{"title":"Food Production: pH \u0026 Acidity","description":null,"products":[{"product_id":"milwaukee-mw180-max-ph-mv-ec-tds-nacl-temp-bench-meter","title":"Milwaukee MW180 MAX pH\/mV\/EC\/TDS\/NaCl\/Temp Bench Meter","description":"\u003cp style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cu data-mce-fragment=\"1\"\u003eMilwaukee MW180 MAX pH\/mV\/EC\/TDS\/NaCl\/Temp Bench Meter with Logging\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe Milwaukee MW180 5-in-1 MAX pH\/ORP\/EC\/TDS\/NaCl\/Temp. Logging Bench Meter is fast, reliable, simple to operate, and is designed with a small lab space footprint.  It is ideal for use by horticulture, labs, food processing, water treatment, education and many other applications with challenging pH\/ORP\/EC\/TDS\/NaCl\/Temp. measurement needs.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWith easy 1-point EC\/NaCl and up to 3-point pH calibration, 7 memorized standard pH buffer choices, 6 memorized EC calibration solutions, and 2-point temperature calibration, the meter can be quickly calibrated to a higher temperature accuracy compared to other meters.  It also provides a more accurate temperature compensation readings than a 1-point calibration.  The MW180 5-in-1 MAX Bench Meter is accurate to ± 1% of reading for EC\/TDS and NaCL. \u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe meter comes with a MA814DB\/1 (4 ring) conductivity probe, lab grade MA917B\/1 pH electrode and temperature sensor MA831R, allowing the meter to automatically adjust the pH\/ORP\/EC\/TDS\/NaCl reading for the effect of temperature (ATC).\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cu data-mce-fragment=\"1\"\u003eFeatures:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFast, easy-to-read results with large duel level digital LCD readout\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eExtreme accuracy to +\/-0.002 pH and 1% of reading for EC\/TDS\/NaCl |+\/- 0.4°C (+\/-0.8°F)\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eExtended ranges for pH\/ORP\/EC\/TDS\/NaCl\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLightweight, sleek design featuring a small benchtop footprint\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eSimple, easy-to-use logging and RS232\/USB (opto-isolated) download functions\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eGLP data, date and time\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLog-on-demand or auto, up to 50 records each parameter\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eEasy measurement: just place the probe(s) in the sample, gently stir and wait for the reading to stabilize\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eUp to 3-point pH automatic calibration, simple single point factor calibration for EC\/TDS\/NaCl, and two point for temperature allowing increased accuracy\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRugged low maintenance, high performance, easy-to-clean pH\/EC\/TDS\/NaCl\/Temp probes\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eBuilt in temperature sensor\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e12VDC power supply (included)\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTemperature compensation automatic or manual\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eInternal clock date to keep track of different time-dependent functions (calibration, timestamp, calibration time out)\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e3-foot probe cables for extra flexibility when testing\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIncludes MA9315 electrode holder, pipets, initial calibration solutions, software and all cables\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cu data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003epH Range: -2.00 to 16.00 pH \/ -2.000 to 16.000 pH\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003emV Range: ±699.9 mV \/ ±2000 mV\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eEC Range: 0.00 to 29.99 uS\/cm \/ 30.0 to 299.9 uS\/cm\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eEC Range: 300 to 2999 uS\/cm\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eEC Range: 3.00 to 29.99 mS\/cm \/ 30.0 to 200.0 mS\/cm\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eEC Range: up to 500.0 mS\/cm (uncompensated EC) *\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTDS Range: 0.00 to 14.99 ppm (mg\/L)\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTDS Range: 15.0 to 149.9 ppm (mg\/L) \/ 150 to 1499 ppm (mg\/L)\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTDS Range: 1.50 to 14.99 ppt (g\/L) \/ 15.0 to 100.0 ppt (g\/L)\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTDS Range: up to 400 g\/L (uncompensated TDS) * (with 0.80 factor)\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eNaCl Range: 0.0 to 400.0%\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRange: -20.0 to 120.00°C (-4.0 to 248.0°F)\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003epH Resolution: 0.01 pH \/ 0.001 pH\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003emV Resolution: 0.1 mV \/ 1 mV\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eEC Resolution: 0.01 uS\/cm \/ 0.1 uS\/cm \/ 1 uS\/cm\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eEC Resolution: 0.01 mS\/cm \/ 0.1 mS\/cm\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTDS Resolution: 0.01 ppm (mg\/L) \/ 0.1 ppm (mg\/L) \/ 1 ppm (mg\/L)\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTDS Resolution: 0.01 ppt (g\/L) \/ 0.1 ppt (g\/L)\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eNaCl Resolution: 0.1%\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTemperature Resolution: 0.1°C \/ (0.1°F)\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAccuracy @ 20°C \/ 68°F\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003epH: ±0.01 \/ ±0.002 pH\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003emV: ±0.2 mV \/ ±1 mV\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eEC: ±1% of reading \/ ±0.05 uS\/cm or 1 digit, whichever is greater\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTDS: ±1% of reading \/ ±0.03 ppm or 1 digit, whichever is greater\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eNaCl: ±1% of reading\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTemperature: ±0.4°C (±0.8°F)\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRel mV offset: ±2000 mV\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003epH: 1, 2 or 3 calibration points, with 7 memorized buffers: 1.68, 4.01, 6.86, 7.01, 9.18, 10.01 and 12.45\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eEC\/TDS: 1-point slope calibration, 6 standards: 84 uS\/cm, 1413 uS\/cm, 5.00 mS\/cm, 12.88 mS\/cm, 80.0 mS\/cm, 111.8 mS\/cm \/ 1-point offset calibration: 0.00 uS\/cm\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eNaCl: 1 point, with MA9050 salinity calibration solution\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTemperature: 2 points, 0 and 50°C (32 and 122°F)\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTemperature Compensation: Automatic or manual from -20.0 to 120.0°C (-4.0 to 248.0°F)\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eConductivity temperature coefficient: Selectable 0.00 to 6.00 % \/ °C (EC and TDS only)\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTDS factor: 0.40 to 0.80 \/ Default value: 0.50\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003epH Probe: MA917B\/1 (included)\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTemperature Probe: MA831R (included)\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eEC Probe: MA814DB\/1 (4-ring, included)\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLogging-On-Demand: Maximum 50 samples for each range: (pH, mV \/Rel mV, EC, TDS, NaCl)\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003ePC Connectivity: RS232\/USB opto isolated\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003ePower Supply: 12 VDC adapter (included)\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDimensions: 230 x 160 x 95 mm (9.0 x 6.3 x 3.7 inches)\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eEnvironment: 0 to 50°C \/ 32 to 122°F; max RH 95%\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWeight: 0.9 kg \/ 2.00 lbs.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWarranty: 3 years Meter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e*Uncompensated conductivity (TDS) is the conductivity (or TDS) value without temperature compensation.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/milwaukeeinstruments.com\/content\/manuals\/MANMW180_12_20.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eMilwaukee MW180 Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\" data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cu data-mce-fragment=\"1\"\u003eCARE AND USE\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003epH\/EC\/TDS meters usually start performing poorly because of problems with the sediment on the conductivity probe's rings or build-up on the glass pH bulb. The dirt on the EC probe rings or on the pH bulb can change impedance. Cleaning the rings is simple, simply slide the plastic shield off and clean with DI water and soft cloth. For pH, simply soak the pH electrode in MA9016 cleaning solution.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe life of your meter can also be extended in the following ways:\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cu data-mce-fragment=\"1\"\u003eStorage\u003c\/u\u003e - When not in use, store the meter and EC probe in a safe area to avoid damage. The EC probe is stored dry. The pH probe should be stored wet with MA9015 storage solution to keep the bulb moist during non-use times for best performance and life duration.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cu data-mce-fragment=\"1\"\u003eCalibration\u003c\/u\u003e - The MW180 MAX is easy 1-point EC\/TDS\/NaCl calibration for ease-of-use, up to 3-point pH calibration and 2-point temperature calibration for best accuracy in (ATC).  Calibrating regularly is the best way to keep the meter readings accurate. \u003c\/p\u003e","brand":"Milwaukee Instruments","offers":[{"title":"Default Title","offer_id":39366309740593,"sku":"9139-MW180","price":1362.96,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/MW1801.jpg?v=1624291232"},{"product_id":"ohaus-aquasearcher-ab33ph-ph-bench-meter","title":"Ohaus AQUASEARCHER™ AB33PH pH Bench Meter","description":"\u003cdiv style=\"text-align: center;\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eOhaus AQUASEARCHER™ AB33PH  Standard pH Bench Meter\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003eOHAUS AquaSearcher™ AB33PH benchtop meter is designed to be reliable, efficient and user friendly. The i-Steward ensures repeatable and consistent measurement accuracy for optimal peace of mind. Large LCD display and touch keypad makes changing the parameters, executing setup, and performing calibration as simple as using a smartphone.\u003cbr\u003e\u003cbr\u003ei-Steward Indicators include the pH electrode condition, “Electrode Dirty\/Broken,” and reminder when meter needs recalibration. Perform up to a 5-point pH calibration using automatic buffer recognition of 5 predefined buffer groups. Calibration log stores ten most recent calibrations. Compact stirrer can be used to uniformly mix solutions to get fast and repeatable results at no additional cost. \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e• With multifunctional touch keypads, AB33 makes measurement simple and fast\u003cbr data-mce-fragment=\"1\"\u003ewithin 3 steps. The intelligent i-Steward monitors the condition of electrodes,\u003cbr data-mce-fragment=\"1\"\u003eensuring accuracy of the results.\u003cbr\u003e• Able to store up to 1000 items in its internal memory, AB33 allows for efficient\u003cbr data-mce-fragment=\"1\"\u003edata documentation. Standard RS232 and USB interface allows\u003cbr data-mce-fragment=\"1\"\u003econnection to external devices for expanded storage.\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cspan\u003e• Auto endpoint mode and auto buffer recognition makes pH calibration\u003cbr data-mce-fragment=\"1\"\u003eeasy. Auto temperature compensation, adjustable TDS factor and two kinds of\u003cbr data-mce-fragment=\"1\"\u003ecell conductivity probe compatibility are all features well suited for universal\u003cbr data-mce-fragment=\"1\"\u003elaboratory applications.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e• Adjustable TDS Factor - The factor that relates conductivity to total dissolved solids is based on the type of sample being measured. To have correct temperature compensation when measuring conductivity, the linear compensation coefficient adjusts by automatic temperature compensation. Selectable reference temperatures of 20 or 25 ºC for temperature compensated conductivity readings.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cem\u003e\u003cstrong\u003ePackages -  Available in two configurations:\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\n\u003ctable data-mce-fragment=\"1\" width=\"100%\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"text-align: center;\"\u003e \u003cstrong\u003ea-AB33PH-B\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"text-align: center;\"\u003e\u003cstrong\u003ea-AB33PH-F\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cul\u003e\n\u003cli\u003ea-AB33PH Benchtop Meter\u003c\/li\u003e\n\u003cli\u003eStand-Alone Electrode Holder\u003c\/li\u003e\n\u003cli\u003eNo Electrodes (ST310)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\n\u003cul\u003e\n\u003cli\u003ea-AB33PH-B Package +\u003c\/li\u003e\n\u003cli\u003eST310 pH Electrode\u003c\/li\u003e\n\u003cli\u003epH Buffer Mini Kits (4 × 50mL)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cstrong\u003e\u003cstrong\u003e\u003cbr\u003e\u003cspan style=\"text-decoration: underline;\"\u003e﻿\u003c\/span\u003e\u003cspan style=\"text-decoration: underline;\"\u003e﻿Specifications:\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/strong\u003e\n\u003ctable data-mce-fragment=\"1\" class=\"spec-table\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e-5 °C – 110 °C;  -2.00 – 16.00 pH;  -2000.00 – +2000.00 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMeasurement Resolution\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e0.1 °C;  0.01 pH;  1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e±0.5 °C;  ±1 mV;  ±0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eLCD with backlight \u0026amp;  one-line dot matrix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eElectrode\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eST310 (Included with a-AB33PH-F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eAccuracy ± (mV)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eAccuracy ± (Temperature)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e0.5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e8.3 in x 2 in x 5.6 in (210 mm x 51 mm x 142 mm) (LxHxW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1.1 lb (0.5 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eParameter\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003epH\/mV\/ORP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003epH accuracy (±)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e0.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003ePower\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eAC Adapter (Included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eWorking Environment\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e5°C – 40°C, 80% RH, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e﻿Additional Literature:\u003c\/span\u003e\u003cbr\u003e\u003c\/strong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/files\/Aquasearcher_AB33_Datasheet_US_80776666_A.pdf?v=1628707446\" target=\"_blank\"\u003eAquasearcher Data Sheet -EN\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/dmx.ohaus.com\/WorkArea\/showcontent.aspx?id=4295004824\" target=\"_blank\"\u003eAquasearcher Data Sheet - FR\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/dmx.ohaus.com\/WorkArea\/showcontent.aspx?id=4295005819\" target=\"_blank\"\u003eQuick Start Guide\u003c\/a\u003e\u003cstrong\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/03FETrq0AVs\" height=\"506\" width=\"900\" allowfullscreen=\"\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" frameborder=\"0\"\u003e\u003c\/iframe\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/div\u003e","brand":"Ohaus","offers":[{"title":"a-AB33PH-B","offer_id":39417967935537,"sku":"AB33PH-B","price":965.89,"currency_code":"CAD","in_stock":true},{"title":"a-AB33PH-F","offer_id":39417968001073,"sku":"AB33PH-F","price":1090.79,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2006\/8997\/products\/AB33PH_Holder_Electrode_Beaker_Insert_3.jpg?v=1628708514"}],"url":"https:\/\/cambridgeenviro.com\/collections\/food-production-ph-and-acidity.oembed","provider":"Cambridge Environmental Products, Inc.","version":"1.0","type":"link"}