 Tests\u003c\/h2\u003e\n\n\u003cp\u003eHygiena SpotCheck Plus is a rapid swab test that detects glucose and lactose residue on surfaces as a quick indicator of surface hygiene. These sugars are common in food residue, so finding them after cleaning means the surface wasn't cleaned properly. Swab the surface, snap to release the reagent, and read the colour after 60 seconds. If it stays \u003cstrong\u003eclear\u003c\/strong\u003e, the surface passes. If it turns \u003cstrong\u003egreen\u003c\/strong\u003e, it's not clean.\u003c\/p\u003e\n\n\u003cp\u003eSpotCheck Plus needs no instrument and no incubator, so anyone on the sanitation team can use it at the line. It's sold in boxes of 100 single-use tests. Hygiena SpotCheck Plus is available in Canada from Cambridge Environmental Products with CAD pricing and Canadian purchasing support.\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003ch3 style=\"font-size:18px; line-height:1.35; margin-top:0;\"\u003eIdeal For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDairy processing\u003c\/strong\u003e: lactose is a direct marker of milk residue\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFood and beverage processing\u003c\/strong\u003e: sugar-containing products such as juices, bakery, confectionery and sauces\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-operational sanitation checks\u003c\/strong\u003e at the line, with no lab equipment\u003c\/li\u003e\n\u003cli\u003eSites that want a \u003cstrong\u003elow-cost, instrument-free\u003c\/strong\u003e cleaning check alongside ATP or protein testing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eWhy Choose SpotCheck Plus?\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eResults in 60 seconds\u003c\/h3\u003e\n\u003cp\u003eRead the result after 1 minute and re-clean straight away if the surface fails. Staff don't have to wait for lab results before starting production.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eNo instrument or incubator\u003c\/h3\u003e\n\u003cp\u003eThe colour change is read by eye against the chart on the tube label. There's no luminometer, reader or incubator to buy, calibrate or maintain.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eSensitive to sugar residue\u003c\/h3\u003e\n\u003cp\u003eHygiena states SpotCheck Plus detects down to 2.5 µM D-glucose and 5.0 µM lactose within 1 minute. The more sugar present, the faster and darker the colour change.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eAll-in-one device\u003c\/h3\u003e\n\u003cp\u003eThe swab and reagent are in one self-contained device, with no pipetting or mixing. Hygiena describes the devices as 100% recyclable.\u003c\/p\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003col style=\"margin:0;\"\u003e\n\u003cli\u003eLet the device warm to room temperature (20–25 °C) before use.\u003c\/li\u003e\n\u003cli\u003eTwist and pull the swab out of the tube. Swab a 10 × 10 cm (4 × 4 in) area in a crisscross pattern, pressing firmly enough to flex the shaft and rotating the swab.\u003c\/li\u003e\n\u003cli\u003eReturn the swab to the tube.\u003c\/li\u003e\n\u003cli\u003eBreak the SnapValve by bending the bulb back and forth, then squeeze the bulb twice to release all the liquid.\u003c\/li\u003e\n\u003cli\u003eShake for 5 seconds to soak the swab tip.\u003c\/li\u003e\n\u003cli\u003eWait \u003cstrong\u003e1 minute\u003c\/strong\u003e, then compare the colour to the chart on the tube label. If there's no colour change after 2 minutes, the test is negative.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eReading the Result\u003c\/h2\u003e\n\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eColour\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eResult\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eAction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eClear\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003ePass\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSurface is clean. No action needed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eLight green\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eCaution\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSmall amount of residue. Re-clean, rinse or re-test according to your protocol.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eDark green\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eFail\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eNot clean. Re-clean and re-test.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003cp\u003e\u003cem\u003eSteps and interpretation are from the Hygiena SpotCheck Plus instructions for use. Hygiena recommends running positive and negative controls as part of good laboratory practice.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eCommon Applications\u003c\/h2\u003e\n\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eApplication\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eHow SpotCheck Plus Helps\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eDairy equipment\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eLactose detection shows milk residue left after cleaning.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSugar-containing product lines\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eGlucose detection shows residue from juices, syrups, bakery and confectionery.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003ePre-operational inspection\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eA quick pass\/fail check before start-up, read at the line.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eTraining and spot checks\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eA simple visual result that helps sanitation staff see where cleaning was missed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSpotCheck Plus Glucose \u0026amp; Lactose Detection Device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eItem number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eGL100 (Hygiena store item ASY0039)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003ePack\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e100 tests per box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eDetects\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eGlucose and lactose residue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e2.5 µM D-glucose; 5.0 µM lactose (per Hygiena)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eTime to result\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eIncubation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eNone; read at room temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eResult\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eVisual colour change: clear (pass), light green (caution), dark green (fail)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eStorage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e2–8 °C for maximum shelf life; up to 4 weeks at 9–22 °C; do not freeze\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eShelf life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eUse by the expiry date on the label\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eUse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSingle use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eHygiena\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cem\u003eSpecifications are from the Hygiena SpotCheck Plus instructions for use, product sheet and Hygiena product listing.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eSelection \u0026amp; Handling Notes\u003c\/h2\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#fff8e5;\"\u003e\n\u003cul style=\"margin:0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetects glucose and lactose only.\u003c\/strong\u003e A clear result means those sugars weren't detected. It doesn't rule out other residues such as fats or proteins. For broader cleaning verification, use it alongside ATP or protein residue testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerate on receipt.\u003c\/strong\u003e Store at 2–8 °C, don't freeze, and keep at room temperature (9–22 °C) for no more than 4 weeks. Hygiena notes the product is temperature sensitive.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm before use.\u003c\/strong\u003e Let devices reach 20–25 °C before testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle use only.\u003c\/strong\u003e See the Safety Data Sheet for handling information.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eProduct Documents\u003c\/h2\u003e\n\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hygiena.com\/documents\/64056\/spotcheck-plus-product-sheet-en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHygiena SpotCheck Plus Product Sheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hygiena.com\/documents\/63291\/spotcheck-plus-instructions-en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHygiena SpotCheck Plus Instructions for Use (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed the Safety Data Sheet or a certificate of analysis for a specific lot? \u003ca href=\"\/pages\/contact\"\u003eContact Cambridge\u003c\/a\u003e and we'll request it from Hygiena.\u003c\/p\u003e\n\n\u003ch2\u003eCanadian Purchasing Support\u003c\/h2\u003e\n\u003cp\u003eCambridge Environmental Products is a Canadian-owned laboratory supply distributor based in Ontario and has served Canadian labs since 1993. We supply Hygiena hygiene monitoring tests with CAD pricing and shipping across Canada. We work with food and beverage processors, dairy plants, QA\/QC teams, sanitation managers, and research laboratories, and can help with quotes and standing orders. Browse our \u003ca href=\"\/collections\/lab-supplies\"\u003elab supplies\u003c\/a\u003e collection for more.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhat does SpotCheck Plus detect?\u003c\/h3\u003e\n\u003cp\u003eGlucose and lactose residue on surfaces. These sugars are common in food residue, so detecting them shows a surface hasn't been cleaned properly.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHow long does it take?\u003c\/h3\u003e\n\u003cp\u003e1 minute. If there's no colour change after 2 minutes, the test is negative.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eDo I need an instrument or incubator?\u003c\/h3\u003e\n\u003cp\u003eNo. The result is read by eye against the chart on the tube label, at room temperature.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHow do I read the result?\u003c\/h3\u003e\n\u003cp\u003eClear means pass, light green means caution, and dark green means fail.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eIs it good for dairy plants?\u003c\/h3\u003e\n\u003cp\u003eYes. Lactose is the main sugar in milk, so the test is a direct check for milk residue on dairy equipment.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHow should I store it?\u003c\/h3\u003e\n\u003cp\u003eRefrigerate at 2–8 °C and don't freeze. Devices can be kept at 9–22 °C for up to 4 weeks. Let them reach room temperature before use.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eIs SpotCheck Plus available in Canada?\u003c\/h3\u003e\n\u003cp\u003eYes. Cambridge Environmental Products supplies Hygiena SpotCheck Plus across Canada with CAD pricing.\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003ch3 style=\"font-size:18px; line-height:1.35; margin-top:0;\"\u003eNeed Help Choosing a Cleaning Verification Test?\u003c\/h3\u003e\n\u003cp\u003eTell us:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe products you run (dairy, sugar-based, protein-based)\u003c\/li\u003e\n\u003cli\u003eThe surfaces you need to verify\u003c\/li\u003e\n\u003cli\u003eWhether you use a luminometer or incubator\u003c\/li\u003e\n\u003cli\u003eHow many tests you use per month\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe'll help you choose the right Hygiena tests and set up standing orders.\u003c\/p\u003e\n\u003ca href=\"\/pages\/contact\" style=\"display:inline-block; padding:12px 18px; background:#1f4e79; color:#ffffff; text-decoration:none; border-radius:5px; font-weight:bold;\"\u003e\nContact Cambridge for Product Support\n\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Hygiena","offers":[{"title":"Default Title","offer_id":50051849814275,"sku":"GL100","price":379.82,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/pf-spotcheck-plus-e1614970528881.webp?v=1793207128"},{"product_id":"hygiena-zymosnap-alp-alkaline-phosphatase-test","title":"Hygiena ZymoSnap™ ALP Alkaline Phosphatase Test – Dairy Pasteurization Verification, 100 Tests","description":"\u003ch2\u003eHygiena ZymoSnap™ ALP Alkaline Phosphatase Test – Dairy Pasteurization Verification, 100 Tests\u003c\/h2\u003e\n\n\u003cp\u003eHygiena ZymoSnap ALP is a rapid test that measures alkaline phosphatase (ALP) in milk and dairy products to verify pasteurization. ALP is an enzyme naturally present in raw milk and destroyed by proper pasteurization, so a low ALP result confirms the product was heat-treated correctly. ZymoSnap uses bioluminescence and gives a quantitative result in about 5 minutes on the Hygiena EnSURE Touch or EnSURE luminometer.\u003c\/p\u003e\n\n\u003cp\u003eEach device is an all-in-one test: add 75 µL of sample, snap to release the reagent, incubate for 5 minutes at 37 °C and read. Hygiena states the method is AOAC Performance Tested Method℠ validated, and that it measures below the 350 mU\/L critical limit for ALP. It's sold in boxes of 100 single-use tests. Hygiena ZymoSnap ALP is available in Canada from Cambridge Environmental Products with CAD pricing and Canadian purchasing support.\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003ch3 style=\"font-size:18px; line-height:1.35; margin-top:0;\"\u003eIdeal For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDairy processors\u003c\/strong\u003e: verifying pasteurization of each batch at the plant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFluid milk\u003c\/strong\u003e: whole, semi-skimmed and skimmed cow's milk, and goat's milk\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCream, flavoured milks, shakes and yogurts\u003c\/strong\u003e (per Hygiena)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDairy QA\/QC and contract testing labs\u003c\/strong\u003e that want results in minutes instead of hours\u003c\/li\u003e\n\u003cli\u003eSites already using a \u003cstrong\u003eHygiena EnSURE Touch or EnSURE\u003c\/strong\u003e luminometer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eWhy Choose ZymoSnap ALP?\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003ePasteurization results in about 5 minutes\u003c\/h3\u003e\n\u003cp\u003eThe assay takes 5 minutes of incubation plus about 10 seconds to read. A problem with the pasteurizer can be caught and the product held before it leaves the plant.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eQuantitative and sensitive\u003c\/h3\u003e\n\u003cp\u003eLight output (RLU) is directly proportional to ALP activity. Hygiena states the test measures below the 350 mU\/L critical limit for ALP in cow's milk, and compares its performance to the ISO 11816 \/ IDF 155 fluorometric reference method.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eAOAC validated\u003c\/h3\u003e\n\u003cp\u003eHygiena states ZymoSnap ALP is validated under the AOAC Performance Tested Methods℠ program. The certificate is linked under Product Documents.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eSimple, all-in-one device\u003c\/h3\u003e\n\u003cp\u003eThere are no reagents to prepare. Pipette the sample into the device, activate it and incubate. Results are stored on the luminometer and can be trended in Hygiena's SureTrend software. Hygiena states throughput is more than 45 tests per hour.\u003c\/p\u003e\n\n\u003ch2\u003eWhat You Need\u003c\/h2\u003e\n\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eItem\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eZymoSnap ALP devices\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eThis product: 100 tests per box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eHygiena luminometer\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eEnSURE Touch or EnSURE (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e37 °C incubator\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eDry block incubator or water bath at 37 ±1 °C (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003ePipette and tips\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e75 µL (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003ePositive control\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eZymoSnap ALP Positive Control Kit (ZS-ALP-PC), sold separately, to set pass\/fail limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003col style=\"margin:0;\"\u003e\n\u003cli\u003eLet the device stand at room temperature (20–25 °C) for 10 minutes.\u003c\/li\u003e\n\u003cli\u003eLift the Snap-Valve bulb out of the tube and pipette \u003cstrong\u003e75 µL\u003c\/strong\u003e of sample into the tube. Replace the bulb and flick the device so all the sample reaches the bottom.\u003c\/li\u003e\n\u003cli\u003eBreak the Snap-Valve and squeeze the bulb twice to release the reagent.\u003c\/li\u003e\n\u003cli\u003eIncubate at \u003cstrong\u003e37 ±1 °C for 5 minutes\u003c\/strong\u003e. Turn on the luminometer and select the product program during incubation.\u003c\/li\u003e\n\u003cli\u003eShake for 5 seconds, insert the device into the luminometer and read. Results take about 10 seconds. Read each device only once.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003eSteps are from the Hygiena ZymoSnap ALP instructions for use. Pass\/fail RLU limits must be set for each milk type using the positive control kit, and checked monthly and with each new lot.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eCommon Applications\u003c\/h2\u003e\n\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eApplication\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eHow ZymoSnap ALP Helps\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eBatch release\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eConfirms pasteurization in minutes before product ships.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003ePasteurizer checks\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eCatches under-processing or raw milk contamination quickly.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMultiple milk types\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSeparate pass\/fail limits can be set for each fat level and product.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eRecords and trending\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eResults stored on the luminometer and in SureTrend software.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eZymoSnap™ ALP Alkaline Phosphatase Test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eItem number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eZS-ALP-100 (Hygiena store item ASY0347)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003ePack\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e100 tests per box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eMethod\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eBioluminescence; quantitative ALP activity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eSample volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e75 µL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eIncubation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e5 min ±10 s at 37 ±1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eRead time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eAbout 10 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eCritical limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMeasures below 350 mU\/L ALP (per Hygiena)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eMatrices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eCow's milk (whole, semi-skimmed, skimmed, flavoured), goat's milk, cream; Hygiena also lists yogurts and shakes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eNot suitable for\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eLong-life or ambient-stable (e.g. UHT) milk products\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eCompatible instruments\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eHygiena EnSURE Touch and EnSURE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eValidation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eAOAC Performance Tested Method℠ (per Hygiena)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eStorage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e2–8 °C, in a cool dark place; keep in the bag until use (light sensitive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eShelf life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eUse by the expiry date on the label\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eHygiena\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cem\u003eSpecifications are from the Hygiena ZymoSnap ALP instructions for use, product sheet and product page.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eSelection \u0026amp; Handling Notes\u003c\/h2\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#fff8e5;\"\u003e\n\u003cul style=\"margin:0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003ePositive control kit required.\u003c\/strong\u003e Pass\/fail RLU limits depend on milk type and fat content. Set them with the ZymoSnap Positive Control Kit, then re-check monthly and with each new lot of devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNot for UHT or ambient-stable products.\u003c\/strong\u003e Hygiena states the test isn't suitable for long-life milk.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKeep samples chilled.\u003c\/strong\u003e Reactivated phosphatase and microbial phosphatase can give high readings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl incubation closely.\u003c\/strong\u003e RLU varies with incubation temperature and time, so keep to 37 ±1 °C and 5 minutes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLight sensitive:\u003c\/strong\u003e store devices at 2–8 °C in their bag until use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegulatory use:\u003c\/strong\u003e check the method against the pasteurization verification requirements that apply to your facility.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eProduct Documents\u003c\/h2\u003e\n\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hygiena.com\/documents\/62606\/zymosnap-alp-product-sheet-en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHygiena ZymoSnap ALP Product Sheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hygiena.com\/documents\/63301\/zymosnap-alp-instructions-en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHygiena ZymoSnap ALP Instructions for Use (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hygiena.com\/documents\/66471\/zymosnap-alp-aoac.pdf\" target=\"_blank\" rel=\"noopener\"\u003eZymoSnap ALP AOAC Certificate (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hygiena.com\/documents\/68441\/validation-of-zymosnap-for-alkaline-phosphatase-alp-detection-in-dairy-products.pdf\" target=\"_blank\" rel=\"noopener\"\u003eValidation of ZymoSnap for ALP Detection in Dairy Products (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hygiena.com\/documents\/69126\/testing-high-fat-content-matrices-with-zymosnap-alp.pdf\" target=\"_blank\" rel=\"noopener\"\u003eTesting High Fat Content Matrices with ZymoSnap ALP (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hygiena.com\/documents\/68931\/zymosnap-alp-sds-en-us.pdf\" target=\"_blank\" rel=\"noopener\"\u003eZymoSnap ALP Safety Data Sheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCanadian Purchasing Support\u003c\/h2\u003e\n\u003cp\u003eCambridge Environmental Products is a Canadian-owned laboratory supply distributor based in Ontario and has served Canadian labs since 1993. We supply Hygiena ZymoSnap ALP tests with CAD pricing and shipping across Canada. We work with dairy processors, food and beverage QA\/QC labs, contract testing labs and research laboratories, and can help with quotes and standing orders. Browse our \u003ca href=\"\/collections\/lab-supplies\"\u003elab supplies\u003c\/a\u003e collection for more.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhat does ZymoSnap ALP test for?\u003c\/h3\u003e\n\u003cp\u003eAlkaline phosphatase (ALP), an enzyme in raw milk that's destroyed by proper pasteurization. A low result confirms the product was pasteurized correctly.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHow long does a test take?\u003c\/h3\u003e\n\u003cp\u003eAbout 5 minutes of incubation at 37 °C, plus about 10 seconds to read.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhat equipment do I need?\u003c\/h3\u003e\n\u003cp\u003eA Hygiena EnSURE Touch or EnSURE luminometer, a 37 °C incubator or water bath, a 75 µL pipette and the ZymoSnap Positive Control Kit.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eIs it validated?\u003c\/h3\u003e\n\u003cp\u003eHygiena states ZymoSnap ALP is AOAC Performance Tested Method℠ validated. The certificate is linked above.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eCan I test cream or flavoured milk?\u003c\/h3\u003e\n\u003cp\u003eYes. Hygiena lists cream, flavoured milks, yogurts and shakes, as well as cow's and goat's milk. It's not suitable for UHT or other ambient-stable products.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhy do I need the positive control kit?\u003c\/h3\u003e\n\u003cp\u003eRLU readings depend on milk type and fat content. The positive control (350 mU\/L) sets the pass\/fail RLU for each product you test.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eIs ZymoSnap ALP available in Canada?\u003c\/h3\u003e\n\u003cp\u003eYes. Cambridge Environmental Products supplies Hygiena ZymoSnap ALP across Canada with CAD pricing.\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003ch3 style=\"font-size:18px; line-height:1.35; margin-top:0;\"\u003eNeed Help Setting Up ALP Testing?\u003c\/h3\u003e\n\u003cp\u003eTell us:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe dairy products and fat levels you test\u003c\/li\u003e\n\u003cli\u003eWhich Hygiena luminometer you use\u003c\/li\u003e\n\u003cli\u003eWhether you have a 37 °C incubator\u003c\/li\u003e\n\u003cli\u003eHow many tests you run per week\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe'll help you set up ZymoSnap testing and standing orders.\u003c\/p\u003e\n\u003ca href=\"\/pages\/contact\" style=\"display:inline-block; padding:12px 18px; background:#1f4e79; color:#ffffff; text-decoration:none; border-radius:5px; font-weight:bold;\"\u003e\nContact Cambridge for Product Support\n\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Hygiena","offers":[{"title":"Default Title","offer_id":50052024238339,"sku":"ZS-ALP-100","price":414.7,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/ZymoSnap.webp?v=1793207781"},{"product_id":"hygiena-zymosnap-alp-positive-control-kit-350-mu-l-5-vials","title":"Hygiena ZymoSnap™ ALP Positive Control Kit – 350 mU\/L, 5 Vials","description":"\u003ch2\u003eHygiena ZymoSnap™ ALP Positive Control Kit – 350 mU\/L, 5 Vials\u003c\/h2\u003e\n\n\u003cp\u003eThe Hygiena ZymoSnap ALP Positive Control Kit contains 5 vials of alkaline phosphatase (ALP) standard at 350 mU\/L, the critical limit for pasteurization verification. You need it to set and check the pass\/fail limits for Hygiena ZymoSnap ALP tests. ZymoSnap results in RLU vary with milk type and fat content, so each product you test needs its own fail limit, set by running this control in that same milk.\u003c\/p\u003e\n\n\u003cp\u003eEach vial is reconstituted with a heat-treated negative control made from the milk you're testing, so the control matches your product. Hygiena lists expected ranges for 4%, 2% and 0.1% fat milk. The Hygiena ZymoSnap Positive Control Kit is available in Canada from Cambridge Environmental Products with CAD pricing and Canadian purchasing support.\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003ch3 style=\"font-size:18px; line-height:1.35; margin-top:0;\"\u003eIdeal For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSetting pass\/fail RLU limits\u003c\/strong\u003e for each milk type tested with ZymoSnap ALP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonthly verification\u003c\/strong\u003e of ZymoSnap ALP test performance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChecking each new lot\u003c\/strong\u003e of ZymoSnap ALP devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDairy QA\/QC labs\u003c\/strong\u003e documenting test and luminometer performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eWhy You Need It\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eSets your fail limit at 350 mU\/L\u003c\/h3\u003e\n\u003cp\u003eThe control contains ALP at 350 mU\/L. The average RLU of the positive control in a given milk becomes the fail limit for that product on your luminometer.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eMatched to your product\u003c\/h3\u003e\n\u003cp\u003eYou reconstitute each vial with a negative control made by heat-treating the same milk you test. The control then reflects the fat content and makeup of your own product.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eConfirms the system is working\u003c\/h3\u003e\n\u003cp\u003eRunning negative and positive controls when you start, monthly and with each new lot of devices confirms the tests, incubator and luminometer are all performing correctly.\u003c\/p\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003col style=\"margin:0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eMake the negative control:\u003c\/strong\u003e heat 10 mL of the milk you test at 72 °C for 10 minutes, cool quickly on ice, cover and refrigerate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest the negative control:\u003c\/strong\u003e run 3 ZymoSnap ALP tests. The average must be below 20 RLU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMake the positive control:\u003c\/strong\u003e remove the vial's seal and cap, add 1.0 mL of the matching negative control, recap and shake vigorously for 60 seconds until dissolved.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest the positive control:\u003c\/strong\u003e run 3 ZymoSnap ALP tests and check the average against the expected range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSet the limit:\u003c\/strong\u003e enter the positive control average as the fail RLU for that milk type on your luminometer.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003eSteps are from the Hygiena ZymoSnap ALP Positive Control Kit instructions. Use a separate vial and negative control for each milk type.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eExpected Positive Control Results\u003c\/h2\u003e\n\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eMilk Fat\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eMin RLU\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eMax RLU\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e4%\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e222\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e249\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e2%\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e315\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e385\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e0.1%\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e548\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e784\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003cp\u003e\u003cem\u003eAverage of 3 replicates, per Hygiena. If the average falls outside the range, repeat 3 tests from the same vial.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eZymoSnap™ ALP Positive Control Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eItem number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eZS-ALP-PC (Hygiena store item ASY0373)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eContents\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e5 vials of ALP standard, 350 mU\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eReconstitution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e1.0 mL heat-treated negative control (your own milk) per vial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eStorage (unopened)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e2–8 °C; use by the expiry date on the box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eReconstituted control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e2–8 °C, use within 7 days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eNegative control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eUse within 48 hours at 2–8 °C, or freeze at −20 °C for up to 3 weeks (single freeze-thaw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eFor use with\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eHygiena ZymoSnap ALP tests (ZS-ALP-100) on the EnSURE Touch or EnSURE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eHygiena\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cem\u003eSpecifications are from the Hygiena ZymoSnap ALP Positive Control Kit instructions and product page.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eSelection \u0026amp; Handling Notes\u003c\/h2\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#fff8e5;\"\u003e\n\u003cul style=\"margin:0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquipment not included:\u003c\/strong\u003e you'll also need ZymoSnap ALP tests, a Hygiena EnSURE Touch or EnSURE, a 72 °C water bath or incubator, a 37 °C incubator, an ice bath, and pipettes for 75 µL and 1.0 mL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOne milk type per vial.\u003c\/strong\u003e Reconstitute each vial only with negative control made from the milk type being tested.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest the negative control first.\u003c\/strong\u003e It must average below 20 RLU before you prepare the positive control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKeep samples chilled.\u003c\/strong\u003e Reactivated and microbial phosphatase can give high readings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort stability once mixed:\u003c\/strong\u003e use reconstituted controls within 7 days.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eProduct Documents\u003c\/h2\u003e\n\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hygiena.com\/documents\/63306\/zymosnap-alp-positive-control-kit-instructions-en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHygiena ZymoSnap ALP Positive Control Kit Instructions (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hygiena.com\/documents\/63301\/zymosnap-alp-instructions-en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHygiena ZymoSnap ALP Instructions for Use (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed the Safety Data Sheet or a certificate of analysis for a specific lot? \u003ca href=\"\/pages\/contact\"\u003eContact Cambridge\u003c\/a\u003e and we'll request it from Hygiena.\u003c\/p\u003e\n\n\u003ch2\u003eCanadian Purchasing Support\u003c\/h2\u003e\n\u003cp\u003eCambridge Environmental Products is a Canadian-owned laboratory supply distributor based in Ontario and has served Canadian labs since 1993. We supply Hygiena ZymoSnap ALP positive control kits with CAD pricing and shipping across Canada. We work with dairy processors, food and beverage QA\/QC labs, contract testing labs and research laboratories, and can help with quotes and standing orders. Browse our \u003ca href=\"\/collections\/lab-supplies\"\u003elab supplies\u003c\/a\u003e collection for more.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhat is the positive control kit for?\u003c\/h3\u003e\n\u003cp\u003eIt sets and checks the pass\/fail RLU limits for ZymoSnap ALP tests. Each vial contains ALP at 350 mU\/L, the critical limit for pasteurization verification.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHow many vials are in a kit?\u003c\/h3\u003e\n\u003cp\u003e5 vials. Each one is reconstituted with 1.0 mL of negative control made from one milk type.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHow often should I run controls?\u003c\/h3\u003e\n\u003cp\u003eWhen you first set up, monthly, and with each new lot of ZymoSnap ALP devices, per Hygiena.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHow long does a reconstituted vial last?\u003c\/h3\u003e\n\u003cp\u003eUp to 7 days at 2–8 °C.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eDo I need a separate vial for each milk type?\u003c\/h3\u003e\n\u003cp\u003eYes. Reconstitute each vial with negative control made from the same milk type you're setting the limit for.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eIs the kit available in Canada?\u003c\/h3\u003e\n\u003cp\u003eYes. Cambridge Environmental Products supplies the Hygiena ZymoSnap Positive Control Kit across Canada with CAD pricing.\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003ch3 style=\"font-size:18px; line-height:1.35; margin-top:0;\"\u003eNeed Help Setting Up ALP Testing?\u003c\/h3\u003e\n\u003cp\u003eTell us:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe dairy products and fat levels you test\u003c\/li\u003e\n\u003cli\u003eWhich Hygiena luminometer you use\u003c\/li\u003e\n\u003cli\u003eHow many milk types you need limits for\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe'll help you set up ZymoSnap testing and controls.\u003c\/p\u003e\n\u003ca href=\"\/pages\/contact\" style=\"display:inline-block; padding:12px 18px; background:#1f4e79; color:#ffffff; text-decoration:none; border-radius:5px; font-weight:bold;\"\u003e\nContact Cambridge for Product Support\n\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Hygiena","offers":[{"title":"Default Title","offer_id":50052076437763,"sku":null,"price":337.03,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/ZymoSnap20Control_20Kit.webp?v=1793208011"},{"product_id":"hygiena-calcheck-led-calibration-verification","title":"Hygiena CalCheck™ LED Calibration Verification Device","description":"\u003ch2\u003eHygiena CalCheck™ LED Calibration Verification Device\u003c\/h2\u003e\n\n\u003cp\u003eHygiena CalCheck is a reusable LED device for checking that your Hygiena luminometer is reading correctly. Insert it into the luminometer like a test swab and run a negative check (no light) and a positive check (a controlled green LED flash). If both readings fall within the expected ranges, the instrument is working within specification. It takes about a minute and gives your ATP program documented proof that the luminometer can be trusted.\u003c\/p\u003e\n\n\u003cp\u003eCalCheck is powered by a replaceable coin battery and can be used repeatedly, at whatever interval your quality procedures set, such as weekly or monthly. On the EnSURE Touch, results are saved automatically and sync to SureTrend. The Hygiena CalCheck is available in Canada from Cambridge Environmental Products with CAD pricing and Canadian purchasing support.\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003ch3 style=\"font-size:18px; line-height:1.35; margin-top:0;\"\u003eIdeal For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFood and beverage plants\u003c\/strong\u003e running ATP cleaning verification programs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoutine instrument checks\u003c\/strong\u003e (e.g. weekly or monthly) required by your quality system\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAudit records\u003c\/strong\u003e showing the luminometer was verified\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTroubleshooting\u003c\/strong\u003e when ATP results look unexpected\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eWhy Choose CalCheck?\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eVerifies the luminometer in about a minute\u003c\/h3\u003e\n\u003cp\u003eA negative check confirms there's no light leak or background error, and a positive check confirms the sensor reads a known light source correctly. You don't need to send the instrument away or use reagents.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eReusable\u003c\/h3\u003e\n\u003cp\u003eCalCheck uses an LED rather than chemicals, so there are no consumables to buy for each check. Only the coin battery needs replacing.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eBuilt-in status light\u003c\/h3\u003e\n\u003cp\u003eThe power button glows green when CalCheck is ready to read, and red, or not at all, when it needs a rest or a new battery.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eAutomatic records on EnSURE Touch\u003c\/h3\u003e\n\u003cp\u003eThe EnSURE Touch has a calibration app that guides you through the internal LED, negative and positive checks. It saves the results and syncs them to SureTrend when the instrument is on Wi-Fi.\u003c\/p\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eEnSURE Touch\u003c\/h3\u003e\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003col style=\"margin:0;\"\u003e\n\u003cli\u003eTurn on the instrument and open the Calibration app.\u003c\/li\u003e\n\u003cli\u003eFollow the prompts for the internal LED test and the negative test (empty chamber).\u003c\/li\u003e\n\u003cli\u003ePress the CalCheck power button. It glows green. Insert it for the positive test.\u003c\/li\u003e\n\u003cli\u003eResults are saved automatically.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eSystemSURE Plus\u003c\/h3\u003e\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003col style=\"margin:0;\"\u003e\n\u003cli\u003eOn first use, record your initial negative and positive readings as a reference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNegative test:\u003c\/strong\u003e insert CalCheck without pressing the button, close the lid and press OK.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePositive test:\u003c\/strong\u003e press the CalCheck button, close the lid and press OK within 20 seconds.\u003c\/li\u003e\n\u003cli\u003eCompare the results with the pass criteria below.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003eSteps are from the Hygiena CalCheck instructions. Wait 2 minutes between positive readings.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003ePass Criteria\u003c\/h2\u003e\n\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eTest\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eEnSURE Touch\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eSystemSURE Plus\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eInternal LED\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eAbove 500 RLU\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eNot applicable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eNegative\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e0–4 RLU\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e0–4 RLU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003ePositive\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e255–345 RLU\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e40–80 RLU, or within ±20% of your initial reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003cp\u003e\u003cem\u003ePer the Hygiena CalCheck instructions. If results are out of range, clean the CalCheck rod with alcohol on a lint-free cloth and clean the luminometer read chamber, then repeat. Contact Hygiena support if the problem continues.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eCalCheck™ LED Calibration Verification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eItem number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eCAL (Hygiena store item ASY0441)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eChecks\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eNegative (dark) and positive (LED light) verification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eCompatible with\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eHygiena luminometers; instructions cover the EnSURE Touch and SystemSURE Plus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e1 × CR1025 3 V lithium coin battery, replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eOn time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eStays on 60 seconds after the button is pressed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eStorage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e10–25 °C (50–77 °F), in original packaging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e1 year from purchase (original purchaser)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eSold as\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eEach\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eHygiena\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cem\u003eSpecifications are from the Hygiena CalCheck instructions and Hygiena product listing.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eSelection \u0026amp; Handling Notes\u003c\/h2\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#fff8e5;\"\u003e\n\u003cul style=\"margin:0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck your luminometer model.\u003c\/strong\u003e Hygiena lists CalCheck as compatible with Hygiena luminometers, and the instructions cover the EnSURE Touch and SystemSURE Plus. Contact Cambridge to confirm fit with other models.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDon't press the button in storage.\u003c\/strong\u003e It drains the battery. Repeated positive readings can also temporarily drain it, so wait 2 minutes between them.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse the correct battery.\u003c\/strong\u003e Replace only with a CR1025 3 V coin battery. Hygiena warns of a risk of explosion with the wrong type.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDon't twist or bend the device\u003c\/strong\u003e, especially the black battery housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAcclimate before use.\u003c\/strong\u003e After exposure to extreme temperatures, let CalCheck sit at 10–25 °C for 30 minutes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpiry:\u003c\/strong\u003e check the label for an expiry date and replace the device as needed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eProduct Documents\u003c\/h2\u003e\n\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hygiena.com\/documents\/63126\/calcheck-instructions-en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHygiena CalCheck Instructions (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCanadian Purchasing Support\u003c\/h2\u003e\n\u003cp\u003eCambridge Environmental Products is a Canadian-owned laboratory supply distributor based in Ontario and has served Canadian labs since 1993. We supply Hygiena ATP monitoring systems, tests and accessories with CAD pricing and shipping across Canada. We work with food and beverage processors, QA\/QC teams, sanitation managers, and research laboratories. Browse our \u003ca href=\"\/collections\/lab-supplies\"\u003elab supplies\u003c\/a\u003e collection for more.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhat does CalCheck do?\u003c\/h3\u003e\n\u003cp\u003eIt verifies that your Hygiena luminometer reads correctly, using a negative (dark) check and a positive check with a controlled LED light.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eDoes it recalibrate the luminometer?\u003c\/h3\u003e\n\u003cp\u003eNo. It verifies the instrument is reading within specification. If results are out of range after cleaning, contact Hygiena support.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhich luminometers does it work with?\u003c\/h3\u003e\n\u003cp\u003eHygiena lists it as compatible with Hygiena luminometers. The instructions give procedures and pass ranges for the EnSURE Touch and SystemSURE Plus.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHow often should I use it?\u003c\/h3\u003e\n\u003cp\u003eAt the interval your quality procedures set, such as weekly or monthly.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhat battery does it use?\u003c\/h3\u003e\n\u003cp\u003eOne CR1025 3 V lithium coin battery. A red light or no light means it needs replacing.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eIs CalCheck available in Canada?\u003c\/h3\u003e\n\u003cp\u003eYes. Cambridge Environmental Products supplies Hygiena CalCheck across Canada with CAD pricing.\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003ch3 style=\"font-size:18px; line-height:1.35; margin-top:0;\"\u003eNeed Help with Your Hygiena System?\u003c\/h3\u003e\n\u003cp\u003eTell us:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWhich Hygiena luminometer you use\u003c\/li\u003e\n\u003cli\u003eHow often your quality system requires instrument checks\u003c\/li\u003e\n\u003cli\u003eWhich ATP tests you use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe'll help you find the right accessories and tests.\u003c\/p\u003e\n\u003ca href=\"\/pages\/contact\" style=\"display:inline-block; padding:12px 18px; background:#1f4e79; color:#ffffff; text-decoration:none; border-radius:5px; font-weight:bold;\"\u003e\nContact Cambridge for Product Support\n\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Hygiena","offers":[{"title":"Default Title","offer_id":50052177264899,"sku":"CAL","price":884.75,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/pf-calcheck.webp?v=1793208330"},{"product_id":"hygiena-microsnap-total-viable-count-test","title":"Hygiena MicroSnap™ Total – Rapid Total Viable Count Test, Step 1 \u0026 Step 2","description":"\u003ch2\u003eHygiena MicroSnap™ Total – Rapid Total Viable Count Test, Step 1 \u0026amp; Step 2\u003c\/h2\u003e\n\n\u003cp\u003eHygiena MicroSnap Total is a rapid test for total viable count (TVC), also called aerobic plate count, in food, liquids and on surfaces. It gives a CFU count in about 7 hours, so you have results within the same shift instead of waiting 2 to 3 days for plates. The test uses a Step 1 enrichment device and a Step 2 bioluminescent detection device, read on the Hygiena EnSURE Touch.\u003c\/p\u003e\n\n\u003cp\u003eHygiena states the MicroSnap Total system with the EnSURE Touch holds AOAC Research Institute Performance Tested Methods℠ certification. Step 1 and Step 2 devices are each sold in boxes of 100. Hygiena MicroSnap Total is available in Canada from Cambridge Environmental Products with CAD pricing and Canadian purchasing support.\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003ch3 style=\"font-size:18px; line-height:1.35; margin-top:0;\"\u003eIdeal For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFood and beverage QA\/QC\u003c\/strong\u003e: total viable counts on raw materials and finished product\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental monitoring\u003c\/strong\u003e: bacterial load on surfaces after cleaning\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDairy, meat, poultry and bakery\u003c\/strong\u003e producers who want same-day counts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShelf-life and process checks\u003c\/strong\u003e where waiting for plate counts slows decisions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eWhy Choose MicroSnap Total?\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eSame-shift results\u003c\/h3\u003e\n\u003cp\u003eResults are ready in about 7 hours of enrichment plus a 10-second read. Product can be held or released, or a surface re-cleaned, the same day instead of waiting 1 to 3 days for plate counts.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eCounts read automatically\u003c\/h3\u003e\n\u003cp\u003eThe Hygiena EnSURE Touch reads the detection device and converts the light signal to CFU, so there are no colonies to count by hand. Results are stored and can be trended in SureTrend.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eOne system for surfaces, liquids and solids\u003c\/h3\u003e\n\u003cp\u003eSwab a 10 × 10 cm surface directly with the enrichment device, or add 1 mL of a liquid or 10% food homogenate. Serial dilutions extend the counting range for heavily contaminated samples.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eAOAC validated\u003c\/h3\u003e\n\u003cp\u003eHygiena states MicroSnap Total with the EnSURE Touch holds AOAC RI Performance Tested Methods℠ certification (#031501) for aerobic heterotrophic bacteria. Validated matrices include ground beef, raw chicken, raw milk, cream cake and packaged lettuce.\u003c\/p\u003e\n\n\u003ch2\u003eHow MicroSnap Works: Two Steps\u003c\/h2\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003cp style=\"margin-top:0;\"\u003e\u003cstrong\u003eEach test uses one Step 1 device and one Step 2 device.\u003c\/strong\u003e Both are sold separately in boxes of 100, so for 100 tests, order one box of each.\u003c\/p\u003e\n\u003cul style=\"margin-bottom:0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 1 – Enrichment:\u003c\/strong\u003e a pre-moistened swab device with growth medium. Collect the sample, activate and incubate at 30 °C for 7 hours.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 2 – Detection:\u003c\/strong\u003e transfer 0.1 mL (2 drops) of the enriched sample into the detection device, activate and read on the EnSURE Touch.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eAvailable Devices\u003c\/h2\u003e\n\n\u003cp\u003eChoose the \u003cstrong\u003eDevice\u003c\/strong\u003e in the selector.\u003c\/p\u003e\n\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eCode\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eDevice\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eStep\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003ePack\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMS1-TOTAL\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMicroSnap Total Enrichment Device\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eStep 1 – Enrichment\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMS2-TOTAL\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMicroSnap Total Detection Device\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eStep 2 – Detection\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003col style=\"margin:0;\"\u003e\n\u003cli\u003eLet devices reach room temperature (20–25 °C) before use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample:\u003c\/strong\u003e swab a 10 × 10 cm (4 × 4 in) area in a crisscross pattern, or add 1 mL of liquid or 10% w\/v food homogenate to the enrichment device.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnrich:\u003c\/strong\u003e break the Snap-Valve, squeeze to release the medium, shake gently and incubate at 30 °C for 7 hours.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetect:\u003c\/strong\u003e transfer 0.1 mL (2 drops) of enriched sample to the detection device, break the Snap-Valve and squeeze to release the reagent, and shake gently for 2 seconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRead:\u003c\/strong\u003e insert the detection device into the EnSURE Touch. Results display in CFU in about 10 seconds.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003eSteps are summarized from the Hygiena MicroSnap Total instructions for use. Follow the full instructions for timing, dilutions and controls.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eCounting Range\u003c\/h2\u003e\n\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eSample\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eApproximate Range\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSurface\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e10 to 1,000,000 CFU\/swab\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eLiquid (1 mL)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e10 to 500,000 CFU\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSolid (10% w\/v suspension)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e100 to 50,000 CFU\/g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003cp\u003e\u003cem\u003eAfter 7 hours, per Hygiena. The limit of detection is roughly 10–100 CFU\/mL. 1% and 0.1% dilutions extend the range to about 500,000 and 5,000,000 CFU.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eWhat You Need\u003c\/h2\u003e\n\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eItem\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMicroSnap Step 1 and Step 2 devices\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eFrom this page, one of each per test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eHygiena EnSURE Touch luminometer\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eRequired to read results (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eDry block incubator\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSet to 30 °C (32 °C for milk in broth vials) (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eFor food samples\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSample bags, homogenizer, sterile diluent and 1 mL pipette (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eTest\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eTotal viable count (aerobic bacteria)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eCodes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMS1-TOTAL (Step 1), MS2-TOTAL (Step 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003ePack\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e100 devices per box, each step\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eEnrichment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e30 ± 0.5 °C, 7 h ± 10 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eDetection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eBioluminescence, read on EnSURE Touch in about 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eTime to result\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eAbout 7 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eSamples\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSurfaces, liquids, solid food homogenates\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eValidation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eAOAC RI PTM℠ #031501, with EnSURE Touch (per Hygiena)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eStorage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e2–8 °C, protected from prolonged light\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eHygiena\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cem\u003eSpecifications are from the Hygiena MicroSnap Total instructions for use and product sheet.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eSelection \u0026amp; Handling Notes\u003c\/h2\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#fff8e5;\"\u003e\n\u003cul style=\"margin:0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder both steps.\u003c\/strong\u003e Step 1 and Step 2 devices are sold separately and both are needed for each test.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerate on receipt.\u003c\/strong\u003e Store devices at 2–8 °C, out of prolonged light, and use by the expiry date.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm samples and devices first.\u003c\/strong\u003e Cold samples under-detect. Bring samples and devices to 20–25 °C before testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKeep timing tight.\u003c\/strong\u003e Incubation time and temperature affect counts, so use a calibrated dry block incubator.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSome matrices need broth vials.\u003c\/strong\u003e Opaque samples such as undiluted milk can give low counts, and leafy greens can give high counts. Hygiena recommends its Enhanced Nutrient Broth for difficult samples, which is outside the AOAC certification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispose safely.\u003c\/strong\u003e Used devices may be biohazardous. Autoclave, or soak unsealed devices in 20% bleach for 1 hour, before disposal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFor food and environmental testing only.\u003c\/strong\u003e Not for diagnostic use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eProduct Documents\u003c\/h2\u003e\n\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hygiena.com\/documents\/63426\/microsnap-total-enrichment--detection-device-instructions-en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHygiena MicroSnap Total Instructions for Use (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed the Safety Data Sheet or a certificate of analysis for a specific lot? \u003ca href=\"\/pages\/contact\"\u003eContact Cambridge\u003c\/a\u003e and we'll request it from Hygiena.\u003c\/p\u003e\n\n\u003ch2\u003eCanadian Purchasing Support\u003c\/h2\u003e\n\u003cp\u003eCambridge Environmental Products is a Canadian-owned laboratory supply distributor based in Ontario and has served Canadian labs since 1993. We supply Hygiena MicroSnap tests with CAD pricing and shipping across Canada. We work with food and beverage processors, QA\/QC labs, contract testing labs and research laboratories, and can help with quotes and standing orders. Browse our \u003ca href=\"\/collections\/lab-supplies\"\u003elab supplies\u003c\/a\u003e collection for more.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhat does MicroSnap Total measure?\u003c\/h3\u003e\n\u003cp\u003eTotal viable count (aerobic bacteria), reported in CFU per swab, mL or g.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHow long does it take?\u003c\/h3\u003e\n\u003cp\u003eAbout 7 hours of enrichment at 30 °C, then about 10 seconds to read.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eIs it validated?\u003c\/h3\u003e\n\u003cp\u003eHygiena states MicroSnap Total with the EnSURE Touch holds AOAC RI Performance Tested Methods℠ certification #031501.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eDo I need to buy both Step 1 and Step 2?\u003c\/h3\u003e\n\u003cp\u003eYes. Each test uses one enrichment device (Step 1) and one detection device (Step 2). They're sold separately in boxes of 100.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhat equipment do I need?\u003c\/h3\u003e\n\u003cp\u003eA Hygiena EnSURE Touch luminometer and a dry block incubator. Food samples also need sample bags, a homogenizer, diluent and a 1 mL pipette.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHow should I store MicroSnap devices?\u003c\/h3\u003e\n\u003cp\u003eRefrigerate at 2–8 °C, keep them out of prolonged light, and let them reach room temperature before use.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eAre MicroSnap tests available in Canada?\u003c\/h3\u003e\n\u003cp\u003eYes. Cambridge Environmental Products supplies Hygiena MicroSnap tests across Canada with CAD pricing.\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003ch3 style=\"font-size:18px; line-height:1.35; margin-top:0;\"\u003eNeed Help Setting Up MicroSnap Testing?\u003c\/h3\u003e\n\u003cp\u003eTell us:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWhat you test (surfaces, liquids, solid foods)\u003c\/li\u003e\n\u003cli\u003eWhich organisms your program monitors\u003c\/li\u003e\n\u003cli\u003eWhether you have an EnSURE Touch and dry block incubator\u003c\/li\u003e\n\u003cli\u003eHow many tests you run per week\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe'll help you choose the right MicroSnap tests and set up standing orders.\u003c\/p\u003e\n\u003ca href=\"\/pages\/contact\" style=\"display:inline-block; padding:12px 18px; background:#1f4e79; color:#ffffff; text-decoration:none; border-radius:5px; font-weight:bold;\"\u003e\nContact Cambridge for Product Support\n\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Hygiena","offers":[{"title":"Step 1","offer_id":50052813783299,"sku":"MS1-TOTAL","price":241.01,"currency_code":"CAD","in_stock":true},{"title":"Step 2","offer_id":50052813816067,"sku":"MS2-TOTAL","price":294.78,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/asy0306_microsnaptotaldetection_1.png?v=1793210955"},{"product_id":"hygiena-microsnap-eb-enterobacteriaceae-test","title":"Hygiena MicroSnap™ EB – Rapid Enterobacteriaceae Test, Step 1 \u0026 Step 2","description":"\u003ch2\u003eHygiena MicroSnap™ EB – Rapid Enterobacteriaceae Test, Step 1 \u0026amp; Step 2\u003c\/h2\u003e\n\n\u003cp\u003eHygiena MicroSnap EB is a rapid test that detects and counts Enterobacteriaceae (EB) in food, liquids and on surfaces. EB are a widely used hygiene indicator group in food production. The test gives a CFU count in 6 or 7 hours, or a presence\/absence result after 8 hours, so you have results within the same shift. It uses a Step 1 enrichment device and a Step 2 detection device, read on the Hygiena EnSURE Touch.\u003c\/p\u003e\n\n\u003cp\u003eStep 1 and Step 2 devices are each sold in boxes of 100. Hygiena MicroSnap EB is available in Canada from Cambridge Environmental Products with CAD pricing and Canadian purchasing support.\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003ch3 style=\"font-size:18px; line-height:1.35; margin-top:0;\"\u003eIdeal For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFood processing\u003c\/strong\u003e: Enterobacteriaceae as a hygiene and process indicator\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental monitoring\u003c\/strong\u003e: EB on food-contact and non-food-contact surfaces\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDairy, infant formula, meat and ready-to-eat\u003c\/strong\u003e producers monitoring EB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSame-day decisions\u003c\/strong\u003e on product release or re-cleaning\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eWhy Choose MicroSnap EB?\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eSame-shift results\u003c\/h3\u003e\n\u003cp\u003eCounts are ready after 6 or 7 hours of enrichment, or presence\/absence after 8 hours, plus a 10-second read. Product can be held or released, or a surface re-cleaned, the same day instead of waiting 1 to 3 days for plate counts.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eCounts read automatically\u003c\/h3\u003e\n\u003cp\u003eThe Hygiena EnSURE Touch reads the detection device and converts the light signal to CFU, so there are no colonies to count by hand. Results are stored and can be trended in SureTrend.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eOne system for surfaces, liquids and solids\u003c\/h3\u003e\n\u003cp\u003eSwab a 10 × 10 cm surface directly with the enrichment device, or add 1 mL of a liquid or 10% food homogenate. Serial dilutions extend the counting range for heavily contaminated samples.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eCount or presence\/absence\u003c\/h3\u003e\n\u003cp\u003eRun 6 or 7 hours for a count, or 8 hours or more for a presence\/absence result. The EnSURE Touch reports 0 as absence, 1 as caution and 2 or more as presence.\u003c\/p\u003e\n\n\u003ch2\u003eHow MicroSnap Works: Two Steps\u003c\/h2\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003cp style=\"margin-top:0;\"\u003e\u003cstrong\u003eEach test uses one Step 1 device and one Step 2 device.\u003c\/strong\u003e Both are sold separately in boxes of 100, so for 100 tests, order one box of each.\u003c\/p\u003e\n\u003cul style=\"margin-bottom:0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 1 – Enrichment:\u003c\/strong\u003e a pre-moistened swab device with growth medium. Collect the sample, activate and incubate at 37 °C for 6 or 7 hours (count) or 8–24 hours (presence\/absence).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 2 – Detection:\u003c\/strong\u003e transfer 0.1 mL (2 drops) of the enriched sample into the detection device, activate and read on the EnSURE Touch.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eAvailable Devices\u003c\/h2\u003e\n\n\u003cp\u003eChoose the \u003cstrong\u003eDevice\u003c\/strong\u003e in the selector.\u003c\/p\u003e\n\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eCode\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eDevice\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eStep\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003ePack\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMS1-EB\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMicroSnap EB Enrichment Device\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eStep 1 – Enrichment\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMS2-EB\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMicroSnap EB Detection Device\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eStep 2 – Detection\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003col style=\"margin:0;\"\u003e\n\u003cli\u003eLet devices reach room temperature (20–25 °C) before use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample:\u003c\/strong\u003e swab a 10 × 10 cm (4 × 4 in) area in a crisscross pattern, or add 1 mL of liquid or 10% w\/v food homogenate to the enrichment device.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnrich:\u003c\/strong\u003e break the Snap-Valve, squeeze to release the medium, shake gently and incubate at 37 °C for 6 or 7 hours (count) or 8–24 hours (presence\/absence).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetect:\u003c\/strong\u003e transfer 0.1 mL (2 drops) of enriched sample to the detection device, break the Snap-Valve and squeeze to release the reagent, mix gently and read straight away.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRead:\u003c\/strong\u003e insert the detection device into the EnSURE Touch. Results display in CFU in about 10 seconds.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003eSteps are summarized from the Hygiena MicroSnap EB instructions for use. Follow the full instructions for timing, dilutions and controls.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eCounting Range\u003c\/h2\u003e\n\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eSample\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eApproximate Range\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSurface\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eFrom 10 CFU\/swab\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eLiquid (1 mL)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eFrom 10 CFU\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSolid (10% w\/v suspension)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eFrom 100 CFU\/g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003ePresence\/absence (8 h)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e0 = absence, 1 = caution, ≥2 = presence\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003cp\u003e\u003cem\u003eUpper limits depend on enrichment time (6 or 7 hours). See the Hygiena instructions for the full ranges, and dilute samples that exceed them.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eWhat You Need\u003c\/h2\u003e\n\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eItem\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMicroSnap Step 1 and Step 2 devices\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eFrom this page, one of each per test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eHygiena EnSURE Touch luminometer\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eRequired to read results (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eDry block incubator\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSet to 37 °C (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eFor food samples\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSample bags, homogenizer, sterile diluent and 1 mL pipette (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eTest\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eEnterobacteriaceae (EB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eCodes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMS1-EB (Step 1), MS2-EB (Step 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003ePack\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e100 devices per box, each step\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eEnrichment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e37 ± 0.5 °C; 6 or 7 h (count), 8–24 h (presence\/absence)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eDetection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eRead on EnSURE Touch in about 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eTime to result\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e6–8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eSamples\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSurfaces, liquids, solid food homogenates\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eStorage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e2–8 °C, protected from prolonged light\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eHygiena\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cem\u003eSpecifications are from the Hygiena MicroSnap EB instructions for use and product sheet.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eSelection \u0026amp; Handling Notes\u003c\/h2\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#fff8e5;\"\u003e\n\u003cul style=\"margin:0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder both steps.\u003c\/strong\u003e Step 1 and Step 2 devices are sold separately and both are needed for each test.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerate on receipt.\u003c\/strong\u003e Store devices at 2–8 °C, out of prolonged light, and use by the expiry date.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm samples and devices first.\u003c\/strong\u003e Cold samples under-detect. Bring samples and devices to 20–25 °C before testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKeep timing tight.\u003c\/strong\u003e Incubation time and temperature affect counts, so use a calibrated dry block incubator.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNot a Salmonella test.\u003c\/strong\u003e Hygiena notes EB counts can't substitute for Salmonella testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSome matrices need broth vials.\u003c\/strong\u003e Thick, dark or opaque samples can give low counts, and leafy greens can give high counts. Hygiena recommends its Enhanced EB Broth for difficult samples.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispose safely.\u003c\/strong\u003e Used devices may be biohazardous. Autoclave, or soak unsealed devices in 20% bleach for 1 hour, before disposal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFor food and environmental testing only.\u003c\/strong\u003e Not for diagnostic use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eProduct Documents\u003c\/h2\u003e\n\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hygiena.com\/documents\/63421\/microsnap-eb-enrichment--detection-device-instructions-en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHygiena MicroSnap EB Instructions for Use (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/hygiena.com\/documents\/62556\/microsnap-eb-product-sheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHygiena MicroSnap EB Product Sheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed the Safety Data Sheet or a certificate of analysis for a specific lot? \u003ca href=\"\/pages\/contact\"\u003eContact Cambridge\u003c\/a\u003e and we'll request it from Hygiena.\u003c\/p\u003e\n\n\u003ch2\u003eCanadian Purchasing Support\u003c\/h2\u003e\n\u003cp\u003eCambridge Environmental Products is a Canadian-owned laboratory supply distributor based in Ontario and has served Canadian labs since 1993. We supply Hygiena MicroSnap tests with CAD pricing and shipping across Canada. We work with food and beverage processors, QA\/QC labs, contract testing labs and research laboratories, and can help with quotes and standing orders. Browse our \u003ca href=\"\/collections\/lab-supplies\"\u003elab supplies\u003c\/a\u003e collection for more.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhat does MicroSnap EB detect?\u003c\/h3\u003e\n\u003cp\u003eEnterobacteriaceae, a family of bacteria used as a hygiene and process indicator in food production.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHow long does it take?\u003c\/h3\u003e\n\u003cp\u003e6 or 7 hours for a count, or 8 hours or more for presence\/absence, plus about 10 seconds to read.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eCan it replace Salmonella testing?\u003c\/h3\u003e\n\u003cp\u003eNo. Hygiena notes Enterobacteriaceae counts can't substitute for Salmonella testing.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eDo I need to buy both Step 1 and Step 2?\u003c\/h3\u003e\n\u003cp\u003eYes. Each test uses one enrichment device (Step 1) and one detection device (Step 2). They're sold separately in boxes of 100.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhat equipment do I need?\u003c\/h3\u003e\n\u003cp\u003eA Hygiena EnSURE Touch luminometer and a dry block incubator. Food samples also need sample bags, a homogenizer, diluent and a 1 mL pipette.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHow should I store MicroSnap devices?\u003c\/h3\u003e\n\u003cp\u003eRefrigerate at 2–8 °C, keep them out of prolonged light, and let them reach room temperature before use.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eAre MicroSnap tests available in Canada?\u003c\/h3\u003e\n\u003cp\u003eYes. Cambridge Environmental Products supplies Hygiena MicroSnap tests across Canada with CAD pricing.\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003ch3 style=\"font-size:18px; line-height:1.35; margin-top:0;\"\u003eNeed Help Setting Up MicroSnap Testing?\u003c\/h3\u003e\n\u003cp\u003eTell us:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWhat you test (surfaces, liquids, solid foods)\u003c\/li\u003e\n\u003cli\u003eWhich organisms your program monitors\u003c\/li\u003e\n\u003cli\u003eWhether you have an EnSURE Touch and dry block incubator\u003c\/li\u003e\n\u003cli\u003eHow many tests you run per week\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe'll help you choose the right MicroSnap tests and set up standing orders.\u003c\/p\u003e\n\u003ca href=\"\/pages\/contact\" style=\"display:inline-block; padding:12px 18px; background:#1f4e79; color:#ffffff; text-decoration:none; border-radius:5px; font-weight:bold;\"\u003e\nContact Cambridge for Product Support\n\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Hygiena","offers":[{"title":"Step 1","offer_id":50053069996291,"sku":"MS1-EB","price":283.39,"currency_code":"CAD","in_stock":true},{"title":"Step 2","offer_id":50053070029059,"sku":"MS2-EB","price":456.76,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/asy0361_microsnapebdetectionswab_1.png?v=1793212167"},{"product_id":"hygiena-microsnap-coliform-e-coli-test","title":"Hygiena MicroSnap™ Coliform \u0026 E. coli – Rapid Test, Step 1 \u0026 Step 2","description":"\u003ch2\u003eHygiena MicroSnap™ Coliform \u0026amp; E. coli – Rapid Test, Step 1 \u0026amp; Step 2\u003c\/h2\u003e\n\n\u003cp\u003eHygiena MicroSnap Coliform and MicroSnap E. coli are rapid tests that detect and count coliforms and E. coli in food, liquids and on surfaces. Both use the same Step 1 enrichment device, then a coliform or E. coli Step 2 detection device, read on the Hygiena EnSURE Touch. Counts are ready in about 6 hours, or presence\/absence after 8 hours, so you have results within the same shift.\u003c\/p\u003e\n\n\u003cp\u003eHygiena states the MicroSnap Coliform and E. coli methods hold AOAC Research Institute Performance Tested Methods℠ certification. Each device is sold in boxes of 100. Hygiena MicroSnap Coliform and E. coli tests are available in Canada from Cambridge Environmental Products with CAD pricing and Canadian purchasing support.\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003ch3 style=\"font-size:18px; line-height:1.35; margin-top:0;\"\u003eIdeal For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFood and beverage QA\/QC\u003c\/strong\u003e: coliform and E. coli counts on raw materials and finished product\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWater and beverage\u003c\/strong\u003e producers checking for faecal indicators\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDairy, meat and produce\u003c\/strong\u003e processors who want same-day results\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental monitoring\u003c\/strong\u003e of surfaces for coliforms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eWhy Choose MicroSnap Coliform \u0026amp; E. coli?\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eSame-shift results\u003c\/h3\u003e\n\u003cp\u003eCounts are ready after about 6 hours of enrichment, or presence\/absence after 8 hours, plus a 10-minute detection step and a 10-second read. Product can be held or released, or a surface re-cleaned, the same day instead of waiting 1 to 3 days for plate counts.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eCounts read automatically\u003c\/h3\u003e\n\u003cp\u003eThe Hygiena EnSURE Touch reads the detection device and converts the light signal to CFU, so there are no colonies to count by hand. Results are stored and can be trended in SureTrend.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eOne system for surfaces, liquids and solids\u003c\/h3\u003e\n\u003cp\u003eSwab a 10 × 10 cm surface directly with the enrichment device, or add 1 mL of a liquid or 10% food homogenate. Serial dilutions extend the counting range for heavily contaminated samples.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eOne enrichment, two tests\u003c\/h3\u003e\n\u003cp\u003eThe same Step 1 device (MS1-CEC) enriches for both coliforms and E. coli. From one enriched sample you can run the coliform test, the E. coli test, or both.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eAOAC validated\u003c\/h3\u003e\n\u003cp\u003eHygiena states the methods hold AOAC RI Performance Tested Methods℠ certification (#071302) within the validated incubation times.\u003c\/p\u003e\n\n\u003ch2\u003eHow MicroSnap Works: Two Steps\u003c\/h2\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003cp style=\"margin-top:0;\"\u003e\u003cstrong\u003eEach test uses one Step 1 device and one Step 2 device.\u003c\/strong\u003e Both are sold separately in boxes of 100, so for 100 tests, order one box of each.\u003c\/p\u003e\n\u003cul style=\"margin-bottom:0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 1 – Enrichment:\u003c\/strong\u003e a pre-moistened swab device with growth medium. Collect the sample, activate and incubate at 37 °C for 6 hours (count) or 8–24 hours (presence\/absence).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 2 – Detection:\u003c\/strong\u003e transfer 0.1 mL (2 drops) of the enriched sample into the detection device, activate, incubate at 37 °C for 10 minutes, and read on the EnSURE Touch.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eAvailable Devices\u003c\/h2\u003e\n\n\u003cp\u003eChoose the \u003cstrong\u003eDevice\u003c\/strong\u003e in the selector.\u003c\/p\u003e\n\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eCode\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eDevice\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eStep\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003ePack\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMS1-CEC\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMicroSnap Coliform \u0026amp; E. coli Enrichment Device\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eStep 1 – Enrichment\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMS2-COLIFORM\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMicroSnap Coliform Detection Device\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eStep 2 – Coliform Detection\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMS2-ECOLI\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMicroSnap E. coli Detection Device\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eStep 2 – E. coli Detection\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eWhich Devices Should I Order?\u003c\/h2\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003cul style=\"margin:0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eColiform testing:\u003c\/strong\u003e MS1-CEC (Step 1) + MS2-COLIFORM (Step 2).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eE. coli testing:\u003c\/strong\u003e MS1-CEC (Step 1) + MS2-ECOLI (Step 2).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBoth from one sample:\u003c\/strong\u003e one MS1-CEC + one MS2-COLIFORM + one MS2-ECOLI.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003col style=\"margin:0;\"\u003e\n\u003cli\u003eLet devices reach room temperature (20–25 °C) before use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample:\u003c\/strong\u003e swab a 10 × 10 cm (4 × 4 in) area in a crisscross pattern, or add 1 mL of liquid or 10% w\/v food homogenate to the enrichment device.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnrich:\u003c\/strong\u003e break the Snap-Valve, squeeze to release the medium, shake gently and incubate at 37 °C for 6 hours (count) or 8–24 hours (presence\/absence).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetect:\u003c\/strong\u003e transfer 0.1 mL (2 drops) of enriched sample to the detection device, break the Snap-Valve and squeeze to release the reagent, then incubate at 37 °C for 10 minutes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRead:\u003c\/strong\u003e insert the detection device into the EnSURE Touch. Results display in CFU in about 10 seconds.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003eSteps are summarized from the Hygiena MicroSnap Coliform \u0026amp; E. coli instructions for use. Follow the full instructions for timing, dilutions and controls.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eCounting Range\u003c\/h2\u003e\n\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eSample\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eApproximate Range\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSurface\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e10 to 10,000 CFU\/swab\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eLiquid (1 mL)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e10 to 10,000 CFU\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSolid (10% w\/v suspension)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e100 to 10,000 CFU\/g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003ePresence\/absence (8 h)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e0 = absence, 1 = caution, ≥2 = presence\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003cp\u003e\u003cem\u003eAfter 6 hours, per Hygiena. 1% and 0.1% dilutions extend the range to about 100,000 and 1,000,000 CFU.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eWhat You Need\u003c\/h2\u003e\n\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eItem\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMicroSnap Step 1 and Step 2 devices\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eFrom this page, one of each per test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eHygiena EnSURE Touch luminometer\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eRequired to read results (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eDry block incubator\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSet to 37 °C (enrichment and detection) (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eFor food samples\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSample bags, homogenizer, sterile diluent and 1 mL pipette (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eTests\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eColiforms; E. coli\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eCodes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMS1-CEC (Step 1); MS2-COLIFORM and MS2-ECOLI (Step 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003ePack\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e100 devices per box, each code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eEnrichment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e37 ± 0.5 °C; 6 h (count), 8–24 h (presence\/absence)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eDetection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e10 min at 37 °C, then read on EnSURE Touch in about 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eTime to result\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eAbout 6–8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eSamples\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSurfaces, liquids, solid food homogenates\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eValidation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eAOAC RI PTM℠ #071302 (per Hygiena)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eStorage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e2–8 °C, protected from prolonged light\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eHygiena\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cem\u003eSpecifications are from the Hygiena MicroSnap Coliform \u0026amp; E. coli instructions for use and product sheet.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eSelection \u0026amp; Handling Notes\u003c\/h2\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#fff8e5;\"\u003e\n\u003cul style=\"margin:0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder both steps.\u003c\/strong\u003e Step 1 and Step 2 devices are sold separately and both are needed for each test.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerate on receipt.\u003c\/strong\u003e Store devices at 2–8 °C, out of prolonged light, and use by the expiry date.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm samples and devices first.\u003c\/strong\u003e Cold samples under-detect. Bring samples and devices to 20–25 °C before testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKeep timing tight.\u003c\/strong\u003e Incubation time and temperature affect counts, so use a calibrated dry block incubator.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKnown limitations:\u003c\/strong\u003e Hygiena notes \u003cem\u003eHafnia alvei\u003c\/em\u003e isn't detected, \u003cem\u003eShigella sonnei\u003c\/em\u003e can't be distinguished from E. coli, and E. coli O157:H7 is detected by the coliform test but not the E. coli test. Hygiena recommends confirming E. coli results where needed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSome matrices need broth vials.\u003c\/strong\u003e Undiluted milk or chocolate can give low counts, and leafy greens or fermented dairy can give high counts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispose safely.\u003c\/strong\u003e Used devices may be biohazardous. Autoclave, or soak unsealed devices in 20% bleach for 1 hour, before disposal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFor food and environmental testing only.\u003c\/strong\u003e Not for diagnostic use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eProduct Documents\u003c\/h2\u003e\n\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hygiena.com\/documents\/63416\/microsnap-coliform--e-coli-enrichment--detection-device-instructions-en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHygiena MicroSnap Coliform \u0026amp; E. coli Instructions for Use (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hygiena.com\/fr\/documents\/87341\/microsnap-coliform-product-sheet-en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHygiena MicroSnap Coliform Product Sheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hygiena.com\/de\/documents\/87346\/microsnap-e-coli-product-sheet-en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHygiena MicroSnap E. coli Product Sheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed the Safety Data Sheet or a certificate of analysis for a specific lot? \u003ca href=\"\/pages\/contact\"\u003eContact Cambridge\u003c\/a\u003e and we'll request it from Hygiena.\u003c\/p\u003e\n\n\u003ch2\u003eCanadian Purchasing Support\u003c\/h2\u003e\n\u003cp\u003eCambridge Environmental Products is a Canadian-owned laboratory supply distributor based in Ontario and has served Canadian labs since 1993. We supply Hygiena MicroSnap tests with CAD pricing and shipping across Canada. We work with food and beverage processors, QA\/QC labs, contract testing labs and research laboratories, and can help with quotes and standing orders. Browse our \u003ca href=\"\/collections\/lab-supplies\"\u003elab supplies\u003c\/a\u003e collection for more.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhich devices do I need?\u003c\/h3\u003e\n\u003cp\u003eFor coliforms: MS1-CEC plus MS2-COLIFORM. For E. coli: MS1-CEC plus MS2-ECOLI. To run both from one sample, add one of each Step 2 device.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHow long does it take?\u003c\/h3\u003e\n\u003cp\u003eAbout 6 hours of enrichment for a count (8 hours for presence\/absence), then 10 minutes at 37 °C and about 10 seconds to read.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eDoes the E. coli test detect O157:H7?\u003c\/h3\u003e\n\u003cp\u003eNo. Hygiena notes E. coli O157:H7 is detected by the coliform test but not the E. coli test.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eIs it validated?\u003c\/h3\u003e\n\u003cp\u003eHygiena states the methods hold AOAC RI Performance Tested Methods℠ certification #071302.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eDo I need to buy both Step 1 and Step 2?\u003c\/h3\u003e\n\u003cp\u003eYes. Each test uses one enrichment device (Step 1) and one detection device (Step 2). They're sold separately in boxes of 100.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhat equipment do I need?\u003c\/h3\u003e\n\u003cp\u003eA Hygiena EnSURE Touch luminometer and a dry block incubator. Food samples also need sample bags, a homogenizer, diluent and a 1 mL pipette.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHow should I store MicroSnap devices?\u003c\/h3\u003e\n\u003cp\u003eRefrigerate at 2–8 °C, keep them out of prolonged light, and let them reach room temperature before use.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eAre MicroSnap tests available in Canada?\u003c\/h3\u003e\n\u003cp\u003eYes. Cambridge Environmental Products supplies Hygiena MicroSnap tests across Canada with CAD pricing.\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003ch3 style=\"font-size:18px; line-height:1.35; margin-top:0;\"\u003eNeed Help Setting Up MicroSnap Testing?\u003c\/h3\u003e\n\u003cp\u003eTell us:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWhat you test (surfaces, liquids, solid foods)\u003c\/li\u003e\n\u003cli\u003eWhich organisms your program monitors\u003c\/li\u003e\n\u003cli\u003eWhether you have an EnSURE Touch and dry block incubator\u003c\/li\u003e\n\u003cli\u003eHow many tests you run per week\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe'll help you choose the right MicroSnap tests and set up standing orders.\u003c\/p\u003e\n\u003ca href=\"\/pages\/contact\" style=\"display:inline-block; padding:12px 18px; background:#1f4e79; color:#ffffff; text-decoration:none; border-radius:5px; font-weight:bold;\"\u003e\nContact Cambridge for Product Support\n\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Hygiena","offers":[{"title":"Step 1","offer_id":50053343052035,"sku":"MS1-CEC","price":283.46,"currency_code":"CAD","in_stock":true},{"title":"Step 2 – Coliform Detection","offer_id":50053343084803,"sku":"MS2-COLIFORM","price":645.17,"currency_code":"CAD","in_stock":true},{"title":"Step 2 – E. coli Detection","offer_id":50053355929859,"sku":"MS2-ECOLI","price":679.7,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/asy0284_microsnape.coli-1coliformenrichmentswab_1.png?v=1793213889"},{"product_id":"hygiena-insite-listeria-swab-test","title":"Hygiena InSite® Listeria – Environmental Listeria spp. Swab Test, 50 Tests","description":"\u003ch2\u003eHygiena InSite® Listeria – Environmental Listeria spp. Swab Test, 50 Tests\u003c\/h2\u003e\n\n\u003cp\u003eHygiena InSite Listeria is an all-in-one swab test for screening food processing environments for \u003cem\u003eListeria\u003c\/em\u003e species. Swab the surface, snap to release the selective broth, and incubate at 37 °C. If \u003cem\u003eListeria\u003c\/em\u003e is present, the yellow medium turns \u003cstrong\u003egrey or black\u003c\/strong\u003e, with presumptive positives visible from 24 hours and negatives confirmed at 48 hours. There's no media prep, no plating and no lab equipment beyond a 37 °C incubator.\u003c\/p\u003e\n\n\u003cp\u003eHygiena states InSite Listeria detects fewer than 10 CFU of \u003cem\u003eListeria\u003c\/em\u003e spp. and holds AOAC Research Institute Performance Tested Methods℠ certification. It's sold in boxes of 50 tests. Hygiena InSite Listeria is available in Canada from Cambridge Environmental Products with CAD pricing and Canadian purchasing support.\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003ch3 style=\"font-size:18px; line-height:1.35; margin-top:0;\"\u003eIdeal For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFood processing plants\u003c\/strong\u003e: routine \u003cem\u003eListeria\u003c\/em\u003e environmental monitoring after cleaning\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReady-to-eat, dairy, meat and produce\u003c\/strong\u003e facilities with Listeria control programs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIn-house screening\u003c\/strong\u003e before sending presumptive positives for confirmation\u003c\/li\u003e\n\u003cli\u003eSites that want \u003cstrong\u003elow-cost, visual\u003c\/strong\u003e results without a full micro lab\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eWhy Choose InSite Listeria?\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eAll-in-one device\u003c\/h3\u003e\n\u003cp\u003eThe pre-moistened foam swab, selective broth and colour indicator are in one sealed device, so there's no media to prepare or transfer and less risk of cross-contamination.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eEasy visual result\u003c\/h3\u003e\n\u003cp\u003e\u003cem\u003eListeria\u003c\/em\u003e enzymes turn the yellow broth grey or black. Staff read the result by eye, with no reader or luminometer.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eSensitive screening\u003c\/h3\u003e\n\u003cp\u003eHygiena states the test detects fewer than 10 CFU of \u003cem\u003eListeria\u003c\/em\u003e spp., and heat-injured \u003cem\u003eL. monocytogenes\u003c\/em\u003e at 10–50 CFU even with high levels of competing organisms. The large foam tip helps collect more of the sample.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eAOAC validated\u003c\/h3\u003e\n\u003cp\u003eHygiena states InSite Listeria holds AOAC RI Performance Tested Methods℠ certification (#121902) for \u003cem\u003eListeria\u003c\/em\u003e spp. on plastic, ceramic and stainless steel surfaces.\u003c\/p\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003col style=\"margin:0;\"\u003e\n\u003cli\u003eSwab a 10 × 10 cm (4 × 4 in) area in a crisscross pattern, rotating the swab.\u003c\/li\u003e\n\u003cli\u003eReturn the swab to the tube and seal it.\u003c\/li\u003e\n\u003cli\u003eBreak the SnapValve and squeeze the bulb 3–4 times to release the broth.\u003c\/li\u003e\n\u003cli\u003eMassage the bottom of the tube and shake for 3 seconds.\u003c\/li\u003e\n\u003cli\u003eIncubate at \u003cstrong\u003e37 ± 1 °C for 24–48 hours\u003c\/strong\u003e, then read the colour.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003eSteps are summarized from the Hygiena InSite Listeria instructions for use. Follow the full instructions.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eReading the Result\u003c\/h2\u003e\n\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eResult\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eWhat You See\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eNegative\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eNo colour change (yellow)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\n\u003cem\u003eListeria\u003c\/em\u003e spp. not detected (final at 48 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003ePresumptive positive\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eGrey or black on the swab or in the broth\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003ePresumptive \u003cem\u003eListeria\u003c\/em\u003e spp.; confirm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003cp\u003e\u003cem\u003eA negative can only be recorded after 48 hours. Presumptive positives can be confirmed with PCR or a reference method such as Health Canada, FDA BAM, USDA MLG or ISO.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eWhat You Need\u003c\/h2\u003e\n\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eItem\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eInSite Listeria devices\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eThis product: 50 tests per box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eDry block incubator\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e37 ± 1 °C (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSealing tape or film\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSelf-sealing tape, plastic wrap or paraffin film to seal the device (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eInSite® Listeria\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eItem number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eILC050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003ePack\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e50 tests per box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eDetects\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\n\u003cem\u003eListeria\u003c\/em\u003e spp. (presumptive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\u0026lt;10 CFU \u003cem\u003eListeria\u003c\/em\u003e spp. (per Hygiena)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eIncubation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e37 ± 1 °C, 24–48 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eResult\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eVisual: yellow (negative), grey\/black (presumptive positive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eValidation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eAOAC RI PTM℠ #121902 (per Hygiena)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eStorage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e2–8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eHygiena\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cem\u003eSpecifications are from the Hygiena InSite Listeria instructions for use and product sheet.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eSelection \u0026amp; Handling Notes\u003c\/h2\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#fff8e5;\"\u003e\n\u003cul style=\"margin:0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eResults are presumptive.\u003c\/strong\u003e Confirm positives with PCR or a reference method.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWait 48 hours for negatives.\u003c\/strong\u003e Don't record a negative before 48 hours of incubation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListeria-like organisms\u003c\/strong\u003e such as \u003cem\u003eEnterococcus\u003c\/em\u003e can also cause blackening. Expect more presumptives from heavily contaminated sites such as floors and drains.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerate on receipt.\u003c\/strong\u003e Store at 2–8 °C and use by the expiry date.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrained staff only.\u003c\/strong\u003e These tests can grow pathogens. Hygiena advises that pregnant women and immunocompromised people should not be near testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispose safely.\u003c\/strong\u003e Treat used devices as biohazards. Autoclave, incinerate, or soak unsealed devices in 20% bleach for 1 hour before disposal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eProduct Documents\u003c\/h2\u003e\n\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hygiena.com\/documents\/64241\/insite-listeria-instructions-en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHygiena InSite Listeria Instructions for Use (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hygiena.com\/documents\/64311\/insite-listeria-product-sheet-en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHygiena InSite Listeria Product Sheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed the Safety Data Sheet or a certificate of analysis for a specific lot? \u003ca href=\"\/pages\/contact\"\u003eContact Cambridge\u003c\/a\u003e and we'll request it from Hygiena.\u003c\/p\u003e\n\n\u003ch2\u003eCanadian Purchasing Support\u003c\/h2\u003e\n\u003cp\u003eCambridge Environmental Products is a Canadian-owned laboratory supply distributor based in Ontario and has served Canadian labs since 1993. We supply Hygiena InSite environmental tests with CAD pricing and shipping across Canada. We work with food and beverage processors, QA\/QC labs, sanitation managers and research laboratories, and can help with quotes and standing orders. Browse our \u003ca href=\"\/collections\/lab-supplies\"\u003elab supplies\u003c\/a\u003e collection for more.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhat does InSite Listeria detect?\u003c\/h3\u003e\n\u003cp\u003e\u003cem\u003eListeria\u003c\/em\u003e species on environmental surfaces. Results are presumptive and should be confirmed.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHow long does it take?\u003c\/h3\u003e\n\u003cp\u003ePresumptive positives can show from 24 hours. Negatives are recorded at 48 hours.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eDoes it identify L. monocytogenes?\u003c\/h3\u003e\n\u003cp\u003eNo. It detects \u003cem\u003eListeria\u003c\/em\u003e spp. For a test that also flags \u003cem\u003eL. monocytogenes\u003c\/em\u003e, see Hygiena InSite L. mono Glo.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhat equipment do I need?\u003c\/h3\u003e\n\u003cp\u003eA dry block incubator at 37 °C and tape or film to seal the device.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHow should I store it?\u003c\/h3\u003e\n\u003cp\u003eRefrigerate at 2–8 °C and use by the expiry date.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eIs InSite Listeria available in Canada?\u003c\/h3\u003e\n\u003cp\u003eYes. Cambridge Environmental Products supplies Hygiena InSite Listeria across Canada with CAD pricing.\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003ch3 style=\"font-size:18px; line-height:1.35; margin-top:0;\"\u003eNeed Help Setting Up Environmental Monitoring?\u003c\/h3\u003e\n\u003cp\u003eTell us:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWhich organisms your program monitors\u003c\/li\u003e\n\u003cli\u003eThe surfaces and zones you test\u003c\/li\u003e\n\u003cli\u003eWhether you have a 37 °C dry block incubator\u003c\/li\u003e\n\u003cli\u003eHow many swabs you run per week\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe'll help you choose the right Hygiena tests and set up standing orders.\u003c\/p\u003e\n\u003ca href=\"\/pages\/contact\" style=\"display:inline-block; padding:12px 18px; background:#1f4e79; color:#ffffff; text-decoration:none; border-radius:5px; font-weight:bold;\"\u003e\nContact Cambridge for Product Support\n\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Hygiena","offers":[{"title":"Default Title","offer_id":50053413011715,"sku":"ILC050","price":705.83,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/asy0438_insitelisteriaswabback_4.png?v=1793214625"},{"product_id":"hygiena-insite-l-mono-glo-swab-test","title":"Hygiena InSite® L. mono Glo – Listeria spp. \u0026 L. monocytogenes Swab Test, 50 Tests","description":"\u003ch2\u003eHygiena InSite® L. mono Glo – Listeria spp. \u0026amp; L. monocytogenes Swab Test, 50 Tests\u003c\/h2\u003e\n\n\u003cp\u003eHygiena InSite L. mono Glo is an all-in-one environmental swab test that screens for both \u003cem\u003eListeria\u003c\/em\u003e species and \u003cem\u003eListeria monocytogenes\u003c\/em\u003e in one device. After incubation at 37 °C, a \u003cstrong\u003egrey or black\u003c\/strong\u003e colour shows presumptive \u003cem\u003eListeria\u003c\/em\u003e spp. Then a \u003cstrong\u003egreen glow\u003c\/strong\u003e under a longwave UV lamp shows presumptive \u003cem\u003eL. monocytogenes\u003c\/em\u003e. Presumptive positives are visible from 24 hours and negatives are confirmed at 48 hours.\u003c\/p\u003e\n\n\u003cp\u003eHygiena states the test detects fewer than 10 CFU of \u003cem\u003eListeria\u003c\/em\u003e spp. and \u003cem\u003eL. monocytogenes\u003c\/em\u003e, and holds AOAC Research Institute Performance Tested Methods℠ certification. It's sold in boxes of 50 tests. Hygiena InSite L. mono Glo is available in Canada from Cambridge Environmental Products with CAD pricing and Canadian purchasing support.\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003ch3 style=\"font-size:18px; line-height:1.35; margin-top:0;\"\u003eIdeal For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReady-to-eat, dairy, meat and seafood\u003c\/strong\u003e plants where \u003cem\u003eL. monocytogenes\u003c\/em\u003e is the key concern\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental monitoring programs\u003c\/strong\u003e that want to separate \u003cem\u003eL. mono\u003c\/em\u003e from other \u003cem\u003eListeria\u003c\/em\u003e species\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrioritizing investigations\u003c\/strong\u003e by flagging presumptive \u003cem\u003eL. mono\u003c\/em\u003e sites first\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIn-house screening\u003c\/strong\u003e before sending samples for confirmation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eWhy Choose InSite L. mono Glo?\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eTwo results from one swab\u003c\/h3\u003e\n\u003cp\u003eColour change screens for \u003cem\u003eListeria\u003c\/em\u003e spp., and UV fluorescence flags presumptive \u003cem\u003eL. monocytogenes\u003c\/em\u003e in the same device. You don't need a second test or a transfer step.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eAll-in-one device\u003c\/h3\u003e\n\u003cp\u003eThe pre-moistened foam swab, selective broth and indicators are in one sealed device. Hygiena states the broth includes a neutralizer to reduce sanitizer interference.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eSensitive screening\u003c\/h3\u003e\n\u003cp\u003eHygiena states the test detects fewer than 10 CFU of \u003cem\u003eListeria\u003c\/em\u003e spp. and of \u003cem\u003eL. monocytogenes\u003c\/em\u003e.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eAOAC validated\u003c\/h3\u003e\n\u003cp\u003eHygiena states InSite L. mono Glo holds AOAC RI Performance Tested Methods℠ certification (#061802) for \u003cem\u003eL. monocytogenes\u003c\/em\u003e and six other \u003cem\u003eListeria\u003c\/em\u003e species on plastic, ceramic and stainless steel surfaces. The medium can also be used as a primary enrichment for Hygiena BAX® System PCR.\u003c\/p\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003col style=\"margin:0;\"\u003e\n\u003cli\u003eSwab a 10 × 10 cm (4 × 4 in) area in a crisscross pattern, rotating the swab.\u003c\/li\u003e\n\u003cli\u003eReturn the swab to the tube, close the device and seal the joint with tape or film.\u003c\/li\u003e\n\u003cli\u003eBreak the SnapValve and squeeze the bulb 3–4 times to release the broth.\u003c\/li\u003e\n\u003cli\u003eMassage the bottom of the tube and shake for 3 seconds.\u003c\/li\u003e\n\u003cli\u003eIncubate at \u003cstrong\u003e37 ± 1 °C for 24–48 hours\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eIf the broth has turned grey or black, shine a \u003cstrong\u003elongwave UV lamp (360–400 nm)\u003c\/strong\u003e into the side of the tube bottom and look for green fluorescence. Wear UV safety glasses.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003eSteps are summarized from the Hygiena InSite L. mono Glo instructions for use. Follow the full instructions.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eReading the Result\u003c\/h2\u003e\n\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eResult\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eWhat You See\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eNegative\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eNo colour change (amber\/yellow)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\n\u003cem\u003eListeria\u003c\/em\u003e spp. not detected (final at 48 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003ePresumptive \u003cem\u003eListeria\u003c\/em\u003e spp.\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eGrey or black, no green glow under UV\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003ePresumptive \u003cem\u003eListeria\u003c\/em\u003e spp.; confirm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003ePresumptive \u003cem\u003eL. monocytogenes\u003c\/em\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eGrey or black, with green glow under UV\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003ePresumptive \u003cem\u003eL. mono\u003c\/em\u003e; confirm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003cp\u003e\u003cem\u003eDon't apply UV if the broth stays amber or yellow. A negative can only be recorded after 48 hours. Confirm presumptives with PCR, ELISA, lateral flow or a reference method such as Health Canada, FDA BAM, USDA MLG or ISO.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eWhat You Need\u003c\/h2\u003e\n\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eItem\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eInSite L. mono Glo devices\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eThis product: 50 tests per box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eDry block incubator\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e37 ± 1 °C (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eLongwave UV lamp\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e360–400 nm, with UV safety glasses (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSealing tape or film\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSelf-sealing tape, plastic wrap or paraffin film (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eInSite® L. mono Glo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eItem number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eILMG050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003ePack\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e50 tests per box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eDetects\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\n\u003cem\u003eListeria\u003c\/em\u003e spp. and \u003cem\u003eL. monocytogenes\u003c\/em\u003e (presumptive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\u0026lt;10 CFU (per Hygiena)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eIncubation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e37 ± 1 °C, 24–48 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eResult\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eVisual colour change (\u003cem\u003eListeria\u003c\/em\u003e spp.); green fluorescence under 360–400 nm UV (\u003cem\u003eL. mono\u003c\/em\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eValidation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eAOAC RI PTM℠ #061802 (per Hygiena)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eStorage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e2–8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eHygiena\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cem\u003eSpecifications are from the Hygiena InSite L. mono Glo instructions for use and product sheet.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eSelection \u0026amp; Handling Notes\u003c\/h2\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#fff8e5;\"\u003e\n\u003cul style=\"margin:0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eUV lamp required.\u003c\/strong\u003e You need a longwave (360–400 nm) UV lamp and UV safety glasses to read the \u003cem\u003eL. mono\u003c\/em\u003e result. UV light is an eye and skin hazard.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResults are presumptive.\u003c\/strong\u003e Confirm positives with PCR or a reference method.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWait 48 hours for negatives.\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListeria-like organisms\u003c\/strong\u003e such as \u003cem\u003eEnterococcus\u003c\/em\u003e can also cause blackening. Expect more presumptives from floors and drains.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerate on receipt.\u003c\/strong\u003e Store at 2–8 °C and use by the expiry date.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrained staff only.\u003c\/strong\u003e These tests can grow pathogens. Hygiena advises that pregnant women and immunocompromised people should not be near testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispose safely.\u003c\/strong\u003e Treat used devices as biohazards. Autoclave, incinerate, or soak unsealed devices in 20% bleach for 1 hour before disposal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eProduct Documents\u003c\/h2\u003e\n\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hygiena.com\/documents\/63271\/insite-l-monocytogenes-glo-instructions-en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHygiena InSite L. mono Glo Instructions for Use (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hygiena.com\/documents\/64306\/insite-l-monocytogenes-glo-product-sheet-en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHygiena InSite L. mono Glo Product Sheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed the Safety Data Sheet or a certificate of analysis for a specific lot? \u003ca href=\"\/pages\/contact\"\u003eContact Cambridge\u003c\/a\u003e and we'll request it from Hygiena.\u003c\/p\u003e\n\n\u003ch2\u003eCanadian Purchasing Support\u003c\/h2\u003e\n\u003cp\u003eCambridge Environmental Products is a Canadian-owned laboratory supply distributor based in Ontario and has served Canadian labs since 1993. We supply Hygiena InSite environmental tests with CAD pricing and shipping across Canada. We work with food and beverage processors, QA\/QC labs, sanitation managers and research laboratories, and can help with quotes and standing orders. Browse our \u003ca href=\"\/collections\/lab-supplies\"\u003elab supplies\u003c\/a\u003e collection for more.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhat does InSite L. mono Glo detect?\u003c\/h3\u003e\n\u003cp\u003e\u003cem\u003eListeria\u003c\/em\u003e species by colour change, and presumptive \u003cem\u003eL. monocytogenes\u003c\/em\u003e by green fluorescence under UV, from the same swab.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHow is it different from InSite Listeria?\u003c\/h3\u003e\n\u003cp\u003eInSite Listeria detects \u003cem\u003eListeria\u003c\/em\u003e spp. only. L. mono Glo adds a UV fluorescence check that flags presumptive \u003cem\u003eL. monocytogenes\u003c\/em\u003e.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eDo I need a UV lamp?\u003c\/h3\u003e\n\u003cp\u003eYes. A longwave UV lamp (360–400 nm) and UV safety glasses are needed to read the \u003cem\u003eL. mono\u003c\/em\u003e result. They're not included.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHow long does it take?\u003c\/h3\u003e\n\u003cp\u003ePresumptive positives can show from 24 hours. Negatives are recorded at 48 hours.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHow should I store it?\u003c\/h3\u003e\n\u003cp\u003eRefrigerate at 2–8 °C and use by the expiry date.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eIs InSite L. mono Glo available in Canada?\u003c\/h3\u003e\n\u003cp\u003eYes. Cambridge Environmental Products supplies Hygiena InSite L. mono Glo across Canada with CAD pricing.\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003ch3 style=\"font-size:18px; line-height:1.35; margin-top:0;\"\u003eNeed Help Setting Up Environmental Monitoring?\u003c\/h3\u003e\n\u003cp\u003eTell us:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWhich organisms your program monitors\u003c\/li\u003e\n\u003cli\u003eThe surfaces and zones you test\u003c\/li\u003e\n\u003cli\u003eWhether you have a 37 °C dry block incubator\u003c\/li\u003e\n\u003cli\u003eHow many swabs you run per week\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe'll help you choose the right Hygiena tests and set up standing orders.\u003c\/p\u003e\n\u003ca href=\"\/pages\/contact\" style=\"display:inline-block; padding:12px 18px; background:#1f4e79; color:#ffffff; text-decoration:none; border-radius:5px; font-weight:bold;\"\u003e\nContact Cambridge for Product Support\n\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Hygiena","offers":[{"title":"Default Title","offer_id":50053436342531,"sku":"ILMG050","price":705.83,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/asy0433_insitel.monoglo_1_53adfbb2-67f0-44ae-a4a7-b23fa5b44d7a.png?v=1793214918"},{"product_id":"hygiena-insite-salmonella-swab-test","title":"Hygiena InSite® Salmonella – Environmental Salmonella Swab Test, 50 Tests","description":"\u003ch2\u003eHygiena InSite® Salmonella – Environmental Salmonella Swab Test, 50 Tests\u003c\/h2\u003e\n\n\u003cp\u003eHygiena InSite Salmonella is an all-in-one swab test for screening food processing environments for \u003cem\u003eSalmonella\u003c\/em\u003e. Swab the surface, pre-enrich in the device, then snap to release the selective medium and incubate at 37 °C. If \u003cem\u003eSalmonella\u003c\/em\u003e is present, the medium changes from \u003cstrong\u003epurple to bright yellow\u003c\/strong\u003e. Presumptive positives are visible from 24 hours and negatives are confirmed at 48 hours, with no media prep or transfers.\u003c\/p\u003e\n\n\u003cp\u003eHygiena states InSite Salmonella holds AOAC Research Institute Performance Tested Methods℠ certification for stainless steel, plastic, rubber, ceramic and sealed concrete. It's sold in boxes of 50 tests. Hygiena InSite Salmonella is available in Canada from Cambridge Environmental Products with CAD pricing and Canadian purchasing support.\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003ch3 style=\"font-size:18px; line-height:1.35; margin-top:0;\"\u003eIdeal For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFood processing plants\u003c\/strong\u003e: \u003cem\u003eSalmonella\u003c\/em\u003e environmental monitoring after cleaning\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-moisture foods\u003c\/strong\u003e: spices, nuts, flour, pet food, confectionery and dry ingredients\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoultry, meat and egg\u003c\/strong\u003e facilities with Salmonella control programs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIn-house screening\u003c\/strong\u003e before sending presumptive positives for confirmation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eWhy Choose InSite Salmonella?\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eAll-in-one device\u003c\/h3\u003e\n\u003cp\u003eThe pre-moistened foam swab, selective medium and pH indicator are in one sealed device. Pre-enrichment and selective enrichment both happen in the same tube, with no transfers.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eEasy visual result\u003c\/h3\u003e\n\u003cp\u003eThe medium changes from purple to bright yellow when \u003cem\u003eSalmonella\u003c\/em\u003e is present. Staff read it by eye against the colour chart on the label.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eValidated on common plant surfaces\u003c\/h3\u003e\n\u003cp\u003eHygiena states InSite Salmonella holds AOAC RI Performance Tested Methods℠ certification (#022302) on stainless steel, plastic, rubber, ceramic and sealed concrete.\u003c\/p\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003col style=\"margin:0;\"\u003e\n\u003cli\u003eSwab the surface in a crisscross pattern: 30 × 30 cm or 10 × 10 cm for stainless steel, 10 × 10 cm for other surfaces.\u003c\/li\u003e\n\u003cli\u003eReturn the swab to the tube \u003cstrong\u003ewithout activating\u003c\/strong\u003e the device.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-enrich\u003c\/strong\u003e at 37 ± 1 °C for 6 hours.\u003c\/li\u003e\n\u003cli\u003eBreak the SnapValve, squeeze the bulb to release the medium, massage the tube bottom and shake for 3 seconds.\u003c\/li\u003e\n\u003cli\u003eIncubate at \u003cstrong\u003e37 ± 1 °C for a further 18–42 hours\u003c\/strong\u003e, then read the colour of the medium.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003eSteps are summarized from the Hygiena InSite Salmonella instructions for use. Follow the full instructions.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eReading the Result\u003c\/h2\u003e\n\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eResult\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eWhat You See\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eNegative\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMedium stays purple\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\n\u003cem\u003eSalmonella\u003c\/em\u003e not detected (final at 48 hours total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003ePresumptive positive\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMedium turns bright yellow\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003ePresumptive \u003cem\u003eSalmonella\u003c\/em\u003e; confirm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003cp\u003e\u003cem\u003eRead the medium, not the swab. A negative can only be recorded after 48 hours in total. Confirm presumptives by streaking onto selective Salmonella agar or with another recognized confirmation method.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eWhat You Need\u003c\/h2\u003e\n\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eItem\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eInSite Salmonella devices\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eThis product: 50 tests per box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eDry block incubator\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e37 ± 1 °C (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eInSite® Salmonella\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eItem number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eIS050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003ePack\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e50 tests per box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eDetects\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\n\u003cem\u003eSalmonella enterica\u003c\/em\u003e (presumptive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eIncubation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e6 h pre-enrichment, then 18–42 h, all at 37 ± 1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eResult\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eVisual: purple (negative), bright yellow (presumptive positive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eValidated surfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eStainless steel, plastic, rubber, ceramic, sealed concrete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eValidation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eAOAC RI PTM℠ #022302 (per Hygiena)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eStorage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e2–8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eHygiena\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cem\u003eSpecifications are from the Hygiena InSite Salmonella instructions for use and product sheet.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eSelection \u0026amp; Handling Notes\u003c\/h2\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#fff8e5;\"\u003e\n\u003cul style=\"margin:0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eDon't skip or extend pre-enrichment.\u003c\/strong\u003e Skipping the 6-hour pre-enrichment increases false negatives, and extending it increases false positives.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResults are presumptive.\u003c\/strong\u003e Some \u003cem\u003eCitrobacter\u003c\/em\u003e, \u003cem\u003eE. coli\u003c\/em\u003e and \u003cem\u003eRaoultella\u003c\/em\u003e strains, and acidic residues such as sanitizers, can turn the medium yellow. Confirm positives.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWait 48 hours for negatives.\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerate on receipt.\u003c\/strong\u003e Store at 2–8 °C and use by the expiry date.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrained staff only.\u003c\/strong\u003e These tests can grow pathogens. Hygiena advises that pregnant women and immunocompromised people should not be near testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispose safely.\u003c\/strong\u003e Treat used devices as biohazards. Autoclave, incinerate, or soak unsealed devices in 20% bleach for 1 hour before disposal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eProduct Documents\u003c\/h2\u003e\n\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hygiena.com\/documents\/63281\/insite-salmonella-instructions-en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHygiena InSite Salmonella Instructions for Use (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hygiena.com\/documents\/64156\/insite-salmonella-aoac.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInSite Salmonella AOAC Certificate (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed the Safety Data Sheet or a certificate of analysis for a specific lot? \u003ca href=\"\/pages\/contact\"\u003eContact Cambridge\u003c\/a\u003e and we'll request it from Hygiena.\u003c\/p\u003e\n\n\u003ch2\u003eCanadian Purchasing Support\u003c\/h2\u003e\n\u003cp\u003eCambridge Environmental Products is a Canadian-owned laboratory supply distributor based in Ontario and has served Canadian labs since 1993. We supply Hygiena InSite environmental tests with CAD pricing and shipping across Canada. We work with food and beverage processors, QA\/QC labs, sanitation managers and research laboratories, and can help with quotes and standing orders. Browse our \u003ca href=\"\/collections\/lab-supplies\"\u003elab supplies\u003c\/a\u003e collection for more.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhat does InSite Salmonella detect?\u003c\/h3\u003e\n\u003cp\u003e\u003cem\u003eSalmonella\u003c\/em\u003e on environmental surfaces after cleaning. Results are presumptive and should be confirmed.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHow long does it take?\u003c\/h3\u003e\n\u003cp\u003e6 hours of pre-enrichment plus 18–42 hours of incubation. Presumptive positives can show from 24 hours in total, and negatives are recorded at 48 hours.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhat does a positive look like?\u003c\/h3\u003e\n\u003cp\u003eThe medium changes from purple to bright yellow. Read the medium, not the swab.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eCan sanitizers affect the result?\u003c\/h3\u003e\n\u003cp\u003eYes. Acidic residues such as some sanitizers can cause a false yellow colour change. Test after cleaning and rinsing.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHow should I store it?\u003c\/h3\u003e\n\u003cp\u003eRefrigerate at 2–8 °C and use by the expiry date.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eIs InSite Salmonella available in Canada?\u003c\/h3\u003e\n\u003cp\u003eYes. Cambridge Environmental Products supplies Hygiena InSite Salmonella across Canada with CAD pricing.\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003ch3 style=\"font-size:18px; line-height:1.35; margin-top:0;\"\u003eNeed Help Setting Up Environmental Monitoring?\u003c\/h3\u003e\n\u003cp\u003eTell us:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWhich organisms your program monitors\u003c\/li\u003e\n\u003cli\u003eThe surfaces and zones you test\u003c\/li\u003e\n\u003cli\u003eWhether you have a 37 °C dry block incubator\u003c\/li\u003e\n\u003cli\u003eHow many swabs you run per week\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe'll help you choose the right Hygiena tests and set up standing orders.\u003c\/p\u003e\n\u003ca href=\"\/pages\/contact\" style=\"display:inline-block; padding:12px 18px; background:#1f4e79; color:#ffffff; text-decoration:none; border-radius:5px; font-weight:bold;\"\u003e\nContact Cambridge for Product Support\n\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Hygiena","offers":[{"title":"Default Title","offer_id":50053454430467,"sku":"IS050","price":700.54,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/asy0515_insitesalmonellaswab50_1.png?v=1793215048"},{"product_id":"hygiena-medicheck-protein-residue-test","title":"Hygiena MediCheck™ High-Sensitivity Protein Residue Test for Healthcare – 100 Tests","description":"\u003ch2\u003eHygiena MediCheck™ High-Sensitivity Protein Residue Test for Healthcare – 100 Tests\u003c\/h2\u003e\n\n\u003cp\u003eHygiena MediCheck is a rapid swab test that detects protein residue left on surfaces after cleaning. Hygiena designed it for healthcare settings such as sterile processing departments and dental practices, to check that surgical and dental instruments and washer-disinfector surfaces have been cleaned properly before disinfection or sterilization. Swab the surface, snap to release the reagent and incubate at 37 °C. The liquid stays \u003cstrong\u003egreen\u003c\/strong\u003e if the surface is clean and turns \u003cstrong\u003epurple\u003c\/strong\u003e if protein is present, with results in 5 to 30 minutes.\u003c\/p\u003e\n\n\u003cp\u003eMediCheck detects as little as 3 µg of protein (per Hygiena), with no instrument needed to read the result. It needs only a 37 °C incubator. It's sold in boxes of 100 single-use tests. Hygiena MediCheck is available in Canada from Cambridge Environmental Products with CAD pricing and Canadian purchasing support.\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003ch3 style=\"font-size:18px; line-height:1.35; margin-top:0;\"\u003eIdeal For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSterile processing departments\u003c\/strong\u003e: verifying instrument cleaning before sterilization\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDental practices\u003c\/strong\u003e: checking that instruments are clean after washing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWasher-disinfector checks\u003c\/strong\u003e: verifying surfaces and cleaning performance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInfection prevention programs\u003c\/strong\u003e that need documented cleaning verification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eWhy Choose MediCheck?\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eConfirms cleaning before sterilization\u003c\/h3\u003e\n\u003cp\u003eProtein residue such as blood and tissue left on instruments can shield microorganisms and stop disinfection and sterilization from working properly. MediCheck shows whether cleaning removed that residue, so problems can be fixed before the instrument moves on.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHigh sensitivity\u003c\/h3\u003e\n\u003cp\u003eHygiena states MediCheck detects about 3 µg of protein after 30 minutes at 37 °C. Heavier soil shows sooner: about 10 µg from 5 minutes and 5 µg from 10 minutes.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eEasy-to-read colour result\u003c\/h3\u003e\n\u003cp\u003eGreen means pass, grey means caution and purple means fail. Staff read the result by eye against the chart on the tube label, with no reader or luminometer.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eAll-in-one, recyclable device\u003c\/h3\u003e\n\u003cp\u003eThe pre-moistened swab and reagent are in one device, with no pipetting or mixing. Hygiena describes the plastic as recyclable.\u003c\/p\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003col style=\"margin:0;\"\u003e\n\u003cli\u003eLet the device warm to room temperature (21–25 °C).\u003c\/li\u003e\n\u003cli\u003ePull out the swab and swab the surface in a crisscross pattern, rotating the swab. Use a 10 × 10 cm area on flat surfaces. Don't touch the swab tip.\u003c\/li\u003e\n\u003cli\u003eReturn the swab to the tube. Break the Snap-Valve and squeeze the bulb twice to release all the liquid.\u003c\/li\u003e\n\u003cli\u003eShake for 5 to 10 seconds to wet the swab tip.\u003c\/li\u003e\n\u003cli\u003eIncubate at \u003cstrong\u003e37 °C for 30 minutes\u003c\/strong\u003e. Read early if the liquid turns purple.\u003c\/li\u003e\n\u003cli\u003eCompare the colour to the chart on the tube label and record the result.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eReading the Result\u003c\/h2\u003e\n\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eColour\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eResult\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:10px; text-align:left;\"\u003eAction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eGreen (including green-grey)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003ePass\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eClean. No further action.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eGrey\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eCaution\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSmall amount of residue. Re-rinse, re-clean or re-test according to your protocol.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003ePurple\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eFail\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eNot clean. Re-clean and re-test.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003cp\u003e\u003cem\u003eSteps and interpretation are from the Hygiena MediCheck instructions for use. A negative control (a device activated without sampling) can be incubated alongside for colour comparison.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-top:12px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMediCheck™ Protein Residue Test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eItem number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMDCK-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003ePack\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e100 tests per box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eDetects\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eProtein residue (also reacts with reducing substances)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eAbout 3 µg protein at 37 °C, 30 min (per Hygiena)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eTime to result\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e5–30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eIncubation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e37 °C (incubator required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eResult\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eVisual: green (pass), grey (caution), purple (fail)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eStorage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e2–25 °C (36–77 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eShelf life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eUse by the expiry date on the device and label\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eUse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSingle use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px; width:40%;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eHygiena\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cem\u003eSpecifications are from the Hygiena MediCheck instructions for use and product information.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eSelection \u0026amp; Handling Notes\u003c\/h2\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#fff8e5;\"\u003e\n\u003cul style=\"margin:0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eA cleaning check, not a sterility test.\u003c\/strong\u003e MediCheck verifies protein removal after cleaning. It doesn't replace sterilization monitoring, your facility's reprocessing procedures or the instrument manufacturer's reprocessing instructions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest before disinfection.\u003c\/strong\u003e Hygiena advises testing after detergent cleaning and rinsing, but before terminal disinfection, or after the proper dwell time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterferences:\u003c\/strong\u003e peroxide-based disinfectants can cause false positives, and high concentrations of alkaline detergents or sanitizers may cause false negatives. Sugars, tannins and ascorbic acid also react.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncubator required.\u003c\/strong\u003e Results are based on 37 °C. Testing at lower temperatures may not reach the stated sensitivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDon't swab visibly soiled items.\u003c\/strong\u003e Heavy soil overloads the swab. Clean first, then verify.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwab reach:\u003c\/strong\u003e the swab samples surfaces it can reach. Confirm suitability for narrow lumens or complex devices with your reprocessing team.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle use only.\u003c\/strong\u003e See the Safety Data Sheet for handling information.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eProduct Documents\u003c\/h2\u003e\n\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hygiena.com\/documents\/62366\/medicheck-product-sheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHygiena MediCheck Product Sheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hygiena.com\/documents\/64081\/medicheck-instructions-en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHygiena MediCheck Instructions for Use (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed the Safety Data Sheet or a certificate of analysis for a specific lot? \u003ca href=\"\/pages\/contact\"\u003eContact Cambridge\u003c\/a\u003e and we'll request it from Hygiena.\u003c\/p\u003e\n\n\u003ch2\u003eCanadian Purchasing Support\u003c\/h2\u003e\n\u003cp\u003eCambridge Environmental Products is a Canadian-owned laboratory supply distributor based in Ontario and has served Canadian labs since 1993. We supply Hygiena hygiene monitoring tests with CAD pricing and shipping across Canada. We work with sterile processing departments, dental practices, laboratories and research facilities, and can help with quotes and standing orders. Browse our \u003ca href=\"\/collections\/lab-supplies\"\u003elab supplies\u003c\/a\u003e collection for more.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eWhat is MediCheck used for?\u003c\/h3\u003e\n\u003cp\u003eChecking that surgical and dental instruments, and washer-disinfector surfaces, are free of protein residue after cleaning.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHow sensitive is it?\u003c\/h3\u003e\n\u003cp\u003eHygiena states it detects about 3 µg of protein after 30 minutes at 37 °C.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHow long does it take?\u003c\/h3\u003e\n\u003cp\u003e5 to 30 minutes at 37 °C. Heavily soiled samples turn purple sooner.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eDo I need an incubator?\u003c\/h3\u003e\n\u003cp\u003eYes. The test is incubated at 37 °C. A dry block incubator set to 37 °C works.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eDoes it replace sterilization indicators?\u003c\/h3\u003e\n\u003cp\u003eNo. It verifies cleaning. Continue to use your normal sterilization monitoring and reprocessing procedures.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eHow should I store it?\u003c\/h3\u003e\n\u003cp\u003eBetween 2 °C and 25 °C. Let devices reach room temperature before use.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px; line-height:1.35;\"\u003eIs MediCheck available in Canada?\u003c\/h3\u003e\n\u003cp\u003eYes. Cambridge Environmental Products supplies Hygiena MediCheck across Canada with CAD pricing.\u003c\/p\u003e\n\n\u003cdiv style=\"border:1px solid #d9d9d9; padding:18px; margin:24px 0; border-radius:8px; background:#f8f8f8;\"\u003e\n\u003ch3 style=\"font-size:18px; line-height:1.35; margin-top:0;\"\u003eNeed Help with Cleaning Verification?\u003c\/h3\u003e\n\u003cp\u003eTell us:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe instruments or surfaces you need to verify\u003c\/li\u003e\n\u003cli\u003eWhether you have a 37 °C incubator\u003c\/li\u003e\n\u003cli\u003eHow many tests you use per month\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe'll help you choose the right Hygiena tests and set up standing orders.\u003c\/p\u003e\n\u003ca href=\"\/pages\/contact\" style=\"display:inline-block; padding:12px 18px; background:#1f4e79; color:#ffffff; text-decoration:none; border-radius:5px; font-weight:bold;\"\u003e\nContact Cambridge for Product Support\n\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Hygiena","offers":[{"title":"Default Title","offer_id":50053574164739,"sku":"MDCK-100","price":504.13,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/pf-medicheck-e1614969521259.webp?v=1793216099"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/collections\/Hygiena_Logo_1.jpg?v=1793215125","url":"https:\/\/cambridgeenviro.com\/collections\/hygiena.oembed","provider":"Cambridge Environmental Products, Inc.","version":"1.0","type":"link"}